| 1 | Repairs to internal electrifications including replacement of U/S light fittings with LED lights and other misc e/m Works at 17 FBSU AF, 257 SU, AFSC, Muttathara complex GE(AF) TVM |
| 2 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc all as specified and directed. |
| 3 | M&L for following point wiring complete with 1.5 Sqmm single core FRLSH PVC insulated unsheathed cable 1100 V grade multi stranded copper conductor drawn through non metallic rigid PVC conduit and accessories in surface of walls/ceilings including 1.5 Sqmm dia multistranded copper cable as earth continuity conductor connected to common earth dolly, including 1.22 mm thick pressed steel terminal boxes with 3.00 mm thick laminated sheet cover//2mm Modular metal flush box and suitable modular white cover plate with frame to house switch/regulators etc all as specified and directed. |
| 4 | All as per No 03 above, but for One fan/light /bell point controlled by one switch/bell push |
| 5 | All as per No 03 above, but for One switch socket outlet 5 Amps on independent board |
| 6 | All as per No 03 above, but for One socket outlet 5 Amps on the same board |
| 7 | All as per Item No 3 here-in- before but with 2.5 Sqmm PVC insulated multistranded copper conductor with 2.5 sqmm cable as earth continuity conductor for power Socket on independent board on the existing/new PVC surface conduit all as specified and directed. |
| 8 | M&L for following point wiring complete with 1.5 Sqmm single core FRLSH PVC insulated unsheathed cable 1100 V grade multi stranded copper conductor drawn through PVC Casing Capping and accessories in surface of walls/ceilings including 1.5 Sqmm dia multistranded copper cable as earth continuity conductor connected to common earth dolly, including 1.22 mm thick pressed steel terminal boxes with 3.00 mm thick laminated sheet cover/2mm Modular metal flush box and suitable modular white cover plate with frame to house switch/regulators etc including all as specified and directed. |
| 9 | All as per No 08 above, but for One fan/light /bell point controlled by one switch/bell push |
| 10 | All as per No 08 above, but for One 3 pin switch socket outlet 5 Amps on independent board |
| 11 | All as per No 08 above, but for One 3 pin socket outlet 5 Amps on the same board |
| 12 | All as per Item No 8 here-in-before but with 2.5 Sqmm PVC insulated multistranded copper conductor cable including 2.5 sqmm PVC insulated copper cable as earth continuity conductor for one switch socket outlet on independent board all as specified and directed. |
| 13 | M&L for following point wiring complete with 1.5 Sqmm single core FRLSH PVC insulated sheathed cable 1100 V grade multi stranded copper conductor drawn through and including non metallic rigid PVC conduit and accessories concealed in walls/ceilings including 1.5 Sqmm dia multistranded copper cable as earth continuity conductor connected to common earth dolly, including 2mm Modular metal flush Box and suitable Modular white cover plate with frame/1.22 mm thick pressed steel terminal boxes with 3.00 mm thick laminated sheet cover to house switch/regulators etc complete all as specified and directed. |
| 14 | All as per No 13 above, but for One fan/light /bell point controlled by one switch/bell push |
| 15 | All as per No 13 above, but for One switch socket outlet 5 Amps on independent board |
| 16 | All as per No 13 above, but for One 3 pin socket outlet, 5 Amps on the same board with other switches with cables 1.5 Sq mm size all as specified and directed. |
| 17 | All as per Item No 13 here-in- before but with 2.5 Sqmm PVC insulated multistranded copper conductor with 2.5 sqmm cable as earth continuity conductor for power Socket on independent board on the existing/new PVC surface conduit all as specified and directed. |
