| 1 | WORK NAME |
| 2 | SITC of Amplifier + Digital Players 350+350 watts, 6 mic & 2 Aux input suitable for sbove speakers having following specification (1) suitable for AC 240 watt & 36V DC operation (2) Power output: 350 W RMS at 10 % THD/500WRMS Max. (3) input channels: Stereo Music Mode L/R 200mV/100k Line/ RIV/200k ohms, mic:6XMic 0.6 mV/4.7K ohms Aux: 2xAux100mV/470Kohms, (4) freq Pesp: 50-15000+3db (5) Tibe Controls: Bass+10db at 100Hz treble+10db at 10kHz (6) speaker output 4 ohms, 8 ohms, 70V & 100V For each zone (7) Digital players MP3 player with USB SD & MMC Card reader and remote control, (8) Din/wt: W510 x H185 x D470mm/ 40.0 kg.Make: Ahuja/ Focal Audio/ Philips/ ONIDA |
| 3 | Providing & Fixing Water proof high power LED lights 6x3=18 watts, single color warm white made out of stainless steel 304gr. Suitable to be fitted with emitter type power LED's with all in one optical lens of 85% effeciency step pempered glass 8 mm with protection class of IP-68. Fixture must be incompliance with BIS Standards and Trade mark Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (Color Design India/Wet design/Oase/complete as per the direction & entire satisfaction of Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached with BSR (ruidp sor 2023). |
| 4 | Supply installation commission & testing of out door garden speaker having following specification (a) Diameter of Done 10 inch (b) Diameter of stand (pipe) in M.S. Inch (c) polyclone tweet-peerless (Holland) 1 inch (d) polypropylene woofer – Iwai (german) 6.5 inch (e) power handing 50 watt RMS (f) impedance 8 ohms nominal (g) sensitive 89 db/w/m (h) Frequency response 65Hz to 18KHz (i) Operation relativr humidity 99% (k) Body material Lexan polycarbonate with S.S. fitting (I) LMT 100v (m) Colour of speakers Dark green, Black, yellow & red (n) Colour of pipe as per requirement to much the speakers. Garden peaker are totally weather proof unbreakable & UV proof Each speaker will be mounted on 50mm dia MS pipe dully painted with PU paint marching colour of speaker having lenth 3 mtr. And suitably grouted in ground with C.C. 1:3:6 in round shape foundation Complete in all respect but without light.,MAKE: Ahuja/ Focal Audio/ Philips. |
| 5 | WORK NAME |
| 6 | Providing & Fixing of IK10 IP65 protected 600 mm height LEDBollard Luminarie with base plate made of powder coated die castalluminium housing with UV stabalized PC diffuser. The Systemlevel Luminous efficacy ≥ 90 Lumen/W. SMD LEDs is to be used,System CRI>70, CCT: 3000/4000/6500 K. The integral electronicdriver must be potted & has a unique BIS R number must be potted& has a unique BIS R number constant current and Internal/externalsurge protection device of min. 4KV(L-N) and efficiency > 85%,PF>0.9, THD<20% and input Voltage range of 90-270V AC at 50Hz.System life of 30000 Burning hours with 70% of Initial Lumensmaintained Light output in Cool white or Warm White Colour as perengineers choice. driver current <750mA. Fixture must be incompliance with BIS Standards and Trade mark Certificate completein all respect.OEM Must have its own in house NABL lab setup forall testing facilities for LED fixtures. (LM79/LM80) Certificate/report with liable warranty of product/accessories from OEM shall besubmitted. All as per pre approved by Engineer in-charge. Foradditional technical parameters of products/ work , refer Annexure\\"A\\" attached with this BSR . Minimum lumen output 980 lm Bollard |
| 7 | Providing & Fixing of IK08 IP65 protected Top/Bottom mounted LEDPost top Luminarie made of single piece construction powdercoated die cast alluminium housing with UV stabalized Clear /frosted Polycarbonate diffuser and Aluminium anodised with sandblast reflector. The System level Luminous efficacy ≥ 100 Lumen/W.SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K.The integral electronic driver must be potted & has a unique BIS Rnumber must be potted & has a unique BIS R number constantcurrent and Internal/external surge protection device of min. 4KV(LN) and efficiency > 85%, PF>0.9, THD<10% and input Voltagerange of 140-270V AC at 50Hz. System life of 50000 Burning hourswith 70% of Initial Lumens maintained . Driver current <750mA.Fixture must be in compliance with BIS Standards and Trade markCertificate complete in all respect.OEM Must have its own in houseNABL lab setup for all testing facilities for LED fixtures.(LM79/LM80) Certificate/ report with liable warranty ofproduct/accessories from OEM shall be submitted. All as per preapproved by Engineer in-charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached withthis BSR . |
