Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | JHARGAON SEVASHRAM UNDER LEPHERIPARA BLOCK |
| 2 | Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works upto and including 1.5metre depth and stacking the soil upto a lead of 100 metre and including dewatering, removing slush, shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge. |
| 3 | Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth: consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer-In-charge. |
| 4 | Boundary Wall back filling available excavated earth ( excluding rock) in trench, plinth, sides of foundation etc. |
| 5 | Supplying of filling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc., all complete as per the specification and direction of Engineer-In-Charge. |
| 6 | Disposal of surplus excavated materials by mechanical means from the work side etc. complete. upto 5km. Lead |
| 7 | New building |
| 8 | Boundary Wall |
| 9 | Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties and cost of all labours,labour cess, T&P etc complete as per specification & direction of the Engineer-in-charge. |
| 10 | First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge. |
| 11 | Providing and laying in position ready mixed M-25 grade concrete having compressive strength at 28 days test not less than 250 kg/ sq.cm for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and excluding reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, and hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,Labour cess and T&P required for the work improve workability without impairing strength and durability as per direction of the Engineer - in - charge. |
| 12 | Foundation & plinth |
| 13 | Footing |
| 14 | Pedestal |
| 15 | Coloumn from Pedestal top to NGL |
| 16 | Coloumn from NGL to PL |
| 17 | Plinth Beam |
| 18 | Ground floor |
| 19 | Coloumn from PL to Ground floor Roof |
| 20 | Roof beam |
| 21 | Roof slab |
| 22 | Lintle |
| 23 | Staircase |
| 24 | Chajja |
| 25 | Platfrom |
| 26 | R.Dining slab |
| 27 | First floor |
| 28 | Coloumn |
| 29 | Roof beam |
| 30 | Roof slab |
| 31 | Lintel |
| 32 | Staircase |
| 33 | Chajja |
| 34 | Terrace floor |
| 35 | Column |
| 36 | Roof beam |
| 37 | Roof slab |
| 38 | Lintel |
| 39 | BOUNDARY WALL |
| 40 | R.C.C. in footing |
| 41 | RCC in Tie beam |
| 42 | RCC in Pedestal |
| 43 | GROUND FLOOR |
| 44 | RCC in Coloumn |
| 45 | RCC in Band |
| 46 | RCC Roof slab |
| 47 | RCC Roof beam |
| 48 | Pathway |
| 49 | Cutting,straightening coiled or bent up HYSD/TMT 550D Reinforcement Bars confirming to IS 1786:2008 welding or jointing if necessary ,bending, binding,tying the grills as required for R.C.C. works,providing Fan Hooks where necessary and hoising,lowering and placing the same tin proper position according to the approved designs and drawings in all floors including cost, conveyance, loading, unloading and taxes or HYSD/TMT Reinforcement Bars and Binding wieres of 18 to 20 gauge required for the work cost of all labour,T&P and scaffolding complete in all respect as directed by the Engineer-in-charge(Payment will be made according to the actual/proper weight of HYSD/TMT Reinforcement Bars and Binding wires consumed in the particular work only) |
| 50 | New Building |
| 51 | Ground floor |
| 52 | First Floor |
| 53 | Terrace Floor |
| 54 | Total= |
| 55 | Fly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12 c.m x 8 c.m in Super structure having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties , all taxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 56 | Ground floor |
| 57 | First Floor |
| 58 | Terrace Floor |
| 59 | BOUNDARY WALL |
| 60 | Fly Ash Brick Masonry in cement mortar of mix (1:4) using Fly Ash bricks of size 25c.m x 12 c.m x 8 c.m in Superstructure having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties ,all taxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 61 | Ground floor |
| 62 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties, with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect and specification and direction of the Engineer in charge. (External wall) |
| 63 | New Building |
| 64 | First Floor |
| 65 | Terrace floor |
| 66 | Providing 16mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary)including watering and curing, rounding of corners etc. complete with cost,conveyance,loading, unloading, royalities and taxes of all materials,cost of all labour,T&P and scaffolding required for the work etc. as directed by the Engineer-in-charge. |
| 67 | Ground Floor |
| 68 | First Floor |
| 69 | Terrace Floor |
| 70 | R.Dining |
| 71 | Ground floor |
| 72 | Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance and royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 73 | Ground Floor |
| 74 | First Floor |
| 75 | R.Dining |
| 76 | Ground floor |
| 77 | Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, all materials, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. |
| 78 | Ground Floor |
| 79 | First Floor |
| 80 | Terrace Floor |
| 81 | R.Dining ground floor |
| 82 | Priming one coat with water bound wall primer. |
| 83 | Ground Floor |
| 84 | First Floor |
| 85 | Terrace Floor |
| 86 | BOUNDARY WALL |
| 87 | R.Dining ground floor |
| 88 | Distempering two coats to walls with distemper of approved shade on new work to give an even shade |
| 89 | Ground Floor |
| 90 | First Floor |
| 91 | Terrace Floor |
| 92 | Wall painting two coats with Weather coat paint (1st quality) exterior grade of approved make & with a approved quality primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge. |
| 93 | Ground Floor |
| 94 | First Floor |
| 95 | Terrace Floor |
| 96 | BOUNDARY WALL |
| 97 | R.Dining ground floor |
| 98 | Providing & painting two coats of Plastic emulsion paint with 1st quality of approved brand and manufacturer to give an even shade as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. |
| 99 | Ground Floor |
| 100 | Supplying,Providing & laying Double charge mat finished vitrified tile flooring using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13755 of 600mmx600mm of premium quality in floors, treads on steps and landings on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the vitrified tile if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. |
| 101 | Ground Floor |
| 102 | First Floor |
| 103 | Supplying, fitting & fixing of Double charged vitrified wall tiles 600mmx600mm in dadoes of approved make laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) and filling joints with slurry including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge. |
| 104 | Ground Floor |
| 105 | First Floor |
| 106 | Supplying, fitting and fixing of Antiskid Ceramic Floor Tiles in flooring using special plain / printed series Ceramic Floor Tile of premium grade ( having minimum thickness 7 mm to 8 mm & size 400 mm x400 mm, confirming to I.S 13755 of approved quality and shade in floors, treads on steps and landings on 20 m.m thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened & washed sharp river sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments (Tiles are to be immersed in the water for required time before use) of approved make to match the shades of the Ceramic Floor Tiles if required including cost, conveyance, loading, unloading, stacking, royalties , all taxes,rubbing, cost of all Labour, Labour cess ,Sundries, T&P required for the work , Watering , Curing for required days , cleaning the flooring space manually etc. complete in all respect as directed by the Engineer-in-charge. |
| 107 | Ground Floor |
| 108 | Supplying, fitting & fixing of 30cm x 20cm/20cm x 20cm special plain/printed series Ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm confirming to IS 13753 laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge. |
| 109 | Ground Floor |
| 110 | Providing Mat finished Granite stone prepolished 20mm thick of area above 0.40 Sqm in flooring of approved quality, colour and size in floors, treads on steps and landings in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the granite tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, Labour cess ,sundries, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. |
| 111 | Ground Floor |
| 112 | First Floor |
| 113 | Terrace Floor |
| 114 | Providing Mat finished Granite stone prepolished 10mm thick of area above 0.40 Sqm in dado/skirting,riser of steps of approved quality, colour and size in dado/ skirting,riser of steps,wall on 12mm thick bed of cement mortar of mix (1:3) laid in proper plumb and line with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the granite tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, Labour cess ,sundries, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. |
| 115 | Ground Floor |
| 116 | First Floor |
| 117 | Terrace Floor |
| 118 | Supplying, fitting & fixing of Industrial vitrified tiles (30x30)cm in floors of approved make laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with slurry including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge |
| 119 | Providing and fixing factory made single extruded 30 mm thick WPC solid decorative type Flush door shutter with both side 1mm thick laminate finish of required size comprising of virgin polymer of K value 58-60calcium carbonate and natural fibers and non-toxic additives having minimum density of 650kg/cum and screw withdrawl strength of 1800N (fACE) & 900N (Edge) minimum compressive strength 50 N / MM2,modulus of elasticity 850N/mm2, and resistance to spread of flame of class A Category with property of being termite/borer proof , water / moisture proof and fire retandant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melted adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screw,SS Handle, Door stopper, SS Hinges, Sliding door bolt etc. all as per direction of EIC. (Make: Century /Floresta/ ALSTONE) |
| 120 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat (Graphite grey colour) comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. ( Frame size 62 x 100 mm) (Make: Century /Floresta/ ALSTONE) |
| 121 | Providing and fixing factory made single extruded 25 mm thick WPC solid decorative type Flush door shutter with paint finish of required size comprising of virgin polymer of K value 58-60calcium carbonate and natural fibers and non-toxic additives having minimum density of 650kg/cum and screw withdrawl strength of 1800N (FACE) & 900N (Edge) minimum compressive strength 50 N / MM2,modulus of elasticity 850N/mm2, and resistance to spread of flame of class A Category with property of being termite/borer proof , water / moisture proof and fire retandant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melted adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screw,SS Handle, Door stopper, SS Hinges, Sliding door bolt etc. all as per direction of EIC. (Make: Century /Floresta/ ALSTONE) |
| 122 | Supplying and Fixing of M.S. Window Grill made out of M.S Flat conforming to IS 2062/2006 excluding the cost of Red Oxide Primer as per the design approve by E.I.C including cost, conveyance of all materials,priming,and labour for fitting fixing etc.complete as per the instruction of Engineer-in-Charge |
| 123 | Painting two coat with approved synthetic enamel paint to new wood & iron work over a coat of primer including cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge. |
| 124 | Ground Floor |
| 125 | First Floor |
| 126 | Terrace Floor |
| 127 | Supplying and Fixing of Elastomeric membrane of 200 x 2mm size for expansion joint sealing from approved manufacturer fixing with epoxy adhesive of approved quality complete |
| 128 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. |
| 129 | Providing and laying grading conc. 25mm (avg. thickness) cement concrete of required slope of ix 1:2:2 mixed as per manufacturer's specification on top of the slab includimg cement slurry |
| 130 | Providing and laying approved colour 60 mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with storng vibratory compaction of approved size, design & shape, laid in required colour and pattern over and including 75mm thick sand filling.as per drawing, specification and direction of Engineer-In-charge. |
| 131 | 4 cm thick grading concrete (1:2:4) on roof slab with 12mm & down grade size black hard granite chips for old work. |
| 132 | Ground Floor |
| 133 | Sunken treatment |
| 134 | Stage 1: Cleaning of concrete surface to remove dust oil |
| 135 | Making plinth protection 50mm thick of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well ramed, consolidated and grouted with fine sand and finishing the top smooth including shuttering at the edges, excavation and disposing of surplus earth with a lead of 100m complete as per direction of Engineer-in-charge. |
| 136 | DISMANTLING & DISPOSAL. |
| 137 | Dismantling of brick or stone masonary in lime or cement mortar above 3 mtr height including stacking the useful materials for reuse & removing the debries within 50 mtr. |
| 138 | Dismantling and removing R.C.C coloumns beams slab staircase landing lintels including stacking the useful materials for reuse and removing the derbris within 50m leads |
| 139 | BORE WELL |
| 140 | Construction of 1 nos production wells including scientific source finding through consolidated and unconsolidated rock with down the hamer drilling rig or combination rig with pvc pipe and installation of submersible pump set with all acessories |
| 141 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the engineer in charge including use of own rig with its accessories ,tools and plant and consumables etc for lowering of 200mm/150mm dia G.I.P.V C/M.S casing pipes for housing fitted with socket and with or without well screen as for the necessity for soft ,medium,hard and boulder formation( G.I/P.V.C/M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well) 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only |
| 142 | Drilling of 200mm dia bore (1 nos ) |
| 143 | 00mtr to 60mtr |
| 144 | Drilling of 150mm dia bore |
| 145 | 61mtr to 120mtr (2 nos ) |
| 146 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity form ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and dotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials |
| 147 | Lowering of 200mm dia P V C casing pipes |
| 148 | 00mtr to 60mtr |
