| 1 | Dismantling wrought iron or mild steel work of any description not otherwise provide for. |
| 2 | Material and labour for pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of existing plain or corrugated sheet of any description complete all as specified and/ or as directed by Engr-in-Charge. |
| 3 | Material and labour for pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of existing plain or corrugated sheet of any description complete all as specified and/ or as directed by Engr-in-Charge. |
| 4 | Supply and fixing mild steel rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410-W (Gde- E- 250) quality-A Fe including dismantling structural steel work of any description in any position, complete all as specified and/ or as directed by Engr-in-Charge. |
| 5 | Material and labour for two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer to steel surfaces n. exc 10cm width or girth including preparation of new surfaces complete all as specified and/ or as directed by Engr-in-Charge. |
| 6 | Taking down cement plaster on brick or concrete surfaces including racking out joints hacking for key, scrubbing down with water etc. complete all as specified and/ or as directed by Engr-in-Charge. |
| 7 | Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar complete all as specified and/ or as directed by Engr-in-Charge. |
| 8 | Material and labour for Pre-cast cement concrete 1:3:6 type C1 (20mm graded stone aggregate) block masonry with solid blocks, exc 10cm in width and setting in CM 1:6 complete all as specified and/ or as directed by Engr-in-Charge. |
| 9 | Material and labour for 15mm thick rendering on other than fair faces of brick works finished even and smooth without using extra cement in cement mortar 1:4 complete all as specified and/ or as directed by Engr-in-Charge. |
| 10 | Material and labour for 15 mm thick rendering on fair faces of brick works finished even and smooth without using extra cement in cement mortar 1: 6 complete all as specified and as directed |
| 11 | Material and labour for preperation of new plastered surface and apply two coats of cement base paint over a coat of primer complete all as specified and/ or as directed by Engr-in-Charge. |
| 12 | Material and labour for preperation of new plastered surface and apply two coats of oil bound distemper over a coat of primer complete all as specified and/ or as directed by Engr-in-Charge. |
| 13 | Material and labour for preperation of old plastered surface and apply two coats of oil bound distemper complete all as specified and/ or as directed by Engr-in-Charge. |
| 14 | Material and labour for preperation of old plastered surface and apply two coats of cement base paint complete all as specified and/ or as directed by Engr-in-Charge. |
| 15 | Demolition cement concrete (unreinforced) of any descriptions, in ground floors not exc. 15 cm thick, above or below ground level, complete all as specified and/ or as directed by Engr-in-Charge. |
| 16 | Material & labour for 75mm thick PCC 1:4:8 type D-2, using 40mm graded crushed stone aggregate as in sub base complete all as specified and/ or as directed by Engr-in-Charge. |
| 17 | Material & labour for Coloured Chequered cement concrete tiles, machine pressed, factory made of size 300mmx300mmx25mm thick, set, jointed and pointed in neat cement slurry, with grey cement and no pigment, laid in floors, over and including 20mm thick screed bed in cement mortar 1:4, complete all as specified and/ or as directed by Engr-in-Charge. |
| 18 | Providing and laying 80 mm thick factory made chamfered edge cement concrete paver block M-30 grade with approved colour design and pattern as in footpath, parks, lawns, drive ways or ligght traffic parking etc, of required strength, thickness & size/shape, made by table vibratory method using PU mould laid in required colour & pattern over and incl 50 mm thick compacted bed of course sand complete all as specified and/ or as directed by Engr-in-Charge. |
| 19 | Material & labour for 75mm thick PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth protection including making proper joints with bitumen mastic with sand as per specification at an interval of 3m complete all as specified and/ or as directed by Engr-in-Charge. |
