| Sl. No. | Item Description |
| 1 | Please enter GST in Percentage on Total amount of BoQ2 |
| 2 | Please enter GST in Percentage on Total amount of BoQ3 |
| 3 | 01 GAIL Ashiyana - % rate |
| 4 | Renovation & Developmental Works at GAIL Ashiyana |
| 5 | Dismantling & Demolishing Works |
| 6 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres leadFor thickness of tiles above 25 mm and up to 40 mm |
| 7 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - chargeNominal concrete 1:3:6 or richer mix (including equivalent design mix) |
| 8 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 9 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 10 | Excavation & Earth Work |
| 11 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. |
| 12 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. |
| 13 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundationtrenches, plinth, sides of foundation etc. complete for all lift. |
| 14 | Concrete Works |
| 15 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 16 | 1:1ยฝ:3 (1 Cement: 1ยฝ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 17 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 18 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 19 | Structural Steel Works |
| 20 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer and two coats of synthetic enamel paint, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 21 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer and two coats of synthetic enamel paint using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 22 | External Development & Finishing Works |
| 23 | Providing & Laying Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Light shade pigment using white cement |
| 24 | Providing and laying at or near ground level factory made kerb stone of M- 25 grade cement concrete in position to the required line, level and Curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 25 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge60 mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. |
| 26 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of jointsetc. complete :150 mm dia. R.C.C. pipe |
| 27 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved byEngineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved |
| 28 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 29 | 03 GAIL Bhawan - Civil & Interior - % rate |
| 30 | MARBLE & GRANITE WORKS |
| 31 | Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately, however if the stone is to be fixed on cement mortar than the payment shall be made fully in this item) Base Rate of Stone: Rs. 500 per SqFtEquivalent Shades or as per approval by EIC FOR WHITE MARBLE - luxurious marble like Statuario Marble, Calacatta Borghini, Michelangelo Marble - FOR BLACK MARBLE - Nero Marquina Marble, Bhainslana Black Marble (Rajasthan), Zebra black marble |
| 32 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 33 | Marble work |
| 34 | Granite work |
| 35 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
| 36 | STEEL WORK |
| 37 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 38 | Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required |
| 39 | In stringers, treads, landings etc. of stair cases including use of chequered plate wherever required, all complete. |
| 40 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 41 | Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.10 x 60 mm |
| 42 | FLOORING WORK |
| 43 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 44 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 45 | Glazed vitrified floor tiles polished finish of size Size of Tile 600 x 1200 mm |
| 46 | Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm |
| 47 | ROOFING & FALSE CEILING WORKS |
| 48 | Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size underdeck on ceiling surface, complying with ISO 4898:2008 & ASTM C 578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of > 350 kPa listed as per ASTM D 1621, density of 34-36 kg/cum as per ASTM D 1622, water absorptions < 1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576. Fire retardent property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, fixed with suitable water based adhesive and fastener, complete in all respect as per the direction of Engineer-in-Charge. |
| 49 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square |
| 50 | 12.5 mm thick tapered edge gypsum moisture resistant board. |
| 51 | Fully Perforated Gypsum Plaster Board of size 1200 x 2400 x 12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in-charge and as per manufacturer's specification, with all 4 sides tapered and backed by acoustical tissue with NRC value not less than 0.60. |
| 52 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. |
| 53 | FINISHING WORK |
| 54 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 55 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.New work (two or more coats) over and including waterthinnable priming coat with cement primer having VOC content less than 50 gram / litre |
| 56 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 57 | With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre |
| 58 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 59 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 60 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 61 | DISMANTLING & MISC. WORKS |
| 62 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar |
| 63 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 64 | For thickness of tiles 10 mm to 25 mm |
| 65 | For thickness of tiles above 25 mm and up to 40 mm |
| 66 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 67 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer- in-charge. |
| 68 | Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. Door chowkhats |
| 69 | Fixing chowkhat in existing opening in brick / RCC wall with dash fasteners/Chemical fasteners of appropriate size (3 nos on each vertical member of door chowkhat and 2 nos on each vertical member of window chowkhats), including Cost of dash fasteners/ chemical fastener. |
| 70 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 71 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. Note - item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more. |
| 72 | EXTERNAL DEVELOPMENT WORKS |
| 73 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as per direction of Engineer-in-Charge60 mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. |
| 74 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 75 | 05 GAIL Bhawan - Electrical - % rate |
| 76 | ELECTRICAL WORKS |
| 77 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) |
| 78 | 6 way (4+18), Double door |
| 79 | 8 way (4+24), Double door |
| 80 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 81 | 63 amps |
| 82 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 83 | Supplying and fixing following rating, four pole, three phase and neutral, 415 volts, residual current circuit breaker ( RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required. |
| 84 | 63 amps |
| 85 | 40amps |
| 86 | CABLING WORK. |
| 87 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 88 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 89 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 90 | Cable Termination : |
| 91 | Supplying & Making end terminations with brass compression glands and aluminium lugs for following size of PVC insulated/ PVC sheathed/ XLPE Aluminium conductor cables of 1.1 KV grade as required |
| 92 | 4 x 10 sqmm |
| 93 | 4 x 16 sqmm |
| 94 | Cable Trays & Raceways |
| 95 | Supplying and installing following size of perforated pre-painted M.S cable trays with cover and with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required. |
| 96 | 300 mm width X 50 mm depth X 1.6mm thickness |
| 97 | 150 mm width X 50 mm depth X 1.6mm thickness |
| 98 | Supplying and installing following size of perforated pre-painted M.S cable trays bends with cover and with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required. |
| 99 | 300 mm width X 50 mm depth X 1.6mm thickness |
| 100 | 150 mm width X 50 mm depth X 1.6mm thickness |
| 101 | Supplying and installing following size of perforated pre-painted M.S cable trays Tee's with cover and with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required. |
| 102 | 300 mm width X 50 mm depth X 1.6mm thickness |
| 103 | 150 mm width X 50 mm depth X 1.6mm thickness |
| 104 | Supplying and installing following size of perforated pre-painted M.S cable trays cross members with cover and with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required. |
| 105 | 300 mm width X 50 mm depth X 1.6mm thickness |
| 106 | 150 mm width X 50 mm depth X 1.6mm thickness |
| 107 | Cabling & Wiring |
| 108 | Supply & Fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 109 | Point Wiring : |
| 110 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated multi stranded flexible copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.Group โ C |
| 111 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group โ C |
| 112 | Circuit & Submain Wiring |
| 113 | Supply & Fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 114 | 25 mm |
| 115 | 32 mm |
| 116 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 117 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 118 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 119 | Supplying & Fixing following modular Switches/Sockets on the existing modular plate & switch box inlcuding connections but excluding modular plate etc. as required |
| 120 | 5/6 A Switch |
| 121 | 15/16 A Switch |
| 122 | 3 pin 5/6 A Socket Outlet |
| 123 | 6 pin 15/16 A Socket Outlet |
| 124 | Supplying & Fixing following size/ modules, GI/PVC Box with modular base & cover plate for modular switches in recess etc. as required. |
| 125 | 1 or 2 module |
| 126 | 3 module |
| 127 | 4 module |
| 128 | 6 module |
| 129 | 8 module |
| 130 | 12 module |
| 131 | 07 GAIL Alaya Works C&I - % rate |
| 132 | CIVIL & INTERIOR WORKS SOR |
| 133 | Demolishing & Dismantling Works |
| 134 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 135 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 136 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar |
| 137 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 138 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. of all sizes and shape complete and stacking within 50 metres lead |
| 139 | Dismantling G.I. pipes of all size (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : |
| 140 | Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge:Upto 150 mm dia |
| 141 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres leadFor thickness of tiles above 25 mm and up to 40 mm |
| 142 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 143 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 144 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:G.S. Sheet |
| 145 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 146 | Dismantling of Existing waterproofing manually / by mechanical means and disposal of material outside the premises as per direction of Engineer-in-charge(brick bat coba/ app membrane/fiber membrance etc.) |
| 147 | Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead :Thickness above 10 mm up to 25 mm |
| 148 | Flooring, Counters & Misc. Works |
| 149 | Providing & Laying Anti Skid Glazed Digital Vitrifed Tiles (Premium Series Italian Finishes) in Floor/Skirtings/Walls with different sizes (thickness to be specified by Manufacturer), with water absorption less than 0.08% and conforming to IS 15622, of approved brand and manufacturer, in all colour and shade, laid with cement based high polymer modified quick tile adhesive of approved brand (water based) conforming to IS: 15477, in average 6-15 mm thickness including grouting of joints with epoxy based tile grout of approved make.Size of Tile: 1200x600/1000x1000 mm or any other size as per the directives of EIC/GAIL Base Rate of Tile: Rs. 120/- per Sq.Ft approx. (Make: RAK/Kajaria/Somany/Johnson) |
| 150 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab colour of Cherry/Ruby Red, Zed Black, Steel Grey, Tan Brown or as per the decision of EIC |
| 151 | Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for walls, kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Granite stone slab of colour black, Cherry/Ruby red, Zed Black, Steel Grey, Tan Brown as per the decision of EIC |
| 152 | Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 153 | Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. |
| 154 | Providing and fixing machine cut, mirror/ eggshell polished , Marble stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge.18 mm thick Italian Marble stone slab of any color shade and pattern as approved by EIC Base Rate of Italian Marble: Rs. 500/- per SqFt |
| 155 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm |
| 156 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling/ grouting and finishing complete as per direction of Engineer-in-charge. |
| 157 | Providing edge moulding to 18 mm thick marble stone/ granite stone etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 158 | Ceiling Works |
| 159 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mminterval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction ofthe Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum moisture resistant board |
| 160 | Wood Work |
| 161 | French spirit polishingTwo or more coats on new works including a coat of wood filler |
| 162 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. Thefinal melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) |
| 163 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood |
| 164 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 165 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulusof elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction ofEngineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.Frame size 50 x 125 mm |
| 166 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheathusk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread offlame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butthinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge.(Note: stainless steel butt hinges and necessary S.S screws shall be included in the item)35 mm thick |
| 167 | Composite solid plain white color board for backing of cup boards and bathroom/kitchen cabinets etc. of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/ mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel screws etc. all as per direction of Engineer-In-Charge. 12 mm thick |
| 168 | Providing and fixing 18 mm thick, 150 mm wide pelmet of coir veneer board ISI marked IS : 14842, including top cover of 6 mm coir veneer board, nickle plated M.S. Pipe 20 mm dia. (heavy type) curtain rod with nickel plated brackets, including fixing with 25x3 mm M.S. Flat 10 cm long fixed to pelmet with hollock wood cleats of size 100 mm x 40 mm x 40 mm on both inner side of pelmet and rawl plugs 75 mm long etc. all complete. |
| 169 | Extra for using veneered particle board conforming to IS 3097 Grade I, in item of pelmet 18 mm thick 150 mm wide.Particle board with decorative veneering on both sides |
| 170 | Providing and fixing teak wood lipping of size 25x3 mm in pelmet. |
| 171 | Painitng & Wall Dรฉcor |
| 172 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre |
| 173 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 174 | Providing and applying plaster of paris putty (interior grade) of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 175 | Glass Slider, Window & Ventilator Works |