| 8 | Providing and Laying RCC Foundation for Octagonal / ConicalStreet Light poles, High mast Poles as per Drawing attach at TableP-4 with Following Procedure & All as per pre approved byEngineer in-charge. For additional technical parameters of products/work , refer Annexure \\"A\\" attached with this BSR .A) Excavation of Pit for Foundation Size upto required depth fromGround levelB) Dressing of Pit and Dry stone pitching 200 mm thick includingsupply of stones and preparing surface complete.C) Providing and laying in position cement concrete of M-10 grade of75 mm thicknessD) Reinforcement for R.C.C. work with TMT bars includingstraightening, cutting, bending, placing in position and binding allcomplete.E) Centring and shuttering including strutting , propping etc. andremoval of form work for Footing and PedestalF) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe &Foundation Bolt with template as per OEM Recommendations.G) Providing and Laying Reinforce cement Concrete of M-25 gradein Footing and Pedestal including Curing the foundation for 7 days.H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2no. 100 mm long, 10 mm dia. Lugs on each face. |
| 9 | Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR. Electrolytic grade Aluminium bus bar 6010 grade |
| 10 | Providing & Fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . One day reserve (Analog type ) |
| 11 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2:2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage 690V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, |
| 12 | Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR. 40 Amp |
| 13 | 70 Amp |
| 14 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in- charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Four pole MCB (With B/C curve tripping Characteristics) 40 A rating |
| 15 | 80 A rating |
| 16 | Providing & Fixing of 240/415 V isolator ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilizationcategory, 4KV impulse withstand voltage, true contact indication,Red colour dolly / lever shall have single mould covering overallpoles for operation , two position din rail mounting, minimum phasetermination capacity of 35sq.mm. IP 20 contact protection and fittedin existing distribution board / sheet including making connections,testing etc. as required. OEM shall have submit NABL / CPRI /ERDA accrediated lab type test reports & All as per pre approvedby Engineer in-charge.For additional technical parameters of product/ work refer Annexure 'A' attached with this BSR 80 A/ 100 A rating |
| 17 | 40 A rating |
| 18 | labour charges for Excavating trenches of required width for pipesdressing of sides, ramming of bottoms, depth up to 1.5 Mtr. includingtaking out the excavated soil, and then returning the soil as requiredin layers not exceeding 20cm in depth including consolidating eachdeposited layer by ramming, watering etc. and disposal of surplusexcavated soil as directed within a lead of 50 Mtr.: All kind of Soils |
| 19 | Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in-charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 20 | Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 25mm x 3mm Alum. Strip |
| 21 | Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing on die cast housing to allow traceability/ authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR. High Power LED Flood Light Minimum lumen output 8700 lm |
| 22 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work : 20 mm dia. nominal bore |
| 23 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore |
| 24 | Providing and fixing PTMT pillar cock of approved quality and colour 15mm nominal bore, 107mm long. Weighing not less than 110 gms. |
| 25 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore |
| 26 | G.I. tees (equal) 25 mm |
| 27 | G.I. elbows 20 mm dia |
| 28 | G.I. Union 20 mm nominal bore |
| 29 | Supply of P.V.C. hose pipe 38 m dia at site/ store i/c all complete |
| 30 | P/Laying ISI marked P.V.C. insulated submersible cable confirmingto(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire shouldbe made from 99.90 % purity copper, stranding in acc. toIS:8130/IEC 60228 for lower watt loss , oxygen free for lesschances of oxidization, insulation PVC type A/C/D , flame retardantas per IS 10810-53, better amperage rating as per IS:3961 part 5,existing pipe / open trench / Cable tray / on surface including makingconnection etc. as required. For additional technical parameters ofproduct / work refer Annexure 'A' attached with this BSR 6.0 Sq.mm 3 core flat / Round |
| 31 | Supply and laying speaker cable of IS/ISO 9001 CERTIFIEDCOMPANY made following size 2 core twin twisted multi strandedelectrolytic grade copper conductor, overall PVC insulated andarmoured cable (Blue colour) on surface/ above false ceilingincluding cost of GI spacers, saddles etc. as required. For additionaltechnical parameters of product / work refer Annexure 'A' attachedwith this BSR 1.0 Sq. mm |