| 149 | Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 PART-II specification length of pipe (laying length) will be 3 mtrs.The pipes shall be supplied with both external threaded with free socket. The pipe having external thread at one end i.e. female & or belled end . The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber 'O' ring to make the joint water tight color of the pipe shall be blue The name of the manufacture along with batch.No class of pipe shall be stranded legibly of each pipe length |
| 150 | 200mm dia PVC (sch-80) pipe (As Per SoR -2022) |
| 151 | Supplying all materials, labour, T & P and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all com |
| 152 | Cleaning & developing the tube well with supply of compressor worked till clear & adequqte discharge is obtained from the tube well including supply & use of all necessary equipment & labour as per directin of the Engineer in charge |
| 153 | By DTH Rig |
| 154 | Supplying all materials, equipments,labour & conducting reconnaissance survey , integrated Hydrological & Geophysical (Electrical resistivity Method) survey & selection of potential source for exploration of ground water including selection & recommend |
| 155 | Rocky terrain with boulder formation for 300m depth |
| 156 | Supplying all materials, labours, T&P and providing fitting & fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase /1 phase line voltage ranging from 320 volt to 450 volt conforming to Si 8034/89 with following specifications with suitable control panel ,jointing with GI/PVC/HDPE pipes,electrification,testing, commissioning ,trial running, conveyance of all materials to worksite , payment of taxex etc all complete as per specification & direction of the Engineer in charge (Texmo/crompton Greaves/ Kirloskar make) |
| 157 | 2HP Single phase 3 stage vertical/Horizontal submersible pump set at head renge of 30 to 54 mtr with discharge capacity 155 to 110 L P.M with outlet dia 32mm |
| 158 | Dol Control panel |
| 159 | 40mm dia steel short piece |
| 160 | Well cap |
| 161 | 50mm size CI bracket |
| 162 | 25 sqmm flat cable |
| 163 | 20 mm dia rigid UPVC pipes |
| 164 | Steel ropes with cover |
| 165 | Labour charges for lowering including transportation |
| 166 | Supplying all materials ,labour, T&P and providing and fixing to wall or celling and floor HDPE pipes and pipe fiting conforming to IS: 4984/2000(10KGF/SQCM) of the following nominal bore with clamps & joining by Fusion welding method including testing making good the wall celling & floor all complete as per specificaations 7 direction of the engineer in charge |
| 167 | 32mm dia HDPE pipe |
| 168 | Borewell Chamber |
| 169 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the engineer-in-charge.1.20x1.20x0.40= |
| 170 | Supplying all matrials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all complete as per direction of the engineer in charge. |
| 171 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering , curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the engineer in charge. In ground floor 1.20x1.2x0.15= |
| 172 | Supplying all matrials, labour, T&P and providing brick work with fly ash brick having crushing strength not less than 75kg/cm2 with dimensional tolerance 8 percent in cement mortar (1:6) including watering , curing, conveyance of all materials to worksite, payment of royalty, taxec etc all complete as per specification and direction of the engineer incharge. In F&P 2(1.15+0.65)X1.00X0.25= |
| 173 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and trying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the engineer in charge. In ground floor. |
| 174 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard brocken granite chips including watering, curing , conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the engineer in charge. In ground floor. |
| 175 | Supplying all maerials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering , curing, conveyance of all materials to worksite, payment of royalty, taxes etc all materials to worksite,payment of royalty, taxes etc all complete as per specification and direction of the engineer in charge. In ground floor (inside/outside) |
| 176 | INTERNAL P.H. & SANITARY WORK. |
| 177 | WATER SUPPLY. |
| 178 | Supplying, installing, fixing, jointing, testing and commissioning of approved make. Chlorinated Polyvinyl Chloride pipes (CPVC) SDR.11 pipes confirming to ASTM standards with necessary fittings for inetrnal toilet water supply upto 50 dia , and above 50mm dia pipe schedule 40 with fitting shall be schedule 80 ASTM IPS. The fittings and specials such as tees, elbows,couplers, bends, enlargers etc.,m with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement martor 1:1 restore the same original condition neately as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846 and above 50mm dia primer P-70, and solvent confirming to ASTM F-4931 / 724 All exposed pipe shall be painted with latex paint. (for shafts, basement ceiling ringmain Terrace & PRM).The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. Make:- Supreme/Ashirbad/AKG. |
| 179 | 20 mm dia C-PVC pipe (Oriplast/Supreme) |
| 180 | 25 mm dia C-PVC pipe (Oriplast/Supreme) |
| 181 | 40 mm dia C-PVC pipe (Oriplast/Supreme) |
| 182 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings etc. all complete as per P.H. specification and direction of Engineer-in-charge. 250 mm thick wall |
| 183 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages as per direction of the E.I.C. |
| 184 | Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of the Engineer-in-charge. |
| 185 | SANITARY FIXTURES. |
| 186 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Water Closet & cistern fitting (European type W.C. pan) of Hindware/Jaquar/Parryware with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer-In-Charge. |
| 187 | Supplying all materials, labour, T&P and fixing Health Faucet of Hindware/Jaquar/Parryware complete with Chromium plated brass brackets fixed to wooden plugs with Chromium plated brass screws as per specification and direction of the Engineer-In-Charge. |
| 188 | Supplying all materials, labour, T&P and fixing standard sized two way Bib cock of Hindware/Jaquar/Parryware of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. 15mm dia CP Two way bib cock with Flange. |
| 189 | Supplying all materials, labour T&P and fixing of Under Counter wash basins with bottle trap & cp fittings of Hindware/Jaquar/Parryware of approved make in all floor of approved quality including cutting the walls & floor and making good the damags with cement concrete e.t.c including all tsxes,duties,transportation e.t.c. All complete as per specification and direction of the Engineer-In-Charge.(Size: 560x430x195 mm) |
| 190 | Supplying all materials, labour, T&P and fixing standard sized pillar cock of of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 15mm dia brass pillar cock.(MAKE -JAQUAR) |
| 191 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C.sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer-in-charge. Swivel Mirror Rectangular Shape(630x450) |
| 192 | Supplying all materials, labour, T&P and fixing standard sized Chromium Plated Glass Shelf of Hindware/Jaquar/Parryware complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge. |
| 193 | Supplying, installing, testing and commissioning of approved make White Viterous urinals 3.8 LPM supported by CI/MS bracket duly painted, including CP brass waste with dome type grating, CP cast brass bottle trap with extension piece, wall flanges, automatic flushing systems for urinal to ensure flusing only immediately after use, comprising of all plumbing, electronic and electrical items. CP brass flush pipe with CP brass elbow, CP brass spreader, CP wall flange, infrared photo cells (Sensor), eyes electrically operated solenoid valve, gate valve, black box and necessary wiring in conduit from solenoid value to black box and to mains etc, complete. Including necessary wall cutting/chasing and making good, as required. , jaquar,Size:385x325x635mm,jaquar-URS-WHT-13253N |
| 194 | Supplying all materials, labour T&P and fixing URINAL FLUSH VALVE FLV-1095NG (Make: Jaquar) of approved make etc complete including cost of all materials complete as per PH specification and direction of Engineering-in-charge |
| 195 | Providing & Fixing granite slab with Table rubbed, edges rounded and polished of size 75x50 cm deep and 18mm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 as per direction of Er-in-charge. |
| 196 | Supplying all materials, labour, T&P and fixing standard sized Robe Hook of Hindware/Jaquar/Parryware complete with all as per specification and direction of the Engineer in charge. |
| 197 | Supplying all materials, labour, T&P and fixing standard sized 15mm dia angular Stop cock of Hindware/Jaquar/Parryware of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. |
| 198 | Supplying all materials, labour, T&P and fixing standard sized Chromium Plated soap case Hindware/Jaquar/Parryware complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge. |
| 199 | Supplying all materials, labour, T&P and fixing standard sized Chromium Plated brass towel ring of Hindware/Jaquar/Parryware complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge. |
| 200 | Supplying all materials, labour, T&P and fixing standard sized Chromium Plated brass towel rail of Hindware/Jaquar/Parryware complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge. |
| 201 | Supplying all materials, labour, T&P and fixing standard sized Chromium Plated Paper Holder of Hindware/Jaquar/Parryware complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge.jaquar CAN-1153S |
| 202 | Fixing of 32 mm dia Brass/GM Fulway Valve confirming to IS : 781-1995 of approved make as per specification complete as per direction of Er-in-charge. 32mm dia brass or gun metal full way valve.(Make- zoloto or equivalent.) |
| 203 | Fixing of 20 dia Brass/GM Fulway Valve confirming to IS : 781-1995 of approved make as per specification complete as per direction of Er-in-charge. 20mm dia brass or gun metal full way valve.(Make- zoloto or equivalent.) |
| 204 | EXTERNAL P.H.E & SEWAGE SYSTEM. |
| 205 | Supplying all materials, labour, T & P and constructing of Inspection chamber(IC) of the following inside size with 8 cm thick R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g. chips, foundation concrete (1:4:8) using 40mm size h.g. metal on bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mm x100mm size gully trap, 150mm x150mm C.I gratig etc. all complete as per aproved drawing, specification and direction of Engineer-in-charge. |
| 206 | Size- 600 x600 mm |
| 207 | Size- 760 x760 mm |
| 208 | Size- 900 x800 mm |
| 209 | Providing and fixing square mouth S.W GULLY TRAP(G T) class SP-1 complete with CI grating brick masonry chamber with water tight CI cover with frame of 300X300mm size (inside),the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per the standard desifn. brick masonry chamber of size 180 X 150 mm size complete as per approved specification and direction of the Engineer in charge |
| 210 | Size- 300x300 mm |
| 211 | Supplying all materials, labour, T & P and constructing of MAN HOLE chamber(M H) of the following inside size with 8 cm thick R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g. chips, foundation concrete (1:4:8) using 40mm size h.g. metal on bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mm x100mm size gully trap, 150mm x150mm C.I gratig etc. all complete as per aproved drawing, specification and direction of Engineer-in-charge. |
| 212 | Man-hole chamber of size 1200x900x900mm |
| 213 | Supplying all materials, labour, T & P and constructing RAINWATER COLLECTION PIT chamber of the following inside size with 8 cm thick R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g. chips, foundation concrete (1:4:8) using 40mm size h.g. metal on bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mm x100mm size gully trap, 150mm x150mm C.I gratig etc. all complete as per aproved drawing, specification and direction of Engineer-in-charge. |
| 214 | 450mmx4500mm with RCC cover |
| 215 | Fixing double layer cylinderical water storage tanks conforming to IS: 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height and placing the tank to the required position etc all complete as per specification and direction of the engineer in charge.DOUBLE LAYER 2000 LIT. CPVC TANK |
| 216 | Supplying, fixing and testing PVC soil, waste, Rain and vent pipes (SWR) SUPREME confirming to IS13592 : 1990, type B with rubber ring/Solvent (confirming toIS5382) joint inclusive of allnecessary specials like bends, tees,offsets, door bends, junctions, cowls, etc.,laid underfloor/ fixed on walls,and in pipe shafts etc., complete.The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. Make:- Supreme/Ashirbad/Astral/Sentini |
| 217 | 40 mm dia . |
| 218 | 50 mm dia . |
| 219 | 75 mm dia . |
| 220 | 110 mm dia . |
| 221 | 110 mm dia Rain pipe. |
| 222 | 160 mm dia. |
| 223 | Supplying, fixing and testing PVC floor trap with SS frame and cover 75mm dia outlet fixed on a bed of cement concrete with (Heavy duty type) etc., complete. |
| 224 | ASTRAL -M252003207 |
| 225 | 40mm x 75 mm dia |
| 226 | Supplying, fixing and testing PVC Nahani trap with SS frame and cover 75mm dia outlet fixed on a bed of cement concrete with (Heavy duty type) etc., complete. |
| 227 | ASTRAL-M252007006 |
| 228 | 75 mm dia |
| 229 | Providing ,fixing , testing and commissioning of approved make PVC vent cowl with necessary accessories etc., complete. |
| 230 | 75 mm dia |
| 231 | 110 mm dia |
| 232 | Providing ,fixing , testing and commissioning of approved make PVC CLEAN OUT PLUG with necessary accessories etc., complete. |
| 233 | 75 mm dia |
| 234 | 110 mm dia |
| 235 | Supplying all materials, labours,T&p and laying trenches (to level or slope) unplasticized P.V.C pipe conforming to IS4985/2016 of the following out side dia for pressure rating PN-6 including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification,providing and laying in trench cement concrete(1:4:8) with 40 mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing e.t.c all complete as per P.H specification and direction of the Engineer in charge |
| 236 | 160 mm dia U-PVC pipe with al-round concreteing |
| 237 | 200 mm dia U-PVC pipe with al-round concreteing |
| 238 | 30 USER SEPTIC TANK |
| 239 | Soak Pit of 1.2 mtr dia and 2.2 mtr depth |
| 240 | ELECTRICAL |