| 176 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mmfor Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (whereever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixinghardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately.Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for :(i) Sites with basic wind speed > 45 m/sec as per IS 875 โ Part 3(ii) Sites with structure height more than 20m for all wind speeds |
| 177 | Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.Using R3 series with frame (98 mm & above) x (40 mm & above) & both glazed and fly screensash (30 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handleon every glazed panel along with multi-point locking system. (Height upto 1.8m). |
| 178 | Fixed window / ventilator with mullion / transom.Using R1 series with frame (33 mm & above ) x (35 mm & above) & mullion (33 mm & above)x (50 mm & above). (Height upto 0.90 metre) |
| 179 | Casement Window with Double Rebate Frame with two Side Hung Glazed Panel on outside and two Side Hung wiremesh Panel on inside and French (False) Mullion with S.S. 304 friction hinges as per size and weight of sash, multipointlocking system, zinc alloy (zamak) powder coated handles with shoot bolt on both glazed and fly screen panel.Using R3 series with frame (110 mm & above) x (45 mm & above) & glazed sash (55 mm & above) x (65 mm & above) & fly screen sash (30 mm & above) x (55 mm & above) & French (False) mullion (55 mm & above) x (60 mm& above) & metal grill (if required to be paid separately). (Height upto 1.8 metre). |
| 180 | Casement window single panel with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system,zinc alloy (zamak) powder coated handles.Using R3 series with frame (55 mm & above ) x (45 mm & above) & sash (55 mm & above) x (65 mm & above). (Height upto 1.8 metre) |
| 181 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazedshutters 25 mm to 40 mm thick :Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4 mm wide aperture with matching wood beading |
| 182 | Supply & Fixing 6 mm Clear Toughenend Glass in Windows and Ventilators (weight not less than 12.50 kg/sqm). |
| 183 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.Upto 5mm depth and 5 mm width |
| 184 | Civil Works |
| 185 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.All kinds of soil |
| 186 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed by EIC exceeding 80 mm dia. but not exceeding 300 mm dia |
| 187 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering |
| 188 | Carriage of Earth by mechanical transport including loading, unloading and Stacking including royalty & carriage up to 5 KM complete. |
| 189 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 190 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to any lead outside the periphery of the area cleared. |
| 191 | Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 192 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 193 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 194 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half AAC Block Masonry. |
| 195 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to VI floor level : |
| 196 | 1:1ยฝ:3 (1 Cement: 1ยฝ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 197 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 198 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 199 | 12-15 mm cement plaster on brick walls/concrete columns/ concrete slabs with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) |
| 200 | ShutteringCentering and shuttering including strutting, propping etc. and removal of form for all heights and at all level, Foundations, footings, bases of columns, Columns, Pillars, Lintels, beams, plinth beams, floors, roofs, stairs, coping, projections, walls, shelves etc. for concrete. |
| 201 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil |
| 202 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 203 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 204 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 205 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry |
| 206 | External Works |
| 207 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufactureMake: Asian (Apcolite)/Nerolac (Satin)/Berger (Luxol) |
| 208 | Crack Filling Carrying out the filling of all Major Cracks in the external Plaster up to 10 mm width to be cut in 'V' shape with cutting machine, wash to remove loose particles by providing & applying Dr. Fixit Crack-X Shrink free or Nerolac Perma Crack Filler or equivalent Crack filling Compound for all level and height. Work to be executed as per manufacturer specification, rates includes cost of labour, material, machines etc. all complete.(Make: Pidilite/Nerolac Perma/Asian/Berger) |
| 209 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1cement: 4 coarse sand)Note: For case where plaster thickness required is more than 20 mm and upto 50mm, additional one coat of plaster/plaster reapir shall be payable as per the instructions of EIC. |
| 210 | Supplying and Applying Asian smart care Damp proof advance or Equivalant as per list of makes of self primer at 30 % dilution and forced coverage of 10 Sq.Ft./Ltr. on horizontal surface and 25 Sq.Ft/L on vertical surface. Laying layer of Fibre glass cloth when the primer layer is still green/wet. Overlaps of joints of fibre cloth should not be less than 10 cm. After drying apply first coats of Smart Care Damp Proof without any dilution at forced coverage of 25 Sq.Ft./Ltr. After drying apply Final coats of Smart Care Damp Proof without any dilution at forced coverage of 25 Sq.Ft./Ltr. Scope include cleaning of existing surface with a solution of bleaching powder. |
| 211 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in- charge. The product performance shall carry guarantee for 10 years against any leakage. |
| 212 | For vertical surface two coats @0.70 kg per sqm |
| 213 | For horizontal surface one coat @1.10 kg per sqm. |
| 214 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately).Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 215 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 216 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. The item also includes painting with synthetic enamel paint 2 or more coats of approved color, brand and shade as per the directives of EIC. |
| 217 | Providing and applying plaster of paris putty (exterior grade) of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 218 | Micro-ConcreteConcreting with approved brand of micro-concrete mixture (Dr. Fixit Micro Concrete or Eq as per List of Makes) as per manufacturers technical specifications and applying at desired places including labour to a thickness 50 mm. Cost of shuttering & scaffolding to be paid for separately. |
| 219 | Carrying out structural/surface repairs by providing and applying Dr. Fixit Polymer Mortar HB(or equivalent as per list of makes) in layers of 20 mm per layer to the rusted concrete with a bonding coat on each layer as per the manufacturers specifications. Each layer to be casted post 24 hours of casting of previous layer. |
| 220 | Carrying out the structural repairs by providing and applying Dr. Fixit rust remover Epoxy Zinc Primer or Eq as per List of Makes including providing and applying Dr. Fixit Zinc Epxoy Primer to the rusted reinforcement as per the manufacturers specifications to a maximum height of 4 m from the available surface level. |
| 221 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer In charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. |
| 222 | Extra for Providing & Applying Dr. Fixit Pidicrete URP or equivalent as per list of makes in proportions as per manufacturers specifications in cement plaster for wall waterproofing works. |
| 223 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. |
| 224 | Providing and supplying Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Medium shade pigment using 50% white cement 50% Grey cement |
| 225 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4 mm thick aluminium composite panel material consisting of 3 mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5 mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shadeon face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. |
| 226 | (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts allcomplete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtainwall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shallprovide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for thepurpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. |
| 227 | 10 GAIL Alaya - Plumbing- % rate |
| 228 | GAIL ALAYA - PLUMBING WORKS BOQ |
| 229 | External/Internal Drainage Providing and fixing soil, waste and vent pipes |
| 230 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 231 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. |
| 232 | Single Push fit coupler 110 mm dia |
| 233 | Single Tee with door 110x110x110 mm |
| 234 | Bend 87.5 Deg 110 mm dia |
| 235 | Shoe (Plain) 110 mm dia |
| 236 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 237 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm dia |
| 238 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 239 | Water Supply Works |
| 240 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. |
| 241 | 15mm nominal bore |
| 242 | 20mm nominal bore |
| 243 | 25mm nominal bore |
| 244 | 32 mm nominal bore |
| 245 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work |
| 246 | 25mm nominal bore |
| 247 | 32 mm nominal bore |
| 248 | 40mm nominal bore |
| 249 | 50mm nominal bore |
| 250 | 65 mm nominal bore |
| 251 | External Plumbing Works |
| 252 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 150 mm dia. R.C.C. pipe: |
| 253 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :For pipes 100 to 250 mm diameter |
| 254 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :For pipes 100 to 250 mm diameter |
| 255 | 02 GAIL Ashiyana - Item rate |
| 256 | Renovation & Developmental Works at GAIL Ashiyana |
| 257 | SMART LOCKS |
| 258 | Supply & Installation of MyGate Lock Plus Black on Existing Doors of Townships, Guests House Rooms at GAIL Alaya and GAIL Ashiyana |
| 259 | EPABX System |
| 260 | Supply Installation, Testing and Commissioning of IP Phone with minimum 2 Line display and minimum 08 Key of following makes Unify/Progility/Coral/Alcatel. The instrument shall be in line with technical specifications of IP Phones of the tender document. |
| 261 | Road safety |
| 262 | Supply & Fixing of Plastic Speed Breakers as per following specifications: Single Breaker Size: 250 mm x 400 mm x 50 mm Material : ABS Load capacity (Kg): 80000 KGFeatures: 25mm Water Crossing Drainage facilityReflector: 04nos. (Plastic Glass Reflector) in single block Thickness: 6-8 mm Force Endure Capacity: 35tonWorking Temperature: (-5 to 65 Degree)Locking: Hidden Interlocking |
| 263 | 04 GAIL Bhawan - C&I - Item rate |
| 264 | GAIL Bhawan - Civil & Interior |
| 265 | MARBLE & GRANITE WORKS |
| 266 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Base Rate of Stone: Rs. 500 per SqFtEquivalent Shades or as per approval by EIC FOR WHITE MARBLE - luxurious marble like Statuario Marble, Calacatta Borghini, Michelangelo Marble - FOR BLACK MARBLE - Nero Marquina Marble, Bhainslana Black Marble (Rajasthan), Zebra black marble |
| 267 | FLOORING WORK |
| 268 | Providing and laying Marble stone flooring in required design and patterns, in linear as well as curvilinear portions of the building including stone inlay works whereever required as per drawings and as per directives of EIC all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Base Rate of Stone: Rs. 500 per SqFtFOR WHITE MARBLE - luxurious marble like Statuario Marble, Calacatta Borghini, Michelangelo Marble or Equivalent as per approval by EIC FOR BLACK MARBLE - Nero Marquina Marble, Bhainslana Black Marble (Rajasthan), Zebra black marble or Equivalent as per approval by EIC |
| 269 | Providing & Fixing of Approved Carpet Tiles (multi-level loop construction, 100% PP fiber, pile height ~4mm, total thickness ~7.5-8.5 mm, pile weight ~800 gm/mยฒ, with felt or eco cushion backing): - Size 500mm x 500mm / 600mm x 600mm, laid on existing floor including surface preparation, use of approved adhesive, cutting to size, fixing skirting (if reqd.), cleaning, and all complete as per manufacturer's specifications and Engineer's direction. |
| 270 | Providing and laying Laminate wooden flooring (Grade AC6 or AC6+ laminates) 6 mm to 12 mm thick, having a good backing layer made up of plastic laminate or melamine, core made up of medium-density fibreboard (MDF),which is less resistant to impact damage and less resistant to being dented by heavy furniture, having a dรฉcor layer to give each floor its appearance and consisting of one or more sheets of paper impregnated with melamine resin and top wear layer having clear aluminium oxide finish that protects the decorative layer & imparts the desired level of sheen, from full gloss to low gloss, duly fixed to the base floor using adhesive as approved by the manufacturer. |
| 271 | Providing and fixing 1st quality Ceramic Subway Tiles (e.g., 3x12, 100x300mm) in approved color (White, Black,Blue etc.) for wall dado/backsplash. Rate includes 12mm-18mm cement mortar (1:3 or 1:4) bed, 4-5mm thick float of cement, and jointing with epoxy grout of matching shade. |
| 272 | ROOFING & FALSE CEILING WORKS |
| 273 | Wooden ceiling finish with Laminate :Providing and fixing IS 710 12 mm thick plywood false ceiling as per drawing & instruction of EIC & sample approved (complete with frame work). finish with 1.5 mm thick Laminate. Plywood shall be fixed with required fabrication work and ply frame work with all necessary acessories Rate shall include cost of making of all cutouts for light fixtures, gadgets, gizmo, pelmets, grooves, beads and also provide support/template where ever requiredThe rate shall be in sq.mt for all floors and at all heights including all costs the shop drawing (or a sample mock of 5 M2 minimum of the frame work and ceiling) shall be approved from EIC. 5mm Groove shall be provided at the junction of the false ceiling & the wall. ( considering all levels with require all fabricataion work and fitiing from RCC slab to false ceiling100 to 1000 mm) |
| 274 | Providing and fixing wooden linear batten/slat false ceiling suspended from the existing ceiling slab. The battens shall be [insert species, e.g., Teak/Steam Beech/Pine] wood, measuring [e.g., 25mm x 50mm], with a spacing of [e.g., 25mm] center-to-center, as per the architect's design. The battens shall be finished with [e.g., melamine polish/PU finish] in matte/glossy shades. The framework for the wooden batten ceiling shall consist of [e.g., 50mm x 50mm] kiln-seasoned, anti-termite treated hardwood sections, securely fixed to the slab using GI rods, dash fasteners, and anchor bolts at required intervals. The rate includes all labour, materials, scaffolding, painting of the ceiling base (above the battens) in black, and forming of necessary light pockets/grooves for HVAC diffusers as per the approved design. |