| 32 | Providing, Fixing, Jointing, Testing & Commissioning of Heavy dutyMS 'C ' class (Heavy) pipes conforming to IS 3589 / 1239 part-I forhydrant and sprinkler applications including cutting, screwing,welding etc. & forged steel fittings like elbows, tees, tapers, reducer,gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps,hanger and nuts bolts including cutting hole and chase in brick orRCC walls/ slab and making good the same. complete with paintingof one coats of Red Oxide and two or more coats of syntheticenamel paint of required shade complete as required. (Pipe to betested @ 10Kgf/Sqcm for 2 Hrs.). All as per pre approved byEngineer in-charge. For additional technical parameters of products/work , refer Annexure \\"A\\" attached with this BSR . |
| 33 | Supplying and Fixing of Brass/GM gate valves with screwed end ,Non rising stem and conforming to IS:778 Class-1 including teflontape etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of products/ work , referAnnexure \\"A\\" attached with this BSR 40 mm dia |
| 34 | Supplying & fixing SS-304 Short Branch Pipe conforming to IS:903:93 fitted with 20mm (nominal internal diameter) bore nozzle, forprojecting water in form of solid jet. The Branch shall have 63mmMale Instantaneous Inlet, suitable for use with 63 mm size Firefighting hoses. H.P. tested to 21 kgf/cm² for 2.5 minutes. All as perpre approved by Engineer in-charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached withthis BSR . |
| 35 | Supply & Laying following size' B ' class , G.I. Pipe confirming to IS :1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for layingearth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in-charge. (Earth Excavationwill be Paid Extra)All as per pre approved by Engineer in-charge.For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 15 mm dia |
| 36 | 20 mm dia |
| 37 | 50 mm dia |
| 38 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 39 | P / L of Double wall corrugated HDPE pipe confirming to IS : 16205P-24, Stiffness Class 750 N, Externally corrugated and havingsmooth surface inside with HDPE Coupler, Elbow, Tee at requiredDepth below the ground for laying cable of following Nominal Outerdia. MFR Test report from NABL accrediated is to besubmitted.(Excavation of Earth & Back filling with compaction is tobe Paid Extra)All as per pre approved by Engineer in-charge. Foradditional technical parameters of products/ work , refer Annexure\\"A\\" attached with this BSR . 50 mm |
| 40 | Supply & fabrication steel structure with MS channel / angle / joist /ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , onecoat of primer & two coat of enamel paint etc. as required completein all respect. All as per pre approved by Engineer in-charge. Foradditional technical parameters of products/ work , refer Annexure\\"A\\" attached with this BSR . |
| 41 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10kA breaking capacity (B/ C/D tripping characteristic as per type ofload and site requirement) 4 KV impulse withstand voltage, ISImarked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC, minimum phase termination capacity of35sq.mm. , conductor line load reversibility , IP 20 contact protectionand fitted in existing distribution board/sheets, minimum electricaloperation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80A & above rating including making connections, testing etc. asrequired. OEM shall have submit NABL / CPRI / ERDA accrediatedlab type test reports & All as per pre approved by Engineer incharge. For additional technical parameters of product / work referAnnexure 'A' attached with this BSR 0.5 A to 5 A rating(Double pole MCB(With B/C curve tripping Characteristic ) |
| 42 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathedArrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P -I of 1.1 KV with H4- Grade electrolytic aluminium conductorconfirming to IS 8130 of purity >99.6 %, round / flat strip armouringof cables, Inner / outer sheath confirming to IS:5831 in existing RCC/ Hume / Stoneware / PVC pipe/ open duct/cable trench / Cabletray(with cable tie) including testing etc. as required of followingsize. OEM must have it's own in house NABL accrediatedLaboratory for testing procedure as per IS:10810.For additionaltechnical parameters of product / work refer Annexure 'A' attachedwith this BSR 6.0 Sq. mm 2 core |
| 43 | 16.0 Sq. mm 2 core |
| 44 | 50.0 Sq. mm 3.5 core |
| 45 | Decorative haritage pole in 4 Meter height. Pole upper section oflength 3mtr is of dia 76mm and 1 meter bottom section of dia114mm with decorative casting with base plate as per drawing.Provision for inside termination box with 4way connector & 1nos 6AMPS MCB for local isolation with cover.Complete in all aspectswith foundation bolts. |
| 46 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 2 x 1.5 sq.mm |
| 47 | 80 mm dia CI butterfly valve PN 1.0 |