| 18 | M&L for following point wiring complete with 1.5 Sqmm single core FRLSH PVC insulated unsheathed cable 1100 V grade multi stranded copper conductor drawn through existing non metallic rigid PVC conduit and accessories in surface of walls/ceilings including 1.5 Sqmm dia multistranded copper cable as earth continuity conductor connected to common earth dolly, including 1.22 mm thick pressed steel terminal boxes with 3.00 mm thick laminated sheet cover//2mm Modular metal flush box and suitable modular white cover plate with frame to house switch/regulators etc taking down old one all as specified and directed. |
| 19 | All as per No 18 above, but for One fan/light /bell point controlled by one switch/bell push |
| 20 | All as per No 18 above, but for One switch socket outlet 5 Amps on independent board |
| 21 | All as per Item No 18 here-in-before but with 2.5 Sqmm PVC insulated multistranded copper conductor cable including 2.5 sqmm PVC insulated copper cable as earth continuity conductor for one switch socket outlet 15 Amps on independent board all as specified and directed. |
| 22 | Supply and fix in replacement switch piano flush button single pole oneway 5 amps all as specified and directed. |
| 23 | Supply and fix in replacement socket flush type 2 in 1, 3 pin 5 ampsall as specified and directed. |
| 24 | Supply and fix switch socket combination 3 pin 5 Amps flush type in repairsall as specified and directed. |
| 25 | Supply and fix in replacement of switch socket combination 5A/16 A , 5 in 1 flush type , universal flush typeall as specified and directed. |
| 26 | Supply and fix in replacement modular switch 1 way 6A 1 moduleall as specified and directed. |
| 27 | Supply and fix in replacement modular socket 6A 2/3 pin combined 2 moduleall as specified and directed. |
| 28 | Supply and fix in replacement modular switch 1way 16 A 1 moduleall as specified and directed. |
| 29 | Supply and fix in replacement modular socket 6A /16A 2/3 pin combination 2 moduleall as specified and directed. |
| 30 | Supply and fix in replacement modular Fan regulator , 120 w - 2 moduleall as specified and directed. |
| 31 | Supply and fix in replacement Modular bell push 6 A 1 module all as specified and directed. |
| 32 | Supply and fix in replacement ceiling rose surface bakelite with three terminals all as specified and directed.Make- Anchor/Havells/Legrand. |
| 33 | Supply and fix in replacement bell push flush type 5 Amps 230V single pole all as specified and directed. Make- Anchor/Havells/Legrand. |
| 34 | Supply and fix and Replace electric bell Ding Dong, AC 230 volts all as specified and directed. Make- Anchor/Havells/Legrand. |
| 35 | Supply and fix and Replace buzzer, AC 230 volts all as specified and directed. Make- Anchor/Havells/Legrand. |
| 36 | S & F in replacement electronic type fan regulator rotary step 120/280 watt all as specified and directed. Make- Anchor/Havells/Legrand |
| 37 | M&L for submain wiring with 2 Runs 4 Sq mm for phase and neutral and 1 runs of 4 Sqmm earth continuity conductor 1100 v grade PVC insulated unsheathed FRLSH grade copper conductor cable single core multistranded ISI marked drawn through PVC rigid conduit and accessories and concealed in walls / ceiling all as specified including taking down old sub main wiring all as specified and directed. |
| 38 | M&L for submain wiring with 2 Runs 6 Sq mm for phase and neutral and 1 runs of 6 Sqmm earth continuity conductor 1100 v grade PVC insulated unsheathed FRLSH grade copper conductor cable single core multistranded ISI marked drawn through PVC rigid conduit and accessories and concealed in walls / ceiling all as specified including taking down old sub main wiring all as specified and directed. |
| 39 | M&L for submain wiring with 2 Runs 10 Sq mm for phase and neutral and 1 runs of 10 Sqmm earth continuity conductor 1100 v grade PVC insulated unsheathed FRLSH grade copper conductor cable single core multistranded ISI marked drawn through PVC rigid conduit and accessories and concealed in walls / ceiling all as specified including taking down old sub main wiring all as specified and directed. |
| 40 | Taking down unserviceable MCB distribution board, S & F SPN 4 way of any size and capacity double door with suitable busbar including disconnecting from mains and making good the disturbed surfaces all as directed. Make- Anchor/Havells/Legrand all as specified and directed. |