| 275 | Providing and fixing c of Euroceil or approved equivalent make of white colour comprising aluminium channels and PVC translucent membrane with PVC gripper, the stretch ceiling having back lighting with LED modules of OSRAM or approved equivalent make of mutiple strips with compatible drivers including supporting wooden box and frames, cutouts etc. all complete as per drawings, specifications and directions of EIC/ Architect. NOTE :- โข False ceiling design can be stepped / curved / architectural design etc however only plan / horizontal surface shall be measured for the purpose of payment. Ceiling shall be hung from the existing slab through hangerโs. Rate quoted in the tender shall be applicable for all floor levels/ all floor height including scaffolding, etc complete. The rate of falseceiling items also includes 6 mm ply backing for supporting light fixtures in the false ceiling. |
| 276 | Providing & making POP false ceiling with frame work made with GI grade 175 (120 g/sqmt.) channel fixed with steel expansion fasteners as per requirement of design indicated in the detailed drawing including providing and fixing galvanised expanded metal of sized 6 x 25 mesh (1.25mm thick) fixed with GI screws to and in between main runners. Applying POP (Calcium sulphate semi hydrate variety) to a thickness of not less than 10mm over the XPM finished smooth to line and level. The surface could be in the form of curves, edging or recesses etc. as may be specified or directed by architect including for 700 โ -75 mm circular cove light, cutout lights fittings, a/c grills diffusers/return air grills/trap doors etc.Rectifying all defects, and cracks formed during the construction period before handing over the work complete. The rates shall include for necessary supports, scaffolding, labour for completing the work in all respect. |
| 277 | Supplying, installing, testing, and commissioning of a 800 mm (diameter) x 50 mm (thickness) circular LED hanging profile light fitting, complete with all necessary hanging accessories, driver, wiring to nearest junction box, as per manufacturer's specifications and the satisfaction of the Engineer-in-Charge. |
| 278 | FINISHING WORK |
| 279 | Providing and applying Royale Luxury Emulsion of approved make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. wall primer with brush by adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dry for 6 to 8 hoursAfter applying acrylic wall putty with appropriate prpportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45% or 65 to 70 % by roller. Cost of putty to be paid separately in relevent item of SOR. Make: Asian/Oikos/Nerolac/Berger/Birla Opus |
| 280 | Providing and applying metallic/surface texture paint or equivalent acrlylic resin component based spray texture approved shade, to be applied on smooth surface i.e. POP or smooth plastered surface with 2 coats of white cement based putty, cost of putty shall be paid separately. The paint should be lead free and should have low VOC content-New work - two coats ( applied @1- 1.7 kg/sqm/coat) -any color/pattern/shadeMake: Asian/Oikos/Nerolac/Berger |
| 281 | DISMANTLING & MISC. WORKS |
| 282 | Dismantling of existing false ceiling manually or by mechanical means, including shifting of material within site for dumping area as approved by Engineer-in-charge, for all leads including all lifts involved. |
| 283 | Dismantling of above false ceiling services consisting of HVAC duct , diffusers etc., including their accessories etc. and cleaning the surface to receive new false ceiling as per approved design. Note: Measurement shall be as per existing false ceiling floor area. Note: Measurement shall be as per existing false ceiling floor area without any projections. |
| 284 | Dismantling of above false ceiling services consisting of fire sprinkler pipes including their accessories etc. and cleaning the surface to receive new false ceiling as per approved design. Note: Measurement shall be as per existing false ceiling floor area without any projections. |
| 285 | Dismantling of above false ceiling services consisting of electrical wiring and conduits LV cables including their accessories etc. and cleaning the surface to receive new false ceiling as per approved design. Note: Measurement shall be as per existing false ceiling floor area without any projections. |
| 286 | GLASS PARTITION & GLASS DOOR WORK |
| 287 | DGU Glass PartitionSupply, fabrication, and installation of DGU (Double Glazed Unit) glass panels (e.g., 6mm clear toughened + 12mm air spacer + 6mm clear/reflective toughened glass), including all aluminum framing sections (mullions, transoms), EPDM gaskets, structural sealant, pressure plates/cover caps, anchor fasteners, and necessary hardware, all as per architectural drawings and manufacturer specifications. Provision for gradient glass strip film application or use of pre-laminated gradient glass for specific panel areas, including design approval and installation. All related design, engineering, shop drawings, scaffolding, testing, cleaning, and protection of works until project handover. |
| 288 | DGU Glass DoorSupply and fixing of fully glazed or framed DGU glass door (e.g., 24mm thickness comprising 6mm+12mm+6mm toughened glass), including door frame (aluminum sections), hinges (floor spring/pivot), handles, locking arrangements, and all other specialized hardware (e.g., Dorma, Stanley equivalent). Application of gradient privacy film or use of factory-laminated gradient glass for door panels, with polished edges. Installation of door closer/springs, weather tight seals, and coordination with the surrounding curtain wall system. |
| 289 | Providing and fixing glazing doors using 12mm thk toughen clear glass (confirming to ASTM Standards C-1048) supported byc-channel (embedded in the floor) at the bottom & side edge and wall connecting profile at the top edge,stainless steel articulated countersunk bolts threaded bolts,chemical fasterners,etc., glass panel size as per design and drawing including applying colourless sealant of joint incl. required edge polish, making glazing water tight etc. Destructive node joint test reports to be submitted forestablishing the safety factor, including operating hardware, SS patch fittings, fabricated long length satin finish SS 304 handles,patchlock, floor springs etc., complete as directed by the architect for frameless patch doors,single or twin leaf shutters with fixed panel on top. (cost of door lock, floor spring and handle to be paid separately under relevant items) |
| 290 | Providing and supplying a pair of stainless steel pull door handle (D or H Type-as per approval of EIC) having minimum length of 600 mm and dia 32 mm for door shutter. SS 304 brush finish of approved make. |
| 291 | Providing and fixing Corner Patch Lock With Cylinder (Article code: 981.50.030) Hafele/Dorma/Godrej or eq. makes, SS Matt with necessary screws etc. complete as per direction of Engineer-in-Charge. |
| 292 | Providing and supplying double action hydraulic floor spring of approved brand and manufacture having brand logo embossed on the body / plate with double spring mechanism and door weight capacity of 150 Kg and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate. |
| 293 | Providing and fixing in position 12 mm thk Toughened Clear Glass in partition panels by using various glass fittings of approved make (DORMA / HAFELE / HETTICH) to be fixed with necessary fittings on the ceiling duly finished without giving any load on the false ceiling by using necessary hardware of Dorma / Hafele make what ever necessary and required numbers to complete the job in all respect. Rate including cost of door opening with approval hardware such as patch fitting lock, handle etc of approved make but without cost of floor spring. Contractor is advised to submit working drawing with details of approved make patch fitting, sizes of glass panels etc and take approvals of consultants before execution of works. All complete as per detail drawing, as specified and as directed by Architect / Consultant / Project - In - Charge. |
| 294 | Solid Partition with LaminateProviding and fixing partition framing shall consist of Heavy duty Aluminium Box Sections 75mm x 75mm @ 600mm c/c both ways Horizontally and Vertically. The vertical alternate frames to be fixed to the ceiling with necessary fixtures. The framing shall be finished with 8 mm thk. HDHMR board on both side and finished with 1.00 mm thk. Laminate / Vineer finished with melamine polish. The shade of laminate / vineer and polishing finish to be got approved from Engineer-in Charge / Architect. The skirting should be as per approved laminate as per drawing and direction. Rate shall be inclusive of necessary hardware items, etc. Complete. The edge beadings with steam beach wood should be finished with melamine. |
| 295 | Glass Partition With Wooden FrameProviding and fixing full height Glass partition of 86 mm thickness complete. Internal Sides 12mm Toughened glass Panel & outer side 12mm thick Frosted Acrylic sheet filling between glass wool conforming to IS : 8183, density 24kg / m3,laying in Wooden section frame of 86mm width and 36mm thick with the required divided partitions with support from true ceiling with wooden frame with maximum distance of 1200mm c/c Vertical ways and Top & Bottom Horizontal ways or as directed.The vertical alternate frames to be fixed to the ceiling with necessary fixtures. Rate shall be inclusive of necessary hardware items, etc. Complete. The edge beadings with steam beach wood should be finished with melamine. All related design, engineering, shop drawings, scaffolding, testing, cleaning, and protection of works until project handover. |
| 296 | Sliding Glass PartitionProviding and fixing in position at required location Sliding 10mm thick Toughened Glass Partition with Power coated Metal and Wooden Frame with Polishing , manual operation as per drawing etc as given in manufacturer's dwg. with track on wall with required accessories, track above the ceiling including overall installation, all necessary hardware etc. complete as per manufacturer's drawing & specifications with transportation, scaffolding ,all leads & lifts and as directed by Project Architect. |
| 297 | Providing and fixing Wooden doors of sizes as shown in the drawing. The door shutter shall of 35 mm thick flush shutter of approved make and finished with 1mm thick approved laminate on both sides. The edges finished with steam beach lipping. A door frame of 3.5โ x 2.6\\" steam beach section shall be provided finished in mellamine. Rate shall include Dead lock ( Godrej Make), floor springs / door closure ( as the case may be), door stopper, a pair of handles 12\\" SS Brushed finished, 5\\" hinges 4 Nos., buffers, tower bolts, etc with necessary hardware items. |
| 298 | MISCELLANEOUS ITEMS |
| 299 | Providing, fabricating, and fixing 18mm thick (nominal) MDF fluted decorative panel of approved brand, shade, design, and texture. The panels shall be fixed to a sub-frame or directly on to a continuous backing of 12mm thick commercial grade MDF board (exterior grade/BWP grade as specified). |
| 300 | Providing & fixing Full Height Both Side Laminated Partition at required location having height more than 3.55 meter & minimum 113mm thick made by using 75 x 75 mm (finished size) approved quality M.S section framing at 600 mm center to center, covered with 18 mm marine ply generally confirming to I.S.303 / I.S.710-1980 on both sides. The partitions shall be finished with 1.5 mm thk. approved quality laminate matt/suede/fine line finished lamination pattern with grooves on both sides with necessary lipping (BTC) moulding. Antitermite treatment to plywood and woodwork including all leads & lifts etc complete as per Architect's Drawing and instructions of Engineer In Charge. |
| 301 | Full /Low Height Storage (Laminate finish)-450 mm Deep: Providing and fixing full height storage cabinet formed of 18mm HDHMR Hard wood board formwork/carcass with adjustable shelves as per details.Shutter of storage cabinet to be formed of 19mm HDHMR Hard wood board finished with 1mm thick laminate of approved shade. All internal surfaces to be post laminated with 0.8mm thick HP laminate to approved shade. All external exposed surfaces to be finished with 1mm thick HP laminate to approved shade and all exposed edges to be finished with 2mm thick PVC edge band (factory finished) as per details. EA set of shutters to be provided with 1 no multi purpose lock as specified, 6mm thick SS D type handles, auto bolt as per details. Exposed wood surfaces to be finished with spray applied melamine polish (front area to be measured and paid for).Hardware: All hardware shall be as per the appoved model/make (Hettich/Hafele make) |
| 302 | Providing and fixing in position partly glazed 4'-0\\" HT. Partition work as per drawing ,in frame work at 2โx2โ grind (horizontally and vertically) comprising of 2โx1 ยฝโ hevy gazed almunium section and/or as per frame work shown in the drawings with 9 mm plywood ( confermin IS710 ) on both sides finished with 1 mm thick laminates of approved shade and colour as shown in drawings. Item to include 12 mm thick glass as per design and fitted with 3-1/4\\" thick beach wood beading at glass sides All exposed wood. surfaces to be finished in melamine polish of as directed including all necessary Stainless Steel finish fittings/hardware and wood preservative paint etc. as per list of approved material and as approved by the Project Consultant/Engineer-in charge complete in all respects. It also includeProviding , fitting & fixing Pine wood beading ( 75mmx18 mm or as per design ) in low height partition,cash counter front & low height cash counter front fasia with All pine wood beading surfaces to be finished in PU clear polish as directed . The work should be completed as per direction of architect including cost of all labour & material. |
| 303 | Manual Twist Blinds - Providing & fixing of Twist Window Shadings Blinds as per the sample shown having room darkening fabric strip and sheer fabric strips alternately in such arrangement as when light filering strips overlap each other, it creates visibilty and once the light filtering strips overlaps the sheer ones, it creates the no visibility effect.It has bottom rail made of aluminium alloy extruded profile, powder coated and provided in fabric coordinated colour. The rolling tube should be made up of aluminium alloy from extruded profile of ร34mm. The fabric of this Blind should be made up of 100% anti-static polyester vanes having light filtering and sheer vanes to reduce glare. Sheer layers made of white 100% knit polyester & the selection of colors, textures and opacities as per Engineer-in-charge. The FABRIC shall be constructed from spun-bonded 100% polyester fiber, having Green guard Certification treated with soil & dust repellant require minimum regular interval cleaning. The fabric has a maximum width of 2.80 M and a thickness of 0.38mm (+ 5%) and having weight of 272g/m2 (+ 5%).The strip size is Solid 8.5 cm / Sheer 6 cm. The shading to be operated by Easy rise mechanism with a continuous cord loop operating option. All plastic parts are in white color. Installation to be done by quick release brackets (wall or ceiling). |
| 304 | Providing and fixing skirting of 100mm height, made of 12mm thick BWR/BWP grade ply/MDF, finished with 1mm thick laminate of approved shade and make (e.g., Greenlam, Royal Touch), including necessary adhesive, stainless steel screws, and finishing of edges. |
| 305 | Providing and fixing panelling on wall. Framing shall consist of Heavy duty Aluminium Box Sections 50mm x 25 mm @ 600mm c/c Both ways horizontally and vertically on the wall.This framing would be covered by 8mm thk. comm. Ply finished in approved 1.0 mm. Thk. Laminate / Vineer finished in melamine polish. Wooden moulding, lipping etc. as directed by Engineer-in Charge / architect shall be provided wherever required. |