| 20 | Material & labour Non-Skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm, and n.exc 0.38 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed or bedding layer in Cement Mortar 1:6 for laying floor finishes incl dismantling floor tiling including cement mortar bedding (but not backing), removing serviceable tile to store and rubbish off the premises complete all as specified and/ or as directed by Engr-in-Charge. |
| 21 | Material and labour for for 7mm thick non skid coloured ceramic tiles (area of each tile exc 0.11 and n exc 0.18 sqm) etc set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigments and 15mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes incl dismantling floor tiling including cement mortar bedding (but not backing), removing serviceable tile to store and rubbish off the premises complete all as specified and/ or as directed by Engr-in-Charge. |
| 22 | Taking down chowkhat or frames exc. 1.50 Sqm not exc. 4 Sqm (without taking down shutters from the frames) |
| 23 | All as per item No 22.00 above, but not exc 1.50 Sqm |
| 24 | Supply and fixing 35 mm thick 2nd class hardwood, plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and/ or as directed by Engr-in-Charge |
| 25 | Supply and fixing Powder coated (minimum thickness of power coating 50 micron) anodised aluminium window and ventilator shutters, side hung type without sash,aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading screws, anodised aluminium fittings such as peg stays 150mm long(1 no.) hinges type B-21 100mm long (2 no.) suitable handle(1no) incl 4.8 m thick glass etc. complete all as specified and/ or as directed by Engr-in-Charge. |
| 26 | Supply and fixing Sheet glass 4.8 mm thick, exc 0.5 sqm in each pane complete all as specified and/ or as directed by Engr-in-Charge. |
| 27 | Supply and fixing 150mm long aluminium anodised barrel tower bolt of extruded section in old or new position. |
| 28 | Supply and fixing aluminum door handle cast type 150 mm in new position. |
| 29 | Supply and fixing 250 mm long aluminum door sliding door bolt incl all necessary fitting and bolts. |
| 30 | Supply and fixing 100mm long mild steel medium weight but hinges cold rolled. |
| 31 | Material and labour for two coats of synthetic enamelled paint over a coat of pink primer on new decorated wooden surfaces complete all as specified and/ or as directed by Engr-in-Charge. |
| 32 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) or insulation boards / slabs/ blankets, any thickness, including fillets, complete all as specified and/ or as directed by Engr-in-Charge. |
| 33 | Dismantling timber scantlings 40 sq. cm and over in section, in any position. |
| 34 | Material & labour for Second class hard-wood in scantlings. |
| 35 | Material & labour for 9mm thick prelaminated particle board, medium interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed to walls of any description or timper scantling with screws to timber frame work, complete all as specified and/ or as directed by Engr-in-Charge. |
| 36 | Demolition of cement concrete (reinforced) of any description and in any position not other wise specifically provided for and removing debris outside the MD land complete all as specified and/ or as directed by Engr-in-Charge. |
| 37 | Material & labour for providing precast reinforced cement concrete type A1, 1:2:4 using 12.5 mm graded aggregate as in landings, cover slabs (for man holes etc) and similar articles with plain faces and setting in cement mortar 1:6 complete with joints to match including use of necessary formwork .Note : Supply and fixing reinforcement shall be measured and paid separately. |
| 38 | Supply and fixing TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia. |
| 39 | Supply and fixing Galvanised stainless steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples. |
| 40 | Taking up or down steel tubing 20mm bore including cleaning for refixing or removal to store.complete all as specified and/ or as directed by Engr-in-Charge. |
| 41 | Supply and fixing 25mm bore 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass treaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and/ or as directed by Engr-in-Charge. |
| 42 | Supply and fixing 1000 ltr capacity rotational moulded polythelene water storage tanks triple layer white colour (cylindrical vertical with clossed top) hoisted and fixed in position including dismantling all as specified in SSR Part 1 complete all as specified and/ or as directed by Engr-in-Charge. |