| 241 | Recessed wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6 Amp, 250 V clip in type switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size , with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. (Make of Wires- Finolex/Anchor/Polycab/HAVELLS/RR KABEL/KEI) or equivalent) (Make of Conduit-AKG/Anchor/Polycab or equivalent reputed make A catagory ISI marked as approved) (Make of switch/socket- Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa)/Havells(Equivalent model) or equivalent) (Make of accessories- Anchor/Havells) (Make of G.I box, face plate & cover-Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa) or equivalent reputed make & model A catagory ISI marked as approved) Group C |
| 242 | Recessed wiring to secondary light point looped from primary light point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including 3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer in charge.(Make of Wires- Finolex/Anchor/Polycab/HAVELLS/RR KABEL/KEI) or equivalent) (Make of Conduit-AKG/Anchor/Polycab or equivalent reputed make A catagory ISI marked as approved) (Make of switch/socket- Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa)/Havells(Equivalent model) or equivalent) (Make of accessories- Anchor/Havells) (Make of G.I box, face plate & cover-Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa) or equivalent reputed make & model A catagory ISI marked as approved) Average Length: 3 mtr |
| 243 | Recessed wiring to Twin control light point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6Amp, 250 V clip in type 2way switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size , with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels / V Guard )Group C |
| 244 | Recessed wiring to ceiling fan point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6Amp, 250 V clip in type switch ISI marked and stepped modular Regulator ISI marked mounted on G.I modular box with face plate & cover of suitable size , with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels / V Guard )Group C |
| 245 | Recessed wiring for 5 / 6 amp socket outlet with 6Amp, 250 V clip in type modular switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection on same switch board as per direction of Engineer in Charge. (Make of switch/socket- Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa)/Havells(Equivalent model) or equivalent) |
| 246 | Recessed wiring for 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6Amp, 250 V clip in type switch ISI marked mounted on G.I moular box with face plate & cover of suitable size , with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection on separate board as per direction of Engineer in Charge. (Make of Wires- Finolex/Anchor/Polycab/HAVELLS/RR KABEL/KEI) or equivalent) (Make of Conduit-AKG/Anchor/Polycab or equivalent reputed make A catagory ISI marked as approved) (Make of switch/socket- Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa)/Havells(Equivalent model) or equivalent) (Make of accessories- Anchor/Havells) (Make of G.I box, face plate & cover-Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa) or equivalent reputed make & model A catagory ISI marked as approved) |
| 247 | Recessed wiring for 2 x 6 amp socket outlet controlled by 2 nos 6Amp, 250 V clip in type switch ISI marked mounted on single G.I moular box with face plate & cover of suitable size including all accesories and connection on separate board as per direction of Engineer in Charge. (Make of switch/socket- Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa)/Havells(Equivalent model) or equivalent) |
| 248 | Recessed wiring for 6 pin 16 amp socket outlet with 16Amp, 250 V clip in type switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer in Charge. (Make of switch/socket- Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa) / Havells (Equivalent model) or equivalent) |
| 249 | Recessed wiring for Projector socket outlet with 16A plug socket and 16A control switch at nearest separate location |
| 250 | Supplying and fixing of 25Amp socket & 25Amp, 250 V moular type starter ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer in Charge. |
| 251 | SUBMAIN. |
| 252 | Recessed wiring to submain in 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 25 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 4.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire- Finolex/Anchor/Polycab/ HAVELLS/RR KABEL or equivalent) (Make of conduit-AKG/Anchor/Kinjal or equievalant) |
| 253 | Recessed wiring to submain in 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire- Finolex/Anchor/Polycab/ HAVELLS/RR KABEL or equivalent) (Make of conduit-AKG/Anchor/Kinjal or equievalant) |
| 254 | Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire- Finolex/Anchor/Polycab/ HAVELLS/RR KABEL or equivalent) (Make of conduit-AKG/Anchor/Kinjal or equievalant) |
| 255 | Recessed wiring to submain in 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire- Finolex/Anchor/Polycab/ HAVELLS/RR KABEL or equivalent) (Make of conduit-AKG/Anchor/Kinjal or equievalant) |
| 256 | DISTRIBUTION BOARD . |
| 257 | Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ Isolator) |
| 258 | 4 WAY (4 + 12) TPN DOUBLE DOOR, HORIZONTAL TYPE |
| 259 | Supply and fixing of single pole MCB with sheet steel enclosure, distribution board, on surface /recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, phosphate and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ ISOLATOR) (Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalent model) /ABB(Equivalant model) or equievalant. |
| 260 | 12 way SPN , MCB DB double door |
| 261 | Supply and fixing of following rating 240 V Minature Circuit Breaker (MCB) having a sensitivity current up to 10kA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required. (Make-LEGRAND- DX3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalant model) /ABB(Equivalant model) or equievalant. |
| 262 | 6 amp to 32 amp rating SP MCB , \\"c\\" series, 10KA breaking capacity |
| 263 | Supply and fixing of following rating 240 V Residual Current Breaker with Overcurrent protection (RCBO) having a sensitivity current up to 100mA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required. (Make-LEGRAND- DX3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalant model) /ABB(Equivalant model) or equievalant. |
| 264 | 25 to 40 amp rating DP RCBO, 30mA |
| 265 | 63 amp rating 4P RCBO, 100mA |
| 266 | CABLE . |
| 267 | Supply of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of following sizes of cable as required. (Make- POLYCAB / FINOLEX / HAVELLS) or equievalant reputed ISI MARKED MAKE |
| 268 | 4 C x 16 sq.mm Al |
| 269 | Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface as required. |
| 270 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accesories like socket , bend, couplers etc conforming to IS 14930, part II complete with fitting and cutting jointing etc direct in ground (75mm below ground level) inciuding excavation and refilling the trench but excluding sand cushioning and protective covering etc complete as required. |
| 271 | 120 mm dia (OD -120mm & ID- 103mm nominal) |
| 272 | END TERMINATION |
| 273 | Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required. |
| 274 | 4 C x16sq.mm Al |
| 275 | EARTHING |
| 276 | Supply and fixing of chemical Earthing of with 3mtr long 40mm dia chemical filled comound and GI earth electrode including excavation of earth pit with highly conductive back filled chemical compund of 2 x 25kg , brick work in cement mortar masonary work with removable cover for Earth pit chamber of suitable size including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 277 | Supplying and laying 25 mm x 6 mm G.I earth strip ISI marked at 0.5 meter below grond level as strip earth electrode including soldering etc. as required |
| 278 | Supplying and laying 25 mm x 5 mm copper strip on surface or in recess for connection etc as required. |
| 279 | LIGHTNING ARRESTOR |
| 280 | Providing and fixing of lightning conductor finial made of 25mm dia 300 mm long, G.I tube,having single prong at top,with 85mm dia 6 mm thick G.I base plate including holes etc. complete as required |
| 281 | Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) |
| 282 | Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run) |
| 283 | Providing and fixing of testing joint, made of 20 mm x 3 mm thick G.I. strip, 125 long with 4 nos of G.I. bolts, check nuts and spring washer etc complete as required. |
| 284 | Reveting, sweating and soldering of copper / G.I. tape ( with another copper / G.I. tape, base of the finial or any other metallic object) as required |
| 285 | Providing and laying of G.I. tape 32 mm x 6 mm from earth electrode directly in ground as required. |
| 286 | Earthing with G.I. earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (But wih out charcoal and salt) as required. |
| 287 | Extra for using salt and charcoal for G.I or copper plate earth as required |
| 288 | FIXTURE |
| 289 | Supply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting /LED fitting of all sizes complete with all accessories and lamp etc. directly on ceiling /wall or recessed in false ceiling , including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required. |
| 290 | Surface mounted indoor type 20W SINGLE LED TUBE Luminaire with LED Lamp Similar to WIPRO Cat No. LL20-281-XXX-65AL1/ JAQUAR / Philips / Halonix / Panasonic or equivalent. |
| 291 | Surface/ Recess mounted indoor type 15W ROUND LED Luminaire with LED Lamp Similar to WIPRO Cat No. LD90-191-XXX-65-XX or equivalent. |
| 292 | Surface/Recess mounted indoor type 12W ROUND LED Luminaire with LED Lamp Similar to WIPRO Cat No. LD90-141-XXX-65-XX or equivalent. |
| 293 | Surface mounted indoor type 10W MIRROR LED Luminaire with LED Lamp Similar to WIPRO Cat No. LL20-111-XXX-65NE3 or equivalent. |
| 294 | Supply , fixing & termination of 30watt LED street light fitting complete with cover, GI pipe bracket, necessary wiring from loop-in-box with 3Cx1.5 sqmm copper wires inside PVC pipes etc complete as required with all materials similar to HAVELLS Cat No. LHEXAYP7PN6K030 or equivalent |
| 295 | Supply, Installation, Testing and Commissioning of ceiling fan 1200mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required. |
| 296 | Supply, Installation, testing and commissioning of exhaust fan of 300 mm sweep 900 rpm in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etc as required. |
| 297 | TELEPHONE & DATA |
| 298 | Recessed wiring to telephone point with clip in type modular telephone socket (RJ 11) ISI marked mounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge. |
| 299 | Recessed wiring to LAN point with clip in type modular lan socket (RJ45) ISI marked mounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge. |
| 300 | Supplying and fixing of 25mm PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required. |
| 301 | Supplying and drawing one pair, 0.5 sq.mm FR PVC insulated coper conductor, unarmoured telephone cable in existing surface / recessed PVC conduit as required. |
| 302 | Supplying and drawing UTP 4 pair LAN cat-6 cable in the existing surface / recessed PVC conduit as required.Make :Derwiser, Finolex, Tyco |
| 303 | LAKHANPUR PRIMARY SCHOOL UNDER LEPHERIPARA BLOCK |
| 304 | Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works upto and including 1.5metre depth and stacking the soil upto a lead of 100 metre and including dewatering, removing slush, shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge. |
| 305 | Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth: consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer-In-charge. |
| 306 | Supplying of filling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc., all complete as per the specification and direction of Engineer-In-Charge. |
| 307 | Disposal of surplus excavated materials by mechanical means from the work side etc. complete. upto 5km. Lead |
| 308 | New building |
| 309 | Boundary Wall |
| 310 | Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties and cost of all labours,labour cess, T&P etc complete as per specification & direction of the Engineer-in-charge. |
| 311 | First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge. |
| 312 | Providing and laying in position ready mixed M-25 grade concrete having compressive strength at 28 days test not less than 250 kg/ sq.cm for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and excluding reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, and hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,Labour cess and T&P required for the work improve workability without impairing strength and durability as per direction of the Engineer - in - charge. |
| 313 | Foundation & plinth |
| 314 | Footing |
| 315 | Pedestal |
| 316 | Coloumn from Pedestal top to NGL |
| 317 | Coloumn from NGL to PL |
| 318 | Plinth Beam |
| 319 | Ground floor |
| 320 | Coloumn from PL to Ground floor Roof |
| 321 | Roof beam |
| 322 | Roof slab |
| 323 | Lintle |
| 324 | Staircase |
| 325 | Chajja |
| 326 | Platfrom |
| 327 | R.Dining slab |
| 328 | First floor |
| 329 | Coloumn |
| 330 | Roof beam |
| 331 | Roof slab |
| 332 | Lintel |
| 333 | Staircase |
| 334 | Chajja |
| 335 | Terrace floor |
| 336 | Column |
| 337 | Roof beam |
| 338 | Roof slab |
| 339 | Lintel |
| 340 | BOUNDARY WALL |
| 341 | R.C.C. in footing |
| 342 | RCC in Tie beam |
| 343 | RCC in Pedestal |
| 344 | GROUND FLOOR |
| 345 | RCC in Coloumn |
| 346 | RCC in Band |
| 347 | RCC Roof slab |
| 348 | RCC Roof beam |
| 349 | Pathway |
| 350 | Cutting,straightening coiled or bent up HYSD/TMT 550D Reinforcement Bars confirming to IS 1786:2008 welding or jointing if necessary ,bending, binding,tying the grills as required for R.C.C. works,providing Fan Hooks where necessary and hoising,lowering and placing the same tin proper position according to the approved designs and drawings in all floors including cost, conveyance, loading, unloading and taxes or HYSD/TMT Reinforcement Bars and Binding wieres of 18 to 20 gauge required for the work cost of all labour,T&P and scaffolding complete in all respect as directed by the Engineer-in-charge(Payment will be made according to the actual/proper weight of HYSD/TMT Reinforcement Bars and Binding wires consumed in the particular work only) |
| 351 | New Building |
| 352 | Ground floor |
| 353 | First Floor |
| 354 | Terrace Floor |
| 355 | BOUNDARY WALL |
| 356 | Foundation |
| 357 | Ground Floor |
| 358 | R.Dining ground floor |
| 359 | Fly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12 c.m x 8 c.m in Super structure having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties , all taxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 360 | Ground floor |