| 306 | Supplying and fixing of Reception table at the entrance of office of size 2750 X 1050mm , with main table of size2700X1050 mm, working space 2100 X 650mm .The Worktops shall be made of superior quality18 mm thick commercial ply confirming to IS: 12823 of approved shade. The top and side panels will be claded with special post forming laminated of thickness 0.62X0.8mm,Modesty panel shall be all around made of 18mm thick laminated commercial ply, confirming to IS: 12823 of length as per design. one wire managers shall be provided on table top with 55-60mm dia to hold wires. The side shall be provided with 2 nos. glide screws each. All exposed edges of table shall have 2mm thick Hot melt PVC banding. Complete in all respect including Glass top design fixed on glass fitting. |
| 307 | Wooden Panelling. PLY WALL PANELING FINISH WITH VENEER FINISH : Providing & fixing 12mm thick IS 710 ply fixed on frame work. The framework shall be fixed as per drawing vertically & @ 600 mm c/c vertical & 1200 mm c/c horizontally. The frame work shall be made from Aluminium section make JINDAL/HINDALCO conforming to IS specification In paneling, (intermediate, perimeter ) & (at vertical or horizontal joint of ply & at turning point ) shall be fixed to the wall/floor & ceiling with Sheet metal screws/Nylon grip screws of Corro-shield /Fischer and shall be supported by filling required size wedges /washers/ MS wall connectors or packings of teak wood /MS washers to ensure right angles and plumb level. All ply/wooden frameworks shall be treated with anti-termite treatment & hidden The framework shall be covered with approved make plywood(IS 710- 12 mm ply),adhesive ,tape, headless nails etc ,finished with 1.5mm thick Laminated Finish. PU polish & in pattern as shown in the drawing. Rate shall be inclusiveg grooves etc complete as per drawing or as directed by EIC/ Architect. The rate shall be in Sq.mt of actual paneling work for all floors, at all heights, all shapes .Rate shall inclusive of all material ,labor scaffolding, tools, tackles, for all heights and for all levels, Rates shall also be inclusive of cost of making cut outs/ openings for electrical fixtures, tube lights /air-conditioners ,grills, diffusers etc & providing additional sections for strengthening around the openings/cutouts, making grooves between wall & board or as per drawing /instruction of EIC. and no extra payment shall be considered for additional sections provided. All curved surfaces, recesses, waffles shall be part of the paneling including openable shutter wherever required area and finish with the same material. Rate shall be inclusive of all item inclusive part of paneling Only the clear elevation area shall be measured and paid. |
| 308 | Frosted sparkling glass film : Providing and fixing 3M Scotchcal Frosted Crystal or equivalent approved Translucent, cast PVC, self-adhesive vinyl, special CRYSTAL-effect film to reproduce Sand-blasting effect on glass with customised designs. MCS warranty of 3 (if exposed to direct sunlight) to 10yrs (indoors) must be endorsed by manufacturer. Rate shall be inclusive plotter cutting design as per architect suggestion. Contractor shall provide shop drawing for approval of Architect.work complete incuding all type of tools, tackles, scaffolding etc complete as per suggestion of Architect/ EIC. If in case any application finishing will not as per satisfaction contractor shall remove all film at their cost. Contractor shall do a sample mock of 5 M2 minimum of glass film) ,shall be approved from EIC.( At all floor) |
| 309 | PanelingSupply & installation of wall panelling made of pinewood E1 grade fiberboard, melamine/veneer laminated finish, groove perforated L32-2 - (2mm grooves @ 32mm centers), backlined with Sound texblack acoustical fleece, tongue-groove edge for a seamless look, 5-test fire retardant grade/ Non FR, Acoustics NRC 0.65- 0.75 (For E300* Mounting), size 128x2440x16mm, volume density of base board 800 - 830 Kg/m3, 10-10.5Kgs/m2 (L32), installed by using Strut framework system. Slats to be backed with Synthethik PF 10x25 adhered to wall with stick .The Panneling shall be finished as per the drawings and to the satisfaction of the Engineer in Charge. All the support system shall be as per the Approved make list and the suspension system shall be got approved before starting installation at site. |
| 310 | supply & installation description for glass railings details material specs (like SS 304 grade, 10mm thick toughened/laminated glass), fitting methods (top/side-mounted, spigot, channel), height (typically 1100mm for external), hardware (SS base plates, mechanical anchors), and scope of work (prep, leveling, securing, finishing), often found in PDFs from suppliers or project tender documents for clarity on quality, safety, and installation standards. |
| 311 | Supplying and fixing in position custom-fabricated bronze Cladding (brushed/aged finish, 1.5mm - 3mm thickness) fixing aluminium/MS bracket framework, SS screws, nut bolts, and anchors for secure installation. Filling joints with high-grade, non-staining, UV-resistant silicon sealant necessary scaffolding and safety measures for installation at height as per design drawings. |
| 312 | Ply palmet work : Providing and fixing wooden pelmets of upto 150mm/200 mm x 150 to 300 mm L shape made of 19mm thick ply as per IS 710 and beading of 4mm thick and 25mm wide Ghana Teak wood for curtains/blinds/projection screen of openings. Rate to be inclusive of lipping, cutting, wastages, necessary fixtures, nails, adhesives, necessary scaffolding, fixing at all heights and for all floors as per drawing and approved sample etc finish with 1.5mm thick Laminate finsh basic rate of Laminate 50/-per sqft(Mode of Measurements: Only the palmet length shall be measured & paid for the items in which palmet work is not inclusive in item description)( At all floor) |
| 313 | Providing and installation of acoustical wall panelling wood finish Slats made out of MDF board , Melamine / veneer laminated finish, perforated wooden grooved slats (2mm grooves @ 8mm centers) / (2mm Slats @16mm pitch) / (2mm grooves @ 32mm centers) / (2mm grooves @ 64mm centers), backlined with black acoustical fleece, tongue-groove edge for a seamless look, FR grade, of lineal dimension size 128mm x 2440mm x 16mm thick having density 1000Kg /m3, weight 12.8Kgs/m2 installed by using GI strut system. The GI strut system includes GI Cross channel having thickness 0.45mm, length 3600mm, knurled web 40mm, depth 10mm and equal flanges 15mm is fastened vertically/horizontally at every 600mm centers. Aluminium core cross channel having thickness 0.5mm, length 2400mm, web 15mm and 27mm, depth 18mm and flanges of 7mm with suitable edge and centre brackets is then fixed perpendicular to the cross channel with the help of fasteners at every 400mm centers. Contractor to Provide expansion joints of 3mm at every 5mts both ways. Make. Armstrong / Gyptek / Calsi. |
| 314 | Buffet Counter with storage:Providing and fixing of counter with storage cabinet formed of 18mm HDHMR Hard wood board formwork/carcass/adjustable shelves/shutters with all exposed edges finished with 2mm thick PVC edge band (factory finished) Counter Fascia Finish in Wooden Batten and Niche finish in approved Granite as per details shown in drawing . Top of cabinet to be formed of 19mm thick HDHMR Hard wood board. The storage also to have drawer pedestals made of 18mm HDHMR Hard wood board with all exposed edges finished with 2mm thick PVC edge band (factory finished) as shown in drawing. Top of cabinet to be formed of 19mm thick HDHMR Hard wood board. Rear backing of cabinet to be formed with 12mm thick HDHMR Hard wood board. Counter top, facia and 200mm high partial splash board to be finished with Prepolished Granite Stone of approved shade & make as per details. All laminate shades to be of approved shade and colour. Cabinet to have concealed dustbin behind flap door formed of stainless steel in hairline finish as approved.All exposed wood surfaces to be finished with spray applied melamine polish. Also to provide skirting in laminate finish as per details. (Front area upto counter top to be measured and paid for). Storage to be complete with hardware installed as directed to consist of the following: Shutter to have 2 nos of automatic spring loaded hinge of approved make installed strictly a per manufacturers guidelines with requisite tools/jigs. EA set of shutters to be provided with 1no. multi purpose lock as specified, SS handles, auto bolt, etc.Hardware: The storage to have all necessary hardware/ Locks/ Handles/ Hinges complete as per details drawing & shall be as per the approved model/make. |
| 315 | EXTERNAL DEVELOPMENT WORKS |
| 316 | Supply & Fixing of Plastic Speed Breakers as per following specifications: Single Breaker Size: 250 mm x 400 mm x 50 mm Material : ABS Load capacity (Kg): 80000 KGFeatures: 25mm Water Crossing Drainage facilityReflector: 04nos. (Plastic Glass Reflector) in single block Thickness: 6-8 mm Force Endure Capacity: 35tonWorking Temperature: (-5 to 65 Degree)Locking: Hidden Interlocking |
| 317 | 06 GAIL Bhawan - Electrical -Item rate |
| 318 | Cabling & Wiring |
| 319 | Supply, installation, testing & commissioning of RG-11 coaxial in conduits for TV System. |
| 320 | Supplying & installation of Co-Axial TV outlet with grid plate in GI/MS box including cutting, chases, fixing of GI boxes, cover plate & socket. |
| 321 | Supply, Installation, Testing and commissioning of floor Mounted GI Raceways of below mentioned sizes.Including all bends, Joints, Cover Sheet, End Caps, External Angles, Internal Angles, Flat Angles, Flat Junctions, Flat Tee, Flat Cross, Clips, Separation Partition etc. etc. and all other accesories required during installation shall be in scope of contractor. Contractor to quoate as per Drawing and site no additional items of accesories shall be paid extra. Approved Make- |
| 322 | 100mmX40mm Single compartment |
| 323 | 150mmX40mm Single compartment |
| 324 | Supply, Installation, Testing and commissioning of below mentioned Floor Junction Box made up of GI with 1.6MM sheet gauge |
| 325 | Floor Full Back Box( 150 x 150mm) |
| 326 | Floor Full Back Box(200 x 200mm) |
| 327 | Preparation of trenches upto 20\\" wide by carefully cutting floor removing the tiles & malwa below the tiles for laying Raceways/conduits for power, Data, voice etc. The depth of the trenches shall be atleast 60mm from the finished floor level or upto RCC of the slab. The rate shall include filling the trenches with rich mix of 1 : 2 PCC after laying of the Raceway/conduits for smooth finish upto original tile level. The rate shall not include the cost of the Raceways/conduits. |
| 328 | LIGHTING FIXTURES Storing, Handling & Installation, testing and commissioning of wall/ceiling, surface/recessed, suspended from down rods, flourescent/incandescent/halogen lamp lighting fixtures including lamp, power factor improvement capacitor ballast, control gear etc. including making connections with 1.5/2.5 Sq.mm PVC insulated copper conductor wire complete as required. |
| 329 | 15W LED Recessed Round Downlighter with a nominal system lumen output of 1200 lumens. The luminaire shall have a rated system lifetime of 40,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI>70. The luminaire shall meet IP20 rating with THD<10% and PF > 0.9. |
| 330 | 7W LED Recessed Round Downlighter with a nominal system lumen output of 900 lumens. The luminaire shall have a rated system lifetime of 40,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI>70. The luminaire shall meet IP20 rating with THD<10% and PF > 0.9. |
| 331 | 3W COB Recessed Mounted Ztiltable Wall Washer 3000 Deg. LED Spot Lighter |
| 332 | 3W COB Recessed Mounted fixed pin beam 3000 Deg. LED Spot Lighter |
| 333 | 1W COB Recessed Mounted fixed pin beam 3000 Deg. LED Spot Lighter |
| 334 | 15W LED Recessed Round Downlighter with a nominal system lumen output of 1200 lumens. The luminaire shall have a rated system lifetime of 40,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI>70. The luminaire shall meet IP20 rating with THD<10% and PF > 0.9.( With Dimmable Driver ). |
| 335 | SITC of LED Strip lights above ceiling compatible with Dimmibale Ballast to contril ambient lighting. |
| 336 | SICT of Dimmable ballst for LED Strips of 10Amp. |
| 337 | POPUP Box.SITC of POPup box with 2 Data, 2 Socket, 1 Switch, 1 HDMI for Conference Tables of Innofit or Equivalent make as per LOM |
| 338 | LT EARTHING |
| 339 | Supply & laying of hot dipped GI/pure copper earthing strip to connect to the DBS,Poles and equipments in outdoor yard and also in indoor portion of substation. |
| 340 | 35*6mm GI strip |
| 341 | 25*3 mm CU strip |
| 342 | 16 Sqmm Copper Flexible Single Core Green Color Earthinhg Wire |
| 343 | 6 Sqmm Copper Flexible Single Core Green Color Earthinhg Wire |
| 344 | Lighting Management System |
| 345 | SITC of Power supply unit shall generate safe extra low voltage (SELV) of DC 30V for one line with up to 64 LCS devices. The input power supply shall be rated at 220V AC frequency 50 Hz. DIMENSION: 4 Module (Model no : MTN684064) |
| 346 | SITC of 8 Channel Multi load 16A MAIN Relay Acutator For independent control of up to 4 blind/roller shutter drives or for switching up to 8 loads via make contacts. The function of the blind or switching channels is freely configurable. All blind/switch outputs can be operated manually using push-buttons. Similar to Schneider make MTN6705-0008. DIMENSION: 4 |
| 347 | SITC of 8 Channel Multi Load 16A EXTENSION Relay Acutator that extends the channels of a SpaceLogic KNX Switch/Blind MAIN to control of up to 4 blind/roller shutter drives or for switching up to 8 loads via make contacts. The function of the blind or switching channels is freely configurable. Similar to Schneider make MTN6805-0008. DIMENSION: 4 Module |
| 348 | SITC of 2 Channel DALI-2 Gateway to interface between DALI and KNX installations. Control and status feedback is carried out via KNX per DALI (2 x 64), with lighting groups (2x16), Individual control. Extensive fault and error messages are available and capable to control DALI DT8 lamp color control with different formats like color temperature (Kelvin), RGB or RGBW color, and HSV (Hue, Saturation, Value). Compact in size, shall be complied with IEC 61547 Standards. Similar to Schneider make MTN6725-0004. DIMENSION: 4 Module |
| 349 | SITC of networkable Multi Sensor with the coverage area shall be 7mtr diameter with mounting height of 3 meters. The presence detection / Movement detection sensor shall send commands in KNX bus to switch on or switch off the lights based on the occupancy. If sufficient day light and natural light brightness is available inside the room, the sensor shall have an intelligence to keep the lights in off condition though it detects the movement / presence in the room. The Sensor shall have an option to receive the IR codes. Similar to Schneider make MTN630919 |
| 350 | SITC of Push buttons shall be available with 8 operating buttons, operating and status display and labelling field. Each button shall be capable of being programmed to achieve various control functions including, setting a scene, toggling, switching, dimmer control and blind control. Similar to Schneider make MTN627819 / MTN627860 |
| 351 | SITC of Enclosures to mount Actuators, DALI Gateways, IP Routers and Spacelynk module. Similar to Schneider make A9HFD456 |
| 352 | SITC of 2 core 1.5 Sqmm Cu. Flexi cable for DALI Communication. |
| 353 | SITC of BUS-EIB J-H (St) Hv 2x2x0,8mm cable to connect all sensors, Pushbuttons, Actuators and DALI Gateways - (Cancab) |