| 41 | All as per item No 40 here in before but SPN 8 way. Make- Havells/Legrand/ABB all as specified and directed. |
| 42 | All as per item No 40 here in before but SPN 12 way. Make- Havells/Legrand/ABB all as specified and directed. |
| 43 | Supply and fix in replacement sheet metal enclosure distribution board for fixing MCBs with double door, TPN 4 way, 415 volts with suitable bus bar complete all as specified and directed. Make- Anchor/Havells/Legrand. |
| 44 | S & F in replacement Sheet Metal Enclosure for MAIN DBs, Triple Pole & Neutral, 4 Way , 415 Volts with 125 Amps rated neutral bus bar double door vertical type, grouting the DB and making good the disturbed surfaces with extra cement without any additional cost suitable for TP/SP outgoing to accommodate and including Space for fixing of MCCB 125A 25 KA as incoming all as directed. Make- ABB/Havells/Legrand all as specified and directed. |
| 45 | Disconnecting and removing the existing metal plug and socket and and provn of metal plug and socket single phase two pin and earth plug with MCB, SP 20 Amps and steel enclosure. Make- Anchor/Havells/Legrand all as specified and directed. |
| 46 | Taking down ceiling fan 1200mm sweep from any height and bringing down to floor, dismantling the ceiling fan, re-assembling the ceiling fan and refixing in position after repairs. Note: Spares will be measured and paid separately all as specified and directed. |
| 47 | All as per Item No.46 above but for exhaust fan 300mm/450mm sweep including replacing of rusted nut and bolts all as specified and directed. |
| 48 | All as per Item No. 46 above but for Pedestal / wall mounting fan of 400/450mm sweep including replacing of rusted nut and bolts all as specified and directed. |
| 49 | M & L for cutting & removing the burnt winding of ceiling fan of 1200 sweep and cleaning the slot, rewinding with super enamelled copper wire of suitable size, varnishing heating and insulating and reassembling the spares complete all as specified and directed. |
| 50 | All as per item No. 49 above but for exhaust fan 300mm sweep all as specified and directed. |
| 51 | All as per item No. 49 above but for exhaust fan 450mm sweep all as specified and directed. |
| 52 | Supply and replace the fan motor for wall mounting fan/ pedestal of 400/450mm sweep all as specified and directed. |
| 53 | Supply only ball bearing of ceiling fan of 1200 mm sweep. Make : SKF/NBC/TATA all as specified and directed. |
| 54 | All as per item No 53 but Exhaust fan of 300 mm sweep all as specified and directed. |
| 55 | All as per item No 53 but Exhaust fan of 450 mm sweep all as specified and directed. |
| 56 | M&L for Spray Painting of ceiling fans with one coat of synthetic enamel paint of same colour including preparation of old surfaces complete including numbering of fans as all as specified and directed existing for:- |
| 57 | All as per Item No.56 but Exhaust fan of 300/450 mm sweep all as specified and directed. |
| 58 | Supply and Replace capacitor 2.5 mfd suitable for ceiling fan all as specified and directed. Make – KELTRON/KEIL/BHEL/UNIVERSAL/TIBCON |
| 59 | Supply and Replace capacitor 4 mfd suitable for exhaust fan all as specified and directed. Make – KELTRON/KEIL/BHEL/UNIVERSAL/TIBCON |
| 60 | Disconnecting and removing the old unserviceable light fitting and supply and fix new energy efficient LED batten 1 x 20 watts 4 feet long batten type MCL LED type all prewired including connection with twin core flexible PVC 0.5 Sqmm complete all as specified and directed. Make; Havells/Wipro/Crompton |
| 61 | Disconnecting and removing the old unserviceable supply and fix new energy efficient LED batten 1 x 10watts 2 feet long powder coated white batten type all prewired including LED tube and connection with twin core flexible PVC 0.5 Sqmm complete all as specified and directed. Make- Havells/Wipro/Crompton |
| 62 | Removing existing Unserviceable surface mounting light fittings and supply and fix surface mounting LED light fittings 1 x 33 / 36 watts LED panel system efficiency 36 W LED 6500 K model suitable for armstrong/grid/POP false ceiling complete all as specified and directed. Make : Havells/Wipro/Crompton. |