| 361 | First Floor |
| 362 | Terrace Floor |
| 363 | BOUNDARY WALL |
| 364 | Fly Ash Brick Masonry in cement mortar of mix (1:4) using Fly Ash bricks of size 25c.m x 12 c.m x 8 c.m in Superstructure having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties ,all taxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 365 | Ground floor |
| 366 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties, with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect and specification and direction of the Engineer in charge. (External wall) |
| 367 | Ground Floor |
| 368 | New Building |
| 369 | First Floor |
| 370 | Terrace floor |
| 371 | BOUNDARY WALL |
| 372 | R.Dining |
| 373 | Ground floor |
| 374 | Providing 16mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary)including watering and curing, rounding of corners etc. complete with cost,conveyance,loading, unloading, royalities and taxes of all materials,cost of all labour,T&P and scaffolding required for the work etc. as directed by the Engineer-in-charge. |
| 375 | Ground Floor |
| 376 | First Floor |
| 377 | Terrace Floor |
| 378 | R.Dining |
| 379 | Ground floor |
| 380 | Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance and royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 381 | Ground Floor |
| 382 | First Floor |
| 383 | R.Dining |
| 384 | Ground floor |
| 385 | Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, all materials, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. |
| 386 | Ground Floor |
| 387 | First Floor |
| 388 | Terrace Floor |
| 389 | R.Dining ground floor |
| 390 | Priming one coat with water bound wall primer. |
| 391 | Ground Floor |
| 392 | First Floor |
| 393 | Terrace Floor |
| 394 | BOUNDARY WALL |
| 395 | R.Dining ground floor |
| 396 | Distempering two coats to walls with distemper of approved shade on new work to give an even shade |
| 397 | Ground Floor |
| 398 | First Floor |
| 399 | Terrace Floor |
| 400 | Wall painting two coats with Weather coat paint (1st quality) exterior grade of approved make & with a approved quality primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge. |
| 401 | Ground Floor |
| 402 | First Floor |
| 403 | Terrace Floor |
| 404 | BOUNDARY WALL |
| 405 | R.Dining ground floor |
| 406 | Providing & painting two coats of Plastic emulsion paint with 1st quality of approved brand and manufacturer to give an even shade as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. |
| 407 | Ground Floor |
| 408 | Supplying,Providing & laying Double charge mat finished vitrified tile flooring using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13755 of 600mmx600mm of premium quality in floors, treads on steps and landings on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the vitrified tile if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. |
| 409 | Ground Floor |
| 410 | First Floor |
| 411 | Supplying, fitting & fixing of Double charged vitrified wall tiles 600mmx600mm in dadoes of approved make laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) and filling joints with slurry including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge. |
| 412 | Ground Floor |
| 413 | First Floor |
| 414 | Supplying, fitting and fixing of Antiskid Ceramic Floor Tiles in flooring using special plain / printed series Ceramic Floor Tile of premium grade ( having minimum thickness 7 mm to 8 mm & size 400 mm x400 mm, confirming to I.S 13755 of approved quality and shade in floors, treads on steps and landings on 20 m.m thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened & washed sharp river sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments (Tiles are to be immersed in the water for required time before use) of approved make to match the shades of the Ceramic Floor Tiles if required including cost, conveyance, loading, unloading, stacking, royalties , all taxes,rubbing, cost of all Labour, Labour cess ,Sundries, T&P required for the work , Watering , Curing for required days , cleaning the flooring space manually etc. complete in all respect as directed by the Engineer-in-charge. |
| 415 | Ground Floor |
| 416 | Supplying, fitting & fixing of 30cm x 20cm/20cm x 20cm special plain/printed series Ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm confirming to IS 13753 laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge. |
| 417 | Ground Floor |
| 418 | Providing Mat finished Granite stone prepolished 20mm thick of area above 0.40 Sqm in flooring of approved quality, colour and size in floors, treads on steps and landings in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the granite tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, Labour cess ,sundries, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. |
| 419 | Ground Floor |
| 420 | First Floor |
| 421 | Terrace Floor |
| 422 | Providing Mat finished Granite stone prepolished 10mm thick of area above 0.40 Sqm in dado/skirting,riser of steps of approved quality, colour and size in dado/ skirting,riser of steps,wall on 12mm thick bed of cement mortar of mix (1:3) laid in proper plumb and line with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the granite tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, Labour cess ,sundries, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. |
| 423 | Ground Floor |
| 424 | First Floor |
| 425 | Terrace Floor |
| 426 | Supplying, fitting & fixing of Industrial vitrified tiles (30x30)cm in floors of approved make laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with slurry including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge |
| 427 | Providing and fixing factory made single extruded 30 mm thick WPC solid decorative type Flush door shutter with both side 1mm thick laminate finish of required size comprising of virgin polymer of K value 58-60calcium carbonate and natural fibers and non-toxic additives having minimum density of 650kg/cum and screw withdrawl strength of 1800N (fACE) & 900N (Edge) minimum compressive strength 50 N / MM2,modulus of elasticity 850N/mm2, and resistance to spread of flame of class A Category with property of being termite/borer proof , water / moisture proof and fire retandant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melted adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screw,SS Handle, Door stopper, SS Hinges, Sliding door bolt etc. all as per direction of EIC. (Make: Century /Floresta/ ALSTONE) |
| 428 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat (Graphite grey colour) comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. ( Frame size 62 x 100 mm) (Make: Century /Floresta/ ALSTONE) |
| 429 | Providing and fixing factory made single extruded 25 mm thick WPC solid decorative type Flush door shutter with paint finish of required size comprising of virgin polymer of K value 58-60calcium carbonate and natural fibers and non-toxic additives having minimum density of 650kg/cum and screw withdrawl strength of 1800N (FACE) & 900N (Edge) minimum compressive strength 50 N / MM2,modulus of elasticity 850N/mm2, and resistance to spread of flame of class A Category with property of being termite/borer proof , water / moisture proof and fire retandant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melted adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screw,SS Handle, Door stopper, SS Hinges, Sliding door bolt etc. all as per direction of EIC. (Make: Century /Floresta/ ALSTONE) |
| 430 | Supplying and Fixing of M.S. Window Grill made out of M.S Flat conforming to IS 2062/2006 excluding the cost of Red Oxide Primer as per the design approve by E.I.C including cost, conveyance of all materials,priming,and labour for fitting fixing etc.complete as per the instruction of Engineer-in-Charge |
| 431 | Painting two coat with approved synthetic enamel paint to new wood & iron work over a coat of primer including cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge. |
| 432 | Ground Floor |
| 433 | First Floor |
| 434 | Terrace Floor |
| 435 | Supplying and Fixing of Elastomeric membrane of 200 x 2mm size for expansion joint sealing from approved manufacturer fixing with epoxy adhesive of approved quality complete |
| 436 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. |
| 437 | Providing and laying approved colour 60 mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with storng vibratory compaction of approved size, design & shape, laid in required colour and pattern over and including 75mm thick sand filling.as per drawing, specification and direction of Engineer-In-charge. |
| 438 | 4 cm thick grading concrete (1:2:4) on roof slab with 12mm & down grade size black hard granite chips for old work. |
| 439 | Ground Floor |
| 440 | Providing and laying grading conc. 25 mm (avg. thickness) cement concrete of required slope of mix 1:2:2 (1cement:2sand:2 graded stone aggregate of 10 mm nominal size) mixed as per manufacturer's specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge prior to material procurement by the contractor. |
| 441 | Sunken treatment |
| 442 | Stage 1: Cleaning of concrete surface to remove dust oil |
| 443 | Making plinth protection 50mm thick of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well ramed, consolidated and grouted with fine sand and finishing the top smooth including shuttering at the edges, excavation and disposing of surplus earth with a lead of 100m complete as per direction of Engineer-in-charge. |
| 444 | Main building |
| 445 | DISMANTLING & DISPOSAL. |
| 446 | Dismantling of brick or stone masonary in lime or cement mortar above 3 mtr height including stacking the useful materials for reuse & removing the debries within 50 mtr. |
| 447 | Dismantling and removing R.C.C coloumns beams slab staircase landing lintels including stacking the useful materials for reuse and removing the derbris within 50m leads |
| 448 | BORE WELL |
| 449 | Construction of 1 nos production wells including scientific source finding through consolidated and unconsolidated rock with down the hamer drilling rig or combination rig with pvc pipe and installation of submersible pump set with all acessories |
| 450 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the engineer in charge including use of own rig with its accessories ,tools and plant and consumables etc for lowering of 200mm/150mm dia G.I.P.V C/M.S casing pipes for housing fitted with socket and with or without well screen as for the necessity for soft ,medium,hard and boulder formation( G.I/P.V.C/M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well) 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only |
| 451 | Drilling of 200mm dia bore (1 nos ) |
| 452 | 00mtr to 60mtr |
| 453 | Drilling of 150mm dia bore |
| 454 | 61mtr to 120mtr (2 nos ) |
| 455 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity form ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and dotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials |
| 456 | Lowering of 200mm dia P V C casing pipes |
| 457 | 00mtr to 60mtr |
| 458 | Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 PART-II specification length of pipe (laying length) will be 3 mtrs.The pipes shall be supplied with both external threaded with free socket. The pipe having external thread at one end i.e. female & or belled end . The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber 'O' ring to make the joint water tight color of the pipe shall be blue The name of the manufacture along with batch.No class of pipe shall be stranded legibly of each pipe length |
| 459 | 200mm dia PVC (sch-80) pipe (As Per SoR -2022) |
| 460 | Supplying all materials, labour, T & P and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all com |
| 461 | Cleaning & developing the tube well with supply of compressor worked till clear & adequqte discharge is obtained from the tube well including supply & use of all necessary equipment & labour as per directin of the Engineer in charge |
| 462 | By DTH Rig |
| 463 | Supplying all materials, equipments,labour & conducting reconnaissance survey , integrated Hydrological & Geophysical (Electrical resistivity Method) survey & selection of potential source for exploration of ground water including selection & recommend |
| 464 | Rocky terrain with boulder formation for 300m depth |
| 465 | Supplying all materials, labours, T&P and providing fitting & fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase /1 phase line voltage ranging from 320 volt to 450 volt conforming to Si 8034/89 with following specifications with suitable control panel ,jointing with GI/PVC/HDPE pipes,electrification,testing, commissioning ,trial running, conveyance of all materials to worksite , payment of taxex etc all complete as per specification & direction of the Engineer in charge (Texmo/crompton Greaves/ Kirloskar make) |
| 466 | 2HP Single phase 3 stage vertical/Horizontal submersible pump set at head renge of 30 to 54 mtr with discharge capacity 155 to 110 L P.M with outlet dia 32mm |
| 467 | Dol Control panel |
| 468 | 40mm dia steel short piece |
| 469 | Well cap |
| 470 | 50mm size CI bracket |
| 471 | 25 sqmm flat cable |
| 472 | 20 mm dia rigid UPVC pipes |
| 473 | Steel ropes with cover |
| 474 | Labour charges for lowering including transportation |
| 475 | Supplying all materials ,labour, T&P and providing and fixing to wall or celling and floor HDPE pipes and pipe fiting conforming to IS: 4984/2000(10KGF/SQCM) of the following nominal bore with clamps & joining by Fusion welding method including testing making good the wall celling & floor all complete as per specificaations 7 direction of the engineer in charge |
| 476 | 32mm dia HDPE pipe |
| 477 | Borewell Chamber |
| 478 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the engineer-in-charge.1.20x1.20x0.40= |
| 479 | Supplying all matrials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all complete as per direction of the engineer in charge. |
| 480 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering , curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the engineer in charge. In ground floor 1.20x1.2x0.15= |
| 481 | Supplying all matrials, labour, T&P and providing brick work with fly ash brick having crushing strength not less than 75kg/cm2 with dimensional tolerance 8 percent in cement mortar (1:6) including watering , curing, conveyance of all materials to worksite, payment of royalty, taxec etc all complete as per specification and direction of the engineer incharge. In F&P 2(1.15+0.65)X1.00X0.25= |