| 354 | LOW VOLTAGE WORKS |
| 355 | Supply and drawing of UTP 4 pair 23 AWG CAT 6A LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required conforming to the following standards like ANSI/TIA 568 C.2, IEC 60332-1, IEC 60754-1. Cable Dia 8.0 mm with beneding radius -4 X Cable Diameter Operates at frequency of 500 Mhz . |
| 356 | Supply, Installation, testing and commissioning of Cat6A Tool less Information outlet for Data & Voice. Cat6A U/UTP built in crimping mechanism with capability of retermination without refreshing the wires. LCS2 Toolless RJ45 Information outlet with insertion cycle (in & out) should be 2500 times (I/O) along with front side Label holder and transparent shutter. The Information Outlet connector shall be of gold/nickel, thickness of gold > 0.8 ฮผm.The connectors shall be compatible as per IEEE 802.3af standard for POE application. |
| 357 | Supply, Installation, testing and commissioning of CAT6A UTP 24 AWG Patch Cord - 1 mtr with cross separator , Manufactured from stranded wires for longer flex-life , Minimum length of 1m, and maximum length of 5m Conforming to the following standards like EN 50173, ISO/IEC 60603-7 & 11801/IEC 60332-1, UL VW-1 |
| 358 | SITC of Double port Face Plate : Polycarbonate Hi-Grade Plastic FR Grade & UV Resistant 850 degree C/ Glow Wire Test. The face plate should be compatible for Cat5e, Cat6 range of RJ45 and AV connectors.The face plate Size should be of minimum 86x86mm. |
| 359 | Supplying & Fixing of Fiber Optic SC style fully loaded Patch Panel (FOPP), 19\\" Rack Mount ,Shall have all accessories including coupler plates pre loaded with 24 Nos of LC couplers (OM3) with all accessories complete in all respect. Pigtails Should Complie to ITU-G657.B-Bend insestive fiber.. |
| 360 | EPABX System |
| 361 | Supply Installation, Testing and Commissioning of IP Phone with minimum 2 Line display and minimum 08 Key of following makes Unify/Progility/Coral/Alcatel. The instrument shall be in line with technical specifications of IP Phones of the tender document. |
| 362 | 08 GAIL Alaya - C&I - Item rate |
| 363 | CIVIL & INTERIOR WORKS SOR |
| 364 | Flooring Works |
| 365 | Providing and laying machine cut, mirror polished Marble stone flooring, in required design (Simple geometrical, abstract etc.) and in patterns in combination with Italian marble stones of different colours, shades and finished surface texture etc., in linear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm, including pointing with white cement slurry admixed with pigment to match the marble shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.18 mm thick Italian Marble stone slab of any color shade and pattern as approved by EIC Base Rate of Italian Marble: Rs. 500/- per SqFt |
| 366 | Extra for making grooves of any type as per instructions in italian marble/granite works along with polishing the groove and making the surface finished as per the directives of EIC. |
| 367 | Providing & Applying Crystalline Coating on Italian Marble & Granite for surface and polish life enhancement |
| 368 | Providing and laying at site 12-14 mm thick laminated Parkett OR APPROVED EQUIVALENT hardwood clock floor/skirting having an inbuilt 1 mm soundblock CS backing of use 33/23, having a wear resistance level of AC6 .Impact resistance -IC 3 as per EN 13329, with 0.3mm thick MLC (multi layer composite) high pressure laminate surface treated with aluminium oxide & a specially patented surface guard on top of a high density fibre board with a density of 910 kg/MT3 plant of size 1198 x 194mm having a chick system tongue and groove joint to secure a long lasting joint. The tongue and groove have their edges duly impregnated with porative confirming to EN 13329, ASTMC 1028, DIN 5218, DIN 59345, EN 7122, DIN 4102 all complete. Approved decor planks to be placed on underlay -0.2 mm the alkali resistant polyethelene sheet density 935 kgs/m3 to resist moisture movement from sub floor and secure floating floor installation.Makes: Junckers/ HKS/ Pergo/ Parkett |
| 369 | Acrylic Solid Surface Providing & Laying Corean/Acrylic Solid Surface 12 mm thick of approved shade, pattern and design, duly grinded and polished to provide a seamless, jointless and luxury finish wherever required as per drawings or directives of EIC on horizontal & vertical surfaces with an underlay of 12mm thick plyboard of approved make, making the surface even and finished to the satisfaction of EIC/Architect. |
| 370 | Ceiling Works |
| 371 | P&F Access opening trap doors /access panel clad in 1/2\\" thickness consisting of concealed mechanical touch-latch in ceiling placed inside Aluminum channel frame work which is fixed to ceiling framing on all sides and hanged from RCC slabs with GI flats/wires which are fixed with dash fastners. It shall be moisture mold resistant GWB inlay. The system shall be complete with lift outdoors and safety cables. The perimeter shall be provided with rubber gasket to make it air and smoke tight complete as per design & drawing & instructions of Architects. The rate shall include working at all heights and nothing extra shall be payable on account of scaffolding. |
| 372 | Providing and fixing wooden framework-100 mm X100mm Size or otherwise suggested of approved size and shape on the Ceiling. The framework so prepared shall be finished with 4mm thick veneer on top of 12mm thick ply and as per cutouts and designs if any as per detailed drawings. Provisions shall be made to mount LED Light strips or any other light as per design behind the Sheet for illumination. This ceiling shall be securely fastened to the true ceiling with proper fixing arrangements as structurally suitable as approved by the consultant. The visible sides of the wooden surfaces/veneers shall be duly PU polished in approved colour of high gloss all complete as per directions of EIC. The light shall be paid extra. Nothing shall be payable on account of fixing of light/making cutouts/holes etc.All the wooden members shall be as per CPWD Specifications and all necessary specifications shall be strictly adhered to. The contractor shall ensure that all wooden members used in the framework shall be properly seasoned before making use of it. The rate shall include working at all heights and nothing extra shall be payable on account of scaffolding. |
| 373 | Providing & fixing of PVC plank light weight material False ceiling of 02 Groove series (2G) of thickness morethan 9 mm and width 1' (feet) in Toilet blocks in teak wood finish as per approved design & colour. PVC false ceiling should be Fire Retardant with a classification according to SANS 428 of Class B/B1/2. The rate should include all accessories, fixtures, \\"L\\" corner, \\"H\\" corner,\\"U\\" corner, beading, S.S screw, scaffolding, cleaning etc. complete. Contractor will submit the technical data sheet, samples etc. before execution. |
| 374 | Providing & fixing horizontal level suspended ceiling comprising of Vertical Linear Baffle Ceiling made out of Aluminum Extrusion in Aluminum alloy grade 6063 T5. The baffle blade shall be in size of 150x50x3600mm or as specified in powder coated to Plain finish (Black / White/Woodgrain as per approval). The baffle shall be electrostatically polyester powder coated to a coating thickness of 60-80 micron. The shade variation within a manufacturing batch shall be delta E<1 using Excite/BYK Gardner instrument and gloss level 25ยฑ5% at 60ห as per ASTM D523 (Not applicable of Wood Grain Shade). The baffle blade shall be suspended using Slotted U-profile of 20 x 30 x 3700mm (Thk-1.5mm) having slots in module of 25mm to keep baffles at an on-center spacing in multiples of 25mm. Longer lengths of Baffle to be connected by Baffle Joiner and the ends to be fixed with End caps. The baffles Shall be hanged using baffle hanger from U-profile made of mild steel with powder coating thickness of 60-80 micron. The U โ profile to comprise of alternate square & rectangular slots of 6.5x6.5mm & 28x6.5mm respectively on the web for locking the baffle hanger using plugin clip to secure the hanger in perfect position and achieve uniform spacing between baffles. The overall dimension of the U โ profile is 20(W) x 30(H) x 3750(L) mm and is rolled form from 1.5mm thick mild steel with a powder coating thickness of 60-80micron. U- Profile to be connected to each other using U โProfile Splice. |
| 375 | The U- profile shall be hanged from the true ceiling using threaded rod using a U- Profile hanger. The U profile to be suspended at every 1200mm center to center using 6mm threaded rod from the structural soffit using U-profile hanger. U-profile splice to be used to join more than one U profiles of length 3.7M. 1st U-Grid Channel must be no more than 400mm from the perimeter. Locate the slot for Baffle Hangers in U Profile section at 1200mm centers. Hangers are inserted into the slot, then rotated 90ยฐ and fixed into position by tightening the grub screw. Baffle to be lifted into position and hangers engage over lip of U-Grid Channel. Each Hanger to be secured into position by inserting the Locking Clip. When doing continuous installation, Baffles blades are to be connected at ends with Baffle Joiner, which are inserted into the top and bottom slots of the Baffle closed profile for alignment only. The bottom Joiner to be located first and fastened on one side only. The top Joiner to be fitted then and secured with grub screws on one side. Then the two Baffle sections shall be joined and the top Joiner is screw fastened on the 2nd Baffle profile. |
| 376 | Wood Work |
| 377 | Customized Beds - Top Elevation to be Measured Making at site or facory manufactured queen size bed (81 inch x 63 inch x 42 inch, box bed of 15 inch height, total height with head board of 42 inch) made out of 18 mm thick commerical plywood with veneer finish on outer surface and laminated finish on inner surface. Plywood board of 12 mm on top. The bed shall have 2 drawers each on both sides for storage purpose of approx 36 inch width, 10 inch height and 24 inch depth. The corners and sides to be finished with teak wood moulding of 2 inch width and shall be of rounded type. Head Board: Size of total 42 inches height and 63 mm width of 2-3 inches thickness with wooden stypes of 4 inches in C Shape duly veneered and polished in matching pigment as bed box. The head board upholstry to be of leather with 40 density form as per approved pattern and shade as approved by EIC. The bed to be made in line with the reference image. For measurement purpose top elevation to be measured. (Contractor to submit shop drawings for approval before start of execution at site) |
| 378 | Customized Side Tables - Front Elevation to be Measured Making at site or facory manufactured bed side tables (apporx. size 18 inch width x 18 inch depth x 16 inch height, actual size may differ slightly as per site requirement, made out of 18 mm thick commerical plywood with veneer finish on outer surface and laminated finish on inner surface. The table shall have 3 drawers for storage purpose. The top corners shall be finished with teak wood moulding of 18-19 mm width and shall be of champered edge type. The top drawer to be used for notepad, pen, mobile phone storage, the other two drawers to be used for basic material storage of the guest. Telescopic channels to be used for drawers and SS drawer handles of 4 inch width to be used for push pull arrangement of drawers (Contractor to submit shop drawings for approval before start of execution at site) |
| 379 | Partition Work - Providing and fixing in position opaque partition consisting of frame work in extruded aluminium sections 1.6 mm thick, of approx size 50 x50 mm , placed at center to center at not more than 600 mm vertically and 600 mm horizontally, joined using angle 35x35x 3 mm . Securely fixed to wall and , floor and ceiling complete in all respect . The rates shall be inclusive of cutting , punching of holes for drawings conduits and boxes for electrical works etc. Providing and fixing to aluminium frame work , Particle/ MDF / Ply Boards/Gypsum Boards etc., fixed with fully threaded parallel shank screws at 200 to 300 mm centre to centre , on both sides of framework. Joints staggered on either sides of the partitions to avoid through joints complete as per directions of Engineer-in-Charge. (Ply Board/Gypsum/MDF/Particle Board work to be measured and paid separately). |
| 380 | Panelling Work - Providing and fixing in position opaque panelling consisting of frame work in extruded aluminium sections 1.6 mm thick, of approx size 50 x25 mm , placed at center to center at not more than 600 mm vertically and 600 mm horizontally, joined using angle 35x35x 3 mm . Securely fixed to wall and , floor and ceiling complete in all respect . The rates shall be inclusive of cutting , punching of holes for drawings conduits and boxes for electrical works etc. Providing and fixing to aluminium frame work , Particle/ MDF / Ply Boards/ Gypsum Boards etc., fixed with fully threaded parallel shank screws at 200 to 300 mm centre to centre , on both sides of framework. Joints staggered on either sides of the partitions to avoid through joints complete as per directions of Engineer-in-Charge. (Ply Board/Gypsum/MDF/Particle Board work to be measured and paid separately). |
| 381 | Providing and fixing Single layer of 12mm thick BWP Ply as per details on single side of the existing aluminium partitions framework or elsewhere as required as per drawing details/site requirement including taping jointing and groove etc complete and shall be provided as per the direction of EIC. |
| 382 | Providing & Fixing 12mm thick commercial plywood on single side of the existing aluminium partitions framework or elsewhere as required as per drawing details/site requirement including taping jointing and groove etc complete and shall be provided as per the direction of EIC. |
| 383 | Providing & Fixing 18mm thick commercial plywood on single side of the existing aluminium partitions framework or elsewhere as required as per drawing details/site requirement including taping jointing and groove etc complete and shall be provided as per the direction of EIC. |
| 384 | Providing and fixing - Panelling with 12.5 mm thick Gypsum double skin fire rated board including taping and jointing complete. |
| 385 | Providing and fixing infill of 50mm thick & min. 60 kg / m3 density Mineral Wool Insulation. Mineral wool packed in polyweave packets inside partition frame work fixed to wall with Clip, screw, rawel plug & washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-in-Charge. |
| 386 | VENEER PANELING Providing and fixing of 3.5-4 mm thick Ply Veneer cladding of Maple or approved shade on existing partitions/ panelling fixed with adhesive, matching grains and including spray applied matte melamine polishing, primer, groove etc. complete. Veneer to be fixed in panels of width as specified and 4mm grooves as per drawing including taping jointing and groove etc complete. Minimum Basic price of Veneer @ Rs.1000/ Sqmt + taxes |
| 387 | GLOSSY/ MATT LAMINATE 1 mm thick - Supply and installation of approved shade Glossy/ Matt Laminated sheets of desired colour and shade including taping jointing and groove and glue/ adhesive to applied on laminate and ply etc. complete. Minimum Basic price of Laminate @ Rs.1700/ per sheet of 8'x4' + GST i.e. Rs. 580 per sqm |
| 388 | Supplying and providing Duco Paint on new work two or more coats including preparing surface and primer etc. complete |
| 389 | Providing and fixing - 4/6 mm thick charcoal board panel including taping jointing and groove etc complete |