| 43 | Demolition and breaking up 150mm dia drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar including the pipe inserted in Man holes walls etc. for undermentioned drain pipes, including removal of rubbish outside MD land complete all as specified and/ or as directed by Engr-in-Charge. |
| 44 | Material and labour for providing cement concrete 1:3:6 type C-2 bed to 150mm bore of drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for, complete all as specified and/ or as directed by Engr-in-Charge |
| 45 | Supply and fixing 150mm dia bore (inner dia) double wall corrugated HDPE Pipe (SN-8) in any length including all fittings and jointing with eastomeric rubber link and cuppler /other jointing materials laid in trenches are in floors complete all as specified and/ or as directed by Engr-in-Charge. |
| 46 | Cutting in to existing manholes for forming new drains and making good to pipe and making good to pipe and rendering, cutting out existing benching in cement concrete 1:2:4 type B1(in 1/2 or 3/4 round in section) and reforming benching as reqd for 150mm bore pipe complete all as specified and/ or as directed by Engr-in-Charge. |
| 47 | Supply and fixing in repair Vitreous China half stall urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive offixing supply pipe to flushing cistern, trap and waste pipe) |
| 48 | Supply and fixing in repair 10 ltrs capacity incl PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets & flush pipe complete all as specified and/ or as directed by Engr-in-Charge. |
| 49 | Supply and fixing viterous China squatting pan or Orissa patten 580 x 440 mm white with integral foot rest (excluding cistern) with front or back inlet ant pattern as in repairs incl bedding with PCC type B-1 1:2:4 , using 20 mm graded crushed stone aggregate complete all as specified and/ or as directed by Engr-in-Charge. |
| 50 | Supply and fixing in repairs viterous China wash down water closet pan pedestal pattern white incl seat cover (excluding flushing cistern and flush pipe) complete all as specified and/ or as directed by Engr-in-Charge. |
| 51 | Supply and fixing in repairs 600 X 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with CP brass screws and cup washer complete all as specified and/ or as directed by Engr-in-Charge. |
| 52 | Supply and fixing PVC connection 15mm bore with ptmt nuts of length 600mm. |
| 53 | Supply and fixing in repairs 15mm bore bib taps fancy type chromium plated with capstan head chromium plated screwed down screwed for iron pipe or brass ferrule. (Min wt 350 Gms) |
| 54 | Supply and fixing in repairs 15mm bore stop cock fancy type chromium plated cast copper alloy screw down under high pressure with crutch or butter fly handle screwed both ends for iron pipe or brass ferrule. |
| 55 | Supply and fixing in repairs 15mm bore Pillar taps fancy type chromium plated with capstan head chromium plated screwed down screwed for iron pipe or brass ferrule. (Minm wt 350 Gms) |
| 56 | Supply and fixing in repairs 25mm dia powder coated mild steel, chromium plated curtain rod including brackets as in repairs. |
| 57 | Supply and fixing in repair aluminium door closer (aluminium extruded section) hydraulically regulated designation No 3, universe type, suitable for door shutte of 851 mm to 1000 in width and of weight 61 to 80 kg. |
| 58 | Supply and fixing PVC (SWR) P/S trap 110mm bore for industrial type W/C. |
| 59 | Supply and fixing Grating doom 125 mm of CP complete all as specified and/ or as directed by Engr-in-Charge. |
| 60 | Supply and fixing in repairs PVC waste pipe 32mm bore with cup and washers complete on new or old locations, complete all as specified and/ or as directed by Engr-in-Charge. |
| 61 | Taking down carefully copper/aluminium point wiring (light, fan, socket and power point) complete fittings such as switches, ceiling rose, regulators, socket etc and removing material from site and making good disturbed surfaces of walls, floors/ceiling to match the existing surface complete all as specified and/ or as directed by Engr-in-Charge. |
| 62 | Point wiring complete with 1.5 Sqmm nominal area of copper conductor multi stranded PVC insulated and unsheathed 1100 volts cable drawn through & including PVC casing & caping with standard accessories such as elbows, tees, junctions etc. and PVC moulded terminal box with top cover of including PVC insulated unsheathed solid 1.5 Sqmm copper conductor cable as continuous earth lead all as specified and directed for the following:- |