| 482 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and trying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the engineer in charge. In ground floor. |
| 483 | R.C.C. M-25 grade with 20mm and down grade C.B. chips of approved quality from approved quarry including hoisting, laying hire charges of concrete mixture, vibrator, watering, curing and cost of all materials and labour, centering shuttering etc complete but excluding cost of reinforcement. In ground floor. |
| 484 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard brocken granite chips including watering, curing , conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the engineer in charge. In ground floor. |
| 485 | Supplying all maerials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering , curing, conveyance of all materials to worksite, payment of royalty, taxes etc all materials to worksite,payment of royalty, taxes etc all complete as per specification and direction of the engineer in charge. In ground floor (inside/outside) |
| 486 | INTERNAL P.H. & SANITARY WORK. |
| 487 | WATER SUPPLY. |
| 488 | Supplying, installing, fixing, jointing, testing and commissioning of approved make. Chlorinated Polyvinyl Chloride pipes (CPVC) SDR.11 pipes confirming to ASTM standards with necessary fittings for inetrnal toilet water supply upto 50 dia , and above 50mm dia pipe schedule 40 with fitting shall be schedule 80 ASTM IPS. The fittings and specials such as tees, elbows,couplers, bends, enlargers etc.,m with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement martor 1:1 restore the same original condition neately as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846 and above 50mm dia primer P-70, and solvent confirming to ASTM F-4931 / 724 All exposed pipe shall be painted with latex paint. (for shafts, basement ceiling ringmain Terrace & PRM).The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. Make:- Supreme/Ashirbad/AKG. |
| 489 | 20 mm dia C-PVC pipe (Oriplast/Supreme) |
| 490 | 25 mm dia C-PVC pipe (Oriplast/Supreme) |
| 491 | 40 mm dia C-PVC pipe (Oriplast/Supreme) |
| 492 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings etc. all complete as per P.H. specification and direction of Engineer-in-charge. 250 mm thick wall |
| 493 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages as per direction of the E.I.C. |
| 494 | Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of the Engineer-in-charge. |
| 495 | SANITARY FIXTURES. |
| 496 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Water Closet & cistern fitting (European type W.C. pan) of Hindware/Jaquar/Parryware with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer-In-Charge. |
| 497 | Supplying all materials, labour, T&P and fixing Health Faucet of Hindware/Jaquar/Parryware complete with Chromium plated brass brackets fixed to wooden plugs with Chromium plated brass screws as per specification and direction of the Engineer-In-Charge. |
| 498 | Supplying all materials, labour, T&P and fixing standard sized two way Bib cock of Hindware/Jaquar/Parryware of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. 15mm dia CP Two way bib cock with Flange. |
| 499 | Supplying all materials, labour T&P and fixing of Under Counter wash basins with bottle trap & cp fittings of Hindware/Jaquar/Parryware of approved make in all floor of approved quality including cutting the walls & floor and making good the damags with cement concrete e.t.c including all tsxes,duties,transportation e.t.c. All complete as per specification and direction of the Engineer-In-Charge.(Size: 560x430x195 mm) |
| 500 | Supplying all materials, labour, T&P and fixing standard sized pillar cock of of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 15mm dia brass pillar cock.(MAKE -JAQUAR) |
| 501 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C.sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer-in-charge. Swivel Mirror Rectangular Shape(630x450) |
| 502 | Supplying all materials, labour, T&P and fixing standard sized Chromium Plated Glass Shelf of Hindware/Jaquar/Parryware complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge. |
| 503 | Supplying, installing, testing and commissioning of approved make White Viterous urinals 3.8 LPM supported by CI/MS bracket duly painted, including CP brass waste with dome type grating, CP cast brass bottle trap with extension piece, wall flanges, automatic flushing systems for urinal to ensure flusing only immediately after use, comprising of all plumbing, electronic and electrical items. CP brass flush pipe with CP brass elbow, CP brass spreader, CP wall flange, infrared photo cells (Sensor), eyes electrically operated solenoid valve, gate valve, black box and necessary wiring in conduit from solenoid value to black box and to mains etc, complete. Including necessary wall cutting/chasing and making good, as required. , jaquar,Size:385x325x635mm,jaquar-URS-WHT-13253N |
| 504 | Supplying all materials, labour T&P and fixing URINAL FLUSH VALVE FLV-1095NG (Make: Jaquar) of approved make etc complete including cost of all materials complete as per PH specification and direction of Engineering-in-charge |
| 505 | Providing & Fixing granite slab with Table rubbed, edges rounded and polished of size 75x50 cm deep and 18mm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 as per direction of Er-in-charge. |
| 506 | Supplying all materials, labour, T&P and fixing standard sized Robe Hook of Hindware/Jaquar/Parryware complete with all as per specification and direction of the Engineer in charge. |
| 507 | Supplying all materials, labour, T&P and fixing standard sized 15mm dia angular Stop cock of Hindware/Jaquar/Parryware of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. |
| 508 | Supplying all materials, labour, T&P and fixing standard sized Chromium Plated soap case Hindware/Jaquar/Parryware complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge. |
| 509 | Supplying all materials, labour, T&P and fixing standard sized Chromium Plated brass towel ring of Hindware/Jaquar/Parryware complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge. |
| 510 | Supplying all materials, labour, T&P and fixing standard sized Chromium Plated brass towel rail of Hindware/Jaquar/Parryware complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge. |
| 511 | Supplying all materials, labour, T&P and fixing standard sized Chromium Plated Paper Holder of Hindware/Jaquar/Parryware complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge.jaquar CAN-1153S |
| 512 | Fixing of 32 mm dia Brass/GM Fulway Valve confirming to IS : 781-1995 of approved make as per specification complete as per direction of Er-in-charge. 32mm dia brass or gun metal full way valve.(Make- zoloto or equivalent.) |
| 513 | Fixing of 20 dia Brass/GM Fulway Valve confirming to IS : 781-1995 of approved make as per specification complete as per direction of Er-in-charge. 20mm dia brass or gun metal full way valve.(Make- zoloto or equivalent.) |
| 514 | EXTERNAL P.H.E & SEWAGE SYSTEM. |
| 515 | Supplying all materials, labour, T & P and constructing of Inspection chamber(IC) of the following inside size with 8 cm thick R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g. chips, foundation concrete (1:4:8) using 40mm size h.g. metal on bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mm x100mm size gully trap, 150mm x150mm C.I gratig etc. all complete as per aproved drawing, specification and direction of Engineer-in-charge. |
| 516 | Size- 600 x600 mm |
| 517 | Size- 760 x760 mm |
| 518 | Size- 900 x800 mm |
| 519 | Providing and fixing square mouth S.W GULLY TRAP(G T) class SP-1 complete with CI grating brick masonry chamber with water tight CI cover with frame of 300X300mm size (inside),the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per the standard desifn. brick masonry chamber of size 180 X 150 mm size complete as per approved specification and direction of the Engineer in charge |
| 520 | Size- 300x300 mm |
| 521 | Supplying all materials, labour, T & P and constructing of MAN HOLE chamber(M H) of the following inside size with 8 cm thick R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g. chips, foundation concrete (1:4:8) using 40mm size h.g. metal on bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mm x100mm size gully trap, 150mm x150mm C.I gratig etc. all complete as per aproved drawing, specification and direction of Engineer-in-charge. |
| 522 | Man-hole chamber of size 1200x900x900mm |
| 523 | Supplying all materials, labour, T & P and constructing RAINWATER COLLECTION PIT chamber of the following inside size with 8 cm thick R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g. chips, foundation concrete (1:4:8) using 40mm size h.g. metal on bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mm x100mm size gully trap, 150mm x150mm C.I gratig etc. all complete as per aproved drawing, specification and direction of Engineer-in-charge. |
| 524 | 450mmx4500mm with RCC cover |
| 525 | Fixing double layer cylinderical water storage tanks conforming to IS: 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height and placing the tank to the required position etc all complete as per specification and direction of the engineer in charge.DOUBLE LAYER 2000 LIT. CPVC TANK |
| 526 | Supplying, fixing and testing PVC soil, waste, Rain and vent pipes (SWR) SUPREME confirming to IS13592 : 1990, type B with rubber ring/Solvent (confirming toIS5382) joint inclusive of allnecessary specials like bends, tees,offsets, door bends, junctions, cowls, etc.,laid underfloor/ fixed on walls,and in pipe shafts etc., complete.The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. Make:- Supreme/Ashirbad/Astral/Sentini |
| 527 | 40 mm dia . |
| 528 | 50 mm dia . |
| 529 | 75 mm dia . |
| 530 | 110 mm dia . |
| 531 | 110 mm dia Rain pipe. |
| 532 | 160 mm dia. |
| 533 | Supplying, fixing and testing PVC floor trap with SS frame and cover 75mm dia outlet fixed on a bed of cement concrete with (Heavy duty type) etc., complete. |
| 534 | ASTRAL -M252003207 |
| 535 | 40mm x 75 mm dia |
| 536 | Supplying, fixing and testing PVC Nahani trap with SS frame and cover 75mm dia outlet fixed on a bed of cement concrete with (Heavy duty type) etc., complete. |
| 537 | ASTRAL-M252007006 |
| 538 | 75 mm dia |
| 539 | Providing ,fixing , testing and commissioning of approved make PVC vent cowl with necessary accessories etc., complete. |
| 540 | 75 mm dia |
| 541 | 110 mm dia |
| 542 | Providing ,fixing , testing and commissioning of approved make PVC CLEAN OUT PLUG with necessary accessories etc., complete. |
| 543 | 75 mm dia |
| 544 | 110 mm dia |
| 545 | Supplying all materials, labours,T&p and laying trenches (to level or slope) unplasticized P.V.C pipe conforming to IS4985/2016 of the following out side dia for pressure rating PN-6 including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification,providing and laying in trench cement concrete(1:4:8) with 40 mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing e.t.c all complete as per P.H specification and direction of the Engineer in charge |
| 546 | 160 mm dia U-PVC pipe with al-round concreteing |
| 547 | 200 mm dia U-PVC pipe with al-round concreteing |
| 548 | 30 USER SEPTIC TANK |
| 549 | Soak Pit of 1.2 mtr dia and 2.2 mtr depth |
| 550 | ELECTRICAL |
| 551 | Recessed wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6 Amp, 250 V clip in type switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size , with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. (Make of Wires- Finolex/Anchor/Polycab/HAVELLS/RR KABEL/KEI) or equivalent) (Make of Conduit-AKG/Anchor/Polycab or equivalent reputed make A catagory ISI marked as approved) (Make of switch/socket- Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa)/Havells(Equivalent model) or equivalent) (Make of accessories- Anchor/Havells) (Make of G.I box, face plate & cover-Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa) or equivalent reputed make & model A catagory ISI marked as approved) Group C |
| 552 | Recessed wiring to secondary light point looped from primary light point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including 3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer in charge.(Make of Wires- Finolex/Anchor/Polycab/HAVELLS/RR KABEL/KEI) or equivalent) (Make of Conduit-AKG/Anchor/Polycab or equivalent reputed make A catagory ISI marked as approved) (Make of switch/socket- Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa)/Havells(Equivalent model) or equivalent) (Make of accessories- Anchor/Havells) (Make of G.I box, face plate & cover-Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa) or equivalent reputed make & model A catagory ISI marked as approved) Average Length: 3 mtr |
| 553 | Recessed wiring to Twin control light point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6Amp, 250 V clip in type 2way switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size , with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels / V Guard )Group C |
| 554 | Recessed wiring to ceiling fan point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6Amp, 250 V clip in type switch ISI marked and stepped modular Regulator ISI marked mounted on G.I modular box with face plate & cover of suitable size , with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels / V Guard )Group C |
| 555 | Recessed wiring for 5 / 6 amp socket outlet with 6Amp, 250 V clip in type modular switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection on same switch board as per direction of Engineer in Charge. (Make of switch/socket- Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa)/Havells(Equivalent model) or equivalent) |
| 556 | Recessed wiring for 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6Amp, 250 V clip in type switch ISI marked mounted on G.I moular box with face plate & cover of suitable size , with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection on separate board as per direction of Engineer in Charge. (Make of Wires- Finolex/Anchor/Polycab/HAVELLS/RR KABEL/KEI) or equivalent) (Make of Conduit-AKG/Anchor/Polycab or equivalent reputed make A catagory ISI marked as approved) (Make of switch/socket- Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa)/Havells(Equivalent model) or equivalent) (Make of accessories- Anchor/Havells) (Make of G.I box, face plate & cover-Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa) or equivalent reputed make & model A catagory ISI marked as approved) |