| 390 | Providing and fixing - 6 mm thick commercial ply including taping jointing and groove etc complete |
| 391 | Providing & Fixing Keyless Cylindrical Lock Stainless Steel Finish (bathroom lock without key) of approved make: Godrej/Dorma/Ozone/Hettich/Hefele/Dorset |
| 392 | Providing & Fixing Cylindrical Lock Premium Range for Bedroom Doors, for Home & Office, Left/Right Handed & Inside/Outside Opening (60mm) Backset in Stain Steel Finish with 3 Keys and 5 Year OEM Warranty. Approved make: Godrej/Dorma/Ozone/Hettich/Hefele/Dorset |
| 393 | Providing and fixing glazing doors using 12mm thk toughen clear glass (confirming to ASTM Standards C-1048) supported byc-channel (embedded in the floor) at the bottom & side edge and wall connecting profile at the top edge,stainless steel articulated countersunk bolts threaded bolts,chemical fasterners,etc., glass panel size as per design and drawing including applying colourless sealant of joint incl. required edge polish, making glazing water tight etc. Destructive node joint test reports to be submitted forestablishing the safety factor, including operating hardware, SS patch fittings, fabricated long length satin finish SS 304 handles,patchlock, floor springs etc., complete as directed by the architect for frameless patch doors,single or twin leaf shutters with fixed panel on top. (cost of door lock, floor spring and handle to be paid separately under relevant items) |
| 394 | Providing and supplying double action hydraulic floor spring of approved brand and manufacture having brand logo embossed on the body / plate with double spring mechanism and door weight capacity of 150 Kg and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate. |
| 395 | Providing and supplying a pair of stainless steel pull door handle (D or H Type-as per approval of EIC) having minimum length of 600 mm and dia 32 mm for door shutter. SS 304 brush finish of approved make. |
| 396 | Providing & Fixing Stainless Steel Bottom Corner Patch Locks with Strike Plate for Glass Doors of thickness 10-12 mm. The lock shall have a dead bolt projection of approx. 15mm with SS 3.4 Cover secured with samll L key, lock to be supplied with 3 high security computer keys. (Makes: Ozone/Hettich/Hafele/Dorma/Dorset/Kich) |
| 397 | Providing and fixing in position of box type STORAGE CABINET unit made out of 18 mm thick termite-resitant, waterproof BWP commercial ply for bottom & top, shelf/ partition, sides, drawer units, shelves etc. and 12 mm WPC back sheet for backing. Front shutter made out of 18mm thick commercial board, all outer exposed area shall be finished with approved 4 mm decorative teak ply veneer and inside areas shall be finshed with 1 mm thick laminate as/approved. Anti termite oil to be put on the raw surface before applying/ finishing with laminate. Price to including necessary hardware such as knobs, handles, magnet catchers, lock, hinges, hanging rod oval shaped, telescopic channel for drawers. All exposed edges finished with PVC lipping (2mm) duly finished with matching colour and pattern as directed. Complete in all respect including grove, fixing with wall, getting it approved, constructing set (s) for mock-up sample for approval, modifying, etc.upto 450-600 mm deep as per site conditions, contractor to submit shop drawings to GAIL for approval before start of execution at site. The key elements to be included in the storage are as follows: 1. Shoe Rack at the botton 2. Two no. of drawers with locking arrangement3. Hanger Rod4. Brief Case Storage 5. Apparal Storage 6. Lighting Point inside the storage connected with opening magnet Shop Drawings to be made as per actual space availablity at site incorporating all key elements as mentioned above. Note: The front finished plan area of the cabinet shall be measured for payment purpose. All complete including melamine polishing of approved grains and shade of the outer veneer surface of the storage almirah. |
| 398 | Telescopic Channels Providing & Fixing Telescopic Drawer Channel Set, Left + Right, Ball Bearing RunnersTested for Durability: Rigorously tested with 50,000 open-close cycles to ensure long-lasting performance and reliability.Smooth Operation: The advanced telescopic ball bearing mechanism ensures effortless and soundless drawer movement, providing a premium user experience. Enjoy the quiet and seamless operation that makes accessing your drawers a breeze.Heavy-Duty Performance: Each pair of slides can support up to 45 kg, making them suitable for a variety of heavy-duty storage needs. |
| 399 | Painitng & Wall Dรฉcor |
| 400 | Finishing walls with textured paint (ruff & tuff) of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqmMake: Asian/Oikos/Nerolac/Berger/Birla Opus |
| 401 | Providing and applying Royale Luxury Emulsion of approved make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. wall primer with brush by adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dry for 6 to 8 hoursAfter applying acrylic wall putty with appropriate prpportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45% or 65 to 70 % by roller. Cost of putty to be paid separately in relevent item of SOR. Make: Asian/Oikos/Nerolac/Berger/Birla Opus |
| 402 | Providing & Installation on walls PVC Charcoal Rafter Panels of size 5\\"x8' and 12 mm thick, tongue edge groove seamlessly jointed along with a backing ply of 12 mm including the cost of cut outs and other required accessories. The shade, pattern etc. shall be decided by the EIC. Base Rate of Rafter Panel: Rs. 300/- per SqFt |
| 403 | Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part - 1 & II) 1976, applied on hacked / uneven background such as bare brick/ block/ RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete. |
| 404 | Providing & fixing 8mm thick lacquered glass fixed with compatible neutral core silicon/ double sided tape on a perfectly leveled 12mm thick water proof plywood which is mounted on the RCC wall/any other structure. Lacquered glass shall be annealed premium GRIHA rated of approved color by engineer-in-charge, must be made industrially (via curtain coating process); opaque (if viewed against a support wall), coated with PU lacquer (25 micron thick); color consistency (measured by Minolta spectrophotometer CM5081); highly durable (passes PERSOZ hardness test for minimum 220 oscillations); humid resistant (conforms to BS EN 1036 1999); environmentally friendly (no lead, no arsenic, no copper, no formaldehyde); appropriate recycled content (12% post industrial / 6% post consumer); compressive strength (1000 MPa) & tensile strength (40 MPa),same as float glass to all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 405 | Providing & Fixing Decorative Artefacts, Paintings, Murals, Logo etc. The selection of items to be done by Architect/GAIL. The same shall be paid based on the actual tax paid invoice including freight plus 10% to cover contractor's profit and overhead. |
| 406 | Providing and applying metallic/surface texture paint or equivalent acrlylic resin component based spray texture approved shade, to be applied on smooth surface i.e. POP or smooth plastered surface with 2 coats of white cement based putty, cost of putty shall be paid separately. The paint should be lead free and should have low VOC content-New work - two coats ( applied @1- 1.7 kg/sqm/coat) -any color/pattern/shadeMake: Asian/Oikos/Nerolac/Berger |
| 407 | Providing and fixing of approved shade of Wallpaper. Wallpaper to be sticked using Adhesives , including all necessary hardware required for it etc., complete as per the detail drawing. Minimum Basic price of Wallpaper @ Rs. 200 per sqft + GST |
| 408 | Provding & Fixing in Position SS Curatin Rod 25 mm dia - Brass Polished |
| 409 | Twin Rod Brass Polished Decorative Curtain Socket (Set of 2 Sockets) Suitable for 25 mm dia curtain rods with locking arrangement |
| 410 | Curtains Providing & Fixing Curtains combination of back curtain of sheer semi trasnparent for light trasmittance and front curtain of blackout/dimout feature on curtain channels. The curtains shall be of Spaces/Ddecor make of base price range Rs. 3000/- per set of Sheer/Dimout/Blackout curtains of dense fabric of premium quality. Length alernation of curtains to be in the scope of the contractor and nothing extra shall be paid on account of same. One set of curtain shall be of size approx. 9'x4', however brand size variation shall be allowed upto 6 inches. |
| 411 | Providing and Fixing in position premium branded M Track Double Curtain Channel set for a Window/Door of required length, Wall Fit/Ceiling Fit as required, All Accessories included - Runners, Hooks, End caps, Ceiling/Wall brackets, Jointers, Screws, Wallplugs, Curtain Hooks as required. The color of the channel to be decided by GAIL. All complete to the satisfaction of EIC. |
| 412 | Manual Twist Blinds - Providing & fixing of Twist Window Shadings Blinds as per the sample shown having room darkening fabric strip and sheer fabric strips alternately in such arrangement as when light filering strips overlap each other, it creates visibilty and once the light filtering strips overlaps the sheer ones, it creates the no visibility effect.It has bottom rail made of aluminium alloy extruded profile, powder coated and provided in fabric coordinated colour. The rolling tube should be made up of aluminium alloy from extruded profile of ร34mm. The fabric of this Blind should be made up of 100% anti-static polyester vanes having light filtering and sheer vanes to reduce glare. Sheer layers made of white 100% knit polyester & the selection of colors, textures and opacities as per Engineer-in-charge. The FABRIC shall be constructed from spun-bonded 100% polyester fiber, having Green guard Certification treated with soil & dust repellant require minimum regular interval cleaning. The fabric has a maximum width of 2.80 M and a thickness of 0.38mm (+ 5%) and having weight of 272g/m2 (+ 5%).The strip size is Solid 8.5 cm / Sheer 6 cm. The shading to be operated by Easy rise mechanism with a continuous cord loop operating option. All plastic parts are in white color. Installation to be done by quick release brackets (wall or ceiling). |
| 413 | Room Signages (Stainless Steel with single color/Multi color engravings) Providing and Fixing Room Signages for Office/ Reception/ Conference room/Cabin/Stationary/ Store room/Server / ups /electrical room/G.Toilet & Ladies Toilet with symbol/Pantry/Fire exist/rest room or for any other area as per the direction of EIC. The SS plate shall be 304 grade 2 mm thick glossy matt finish of approved shape as per drawing. single color/Multi color engraved signage Font and letter sizing shall be got aproved by the architect-sample shall be submitted. Rate shall include all hardware and necessary arrangement for fixing. |
| 414 | Providing and fixing stainless steel English (Capital) and Hindi letters in standard pattern bellow type made with 1.20 mm thick stainless steel (ASI Grade-304) Jindal or equivalent and rate includes welding/ soldering of joints polishing, buffing and fixing on the wall beam surface at any height with necessary nut and bolts/ fasterner wherever is required complete as per direction of Engineer-in-charge. (PER means Per letter per cm height here) |
| 415 | Supply & Installation of Acoustical Collapsible Wall Partition System Panel Specifications Position : Wall 1 & Wall 2 - ManualRun : 1 per wall Width : 3000 mm per wall Height : 2460 mm per wall Sound Insulation : 50 DB overallVE : 2 , & TE: 1Panel Thickness : 85 MMSuspension : 1-PTracks: RParking layout No: As per the drawingSurface : MDFThe item includes Sound Buffering Cost above partition track and in between suspended celling to stop sound leakage.The item also includes Partition Wall Tracks with Accessories & Panels installation including MS Fabrication work to fixTrack. All complete as per drawings, specifications and directions of EIC. This is in specialized item and to be executed through OEM as per list of makes. |
| 416 | External Works |
| 417 | Finishing Walls with Wall Painting System: Surface preparation of wallls plus Providing & Applying of One coat of Elastomeric Waterproofing membrane Top Base coat With 10 Years Waterproofing Warranty and Two coats of Premium Acrylic Exterior Emulsion.(Equivalent Products of Paints: Berger Weather Coat Long Life 10/Nerolac Top Guard/AsianUltima Protek)(Equivalent Product of Base Coat: Nerolac Perma No Damp Elastomeric Waterproofing Membrane/Ultima Protek Duralife/Berger PU RoofKoat)No other make of Painting System except the makes and products mentioned above shall be acceptable. Contractor may properly enquire the rate of painting plus wall waterproofing system with approved manufacturers before quoting the rate, further contractor shall also submit manufacturer's warranty certificate for waterproofing for 10 years. Warranty provided by the contractor shall not be acceptable. Contractor is also liable to arrange visits of manufacturer's team at site during execution for verification of works and products used in painting and also for work as per specifications. |
| 418 | Supply and application of additional layer for applying Asian paint Smart Care Tile primer or Eq as per list of makes without any dilution for better adhesion of smart care Damp Proof on tile surface. |
| 419 | Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/ masonry by suitable gun/pump at required pressure including Providing and inserting 12mm dia galvanised steel injection nipple in honey comb area and along crack line including drilling of holes of required diametre (20mm to 30mm) up to depth from 30mm to 80mm at required spacing and making the hole & crack dust free by blowing compressed air, sealing the distance between injection nipple with adhesive chemical of approved make and allow it to cure complete as per direction of Engineer-In-Charge and cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight of approved grout injected.) Epoxy injection grout in concrete/ RCC work of approved make |
| 420 | Providing & Laying Heavy Duty Vitrified Fully Matt and Fully Vitrified Parking Tiles of size 400x400 mm or 600x600 mm (Kajaria Duratec XT or Eq as per List of Makes) of approved pattern, shade and design, thickness to be specified by manufacturer. The item includes 20 mm thick cement mortar of mix 1:6 (1 Cement : 10 Sand) for fixing of tiles at desired surface. Base Rate of Tile: Rs. 120/- per SqFt. |
| 421 | Providing and fixing precoated galvanised iron profile sheet (size, shape and pitch of corrgated as approved by Engineer-in-charge) 0.50 mm thick (+/- 0.05%) and total coated thickness with zinc coating 120 grams per sqm as IS: 277, above 50mm thick corrogated Puff Panel in sandwich style puff between both side 0.50 mm thick PPGI colour RAL-9002 sheet with Puff density 40 kg+- 2/kg/sqm, with tounge & groove system. |
| 422 | PERMISSIONS AND LIASONING WORKS |
| 423 | If required, Getting approval for Building plan/ permission for Building Construction works from LOCAL municipal corporation/ development authority including liasoning, submission of drawings, inspection and clearance etc complete. Statutary fees to be paid if any shall be reimbursed by GAIL on submission of demand note and challan in proof of submission of fees. The scope of contractor shall be to get the Building plan/ permission from corporation. Lump sum rate is to be quoted for one complete activity unit/job (EA means 1 Job here) |