| 63 | Supply and fix in replacement 415V 10KA 'C' curve miniature circuit breaker (MCB) TPN of 32 A and current carrying capacity in the DB complete with connection testing and commissioning all as specified and directed.Make:L&T/Legrand/Havells. |
| 64 | All as per Item No.63 but MCB TPN 63A capacity all as specified and directed. |
| 65 | Supply and fix in replacement of MCB 240V,50Hz,AC with repturing capacity 10kA of the MCB SP 6A-32 A f capacities all as specified and as directed. Make- Havells/Legrand/ABB. |
| 66 | All as per Item No 65 but RCCB Double pole 40A, 30mA all as specified and directed. |
| 67 | All as per Item No 65 but SPN 32 AMP all as specified and directed. |
| 68 | S&F LED driver for recess/surface mounted 33/36 Watt LED panel system efficiency 90lm/W etc complete as per sample complete all as specified and as directed.Make:Luker/ABB/Legrand/Havells |
| 69 | S&F in repairs LED bulk head fittings 12 watts with opal diffuser complete all as specified and directed Make :Havells/Wipro/Crompton |
| 70 | S&F in repairs building security light LED 20 watts complete with GI brackets not less than 1.2 Mtr made out of medium grade GI tubing complete all as specified and directed Make : Havells/Wipro/Crompton |
| 71 | Supply and fix in repair 9 Watt LED bulb pin type ,White/Warm white colour complete all as specified and as directed,Make:Goldmedal/Wioro/Havells/Crompton |
| 72 | S&F in repair recessed slim LED round down lighter/surface square light of capacity 18 W ,White/Warm white light complete all as specified and as directed:Make Gold medal-GL9C0203118 or Havells/Crompton |
| 73 | Supply & fixing in replacement of LED ceiling light 9 W( White/Warm) junction box down lighter suitable for installation in 5.08 cm (2) deep junction box of coloured light all as specified and directed. Make : Havells part No LHEBALPEIZ1W003 or equivalent in Phillips/ Bajaj/Wipro |
| 74 | S&F in repair of recessed slim LED round down lighter / square of capacity 12 W ,White/Warm white light complete all as specified and as directed: Make Gold medal-GL9C0308112 or Havells/Crompton |
| 75 | S&F in repair of Surface/Recessed slim LED round down lighter of capacity 6/7 W,White/Warm complete all as specified and as directed:Make Gold medal-GL91454/Havells/Crompton |
| 76 | S&F In repair of outdoor LED garden light(Focus light)/Wall Spot light ,White/Warm white light with spike stand of capacity 12 W complete all as specified and as directed |
| 77 | S&F in repair of LED mirror wall light(white/warm white) of capacity 20 W complete all as specified and as directed.Make:Wipro/Havells/Crompton/Luker |
| 78 | S &F in replacement of decorative mirror/wall light fixture gold finish with cognac hammered glass diffuser with 12 W warm white LED FILAMENT Lamp E27 base all as specified.Make:Luker/Havells/Crompton/Wipro. |
| 79 | S&F in replacement of Galactic Smart LED Strip 24W 5m with LED Driver all as specified and directed.Make Havells LHEHCNP1ND1W015 or equivalent in Cromton/Phillips/Luker/Bajaj/Wipro/Shakti. |
| 80 | Supply and fixing replacement of MCCB, 415 volts, four pole of capacity 100 Amps, 25 KA, adjustable thermal- magnetic release, including spreader terminals, phase barriers, thimbles of suitable size etc and making electric connections and taking down old unserviceable MCCB, complete all as specified and directed. Make: Legrand/ L&T&Indoasian/Havells. |
| 81 | S&F in replacement of AC box modular socket type with MCB SP 20 amps 10 KA operating on 240 volts AC all as specified and directed. Make : Havells 25 A DBOXX MCB Socket, DHDMCSN0251025 or Equivalent |
| 82 | Supply and fix in replacement of round recess mounted LED down lighter 9 Watt made of aluminium PDC with high lumen package for indoor application all as specified and directed |
| 83 | S&F in replacement of 1 module modular white cover plate with support frames all as specified and directed.Make:legrand Mylink or equivalent of Indo Asian/SSK/Anchor |