| 557 | Recessed wiring for 2 x 6 amp socket outlet controlled by 2 nos 6Amp, 250 V clip in type switch ISI marked mounted on single G.I moular box with face plate & cover of suitable size including all accesories and connection on separate board as per direction of Engineer in Charge. (Make of switch/socket- Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa)/Havells(Equivalent model) or equivalent) |
| 558 | Recessed wiring for 6 pin 16 amp socket outlet with 16Amp, 250 V clip in type switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer in Charge. (Make of switch/socket- Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa) / Havells (Equivalent model) or equivalent) |
| 559 | Recessed wiring for Projector socket outlet with 16A plug socket and 16A control switch at nearest separate location |
| 560 | Supplying and fixing of 25Amp socket & 25Amp, 250 V moular type starter ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer in Charge. |
| 561 | SUBMAIN. |
| 562 | Recessed wiring to submain in 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 25 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 4.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire- Finolex/Anchor/Polycab/ HAVELLS/RR KABEL or equivalent) (Make of conduit-AKG/Anchor/Kinjal or equievalant) |
| 563 | Recessed wiring to submain in 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire- Finolex/Anchor/Polycab/ HAVELLS/RR KABEL or equivalent) (Make of conduit-AKG/Anchor/Kinjal or equievalant) |
| 564 | Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire- Finolex/Anchor/Polycab/ HAVELLS/RR KABEL or equivalent) (Make of conduit-AKG/Anchor/Kinjal or equievalant) |
| 565 | Recessed wiring to submain in 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire- Finolex/Anchor/Polycab/ HAVELLS/RR KABEL or equivalent) (Make of conduit-AKG/Anchor/Kinjal or equievalant) |
| 566 | DISTRIBUTION BOARD . |
| 567 | Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ Isolator) |
| 568 | 4 WAY (4 + 12) TPN DOUBLE DOOR, HORIZONTAL TYPE |
| 569 | Supply and fixing of single pole MCB with sheet steel enclosure, distribution board, on surface /recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, phosphate and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ ISOLATOR) (Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalent model) /ABB(Equivalant model) or equievalant. |
| 570 | 12 way SPN , MCB DB double door |
| 571 | Supply and fixing of following rating 240 V Minature Circuit Breaker (MCB) having a sensitivity current up to 10kA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required. (Make-LEGRAND- DX3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalant model) /ABB(Equivalant model) or equievalant. |
| 572 | 6 amp to 32 amp rating SP MCB , \\"c\\" series, 10KA breaking capacity |
| 573 | Supply and fixing of following rating 240 V Residual Current Breaker with Overcurrent protection (RCBO) having a sensitivity current up to 100mA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required. (Make-LEGRAND- DX3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalant model) /ABB(Equivalant model) or equievalant. |
| 574 | 25 to 40 amp rating DP RCBO, 30mA |
| 575 | 63 amp rating 4P RCBO, 100mA |
| 576 | CABLE . |
| 577 | Supply of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of following sizes of cable as required. (Make- POLYCAB / FINOLEX / HAVELLS) or equievalant reputed ISI MARKED MAKE |
| 578 | 4 C x 16 sq.mm Al |
| 579 | Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface as required. |
| 580 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accesories like socket , bend, couplers etc conforming to IS 14930, part II complete with fitting and cutting jointing etc direct in ground (75mm below ground level) inciuding excavation and refilling the trench but excluding sand cushioning and protective covering etc complete as required. |
| 581 | 120 mm dia (OD -120mm & ID- 103mm nominal) |
| 582 | END TERMINATION |
| 583 | Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required. |
| 584 | 4 C x16sq.mm Al |
| 585 | EARTHING |
| 586 | Supply and fixing of chemical Earthing of with 3mtr long 40mm dia chemical filled comound and GI earth electrode including excavation of earth pit with highly conductive back filled chemical compund of 2 x 25kg , brick work in cement mortar masonary work with removable cover for Earth pit chamber of suitable size including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 587 | Supplying and laying 25 mm x 6 mm G.I earth strip ISI marked at 0.5 meter below grond level as strip earth electrode including soldering etc. as required |
| 588 | Supplying and laying 25 mm x 5 mm copper strip on surface or in recess for connection etc as required. |
| 589 | LIGHTNING ARRESTOR |
| 590 | Providing and fixing of lightning conductor finial made of 25mm dia 300 mm long, G.I tube,having single prong at top,with 85mm dia 6 mm thick G.I base plate including holes etc. complete as required |
| 591 | Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) |
| 592 | Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run) |
| 593 | Providing and fixing of testing joint, made of 20 mm x 3 mm thick G.I. strip, 125 long with 4 nos of G.I. bolts, check nuts and spring washer etc complete as required. |
| 594 | Reveting, sweating and soldering of copper / G.I. tape ( with another copper / G.I. tape, base of the finial or any other metallic object) as required |
| 595 | Providing and laying of G.I. tape 32 mm x 6 mm from earth electrode directly in ground as required. |
| 596 | Earthing with G.I. earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (But wih out charcoal and salt) as required. |
| 597 | Extra for using salt and charcoal for G.I or copper plate earth as required |
| 598 | FIXTURE |
| 599 | Supply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting /LED fitting of all sizes complete with all accessories and lamp etc. directly on ceiling /wall or recessed in false ceiling , including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required. |
| 600 | Surface mounted indoor type 20W SINGLE LED TUBE Luminaire with LED Lamp Similar to WIPRO Cat No. LL20-281-XXX-65AL1/ JAQUAR / Philips / Halonix / Panasonic or equivalent. |
| 601 | Surface/ Recess mounted indoor type 15W ROUND LED Luminaire with LED Lamp Similar to WIPRO Cat No. LD90-191-XXX-65-XX or equivalent. |
| 602 | Surface/Recess mounted indoor type 12W ROUND LED Luminaire with LED Lamp Similar to WIPRO Cat No. LD90-141-XXX-65-XX or equivalent. |
| 603 | Surface mounted indoor type 10W MIRROR LED Luminaire with LED Lamp Similar to WIPRO Cat No. LL20-111-XXX-65NE3 or equivalent. |
| 604 | Supply , fixing & termination of 30watt LED street light fitting complete with cover, GI pipe bracket, necessary wiring from loop-in-box with 3Cx1.5 sqmm copper wires inside PVC pipes etc complete as required with all materials similar to HAVELLS Cat No. LHEXAYP7PN6K030 or equivalent |
| 605 | Supply, Installation, Testing and Commissioning of ceiling fan 1200mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required. |
| 606 | Supply, Installation, testing and commissioning of exhaust fan of 300 mm sweep 900 rpm in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etc as required. |
| 607 | TELEPHONE & DATA |
| 608 | Recessed wiring to LAN point with clip in type modular lan socket (RJ45) ISI marked mounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge. |
| 609 | Recessed wiring to LAN point with clip in type modular lan socket (RJ45) ISI marked mounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge. |
| 610 | Supplying and fixing of 25mm PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required. |
| 611 | Supplying and drawing one pair, 0.5 sq.mm FR PVC insulated coper conductor, unarmoured telephone cable in existing surface / recessed PVC conduit as required. |
| 612 | Supplying and drawing UTP 4 pair LAN cat-6 cable in the existing surface / recessed PVC conduit as required.Make :Derwiser, Finolex, Tyco |
| 613 | GOVT UPS BAIRAGIBAHAL UNDER LEPHERIPARA BLOCK |
| 614 | Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works upto and including 1.5metre depth and stacking the soil upto a lead of 100 metre and including dewatering, removing slush, shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge. |
| 615 | Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth: consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer-In-charge. |
| 616 | Boundary Wall back filling available excavated earth ( excluding rock) in trench, plinth, sides of foundation etc. |
| 617 | Supplying of filling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc., all complete as per the specification and direction of Engineer-In-Charge. |
| 618 | Disposal of surplus excavated materials by mechanical means from the work side etc. complete. upto 5km. Lead |
| 619 | New building |
| 620 | Boundary Wall |
| 621 | Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties and cost of all labours,labour cess, T&P etc complete as per specification & direction of the Engineer-in-charge. |
| 622 | First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge. |
| 623 | Providing and laying in position ready mixed M-25 grade concrete having compressive strength at 28 days test not less than 250 kg/ sq.cm for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and excluding reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, and hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,Labour cess and T&P required for the work improve workability without impairing strength and durability as per direction of the Engineer - in - charge. |
| 624 | Foundation & plinth |
| 625 | Footing |
| 626 | Pedestal |
| 627 | Coloumn from Pedestal top to NGL |
| 628 | Coloumn from NGL to PL |
| 629 | Plinth Beam |
| 630 | Ground floor |
| 631 | Coloumn from PL to Ground floor Roof |
| 632 | Roof beam |
| 633 | Roof slab |
| 634 | Lintle |
| 635 | Staircase |
| 636 | Chajja |
| 637 | Platfrom |
| 638 | R.Dining slab |
| 639 | First floor |
| 640 | Coloumn |
| 641 | Roof beam |
| 642 | Roof slab |
| 643 | Lintel |
| 644 | Staircase |
| 645 | Chajja |
| 646 | Terrace floor |
| 647 | Column |
| 648 | Roof beam |
| 649 | Roof slab |
| 650 | Lintel |
| 651 | BOUNDARY WALL |
| 652 | R.C.C. in footing |
| 653 | RCC in Tie beam |
| 654 | RCC in Pedestal |
| 655 | GROUND FLOOR |
| 656 | RCC in Coloumn |
| 657 | RCC in Band |
| 658 | RCC Roof slab |
| 659 | RCC Roof beam |
| 660 | Pathway |
| 661 | Cutting,straightening coiled or bent up HYSD/TMT 550D Reinforcement Bars confirming to IS 1786:2008 welding or jointing if necessary ,bending, binding,tying the grills as required for R.C.C. works,providing Fan Hooks where necessary and hoising,lowering and placing the same tin proper position according to the approved designs and drawings in all floors including cost, conveyance, loading, unloading and taxes or HYSD/TMT Reinforcement Bars and Binding wieres of 18 to 20 gauge required for the work cost of all labour,T&P and scaffolding complete in all respect as directed by the Engineer-in-charge(Payment will be made according to the actual/proper weight of HYSD/TMT Reinforcement Bars and Binding wires consumed in the particular work only) |
| 662 | New Building (New STBH) |
| 663 | Ground floor |
| 664 | First Floor |
| 665 | Terrace Floor |
| 666 | BOUNDARY WALL |
| 667 | Foundation |
| 668 | Ground Floor |
| 669 | R.Dining ground floor |
| 670 | Fly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12 c.m x 8 c.m in Super structure having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties , all taxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 671 | Ground floor |
| 672 | First Floor |
| 673 | Terrace Floor |
| 674 | BOUNDARY WALL |
| 675 | Fly Ash Brick Masonry in cement mortar of mix (1:4) using Fly Ash bricks of size 25c.m x 12 c.m x 8 c.m in Superstructure having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties ,all taxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 676 | Ground floor |
| 677 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties, with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect and specification and direction of the Engineer in charge. (External wall) |
| 678 | Ground Floor |
| 679 | New Building (New STBH) |
| 680 | First Floor |
| 681 | Terrace floor |
| 682 | BOUNDARY WALL |
| 683 | R.Dining |
| 684 | Ground floor |
| 685 | Terrace Floor |
| 686 | Providing 16mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary)including watering and curing, rounding of corners etc. complete with cost,conveyance,loading, unloading, royalities and taxes of all materials,cost of all labour,T&P and scaffolding required for the work etc. as directed by the Engineer-in-charge. |
| 687 | Ground Floor |
| 688 | First Floor |
| 689 | Terrace Floor |
| 690 | R.Dining |
| 691 | Ground floor |
| 692 | Terrace Floor |
| 693 | Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance and royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 694 | Ground Floor |
| 695 | First Floor |
| 696 | R.Dining |
| 697 | Ground floor |
| 698 | Terrace Floor |
| 699 | Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, all materials, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. |
| 700 | Ground Floor |
| 701 | First Floor |
| 702 | Terrace Floor |
| 703 | R.Dining ground floor |
| 704 | R.Dining Terrace floor |
| 705 | Priming one coat with water bound wall primer. |
| 706 | Ground Floor |
| 707 | First Floor |
| 708 | Terrace Floor |
| 709 | BOUNDARY WALL |
| 710 | R.Dining ground floor |
| 711 | R.Dining Terrace floor |
| 712 | Distempering two coats to walls with distemper of approved shade on new work to give an even shade |
| 713 | Ground Floor |
| 714 | First Floor |
| 715 | Terrace Floor |
| 716 | Wall painting two coats with Weather coat paint (1st quality) exterior grade of approved make & with a approved quality primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge. |
| 717 | Ground Floor |
| 718 | First Floor |
| 719 | Terrace Floor |
| 720 | BOUNDARY WALL |
| 721 | R.Dining ground floor |
| 722 | R.Dining Terrace floor |
| 723 | Providing & painting two coats of Plastic emulsion paint with 1st quality of approved brand and manufacturer to give an even shade as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. |
| 724 | Ground Floor |
| 725 | First Floor |