| 424 | If required, Getting approval for occupation certificate from LOCAL municipal corporation/ development authority including liasoning, submission of as built drawings, inspection and clearance etc complete. Statutary fees to be paid if any shall be reimbursed by GAIL on submission of demand note and challan in proof of submission of fees. The scope of contractor shall be to get the completion certificate from corporation. Lump sum rate is to be quoted for one complete activity unit/job (EA means 1 Job here) |
| 425 | If required, , FIRE APPROVAL - Following are the scope of work:- 1.Preparation of drawing & document. 2.Submission of drawing & document to the concerned authority / office with a copy of all correspondence to EIC. 3.Payment of drawing approval fees. (Shall be reimbursed on production of original challan) 4.Submission of work completion report as per approved drawing. 5.Arranging the inspection of the installation. The traveling, lodging, boarding and other expenses of statutory authorities for inspectons shall be born by the contractor. 6.Follow up at various level. 8. Completion of all fire related works such as fire-fighting works, PA/ Fire Alarm etc. all as per norms of the Building Approval Authority/ any other regulator as required and instructed by Engineer- In-Charge 10. Any other related job to obtain approval and running permission. Lump sum rate is to be quoted for one complete activity unit/job (EA means 1 Job here) |
| 426 | 09 GAIL Alaya - HVAC Works-Item rate |
| 427 | HVAC VRF/VRVWORKS BOQ |
| 428 | HIGH SIDE WORK |
| 429 | INDOOR UNITS OF VRF SYSTEM - CARRIER |
| 430 | INDOOR UNITS - CONCEALED FCU / DUCTABLE/ HIWALL / CASSETTE - CARRIER |
| 431 | Supply of indoor units having galvanized steel plate casing. The unit shall be insulated with sound absorbing thermal insulation material, Polystyrene/ Polyethylene foam. The unit shall be supplied with suitable decorative panel & resin net filter with Mold resistance. The unit shall be supplied with drain hose, clamp metal, washer fixing plate, sealing pads, screws, clamps, washer for hanging bracket & insulation for fitting flexible double canvas sleeve with necessary mounting arrangement, flanges, nuts and bolts etc.HI WALL UNIT UNITS (Including cordless remote controller) |
| 432 | 2.03 TR |
| 433 | 1.6 TR |
| 434 | Indoor Refnets |
| 435 | OUTDOOR UNITS OF VRF SYSTEMSupply of Compact Air Cooled type outdoor units of VRV system having hermetically sealed scroll type compressors 100% inverter compressor, condenser coil fabricated from Seamless Copper tube & Plate type Al. Fins of Multi Row, Axial Flow, upward throw condenser fan, Condenser fan - motor unit, insulated refrigeration piping, power / control wiring, and earthing, external wiring between Indoor & Outdoor units. Each Outdoor units with High Pressure switch, Fan driver overload protector, Over current relay, Inverter Overload Protector & Fusible Plug. The unit shall be suitable for 415 ยฑ 10 % volts, 50 Hz, 3 phase AC supply, and IP 65 protection.The cost of ELCB should be included. |
| 436 | CORDLESS REMOTE WITH VRF CENTRAL CONTROLLERCentral Controller for above entire VRF system ( indoor & oudoor). |
| 437 | LOW SIDE WORK |
| 438 | INDOOR UNITS OF VRF SYSTEMINDOOR UNITS - CONCEALED FCU / DUCTABLE/ HIWALL / CASSETTE Installation, Testing & Commission of indoor units having galvanized steel plate casing. The unit shall be insulated with sound absorbing thermal insulation material, Polystyrene/ Polyethylene foam. The unit shall be supplied with suitable decorative panel & resin net filter with Mold resistance. The unit shall be supplied with drain hose, clamp metal, washer fixing plate, sealing pads, screws, clamps, washer for hanging bracket & insulation for fitting flexible double canvas sleeve with necessary mounting arrangement, flanges, nuts and bolts etc.HI WALL UNIT UNITS (Including cordless remote controller) |
| 439 | 2.03 TR |
| 440 | 1.6 TR |
| 441 | OUTDOOR UNITS OF VRF SYSTEMInstallation,Testing & Commissioning of Compact Air Cooled type outdoor units of VRV system having hermetically sealed scroll type compressors 100% inverter compressor, condenser coil fabricated from Seamless Copper tube & Plate type Al. Fins of Multi Row, Axial Flow, upward throw condenser fan, Condenser fan - motor unit, insulated refrigeration piping, power / control wiring, and earthing, external wiring between Indoor & Outdoor units. ODU shall be with Anti Corrosive Coating.Each Outdoor units with High Pressure switch, Fan driver overload protector, Over current relay, Inverter Overload Protector & Fusible Plug. The unit shall be suitable for 415 ยฑ 10 % volts, 50 Hz, 3 phase AC supply, and IP 65 protection |
| 442 | CORDLESS REMOTE WITH VRF CENTRAL CONTROLLERITC of Central Controller for above entire VRF system ( indoor & oudoor). |
| 443 | BRANCH DISTRIBUTION JOINTS FOR REFRIGENT PIPINGSITC of Branch Distribution Joints for VRF system. |
| 444 | REFRIGERATION PIPING & FIRST CHARGE OF REFRIGERANT |
| 445 | REFRIGERATION PIPINGSupply, Installation, Testing & Commissioning of seamless Copper piping of adequate size duly insulated with 13 mm thk. Nitrile Rubber Insulation. Refrigeration piping will have to be taken in the piping rack / Support individually connecting to all indoor units for the respective floors. Even necessary supports, fittings, valves & ref. joints where ever required will be included. |
| 446 | First charge of Refrigerant R 410 for all circuits for entire system. |
| 447 | COMMUNICATION CABLING Communication / Control Cabling between Outdoor Units & Indoor Units, Communication cabling between the individual controllers to the main central controller with PVC conduits.2 Core x 1.5 Sq.mm sheilded |
| 448 | DRAIN PIPING FOR VRV INDOOR UNIT Providing and fixing in position the following pipes cut to required lengths and necessary fitting with 9 mm thk.Nitrile Rubber Insulation as per drawing. |
| 449 | 25 mm dia. UPVC pipe. |
| 450 | 32 mm dia. UPVC pipe. |
| 451 | 50 mm dia. UPVC pipe. |
| 452 | Electrical Cable |
| 453 | Power Cable for IDU (2.5sqmm 3 core flexible Cable). |
| 454 | Power Cable for ODU(16 sqmm 3 core Armoured Cable) |
| 455 | Lifting and Shifting of Material |
| 456 | MS Structure for ODU and Supporting of Unit If Required |
| 457 | Supply & Installation of Inverter Type Highwall Split Unit with Outdoor Compressor of following capacity: Note: Power Cables, Copper Piping as per requirement shall be paid extra as per relevant SOR items. |
| 458 | SUPPLY & INSTALLATION OF 1.5 TR - 3 STAR INVERTER SPLIT AC |
| 459 | SUPPLY & INSTALLATION OF 2.0 TR - 3 STAR INVERTER SPLIT AC |
| 460 | 11 GAIL Alaya - Plumbing-Item rate |
| 461 | GAIL ALAYA - PLUMBING WORKS BOQ |
| 462 | Sanitary Fittings & Fixtures |
| 463 | Providing and fixing Rimless, Blind Installation Wall HungWC With UF Soft Close Slim Seat Cover,Hinges And Accessories Set, Size: 375x520x400 mm. ( Ref Model: JAQUAR, Code-SLS-WHT-6953BIUFSM) |
| 464 | Providing and fixing WC Bowl with Cistern for Coupled WC with PP Soft Close Seat Cover, Hinges, DualFlush Cistern Fitting, Fixing Accessoriesand Accessories Set, Size: 375x650x790 mm,P Trap-180 mm. (Ref Model: JAQUAR, Code-SLS-WHT-6751P180PPZ) |
| 465 | Providing and fixing Health Faucet with 8mm Dia, 1 Meter Long Flexible Tube & Wall Hook ( Ref Model: JAQUAR, Code-ALD-CHR-573) |
| 466 | 450mm Long Braided Hose with Two 15mm Nuts & Rubber Washers Without Nipple (Ref Model: JAQUARALD-805B) |
| 467 | Providing & Fixing Wall Hung Integrated Basin with Fixing Accessories,Size: 530x460x400 mm (Ref Model: JAQUAR, Code-OPS-WHT-15803) |
| 468 | Providing and fixing Toilet Roll Holder with Stainless Steel Flap ( Ref Model: JAQUAR, Code-ACN-1153S) |
| 469 | Providing & fixing Soap Dispenser - Push Button capacity: 0.8L material: ABS finish: white/smoked ( Ref Model: JAQUAR, Code-SDR-WHT-DJ0010FN) |
| 470 | Providing and fixing Bottle Trap 32mm Size with 300mm & 190mm Long Wall Connection Pipes & Wall Flange (Ref Model: JAQUAR, Code-ALD-SSF-769L300X190) |
| 471 | Providing, Fixing Towel Ring Square with Round Flange. (Ref Model: JAQUAR, Code-CPA-CHR-1121) |
| 472 | Providing and fixing Coat Hook. (Ref Model: JAQUAR, Code-ACN-CHR-1161N) |
| 473 | Providing and fixing Towel Rack 600mm Long WithoutLower Hangers but with 3 hooks, Stainless Steel (Ref Model: JAQUAR ACN-1181FHS) |
| 474 | Providing ,Fixing Flush Valve Complete with 32 mmSize Control Cock with Elbow Set& Wall Flanges (NEL Size) (Ref Model: JAQUAR, FLV-1015NEL) |
| 475 | Providing and fixing C.P. brassPillar Cock cock (Ref Model: JAQUAR, Code-KUP-35001PM) |
| 476 | Providing and fixing C.P.Angular Stop Cock with Wall Flange of approved quality with Wall Flange (Ref Model: JAQUAR, Code-KUP-35053PM) |
| 477 | Providing and fixing Shower Basket (Ref Model: JAQUAR, Code-ACN-1177N) |
| 478 | Concealed Body for Joystick Diverter 40mm Cartridge with Button Assembly, (Button On Top) But without ExposedParts (Ref Model: ARC-87065C) |
| 479 | Providing & Fixing Single Lever Wall Mixer 3-in-1 Systemwith Provision for both Hand Shower and Overhead Shower Complete with 115mm Long Bend Pipe, Connecting Legs &Wall Flange (without Hand & Overhead Shower) (Ref Model: JAQUAR, KUP-35125PM) |
| 480 | Providing & Fixing Overhead Shower 200X200mm SquareShape Single Flow (ABS Body Chrome Plated with Gray Face Plate) with Rubit Cleaning System (Ref Model: JAQUAR, OHS-35497) |
| 481 | Providing & Fixing Hand Shower 100mm Round ShapeSingle Flow (ABS Body Chrome Plated with Gray Face Plate) with Rubit Cleaning System (Ref Model: JAQUAR, HSH-1937) |
| 482 | Supply,Installation, testing and commissioning of Water Heater complete with heavy gauge hot and cold water flexible pipe connections, Nano polymer coated tank, 0.8 MPa pressure ,of approved make complete with all necessary material as directed by Engineer - in - Charge.minimum.25 L Storage Capacity, Slim Design for Modern Bathrooms(Ref Model: Racold Omnis Slim 25L, AO Smith HAS-X 35L, Havells ORIZZONTE 4S 25 L) |
| 483 | Providing & Fixing Waste coupling 32mm Size Full Threadwith 80mm height (Ref Model: JAQUAR, ALD-705) |
| 484 | Providing & Fixing SS Drain Jaali |
| 485 | Providng & Fixing Bevelled Edge Mirror 5 mm thick Over a backing ply of 6 mm thick with decorative stud type screws at each corner (6 mm backing ply shall be paid separately under relevant item). |
| 486 | Providing & Fixing Glass Shelf 600mm Long (Ref Model: JAQUAR ACN-1171N) |
| 487 | Providing & Fixing Corner Glass Shelf (with Bracket) (Ref Model: JAQUAR ACN-1173) |
| 488 | Providing and fixing Stainless Steel AISI 304 kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required, all inclusive including drain piping and fittings.Features:36 inch (91.4 cm) minimum base cabinet widthDouble-equal bowlsRounded .39 inch (10 mm) cornersBowls slope towards drains to minimize water pooling10 inch (25.4 cm) depth provides generous workspaceSilentShieldโข sound-absorption technology offers quieter performanceAnti-condensation coating protects base cabinet from water damageNo faucet holes; requires wall- or counter-mount faucet3.58 inch (91 mm) drain openingRear drains increase workspace in the sink and storage space underneathSink strainers keep large items from passing into the drain(Make: Kohlar, Glen, Carysil, Nirali) |
| 489 | External/Internal Drainage Providing and fixing soil, waste and vent pipes |
| 490 | Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings(door or plain) viz elbolws, bends, tees, junctions, shoe bends, couplers, offsets, cowel etc. complete including jointing with solvent cement including GI supports, cutting and making good the walls wherever required. Nothing extra will be paid for supports.(Vertical Soil, waste, balcony waste & rain water pipes) 110 mm OD |
| 491 | Providing and fixing 100mm dia nominal bore uPVC pipe (Class-III)-IS:4985 inlet fitting approximately upto 300mm long above the trap with one or more 40 OD/ 50OD/63 OD/75OD holes for jointing waste pipes from waste appliances jointed and sealed with epoxy based sealant complete.For waste pipes |
| 492 | 40 OD uPVC pipe |
| 493 | 63 OD uPVC pipe |
| 494 | Providing and fixing uPVC floor drain consisting of PVC reducing elbow 110 x 63mm (Grating and pvc pipe to be paid separately), complete as directed by the Project Manager. |
| 495 | Water Supply Works |
| 496 | Providing and fixing CPVC Ball Valve with setting and gland of superior quality having minimum working pressure of 16 kg/cm2. |
| 497 | 20 mm nominal bore |
| 498 | 25 mm nominal bore |
| 499 | 32 mm nominal bore |
| 500 | Supplying, fixing, testing and commissioning of CPVC butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : |
| 501 | 50mm dia. |
| 502 | 65mm dia. |
| 503 | 80mm dia. |
| 504 | 12 GAIL Alaya - Elevator - Item rate |
| 505 | GAIL ALAYA - ELEVATOR WORK |
| 506 | ELEVATOR WORK |
| 507 | Supplying, installation, testing & commissioning of 8 Passenger (544 Kg), Gearless type,Machne room-less passenger lift of any of M/s OTIS, M/s Kone M/s Thyssenkrupp, M/s Schindler, Lifts make having contract speed 1.0 MPS serving different floors in the lift shaft as per detailed specifications as under and additional details given in schedule of technical particulars. Provisions of General CPWD specifications for lift works are to be followed. |
| 508 | Technical Specifications as below and as per Annexure A to Elevator Works of Tender Document |
| 509 | Speed - 1.0 Metre/Sec. |
| 510 | Floor - 7 stops |
| 511 | Travel - 24.0 Mtr. (Approx.) |
| 512 | Stop & Opening - 7 Stops & 7 Openings (One side only) |
| 513 | Type and Position of Machinery - Gearless type, Machine Room-less |
| 514 | Controller - Micro processer based AC variable voltage & variable frequency Control |
| 515 | Automatic rescue device complete with dry maintenace free batteries as required. |
| 516 | Operation - Microprocessor based Simplex Full Collective with / without attendant. |
| 517 | Power - 415 V ยฑ10%, 3 Phase, 50 Hz, AC |
| 518 | Type or Design of Lift Car - Silver Grace SS Hairline Finish |
| 519 | Car door - 2 Panel Automatic Left Side Opening door with ACVF drive SS Hairline Finish |
| 520 | Door operation - Full Height Infra-red cross-multi beam |
| 521 | Landing doors - 2 Panel Automatic Left Side Opening door SS Hairline in on 7 floors |
| 522 | Car operating Panel / Landing operating panel - Car operating panel with braile symbol luminous buttons and braile illuminated push buttons on all landing in Stainless Steel Mirror finish. |
| 523 | Hand rail - Round Handrail in Hairline SS Finish provided on Rear Wall of Car |
| 524 | Voice announcement system - In car to announce the position of the elevetor in hoist way as the car passes or stop at a floor served by the elevator |
| 525 | Intercom system - 3-way intercom |
| 526 | Clear Opening of Doors - 800mm x 2000mm (Wide x Height) |
| 527 | Car Dimensions - 1100 x 1300x2200 mm ( Width x depth x Height). |
| 528 | Hoist Way Dimensions - 1750 x 1750 mm(Width x Depth) |
| 529 | Overhead - 3800mm |
| 530 | Pit Depth - 1400 mm |
| 531 | Landing Operating Panel - Individual landing operating panel for each elevator |
| 532 | Drive - ACVVVF |
| 533 | ARD - TO BE PROVIDED with dry maintenance free batteries with 30 min.backup, Voice Announcement system in the Car to announce position of the elevator in the hoistway as the car passes or stops at a floor served by eelvator & intercom facility to be provided. Also, braille buttons for differently abled persons to be provided. Door Sensor (full door height) to be provided. All necessary signboards should also be provided. |