| 48 | SITC of IP-42 and general construction confirming to IS:8623 : 1993,wall/ free standing floor mounted dust and vermin proofcompartmentalised cubical panel as specifications and Otherparameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) asbelow:-(a)Thickness of CRCA sheet shall be 2.0 mm, cable alleycompartments having concealed hinged type doors with key typelock with / without detachable extension type structure. Removable3 mm. thick sheet steel gland plates with appropriate size ofknockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Waterrinsing, Activation, derusting, pickling in acid bath, phosphatising &shall be subjected to nine tank process and then Powder coated withapproved shade of minimum 70 microns on both side of panel. Thepanel having PE foam/ Neoprene rubber gasket of not less than3mm thickness ,required hardware , concealed hinged door with keytype locking arrangement for equipment/switchgear earthed with 2.5sq.mm braided copper wire.[c) Interconnection between bus bar and switchgears /cable shallbe rigidly supported and made out by flexible copper wires (up to 63amp ) and by solid bus bar (>63 amp ) . control wiring will be carriedout with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5sq.mm flexible copper wire only. All joints / interconnections ofcopper bus bar shall be dully tinned . Clearance between main busbar and risers / metal parts shall be at least 10 mm additional towidth of bus bar Bus bar is insulated by Heat Shrinkable sleeves .Earth and Neutral bus bar shall be half of the size of phase bus bar.( Cost of Bus bar / Flexible wire for Interconnection between Mainbusbar and Switchgear is to be Paid Extra )(d)Wiring between components within switchgear and Incoming /outgoing cable shall be done through the terminal block only. Directconnection shall not be permitted. Each terminal block shall be onepiece moulded, barrier type, 650 volt grade, complete with washers,heads, studs with two nuts and identification strips and shall haveadequate continuous current rating. For tap-offs, adjacent terminalswith shorting strips shall be used. 10% Spare terminal blocks shallbe provided. Wire identification on marking strip shall correspond tothe designation of the wiring diagrams. All wire terminals on theequipment shall also be marked with designation corresponding tothose of the wiring diagram.(e)All wiring shall be enclosed in plastic channels and neatlybunched and closed in metering chamber, Wiring between terminalsof various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels,adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm ( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and Highvoltage Power frequency test (by applying a voltage of 2.5KV for oneminute) shall be measured between phases, between phase andneutral and between phase and earth. both before and after highvoltage power frequency test. The insulation resistance shall not beless than three megaohm. CT Secondary current injection test shallalso be carried out.(h) only outer surface area on all sides shall be measured & panel tobe fabricated only from CPRI approved fabricator only (CPRI Testcertificates to be submitted)All as per pre approved by Engineer incharge. For additional technical parameters of products/ work , referAnnexure \\"A\\" attached with this BSR . |
| 49 | Providing & Fixing of HDPE pipe Confirming to IS:4984:2021 forwater supply suitable for submersible & jet pump with requiredfittings ie socket, elbows, tee etc. complete in all respect. All as perpre approved by Engineer in-charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached withthis B for Horizontal installation 40 mm OD 4kg/ cm2 |
| 50 | SITC of Single Stage, water cooled, High Speed (2880 RPM),Horizontal, Centrifugal, Openwell Submersible pumps set pre filledwith coolent water and fitted with mechanical seal - T/C Vs T/C,Thrust bearing shall be of carbon + S.S.The stator body of singlephase pump shall be of SS and rest of all shall be of cast iron. Allcasting parts should be cathod electro deposition (CED) coated andother construction material should be confirming to IS : 14220: 2018. The overall performance of pump shall confirm to BEE energyefficiency level of 3 star. Valid BEE certificate from OEM must besubmitted for the same. Motor should be IE2 class as per IEC60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011, includingmaking connection etc as required complete in all respect. OEMshall have submit NABL / CPRI / ERDA accrediated lab type testcertificate before execution. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work ,refer Annexure \\"A\\" attached with this BSR . 2.0 HP, 1-Ø, (12 -25) Mtr, (350 - 115) LPM |
| 51 | 10.0 HP, 3-Ø, (22 -36) Mtr, (1860 - 1020) LPM |
| 52 | Providing & Fixing of thermoplastic Polycarbonate cable junctionboxes with IP66 rating of protection & knock out for cable entry/outof following sizes including clamps for holding the box, including costof DIN rail for MCB mounting, 10 Sqmm 4 pole connectors for cablesterminals, threaded cable glands made of polyamide material etc.complete in all respect. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work ,refer Annexure \\"A\\" attached with this BSR . 175mm X 150mm X100mm Please Enable Macros to View BoQ information |