| 84 | S&F in replacement of 1 module modular metal flush box all as specified and directed.Make:legrand Mylink or equivalent of Indo Asian/SSK/Anchor |
| 85 | S&F in replacement of 3 module modular white cover plate with support frames all as specified and directed.Make:legrand Mylink or equivalent of Indo Asian/SSK/Anchor |
| 86 | S&F in replacement of 3 module modular metal flush box all as specified and directed.Make:legrand Mylink or equivalent of Indo Asian/SSK/Anchor |
| 87 | S&F in replacement of 4 module modular white cover plate with support frames all as specified and directed.Make:legrand Mylink or equivalent of Indo Asian/SSK/Anchor |
| 88 | S&F in replacement of 4 module modular metal flush box all as specified and directed.Make:legrand Mylink or equivalent of Indo Asian/SSK/Anchor |
| 89 | S&F in replacement of 6 module modular white cover plate with support frames all as specified and directed.Make:legrand Mylink or equivalent of Indo Asian/SSK/Anchor |
| 90 | S&F in replacement of 6 module modular metal flush box all as specified and directed.Make:legrand Mylink or equivalent of Indo Asian/SSK/Anchor |
| 91 | S&F in replacement of 8 module modular white cover plate with support frames all as specified and directed.Make:legrand Mylink or equivalent of Indo Asian/SSK/Anchor |
| 92 | S&F in replacement of 8 module modular metal flush box all as specified and directed.Make:legrand Mylink or equivalent of Indo Asian/SSK/Anchor |
| 93 | S&F in replacement of BLDC ceiling fan 1200 mm sweep of PCB Board complete all as specified and directed. |
| 94 | Supply, installation, testing and commissioning of 2x2 LED panel light fitting, 36W, complete with CRCA powder-coated housing and frame, opal polystyrene diffuser for uniform glare-free illumination, and integral constant current electronic driver. The luminaire shall be provided with inbuilt occupancy sensor for automatic switching based on human movement, with sensing range of 4–5 meters and coverage angle of approximately 110°. The fitting shall have IP20 protection and IK03 impact resistance, operating on 240V, 50Hz AC supply with wide voltage range (140V–280V), power factor ≥0.95 and THD ≤10%. The LED shall be of reputed make with CCT 6500K/455K, CRI ≥80 and minimum efficacy of 120 lm/W, suitable for indoor applications such as offices, hospitals, banks and commercial spaces, including all accessories, connections and mounting arrangements as required for proper operation all as specified and directed. |
| 95 | Supply and fixing replacement of MCCB, 415 volts, four pole of capacity 63 Amps, 25 KA, adjustable thermal- magnetic release, including spreader terminals, phase barriers, thimbles of suitable size etc and making electric connections and taking down old unserviceable MCCB, complete all as specified and directed. Make: Legrand/ L&T&Indoasian/Havells. |
| 96 | Supply, installation, testing and commissioning of 36W LED wall washer light fitting, complete with extruded die-cast aluminium housing and toughened clear glass front cover, suitable for outdoor applications with minimum IP65 protection. The luminaire shall be provided with high power LED chips (single colour/RGB as required) having minimum efficacy of 100 lm/W, CRI ≥80 and suitable beam angle (15°–60°) for uniform façade illumination. The fitting shall operate on 230V, 50Hz AC supply with inbuilt constant current electronic driver, power factor ≥0.9 and THD ≤10%. The luminaire shall be designed for continuous operation with efficient heat dissipation, complete with mounting brackets/clamps, stainless steel hardware and all accessories required for proper installation, suitable for architectural lighting of buildings, landscapes and external walls all as specified and directed. |
| 97 | Supply and fixing of decorative heritage-type wall-mounted light fitting consisting of cylindrical glass shade with black and gold finish metal body, complete with suitable lamp holder (E27/B22 type) for provision of LED lamp, designed to provide warm ambient illumination and elegant aesthetic appearance. The fixture shall be of heritage/contemporary design with high-quality glass shade and sleek finished housing, suitable for indoor applications such as corridors, bedrooms and lounges, complete with mounting base, brackets, screws, rawl plugs and all necessary accessories required for proper installation all as specified and directed |