| 534 | The scope also includes getting clearance from the respective government authority for safety clearnace and license for operation of the lift. However, the liasoning amount shall be paid separately as per relevant item under liasoning head of the SOR. (Makes: Kone, TK Elevator, OTIS, Schindler) |
| 535 | Lift Panel |
| 536 | INCOMER |
| 537 | 1 No. 63amps 4P MCCB(36KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. |
| 538 | 1 No.63 amps ATS |
| 539 | METERING & INDICATION for each Incomer |
| 540 | 1 set of R,Y,B phase indicating lamps |
| 541 | Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA, harmonics upto 15th order & %THD) with RS-485 Port. |
| 542 | Sets of 63/5A, CL-1, 15VA CTs for measuring. |
| 543 | Sets of phase indicating lamp with 2A control MCBs. |
| 544 | BUS-BAR |
| 545 | 80 A TPN Aluminium Bus Bar with colour coded PVC Sleeves |
| 546 | OUTGOINGS |
| 547 | 2 Nos. 63 Amp TP MPCB |
| 548 | 2 Nos. 63 Amp TP MCB |
| 549 | 1 Nos.40 Amp DP MCB |
| 550 | LIFT APPROVAL - Following are the scope of work:- 1.Preparation of drawing & document. 2.Submission of drawing & document to the concerned authority / office with a copy of all correspondence to EIC. 3.Payment of drawing approval fees. (Shall be reimbursed on production of original challan/ bill) 4.Submission of work completion report as per approved drawing. 5.Arranging the inspection of the installation. The traveling, lodging, boarding and other expenses of statutory authorities for inspectons shall be born by the contractor. 6.Follow up at various level. 8. Commissioning of Lift complete as per norms of the Building Approval Authority/ any other regulator as required and instructed by Engineer- In-Charge 10. Any other related job to obtain approval and running permission. Lump sum rate is to be quoted for one complete activity unit/job (EA means 1 Job here) |
| 551 | 14 GAIL Alaya - Electrical - Item rate |
| 552 | GAIL ALAYA - ELECTRICAL WORKS BOQ |
| 553 | Distribution Boards |
| 554 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 555 | 6 way, Single door |
| 556 | 8 way, Single door |
| 557 | 12 way, Single door |
| 558 | Fittings & Fixtures |
| 559 | Supply of 4ft Linear LED luminaire of 20W delivering an initial system lumen of 2000 lumens & the luminaire shall be with system efficacy โฅ 100 lm / W. The luminaire Housing shall be made of extruded Aluminium & the diffuser shall be of polycarbonate/PMMA. The operating CCT shall be 6500K with CRI of โฅ80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD โค 20% & PF โฅ 0.95 , 50,000 Hrs LED Life with L70 Criteria, IP20. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard. Ref Wipro Cat No.: LL20-281-XXX-65-AL1 or Equivalent Philips, |
| 560 | Supply of 2ft Linear LED luminaire of 10/12 W delivering an initial system lumen of 903 lumens & the luminaire shall be with system efficacy โฅ 90 lm / W. The luminaire Housing shall be made of PC & the diffuser shall be of polycarbonate/PMMA. The operating CCT shall be 6500K with CRI of โฅ80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD โค 20% & PF โฅ 0.95 , 50,000 Hrs LED Life with L70 Criteria, IP20. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard. Ref Wipro Cat No.: LL20-111-XXX-65-NE |
| 561 | Supply of LED bollard 800mm height with system wattage of 8W delivering minimum system lumen of 560 lumens.CRCA powder coated housing ,with PMMA diffuser symetrical distribution. The operating CCT shall be 5700K with CRI of โฅ70.The lumiaire shall be with BIS registered elctronic driver with Input voltage range of 180 to 270V , internal driver with efficiency โฅ 80%, THDโค25% & PF โฅ 0.95 ,minimum surge protection of 2KV, 50,000 Hrs LED Life with L70 Criteria, IP65 Ingress protection and ambient operating tempretature 0-45ยฐ C. Similar or equivalent to Ref Wipro Cat No.:CRLA11008HP57-08 or equivalent Philips |
| 562 | Supply of post top Luminaire consuming a system wattage of 35W (ยฑ10%) & the luminaire shall be with system efficacy โฅ 95lm/W. Housing: Die Cast Aluminium . IP65 , Optics: Acrylic Clear Diffuser. The operating CCT shall be 5700K with CRI of โฅ70. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD โค 10% & PF โฅ 0.9, 50,000 Hrs LED Life with L70 Criteria.The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 4KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard. Ref Wipro Cat No.:LP07-431-XXX-57-CL or equivalent Philips |
| 563 | Supplying and erecting rimless full glow LED square / circular (concealed or recessed) Max. 24 W down lighter/ Panel Light having pressure die-castaluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3years warranty. |
| 564 | Supplying and erecting rimless full glow LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3years warranty. |
| 565 | Supplying and erecting rimless full glow LED square / circular 12W down lighter having pressure die-cast aluminiumhousing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete. |
| 566 | Supplying and erecting rimless full glow LED square / circular 3 to 6 W down lighter having pressure die-cast aluminiumhousing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete. |
| 567 | SITC LED Rope Light with Connector at desired places as per the directives of EIC. Ref Model: Philips Marathon or Eq as per list of makes. |
| 568 | Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg.,THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. |
| 569 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, decorative and stylish ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. aluminium baldes blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required of apporved make and shade as per the directives of EIC. |
| 570 | Providing & Fixing with connection, Fresh air exaust fan 300 mm of approved make and shade as per the directives of EIC |
| 571 | Providing & Fixing with connection, high speed wall mount fan of 400 mm of approved make and shade as per the directives of EIC. |
| 572 | Provision of Supply & Installation Items like Decorative Lights, Painting Lights, Hanging Lights, Chandlier etc. The amount shall be paid on actual tax paid invoice plus 10% to cover Contractor Profit & Overheads including fixing and making connections. |
| 573 | Cable & End Terminations |
| 574 | Supply, installation, testing & commissioning of 02 Nos. advance maintenance free Chemical Gel Earthing of 10 feet long 5/8\\" dia Rod moleculerly bonded with 250 micron copper coating and treated with SS bolt and nuts with 3 bag of 10 Kgs of RESLO (mixture Sulphate, Silica, Alumina, Iron Oxide, Titanium Oxide, Calcium Oxide, Potassium Oxide, Chloride, Magnesium Oxide, Sodium Oxide, Zinc Oxide, etc) Resistance Lowering Grounding Minerals. The chemical compound is tested and certified by International accredited and BIS (Bureau of Indian Standards) accredited laboratory. The testing laboratory is ISO 9001 & ISO 14001 certified. Make: LPI (Australia) / equivalent |
| 575 | Raceways & Cable Trays Cable Tray |
| 576 | Supply, Installation, Testing and commissioning of floor Mounted GI Raceways of below mentioned sizes.Including all bends, Joints, Cover Sheet, End Caps, External Angles, Internal Angles, Flat Angles, Flat Junctions, Flat Tee, Flat Cross, Clips, Separation Partition etc. etc. and all other accesories required during installation shall be in scope of contractor. Contractor to quoate as per Drawing and site no additional items of accesories shall be paid extra. Approved Make- |
| 577 | 100mmX40mm Single compartment |
| 578 | 150mmX40mm Single compartment |
| 579 | Supply, Installation, Testing and commissioning of below mentioned Floor Junction Box made up of GI with 1.6MM sheet gauge |
| 580 | Floor Full Back Box( 150 x 150mm) |
| 581 | Floor Full Back Box(200 x 200mm) |
| 582 | 15 GAIL Alaya - LV - Item rate |
| 583 | LOW VOLTAGE WORKS BOQ |
| 584 | DATA & TELEPHONE |
| 585 | Supply, Installation, testing and commissioning of Cat6A Tool less Information outlet for Data & Voice. Cat6A U/UTP built in crimping mechanism with capability of retermination without refreshing the wires. LCS2 Toolless RJ45 Information outlet with insertion cycle (in & out) should be 2500 times (I/O) along with front side Label holder and transparent shutter. The Information Outlet connector shall be of gold/nickel, thickness of gold > 0.8 ฮผm.The connectors shall be compatible as per IEEE 802.3af standard for POE application. . |
| 586 | SITC of Double port Face Plate : Polycarbonate Hi-Grade Plastic FR Grade & UV Resistant 850 degree C/ Glow Wire Test. The face plate should be compatible for Cat5e, Cat6 range of RJ45 and AV connectors.The face plate Size should be of minimum 86x86mm. |
| 587 | Supply, Installation, testing and commissioning of 24 port Cat 6A 19\\" Modular Toolless Patch Panel (loaded) enable all possible combinations of the various types of cable. mounted on the same panel by using various toolless connector blocks/modules. Have a metal structure enabling them to be durably fixed to the uprights of the 19โ chassis and assuring automatic grounding between toolless RJ-45 connectors, the panel, and the 19โ uprights of the enclosure. Include rear cable support with plastic cable guides to hold cable without need for cable ties. Include quick mounting system to mount the panel into the 19โ rails without use of cage-nuts. Front Removal IO's option for maintenance and trouble shooting with 6 Different Colours Labels for Labelling & Identification of Individual Ports. Tested and guaranteed under dual circuit IEEE PoE+ up to 50W for up to 2500 on-load connections / disconnections. |
| 588 | Supply and drawing of UTP 4 pair 23 AWG CAT 6A LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required conforming to the following standards like ANSI/TIA 568 C.2, IEC 60332-1, IEC 60754-1. Cable Dia 8.0 mm with beneding radius -4 X Cable Diameter Operates at frequency of 500 Mhz . |
| 589 | Supply, Installation, testing and commissioning of CAT6A UTP 24 AWG Patch Cord - 1 mtr with cross separator , Manufactured from stranded wires for longer flex-life , Minimum length of 1m, and maximum length of 5m Conforming to the following standards like EN 50173, ISO/IEC 60603-7 & 11801/IEC 60332-1, UL VW-1 |
| 590 | Supplying & Fixing of Fiber Optic SC style fully loaded Patch Panel (FOPP), 19\\" Rack Mount ,Shall have all accessories including coupler plates pre loaded with 24 Nos of LC couplers (OM3) with all accessories complete in all respect. Pigtails Should Complie to ITU-G657.B-Bend insestive fiber.. |
| 591 | Supplying & Fixing of Fiber Optic SC style fully loaded Patch Panel (FOPP), 19\\" Rack Mount ,Shall have all accessories including coupler plates pre loaded with 12 Nos of LC couplers (OM3) with all accessories complete in all respect. Pigtails Should Complie to ITU-G657.B-Bend insestive fiber. |
| 592 | Supplying & Fixing of Fiber Optic Patch Cable (SC-SC), 3 Mtrs. Long, ISO/IEC-11801-OM3 50# Duplex, LSZH,All patch cords shall conform to EIA/TIA-568C.3 and ISO/IEC-11801,Shall be Duplex Multi Mode Fiber Optic Patch Cords OM3 50#,Shall support network line speeds up to 10 Gbps.Shall have SC-SC Connector connectors at the ends complete in all respect.. |
| 593 | Supply & Fixing of OM3 50/125ฮผ Type Pigtails of ISO/IEC-11801-OM3 Pigtails with SC Type Connectors,pigtails for terminating fibers on the FOPP complete in all respect. Make-Siemon/Panduit/Legrand . |
| 594 | Supplying, Installation, Testing & Commissioning of 50ฮผ, 6-core Multi mode OM3 metallic armored Fiber cable as per ISO/IEC-11801, Shall be able to meet Gigabit & 10 Gigabit Ethernet performance up to 300 meters requirement specified by IEEE 802.3z (1000 Base-X) & IEEE 802.3ae (10G Base-X) Tensile load should be 4000 Newton or higher and crush resistance should be 4000 Newton or higher ,The attenuation @ 850 nm should be โค 2.7 (Max) db/Km and @ 1300 nm should be โค 0.7 (Max) dB/Km, the fiber construction can be unitube or multitube, but tensile and crush resistance parameters should be matched, the jacket shall be FRLSZH complete in all respect. Make-Siemon/Panduit/Legrand . |
| 595 | Enclosure: 32 U Floor Standing Rack & Modular Construction of the rack made of 4 vertical, 4 horizontal & 4 depth aluminum/MS bolted and joined together with Links and Corner Block. Enough support channel to equate the load evenly and castor provision at bottom side, Degree of Protection: The unit should have a minimum of IP 20, Compliance with standards: UL, IEC, Earthing: All cabinet components (doors, side panels, top panels, 19โ rails, pdu brackets) shall be grounded directly to the frame using Dual Copper plated earth stud of suitable rating on main Metal parts for better electrical continuity, Weight Capacity: Load Capacity of minimum 1200 Kg, Coating: Powder coated black with fine texture โ 60 to 80 uM, Corrosion Resistance:Salt spray test resist upto 500 Hrs, Top and Bottom: Top cover consist of Fire Retardant Brushes and Fire retardant ABS plastic / MS frame for cable and fiber entry to rack from fiber runner and copper cable pathway system. This consists of Brush with 2 line of brush system UL Certified Fire Retardant Brushes and Fire retardant ABS plastic / MS frame, Mounting Angle: 19\\"Upright adjustable in depth, equipment mounting angles with square slots to accommodate M6 cage nuts, powder coated texture finish. It contains U printing pattern which can be read from down to up and vice versa, Mounting Angle: 19\\"Upright adjustable in depth, equipment mounting angles with square slots to accommodate M6 cage nuts, powder coated texture finish. It contains U printing pattern which can be read from down to up and vice versa, Castor: Set of 4 castors with levelling feet, 2 brakes on front side and 2 without brakes, Mounting Hardware Packets with set of M 6 screw, Cage Nuts and Washer set of 10 or 20, Network Rack: 32U 800W x 1200D (Height x Width x Depth) ,Single Honeycomb/ Perforated door (Front Side), Double Honeycomb/ Perforated door (Rear Side), Zero U tool-less mounting PDU. 2 no PDU, 230 V AC-2 no. for each PDU, 18 no of 6 AMP socket(c13 type);6 no of 16Amp socket(c19 type) with 2 no of MCB 16/32 Amp. PDU of standard make like APC, Schnider, 4 no of cooling fan. Make: APW/Wellrack/Rittle |
| 596 | EPABX System |
| 597 | Supply Installation, Testing and Commissioning of IP Phone with minimum 2 Line display and minimum 08 Key of following makes Unify/Progility/Coral/Alcatel. The instrument shall be in line with technical specifications of IP Phones of the tender document. |
| 598 | FIRE FIGHTING |
| 599 | Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required2 x 1.5 sq.mm |
| 600 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
| 601 | 25 mm dia |
| 602 | 50 mm dia |
| 603 | 100 mm dia |
| 604 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2 x 1.5 sq. mm |
| 605 | DETECTORS Supply, Installation, Testing & Commissioning of Intelligent Combination Heat Photoelectric Smoke Detector integrates photoelectric detection, fixed temperature and rate of rise detection technology. The smoke sensor and heat sensor are integrated in mechanism and circuitry structure,Electrically addressed,LED indication for normal status can be turned off by handheld programmer ,should have Strong environmental adaptability with drift compensation,Self-diagnostic facility, Reed switch test,Dirty chamber checking facility, Fire LED allows 360ยฐ viewing, 2 levels smoke sensitivities programmable, option to connect remote indicator. Designed to meet UL 268 / UL521 |
| 606 | SMART LOCKS |
| 607 | Supply & Installation of MyGate Lock Plus Black on Existing Doors of Townships, Guests House Rooms at GAIL Alaya and GAIL Ashiyana Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 ยท All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail