| 1 | Safe carriage of the following Centralised material from any Store Centre of PVVNL/Baghpat/Baraut to work site /JE store with loading & unloading at both ends respectively. |
| 2 | 11 KV Cable Jointing Kit (3x300 mm) Indoor |
| 3 | 11 KV Cable Jointing Kit (3x300 mm) outdoor |
| 4 | 11 kv Cross Arm |
| 5 | 11 KV Disc fitting |
| 6 | 11 KV Disc Insulator T&C type 4500kg. |
| 7 | 11 KV Disc Insulator T&C type with Fitting |
| 8 | 11 KV fuse Set |
| 9 | 11 KV LIGHTING Arrestor |
| 10 | 11 KV Pin insulator (Polymeric) |
| 11 | 11 KV Pin insulator With Nut |
| 12 | 11 KV TPMO With Polymeric Insulator |
| 13 | 11 kv VCB Incoming 600/300/5A 350 MVA |
| 14 | 11 kv VCB Outgoing 200/100/5A 350 MVA |
| 15 | 11/0.4 KV T/F 100 KVA |
| 16 | 11/0.4 KV T/F 25 KVA |
| 17 | 33 KV CT |
| 18 | 33 kv Fuse Set |
| 19 | 33 KV PT |
| 20 | 33 KV VCB 800A, 750MVA |
| 21 | ABC cable 3x50+1x35+1x16 sq mm |
| 22 | ACSR Rabbit Conductor |
| 23 | ACSR Weasel Conductor |
| 24 | control Cable 4x2.5 sqmm2 |
| 25 | Control Panel I/C For 33 Double T/F |
| 26 | Control Panel I/C For 33 Single T/F |
| 27 | Distribution Box Three Phase |
| 28 | Earthing Complete |
| 29 | LT PVC Cable Al 3.5x150/70 sq mm |
| 30 | PCC Pole 08.5 MTr |
| 31 | PCC Pole 11 MTr |
| 32 | Stay set Complete 16x1800 |
| 33 | XLPE Cable 3x300 sq mm |
| 34 | Proper Installation/Fabrication/laying/fixing/binding etc. of the above and Following Centralised Material With proper connection including All the Accessories and complete work in all respect (as per resspo norms and site requirement) (All work in the Contractor Scope with Carriage of material to different work site including loading & unloading at both ends respectively). |
| 35 | Making and Commissioning of 11 KV Cable Jointing Kit (3x300 mm) Indoor with proper connections and complete work in all respect as per site requirement. |
| 36 | Making and Commissioning of 11 KV Cable Jointing Kit (3x300 mm) outdoor with proper connections and complete work in all respect as per site requirement. |
| 37 | Fabrication and Fixing of 11 kv Cross Arm as per RESSPO Norms with complete work in all respect. |
| 38 | Fixing of 11 KV Disc fitting as per RESSPO Norms with complete work in all respect. |
| 39 | Fixing of 11 KV Disc Insulator T&C type 4500kg. as per RESSPO Norms with complete work in all respect. |
| 40 | Fixing of 11 KV Disc Insulator T&C type with Fitting as per site requirement. |
| 41 | Fixing of 11 KV fuse Set as per site requirement. |
| 42 | Fabrication, Fixing, Installation and commissiong of 11 KV LIGHTING Arrestor with proper connections and complete work in all respect as per site requirement. |
| 43 | Fixing of 11 KV Pin insulator with Pin (Polymeric) as per RESSPO Norms with complete work in all |
| 44 | Fixing of 11 KV Pin insulator With Nut as per RESSPO Norms with complete work in all |
| 45 | Fabrication, Fixing and Commissioning of 11 KV TPMO With Polymeric Insulator with proper grouting and concreting as per RESPO with complete work in all respect. |
| 46 | Installation and Commissioning of 11 kv VCB Incoming 600/300/5A 350 MVA with proper connections and complete work in all respect as per site requirement. |
| 47 | Installation and Commissioning of 11 kv VCB Outgoing 200/100/5A 350 MVA with proper connections and complete work in all respect as per site requirement. |
| 48 | Installation and Commissioning of New 11/0.4 KV, 100 KVA T/F Mounted on Plinth/Double Pole as per site requirement and providing & fixing of Lugs & copper L-piece (04 No.) of size 400x50x6mm and making of L.T.Connections with complete work in all respects. |
| 49 | Installation and Commissioning of New 11/0.4 KV, 25 KVA T/F Mounted on Plinth/Double Pole as per site requirement and providing & fixing of Lugs & copper L-piece (04 No.) of size 400x50x6mm and making of L.T.Connections with complete work in all respects. |
| 50 | Mounting, Installation and Commissioning of 33 KV CT on Double Pole Structure/Sub-Station Structure with proper connections and complete work in all respect as per site requirement. |
| 51 | Fixing of 33 kv Fuse Set as per RESSPO Norms with complete work in all |
| 52 | Mounting, Installation and Commissioning of 33 KV PT on Double Pole Structure/Sub-Station Structure with proper connections and complete work in all respect as per site requirement. |
| 53 | Installation and Commissioning of 33 KV VCB 800A, 750MVA with proper connections and complete work in all respect as per site requirement. |
| 54 | Laying, sagging, stringing and binding of ABC cable 3x50+1x35+1x16 sq mm with proper connections and complete work in all respect as per site requirement. |
| 55 | Laying, spreading, lifting and final sagging of 3 OR 4 phases ACSR Rabbit conductor in accordance with Line chart includidng binding and fixing of all accessories in 03Nos OR 04 Nos. Conductor in parallel as per site requirement. |
| 56 | Laying, spreading, lifting and final sagging of 3 OR 4 phases ACSR Weasel conductor in accordance with Line chart includidng binding and fixing of all accessories in 03Nos OR 04 Nos. Conductor in parallel as per site requirement. |
| 57 | Laying, sagging, stringing and binding of control Cable 4x2.5 sqmm2 with proper connections and complete work in all respect as per site requirement. |
| 58 | Installation and Commissioning of Control Panel I/C For 33 Double T/F with proper connections and complete work in all respect as per site requirement. |
| 59 | Installation and Commissioning of Control Panel I/C For 33 Single T/F with proper connections and complete work in all respect as per site requirement. |
| 60 | Fixing of Distribution Box Three Phase with proper connections and complete work in all respect as per site requirement. |
| 61 | Earthing Complete by MS earthing rod of 20x2500mm and 6 SWG Earthing wire etc as per site requirement. |
| 62 | Fixing and Connecting of LT PVC Cable Al 3.5x150/70 sq mm with proper connections and complete work in all respect as per site requirement. |
| 63 | Excavation of foundation pit in size of 75x45 cm. having depth of 1/6th of the full length of the support (pole), providing and laying of stone pad (300x300x75mm.) in the bottom of the pit. Erection of support (pole) For HT/LT Line and complete work as per RESSPO Norms.PCC Pole 08.5 Mtr. |
| 64 | Excavation of foundation pit in size of 75x45 cm. having depth of 1/6th of the full length of the support (pole), providing and laying of stone pad (300x300x75mm.) in the bottom of the pit. Erection of support (pole) For HT/LT Line and complete work as per RESSPO Norms.PCC Pole 11 Mtr. |
| 65 | Double pole structure with ST/PCC Poles :- Excavation of foundation pit in size of 75x45 cm. having depth of 1/6th of the full length of the support (pole), providing and laying of stone pad (300x300x75mm.) in the bottom of the pit. Erection of double pole For HT/LT Line and complete work as per RESSPO Norms.PCC 8.5Mtr/PCC 11Mtr./PCC 9Mtr/STP 11Mtr/STP 13Mtr Pole Please Enable Macros to View BoQ information |
| 66 | Double pole structure with ST/PCC Poles :- Excavation of foundation pit in size of 75x45 cm. having depth of 1/6th of the full length of the support (pole), providing and laying of stone pad (300x300x75mm.) in the bottom of the pit. Erection of double pole For HT/LT Line and complete work as per RESSPO Norms.PCC 8.5Mtr/PCC 11Mtr./PCC 9Mtr/STP 11Mtr/STP 13Mtr Pole Please Enable Macros to View BoQ information |