| 726 | Supplying,Providing & laying Double charge mat finished vitrified tile flooring using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13755 of 600mmx600mm of premium quality in floors, treads on steps and landings on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the vitrified tile if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. |
| 727 | Ground Floor |
| 728 | First Floor |
| 729 | Supplying, fitting & fixing of Double charged vitrified wall tiles 600mmx600mm in dadoes of approved make laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) and filling joints with slurry including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge. |
| 730 | Ground Floor |
| 731 | First Floor |
| 732 | Supplying, fitting and fixing of Antiskid Ceramic Floor Tiles in flooring using special plain / printed series Ceramic Floor Tile of premium grade ( having minimum thickness 7 mm to 8 mm & size 400 mm x400 mm, confirming to I.S 13755 of approved quality and shade in floors, treads on steps and landings on 20 m.m thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened & washed sharp river sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments (Tiles are to be immersed in the water for required time before use) of approved make to match the shades of the Ceramic Floor Tiles if required including cost, conveyance, loading, unloading, stacking, royalties , all taxes,rubbing, cost of all Labour, Labour cess ,Sundries, T&P required for the work , Watering , Curing for required days , cleaning the flooring space manually etc. complete in all respect as directed by the Engineer-in-charge. |
| 733 | Ground Floor |
| 734 | Supplying, fitting & fixing of 30cm x 20cm/20cm x 20cm special plain/printed series Ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm confirming to IS 13753 laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge. |
| 735 | Ground Floor |
| 736 | Providing Mat finished Granite stone prepolished 20mm thick of area above 0.40 Sqm in flooring of approved quality, colour and size in floors, treads on steps and landings in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the granite tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, Labour cess ,sundries, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. |
| 737 | Ground Floor |
| 738 | First Floor |
| 739 | Terrace Floor |
| 740 | Providing Mat finished Granite stone prepolished 10mm thick of area above 0.40 Sqm in dado/skirting,riser of steps of approved quality, colour and size in dado/ skirting,riser of steps,wall on 12mm thick bed of cement mortar of mix (1:3) laid in proper plumb and line with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the granite tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, Labour cess ,sundries, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. |
| 741 | Ground Floor |
| 742 | First Floor |
| 743 | Terrace Floor |
| 744 | Supplying, fitting & fixing of Industrial vitrified tiles (30x30)cm in floors of approved make laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with slurry including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge |
| 745 | Providing and fixing factory made single extruded 30 mm thick WPC solid decorative type Flush door shutter with both side 1mm thick laminate finish of required size comprising of virgin polymer of K value 58-60calcium carbonate and natural fibers and non-toxic additives having minimum density of 650kg/cum and screw withdrawl strength of 1800N (fACE) & 900N (Edge) minimum compressive strength 50 N / MM2,modulus of elasticity 850N/mm2, and resistance to spread of flame of class A Category with property of being termite/borer proof , water / moisture proof and fire retandant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melted adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screw,SS Handle, Door stopper, SS Hinges, Sliding door bolt etc. all as per direction of EIC. (Make: Century /Floresta/ ALSTONE) |
| 746 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat (Graphite grey colour) comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. ( Frame size 62 x 100 mm) (Make: Century /Floresta/ ALSTONE) |
| 747 | Providing and fixing factory made single extruded 25 mm thick WPC solid decorative type Flush door shutter with paint finish of required size comprising of virgin polymer of K value 58-60calcium carbonate and natural fibers and non-toxic additives having minimum density of 650kg/cum and screw withdrawl strength of 1800N (FACE) & 900N (Edge) minimum compressive strength 50 N / MM2,modulus of elasticity 850N/mm2, and resistance to spread of flame of class A Category with property of being termite/borer proof , water / moisture proof and fire retandant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melted adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screw,SS Handle, Door stopper, SS Hinges, Sliding door bolt etc. all as per direction of EIC. (Make: Century /Floresta/ ALSTONE) |
| 748 | Supplying and Fixing of M.S. Window Grill made out of M.S Flat conforming to IS 2062/2006 excluding the cost of Red Oxide Primer as per the design approve by E.I.C including cost, conveyance of all materials,priming,and labour for fitting fixing etc.complete as per the instruction of Engineer-in-Charge |
| 749 | Painting two coat with approved synthetic enamel paint to new wood & iron work over a coat of primer including cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge. |
| 750 | Ground Floor |
| 751 | First Floor |
| 752 | Terrace Floor |
| 753 | Supplying and Fixing of Elastomeric membrane of 200 x 2mm size for expansion joint sealing from approved manufacturer fixing with epoxy adhesive of approved quality complete |
| 754 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. |
| 755 | Providing and laying grading conc. 25mm (avg. thickness) cement concrete of required slope of ix 1:2:2 mixed as per manufacturer's specification on top of the slab includimg cement slurry |
| 756 | Providing and laying approved colour 60 mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with storng vibratory compaction of approved size, design & shape, laid in required colour and pattern over and including 75mm thick sand filling.as per drawing, specification and direction of Engineer-In-charge. |
| 757 | 4 cm thick grading concrete (1:2:4) on roof slab with 12mm & down grade size black hard granite chips for old work. |
| 758 | Ground Floor |
| 759 | Terrace Floor |
| 760 | Sunken treatment |
| 761 | Stage 1: Cleaning of concrete surface to remove dust oil |
| 762 | Making plinth protection 50mm thick of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well ramed, consolidated and grouted with fine sand and finishing the top smooth including shuttering at the edges, excavation and disposing of surplus earth with a lead of 100m complete as per direction of Engineer-in-charge. |
| 763 | DISMANTLING & DISPOSAL. |
| 764 | Dismantling of brick or stone masonary in lime or cement mortar above 3 mtr height including stacking the useful materials for reuse & removing the debries within 50 mtr. |
| 765 | Dismantling and removing R.C.C coloumns beams slab staircase landing lintels including stacking the useful materials for reuse and removing the derbris within 50m leads |
| 766 | BORE WELL |
| 767 | Construction of 1 nos production wells including scientific source finding through consolidated and unconsolidated rock with down the hamer drilling rig or combination rig with pvc pipe and installation of submersible pump set with all acessories |
| 768 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the engineer in charge including use of own rig with its accessories ,tools and plant and consumables etc for lowering of 200mm/150mm dia G.I.P.V C/M.S casing pipes for housing fitted with socket and with or without well screen as for the necessity for soft ,medium,hard and boulder formation( G.I/P.V.C/M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well) 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only |
| 769 | Drilling of 200mm dia bore (1 nos ) |
| 770 | 00mtr to 60mtr |
| 771 | Drilling of 150mm dia bore |
| 772 | 61mtr to 120mtr (2 nos ) |
| 773 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity form ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and dotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials |
| 774 | Lowering of 200mm dia P V C casing pipes |
| 775 | 00mtr to 60mtr |
| 776 | Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 PART-II specification length of pipe (laying length) will be 3 mtrs.The pipes shall be supplied with both external threaded with free socket. The pipe having external thread at one end i.e. female & or belled end . The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber 'O' ring to make the joint water tight color of the pipe shall be blue The name of the manufacture along with batch.No class of pipe shall be stranded legibly of each pipe length |
| 777 | 200mm dia PVC (sch-80) pipe (As Per SoR -2022) |
| 778 | Supplying all materials, labour, T & P and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all com |
| 779 | Cleaning & developing the tube well with supply of compressor worked till clear & adequqte discharge is obtained from the tube well including supply & use of all necessary equipment & labour as per directin of the Engineer in charge |
| 780 | By DTH Rig |
| 781 | Supplying all materials, equipments,labour & conducting reconnaissance survey , integrated Hydrological & Geophysical (Electrical resistivity Method) survey & selection of potential source for exploration of ground water including selection & recommend |
| 782 | Rocky terrain with boulder formation for 300m depth |
| 783 | Supplying all materials, labours, T&P and providing fitting & fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase /1 phase line voltage ranging from 320 volt to 450 volt conforming to Si 8034/89 with following specifications with suitable control panel ,jointing with GI/PVC/HDPE pipes,electrification,testing, commissioning ,trial running, conveyance of all materials to worksite , payment of taxex etc all complete as per specification & direction of the Engineer in charge (Texmo/crompton Greaves/ Kirloskar make) |
| 784 | 2HP Single phase 3 stage vertical/Horizontal submersible pump set at head renge of 30 to 54 mtr with discharge capacity 155 to 110 L P.M with outlet dia 32mm |
| 785 | Dol Control panel |
| 786 | 40mm dia steel short piece |
| 787 | Well cap |
| 788 | 50mm size CI bracket |
| 789 | 25 sqmm flat cable |
| 790 | 20 mm dia rigid UPVC pipes |
| 791 | Steel ropes with cover |
| 792 | Supplying all materials ,labour, T&P and providing and fixing to wall or celling and floor HDPE pipes and pipe fiting conforming to IS: 4984/2000(10KGF/SQCM) of the following nominal bore with clamps & joining by Fusion welding method including testing making good the wall celling & floor all complete as per specificaations 7 direction of the engineer in charge |
| 793 | 32mm dia HDPE pipe |
| 794 | Borewell Chamber |
| 795 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the engineer-in-charge.1.20x1.20x0.40= |
| 796 | Supplying all matrials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all complete as per direction of the engineer in charge. |
| 797 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering , curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the engineer in charge. In ground floor 1.20x1.2x0.15= |
| 798 | Supplying all matrials, labour, T&P and providing brick work with fly ash brick having crushing strength not less than 75kg/cm2 with dimensional tolerance 8 percent in cement mortar (1:6) including watering , curing, conveyance of all materials to worksite, payment of royalty, taxec etc all complete as per specification and direction of the engineer incharge. In F&P 2(1.15+0.65)X1.00X0.25= |
| 799 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and trying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the engineer in charge. In ground floor. |
| 800 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard brocken granite chips including watering, curing , conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the engineer in charge. In ground floor. |
| 801 | Supplying all maerials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering , curing, conveyance of all materials to worksite, payment of royalty, taxes etc all materials to worksite,payment of royalty, taxes etc all complete as per specification and direction of the engineer in charge. In ground floor (inside/outside) |
| 802 | INTERNAL P.H. & SANITARY WORK. |
| 803 | WATER SUPPLY. |
| 804 | Supplying, installing, fixing, jointing, testing and commissioning of approved make. Chlorinated Polyvinyl Chloride pipes (CPVC) SDR.11 pipes confirming to ASTM standards with necessary fittings for inetrnal toilet water supply upto 50 dia , and above 50mm dia pipe schedule 40 with fitting shall be schedule 80 ASTM IPS. The fittings and specials such as tees, elbows,couplers, bends, enlargers etc.,m with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement martor 1:1 restore the same original condition neately as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846 and above 50mm dia primer P-70, and solvent confirming to ASTM F-4931 / 724 All exposed pipe shall be painted with latex paint. (for shafts, basement ceiling ringmain Terrace & PRM).The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. Make:- Supreme/Ashirbad/AKG. |
| 805 | 20 mm dia C-PVC pipe (Oriplast/Supreme) |
| 806 | 25 mm dia C-PVC pipe (Oriplast/Supreme) |
| 807 | 40 mm dia C-PVC pipe (Oriplast/Supreme) |
| 808 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings etc. all complete as per P.H. specification and direction of Engineer-in-charge. 250 mm thick wall |
| 809 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages as per direction of the E.I.C. |
| 810 | Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of the Engineer-in-charge. |
| 811 | SANITARY FIXTURES. |
| 812 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Water Closet & cistern fitting (European type W.C. pan) of Hindware/Jaquar/Parryware with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer-In-Charge. |
| 813 | Supplying all materials, labour, T&P and fixing Health Faucet of Hindware/Jaquar/Parryware complete with Chromium plated brass brackets fixed to wooden plugs with Chromium plated brass screws as per specification and direction of the Engineer-In-Charge. |