| 98 | Supply and replacement of 40W flameproof LED tube light fitting of Crompton make, suitable for hazardous areas (Zone 1 & 2), complete with LED T8 tube, flameproof enclosure with protective guard and IP65 ingress protection. The fitting shall be CIMFR/PESO certified, suitable for gas groups IIA, IIB & IIC, operating on 150–270V, 50Hz supply. The 4 ft luminaire shall be wall mounted, including safe dismantling of existing fitting, installation of new unit, necessary wiring connections, testing and commissioning for proper operation all as specified and directed |
| 99 | Supply and fixing of electric meter box thermoplastic polycarbonate meter boxes IP65 in accordance with IEC60529, environment friendly, recyclable, UV resistant, halogen & silicon free, anti-acid & anti corrosive suitable for harsh environment with hinged transparent lid of suitable size to fix 1No three phase KWH meter and 1 No 3 phase 6 way DB. Note : rate shall deemed to be included in removing of three phase meter and refix in new meter box all as specified and directed. Make : Hansel/Sintex or equivalent |
| 100 | Maintenance / Repairs to cooling appliances, Refrigeration under 17 FBSU & its lodger units. |
| 101 | M&L Servicing of indoor unit of split type AC of 1.0 to 2.0 Ton Capacity of any make by air blowing, cleaning the filter in water and drying in sun, cleaning of drain tray and rectifying water leak, checking and tightening the electrical connection all as specified and directed. |
| 102 | M & L for servicing of outdoor unit of Split type air conditioner of 1.0 to 2.0 Ton capacity any make by compressed air and water washing, descaling of condenser coil and oiling of outdoor fan motor, checking and tightening of all the electrical connections, nuts, bolts, washers all as specified and as directed. |
| 103 | M & L for painting of outdoor unit of Split type air conditioner of 1.5/2.0 ton capacity any make including preparation of old painted surface complete and painting with one coat of Synthetic enamel paint complete in position all as specified and as directed. |
| 104 | M& L for stickering of MES/SM Nos on indoor and outdoor unit of any type of air conditioning in any location all as specified and directed. |
| 105 | M& L for Removing the Split type AC 1.0 ton to 2.0 Ton, by taking out from the existing position after pumping down gas from position with frame, outdoor / indoor unit carefully, shifting to new position, cutting opening wall of required size & fix in new position, topping up of gas and making good disturbed surface of wall opening by plastering and appling white wash including closing the old opening making good disturbed surface plastering and appling white wash all as specified and directed. |
| 106 | Supply and charge of gas R-410/R32 for inverter typre split AC of 1.0/1.5/2.0Ton capacity after leak testing and rectification of leak all as specified & directed. |
| 107 | Supply and charge of gas R22/R134a to Split AC, of 1.0/1.5/2.0 Ton capacity after leak testing and rectification of leak all as specified & directed. |
| 108 | M&L for taking out old unserviceable capillary and strainer from refrigerator and supply and fix new capillary & strainer of any capacity. All as specified and as directed. |
| 109 | All as per item No108above but for inverter type split AC and split type AC 1.0/1.5 /2.0 Ton capacity all as specified and directed. |
| 110 | Servicing of refrigerator by air blowing, cleaning of condenser coil, rubber bedding & checking and tightening the electrical connection all as directed of capacity 165 to 430 Ltrs all as specified and as directed. |
| 111 | Servicing of water cooler by air blowing, cleaning of condenser coil, checking and tightening the electrical connection, all as directed for water cooler of capacity 40/80 ltrs all as specified and as directed. |