| 63 | One light point/fan controlled by one way switch complete all as specified and/ or as directed by Engr-in-Charge. |
| 64 | One 3 pin socket outlet 5 Amps, 230 volts point on independent board complete all as specified and/ or as directed by Engr-in-Charge. |
| 65 | One 3 pin socket outlet 5 Amps, 230 volts point on same board complete all as specified and/ or as directed by Engr-in-Charge. |
| 66 | All as per Item No 62 above, but using cables 4 Sq mm size complete all as specified and/ or as directed by Engr-in-Charge. |
| 67 | Supply and fix Switch piano flush button single pole 6 Amps 230 volts one way complete all as specified and/ or as directed by Engr-in-Charge. |
| 68 | Supply and fix switch Socket out let two in one 3 pin 6 Amps flush type.230 volts complete all as specified and/ or as directed by Engr-in-Charge. |
| 69 | Supply and fix switch Socket combination out let multi purpose 5 pin 6 Amps and 16Amps 230 volts complete all as specified and/ or as directed by Engr-in-Charge. |
| 70 | Supply and fix ceiling rose surface bakelite 65x50 mm two to three terminals complete all as specified and/ or as directed by Engr-in-Charge. |
| 71 | Supply and fix lamp holder PVC/Poly corbonate type insulated body with back plate suitable for batten fittings complete all as specified and/ or as directed by Engr-in-Charge. |
| 72 | Supply and fix in replacement of door Bells electric Ding- dong/ musical type single phase 230 Volts complete all as specified and/ or as directed by Engr-in-Charge. |
| 73 | Supply and fix in replacement of LED light fittings 1x20 watt, 220 volts AC, decorative box type with driver, holder including 20 W LED tube lights suitable for roof ceiling including connecting up with three core copper flexible conductor cable of sutable size complete all as specified and/ or as directed by Engr-in-Charge. |
| 74 | Supply and fixing in repalcement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type ( Warm White )with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and/ or as directed by Engr-in-Charge. |
| 75 | M&L for submain wiring along with earth wire with the following sizes of FRLSH PVC insulated copper conductor, single core cable in surface/recessed as required in PVC casing caping wire size 2x6.0 sqmm + 1x6.0 sqmm earth wire including taking down complete all as specified and/or directed by Engr-in-Charge. |
| 76 | Supply and fix in replacement of MCB DB SPN 8 Way double door 240 Volt 50 Hz wih complete accessories. Make : Havells/ ABB/ Schenider |
| 77 | Supply and fix in replacement of MCB SPN 40-63 Amps 'C' Series complete all as specified and/or directed by Engr-in-Charge. Make : Havells/ ABB/ Schenider. |
| 78 | Supply and fix in replacement of MCB SP 6 to 32 Amps 'C' Series complete all as specified and/or directed by Engr-in-Charge. Make : Havells/ ABB/ Schenider. |
| 79 | Supply and laying in replacement of XLPE insulated, aroured, heavy duty electric cables, with stranded aluminium copper conductor rating 1100 volts grading of size 10 sqmm 4 core laid in trenches or passing through pipes, ducts or fixed to walls / poles, complete all as specified and/or directed by Engr-in-Charge. |
| 80 | Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth, for foundation etc. or for laying UG cable in trenches on plain and not exc 1.5m in depth in any type of soil and getting out, complete all as specified and/or directed by Engr-in-Charge. |
| 81 | Returning, filling in (soil), including spreading, levelling, watering and well ramming in layers not exc. 25cm, complete all as specified and directed by Engr in Charge. |
| 82 | Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified and directed by Engr in Charge. |
| 83 | M&L for Sand cushioning to under ground cables 8 cm below the cable before laying & 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I, 2009. Note : Punned thickness only will be measured and paid. |
| 84 | Labour only for laying old serviceable cable covers retrieved from excavation complete all as specified and/ or as directed by Engr-in-Charge. |
| 85 | Supply and laying of factory made, machine pressed, unreinforced, pre-cast concrete cable cover class LV type-1 flat size 250 mm x 150 mm x 50mm, complete all as specified and directed. Please Enable Macros to View BoQ information |