| 112 | Supply and fix in replacement of outdoor capacitor 36 + 5% uFD all as specified and directed |
| 113 | Supply and fix in replacement of outdoor capacitor 46 + 5% uFD all as specified and directed |
| 114 | Supply and fix in replacement of outdoor capacitor 62 + 5% uFD all as specified and directed |
| 115 | Supply & replace timer switch for refrigerator of any capacity all as specified and directed. |
| 116 | Supply & replace bimetal switch for refrigerator of any capacity all as specified and directed. |
| 117 | Removing defective over load protector and supply and fixing new over load protector for Deep freezer/ refrigerator of any capacity and testing complete all as specified and as directed. |
| 118 | Supply and fix in replacement of defective fan motor with new fan motor suitable for water cooler/deep freezer of any capacity and testing complete all as specified and directed. |
| 119 | All as per No 118 above but for outer unit of split AC 1.5 Ton capacity all as specified and directed. |
| 120 | All as per No 118 above but for outer unit of split AC 2.0 Ton capacity all as specified and directed. |
| 121 | All as per No 118 above but for outer unit of inverter type split AC of 1.5 Ton capacity all as specified and directed. |
| 122 | All as per No 118 above but for outer unit of inverter type split AC of 2.0 Ton capacity all as specified and directed |
| 123 | All as per No 118 above but for inner unit of split AC of 1.5 Ton capacity all as specified and directed. |
| 124 | All as per No 118 above but for inner unit of split AC of 2.0 Ton capacity all as specified and directed. |
| 125 | All as per No 118 above but for inner unit of inverter type split AC of 1.5 Ton capacity all as specified and directed. |
| 126 | All as per No 118 above but for inner unit of inverter type split AC of 2.0 Ton capacity all as specified and directed. |
| 127 | All as per No 118 above but swing motor of split AC 1.5 /2.0 Ton capacity all as specified and directed. |
| 128 | M&L for rewinding of defective outdoor unit fan motor of split type AC 1.0/1.5/2.0 ton capacity any capacity and testing complete all as specified and directed. |
| 129 | Removing and Repairs to electronic control PCB (Normal) for split type AC 1.0/1.5/2.0 ton capacity of existing make all as specified and directed. |
| 130 | All as per item No 129 above but for inverter type split AC of 1.0/1.5 ton capacity (outdoor & indoor) of existing make all as specified and directed. |
| 131 | Supply and replace electronic control PCB for Smart Inverter Refrigerator all as specified and directed. |
| 132 | Supply and replace sensor / anti ice thermostat for split type AC of any model all as specified and directed. |
| 133 | Supply and replace remote unit for split type AC of any model all as specified and directed. |
| 134 | Supply and replace remote battery 1.5 Volts for split type AC of any model all as specified and directed. |
| 135 | supply and fix in repairs compressor suitable for split type AC 1.5 Ton capacity by removing unserviceable compressor after cutting the refrigerant line including supply and fixing new hermetically sealed compressor unit suitable to operate on 230 volt AC including connecting back the suction & discharge refrigerant lines, vaccumising charging of refrigerant testing and commissioning for smooth functioning all as specified & directed. |
| 136 | All as per item No 135 above, but for 2.0 Ton capacity all as specified and directed. |
| 137 | All as per item No 135 above, but for inverter type split AC of 1.5 Ton capacity all as specified and directed. |
| 138 | All as per item No 135 above, but for inverter type split AC of 2.0 Ton capacity all as specified and directed. |
| 139 | Supply and fix push tap CP brass, 15 mm suitable for water cooler of any capacity all as specified and directed. |
| 140 | Material and labour for repair of voltage stabilizer after removing the burnt out unserviceable winding cleaning the slots, insulate properly and rewinding transformer including testing of capacity 5 KVA, single phase, 230 V AC, 50 Hz all as specified and directed. |
| 141 | All as per item No 140 above, but of capacity 3/ 2 /1/0.5 KVA all as specified and directed |
| 142 | Material and labour for repair of voltage stabilizer by replacing time delay relay /main relay unit of voltage stabilizer with new of capacity 5 KVA, 4KVA including testing complete all as specified and directed. |
| 143 | All as per item No 142 above, but of capacity 3/ 2 /1/0.5 KVA all as specified and directed. |
| 144 | Supply and replace service valve for split type AC of 1/4\\" Size all as specified and as directed. |
| 145 | Supply and replace service valve for split type AC of 1/2\\" Size all as specified and as directed. |
| 146 | Supply and replace service valve for split type AC of 5/8\\" Size all as specified and as directed. |
| 147 | Supply & replace condenser unit for split AC of the following type and any make / capacity all as specified and as directed: |
| 148 | Ditto 1.5 Ton capacity |
| 149 | Ditto 2.0Ton capacity |
| 150 | Supply & replace outer body kit for split type AC of following capacities complete with condenser coil and fan motor complete of existing make all as specified and directed. Note: Compressor, condenser coils and fan motor will be measured and paid separately all as specified and directed. |
| 151 | Ditto 1.5 Ton capacity |
| 152 | Ditto 2.0Ton capacity |
| 153 | Supply and replace copper pipe 1/4\\"all as specified and as directed. |
| 154 | Supply and replace copper pipe 1/2\\"all as specified and as directed. |
| 155 | Supply and replace copper pipe 3/4\\"all as specified and as directed. |
| 156 | Supply and replace flair nut 1/4\\"all as specified and as directed. |
| 157 | Supply and replace flair nut 1/2\\"all as specified and as directed. |
| 158 | Supply & replace drain PVC pipe for split type AC including flushing of sludge / slime and rectification of Water leak any capacity all as directred. |
| 159 | Supply and replace PC Board of indoor for inverter type split AC of 1.5 to 2.0 ton capacity of existing make all as specified and directed |
| 160 | Supply and replace PC Board of outdoor for inverter type split AC of 1.5 to 2.0 ton capacity of existing make all as specified and directed |
| 161 | S & F Grill for enclosing the outer unit of air conditioners of any capacity all as specified and directed |
| 162 | Supply & fix flexible PVC pipe for drinking purpose of any dia suitable for any type of water cooler all as specified and directed |
| 163 | Supply & replace MS/GI bracket for fixing of outer unit of Air conditioners of capacity 1.5 ton/2.0 ton all as specified and as directed |
| 164 | Supply and replace Metal plug and socket with MCB 20 Amps and steel enclosure all as specified and as directed |
| 165 | Supply and replace MCB SP 5 to 30 Amps 230 Vall as specified and as directed |
| 166 | M&L for sub main wiring surface/ concealed type including cutting chases and making good in CM 1:3 complete with (2 runs of 4 Sqmm for phase and neutral and one run of 2.5 Sqmm for earth continuity) 1100 Volts grade PVC insulated unsheathed single core multistranded cable FR grade with copper conductor confirming to IS 694 drawn in conduit including provision of suitable dia PVC rigid conduit (medium grade) with conduit accessories such as bends, elbows, saddles all as specified and as directed. |
| 167 | Supply and replace thermo cool insulation for copper pipe for split type AC of any type and capacity.all as specified and as directed |
| 168 | Supply and replace unserviceable fan blade of outdoor unit fan motor of split type AC 1.0/1.5/2.0/ 3.0 ton capacity with new fan blade all as specified and directed. |
| 169 | Supply and replace of all filter of water cooler / purifier 'CANTT RO' or any type and capacity of existing make complete all as specified and as directed |
| 170 | Supply and installation of 1/2\\" PVC drain piping system for outdoor motor unit, including all necessary fittings and connections to ensure proper drainage of condensate water complete all as specified and as directed. Please Enable Macros to View BoQ information |