| 814 | Supplying all materials, labour, T&P and fixing standard sized two way Bib cock of Hindware/Jaquar/Parryware of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. 15mm dia CP Two way bib cock with Flange. |
| 815 | Matrix Set-1 (WB 65X35 with one pair mounting brackets, EWC & cistern complete with fittings & seat cover, one no hinged rail 76 cm and five nos of grab rail 60cm) Make-jaquar E.W.C,(Size- 390 x 365 x 540, S TRAP) cm ,Cat No-jaquar CNS-WHT-551S & Cistern complete with fittings & seat cover,Wash Basin : 46 x 36 cm, one no. hinged rail 76 cm & 4 nos. of grab rails 60 cm. |
| 816 | Supplying all materials, labour T&P and fixing of Under Counter wash basins with bottle trap & cp fittings of Hindware/Jaquar/Parryware of approved make in all floor of approved quality including cutting the walls & floor and making good the damags with cement concrete e.t.c including all tsxes,duties,transportation e.t.c. All complete as per specification and direction of the Engineer-In-Charge.(Size: 560x430x195 mm) |
| 817 | Supplying all materials, labour, T&P and fixing standard sized pillar cock of of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 15mm dia brass pillar cock.(MAKE -JAQUAR) |
| 818 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C.sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer-in-charge. Swivel Mirror Rectangular Shape(630x450) |
| 819 | Supplying all materials, labour, T&P and fixing standard sized Chromium Plated Glass Shelf of Hindware/Jaquar/Parryware complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge. |
| 820 | Supplying, installing, testing and commissioning of approved make White Viterous urinals 3.8 LPM supported by CI/MS bracket duly painted, including CP brass waste with dome type grating, CP cast brass bottle trap with extension piece, wall flanges, automatic flushing systems for urinal to ensure flusing only immediately after use, comprising of all plumbing, electronic and electrical items. CP brass flush pipe with CP brass elbow, CP brass spreader, CP wall flange, infrared photo cells (Sensor), eyes electrically operated solenoid valve, gate valve, black box and necessary wiring in conduit from solenoid value to black box and to mains etc, complete. Including necessary wall cutting/chasing and making good, as required. , jaquar,Size:385x325x635mm,jaquar-URS-WHT-13253N |
| 821 | Supplying all materials, labour T&P and fixing URINAL FLUSH VALVE FLV-1095NG (Make: Jaquar) of approved make etc complete including cost of all materials complete as per PH specification and direction of Engineering-in-charge |
| 822 | Providing & Fixing granite slab with Table rubbed, edges rounded and polished of size 75x50 cm deep and 18mm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 as per direction of Er-in-charge. |
| 823 | Supplying all materials, labour, T&P and fixing standard sized Robe Hook of Hindware/Jaquar/Parryware complete with all as per specification and direction of the Engineer in charge. |
| 824 | Supplying all materials, labour, T&P and fixing Kitchen Sink of Nirali Anti-scratch Popular Elegance BG Large (1145 X 510)mm Boul Size (560 X410 X 215) mm of approved make etc complete including cost of all materials complete as per PH specification and direction of Engineering-in-charge |
| 825 | Supplying all materials, labour, T&P and fixing standard sized SINK cock of Hindware/Jaquar/Parryware of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. 15mm dia CP Two way bib cock with Flange Cat. No.:JaquarLYR-38347S |
| 826 | Supplying all materials, labour, T&P and fixing standard sized 15mm dia angular Stop cock of Hindware/Jaquar/Parryware of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. |
| 827 | Supplying all materials, labour, T&P and fixing standard sized Chromium Plated soap case Hindware/Jaquar/Parryware complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge. |
| 828 | Supplying all materials, labour, T&P and fixing standard sized Chromium Plated brass towel ring of Hindware/Jaquar/Parryware complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge. |
| 829 | Supplying all materials, labour, T&P and fixing standard sized Chromium Plated brass towel rail of Hindware/Jaquar/Parryware complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge. |
| 830 | Supplying all materials, labour, T&P and fixing standard sized Chromium Plated Paper Holder of Hindware/Jaquar/Parryware complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge.jaquar CAN-1153S |
| 831 | Fixing of 32 mm dia Brass/GM Fulway Valve confirming to IS : 781-1995 of approved make as per specification complete as per direction of Er-in-charge. 32mm dia brass or gun metal full way valve.(Make- zoloto or equivalent.) |
| 832 | Fixing of 20 dia Brass/GM Fulway Valve confirming to IS : 781-1995 of approved make as per specification complete as per direction of Er-in-charge. 20mm dia brass or gun metal full way valve.(Make- zoloto or equivalent.) |
| 833 | Supply all materials, labour, T&P and providing fitting & fixing (Aqua guard)Aquaguard Blaze RO+UV+MTDS Water Purifier pure with water storage capacity 4 liters along with 2 nos of fancets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc. all complete as per approved drawing, specification and direction of the EIC. |
| 834 | EXTERNAL P.H.E & SEWAGE SYSTEM. |
| 835 | Supplying all materials, labour, T & P and constructing of Inspection chamber(IC) of the following inside size with 8 cm thick R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g. chips, foundation concrete (1:4:8) using 40mm size h.g. metal on bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mm x100mm size gully trap, 150mm x150mm C.I gratig etc. all complete as per aproved drawing, specification and direction of Engineer-in-charge. |
| 836 | Size- 600 x600 mm |
| 837 | Size- 760 x760 mm |
| 838 | Size- 900 x800 mm |
| 839 | Providing and fixing square mouth S.W GULLY TRAP(G T) class SP-1 complete with CI grating brick masonry chamber with water tight CI cover with frame of 300X300mm size (inside),the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per the standard desifn. brick masonry chamber of size 180 X 150 mm size complete as per approved specification and direction of the Engineer in charge |
| 840 | Size- 300x300 mm |
| 841 | Supplying all materials, labour, T & P and constructing of MAN HOLE chamber(M H) of the following inside size with 8 cm thick R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g. chips, foundation concrete (1:4:8) using 40mm size h.g. metal on bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mm x100mm size gully trap, 150mm x150mm C.I gratig etc. all complete as per aproved drawing, specification and direction of Engineer-in-charge. |
| 842 | Man-hole chamber of size 1200x900x900mm |
| 843 | Supplying all materials, labour, T & P and constructing RAINWATER COLLECTION PIT chamber of the following inside size with 8 cm thick R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g. chips, foundation concrete (1:4:8) using 40mm size h.g. metal on bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mm x100mm size gully trap, 150mm x150mm C.I gratig etc. all complete as per aproved drawing, specification and direction of Engineer-in-charge. |
| 844 | 450mmx4500mm with RCC cover |
| 845 | Fixing double layer cylinderical water storage tanks conforming to IS: 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height and placing the tank to the required position etc all complete as per specification and direction of the engineer in charge.DOUBLE LAYER 2000 LIT. CPVC TANK |
| 846 | Supplying, fixing and testing PVC soil, waste, Rain and vent pipes (SWR) SUPREME confirming to IS13592 : 1990, type B with rubber ring/Solvent (confirming toIS5382) joint inclusive of allnecessary specials like bends, tees,offsets, door bends, junctions, cowls, etc.,laid underfloor/ fixed on walls,and in pipe shafts etc., complete.The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. Make:- Supreme/Ashirbad/Astral/Sentini |
| 847 | 40 mm dia . |
| 848 | 50 mm dia . |
| 849 | 75 mm dia . |
| 850 | 110 mm dia . |
| 851 | 110 mm dia Rain pipe. |
| 852 | 160 mm dia. |
| 853 | Supplying, fixing and testing PVC floor trap with SS frame and cover 75mm dia outlet fixed on a bed of cement concrete with (Heavy duty type) etc., complete. |
| 854 | ASTRAL -M252003207 |
| 855 | 40mm x 75 mm dia |
| 856 | Supplying, fixing and testing PVC Nahani trap with SS frame and cover 75mm dia outlet fixed on a bed of cement concrete with (Heavy duty type) etc., complete. |
| 857 | ASTRAL-M252007006 |
| 858 | 75 mm dia |
| 859 | Providing ,fixing , testing and commissioning of approved make PVC vent cowl with necessary accessories etc., complete. |
| 860 | 75 mm dia |
| 861 | 110 mm dia |
| 862 | Providing ,fixing , testing and commissioning of approved make PVC CLEAN OUT PLUG with necessary accessories etc., complete. |
| 863 | 75 mm dia |
| 864 | 110 mm dia |
| 865 | Supplying all materials, labours,T&p and laying trenches (to level or slope) unplasticized P.V.C pipe conforming to IS4985/2016 of the following out side dia for pressure rating PN-6 including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification,providing and laying in trench cement concrete(1:4:8) with 40 mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing e.t.c all complete as per P.H specification and direction of the Engineer in charge |
| 866 | 160 mm dia U-PVC pipe with al-round concreteing |
| 867 | 200 mm dia U-PVC pipe with al-round concreteing |
| 868 | 30 USER SEPTIC TANK |
| 869 | Soak Pit of 1.2 mtr dia and 2.2 mtr depth |
| 870 | ELECTRICAL |
| 871 | Recessed wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6 Amp, 250 V clip in type switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size , with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. (Make of Wires- Finolex/Anchor/Polycab/HAVELLS/RR KABEL/KEI) or equivalent) (Make of Conduit-AKG/Anchor/Polycab or equivalent reputed make A catagory ISI marked as approved) (Make of switch/socket- Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa)/Havells(Equivalent model) or equivalent) (Make of accessories- Anchor/Havells) (Make of G.I box, face plate & cover-Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa) or equivalent reputed make & model A catagory ISI marked as approved) Group C |
| 872 | Recessed wiring to secondary light point looped from primary light point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including 3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer in charge.(Make of Wires- Finolex/Anchor/Polycab/HAVELLS/RR KABEL/KEI) or equivalent) (Make of Conduit-AKG/Anchor/Polycab or equivalent reputed make A catagory ISI marked as approved) (Make of switch/socket- Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa)/Havells(Equivalent model) or equivalent) (Make of accessories- Anchor/Havells) (Make of G.I box, face plate & cover-Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa) or equivalent reputed make & model A catagory ISI marked as approved) Average Length: 3 mtr |
| 873 | Recessed wiring to Twin control light point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6Amp, 250 V clip in type 2way switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size , with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels / V Guard )Group C |
| 874 | Recessed wiring to ceiling fan point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6Amp, 250 V clip in type switch ISI marked and stepped modular Regulator ISI marked mounted on G.I modular box with face plate & cover of suitable size , with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels / V Guard )Group C |
| 875 | Recessed wiring for 5 / 6 amp socket outlet with 6Amp, 250 V clip in type modular switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection on same switch board as per direction of Engineer in Charge. (Make of switch/socket- Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa)/Havells(Equivalent model) or equivalent) |
| 876 | Recessed wiring for 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6Amp, 250 V clip in type switch ISI marked mounted on G.I moular box with face plate & cover of suitable size , with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection on separate board as per direction of Engineer in Charge. (Make of Wires- Finolex/Anchor/Polycab/HAVELLS/RR KABEL/KEI) or equivalent) (Make of Conduit-AKG/Anchor/Polycab or equivalent reputed make A catagory ISI marked as approved) (Make of switch/socket- Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa)/Havells(Equivalent model) or equivalent) (Make of accessories- Anchor/Havells) (Make of G.I box, face plate & cover-Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa) or equivalent reputed make & model A catagory ISI marked as approved) |
| 877 | Recessed wiring for 2 x 6 amp socket outlet controlled by 2 nos 6Amp, 250 V clip in type switch ISI marked mounted on single G.I moular box with face plate & cover of suitable size including all accesories and connection on separate board as per direction of Engineer in Charge. (Make of switch/socket- Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa)/Havells(Equivalent model) or equivalent) |
| 878 | Recessed wiring for 6 pin 16 amp socket outlet with 16Amp, 250 V clip in type switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer in Charge. (Make of switch/socket- Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa) / Havells (Equivalent model) or equivalent) |
| 879 | Recessed wiring for Projector socket outlet with 16A plug socket and 16A control switch at nearest separate location |
| 880 | Supplying and fixing of 25Amp socket & 25Amp, 250 V moular type starter ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer in Charge. |
| 881 | SUBMAIN. |
| 882 | Recessed wiring to submain in 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 25 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 4.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire- Finolex/Anchor/Polycab/ HAVELLS/RR KABEL or equivalent) (Make of conduit-AKG/Anchor/Kinjal or equievalant) |
| 883 | Recessed wiring to submain in 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire- Finolex/Anchor/Polycab/ HAVELLS/RR KABEL or equivalent) (Make of conduit-AKG/Anchor/Kinjal or equievalant) |
| 884 | Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire- Finolex/Anchor/Polycab/ HAVELLS/RR KABEL or equivalent) (Make of conduit-AKG/Anchor/Kinjal or equievalant) |
| 885 | Recessed wiring to submain in 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire- Finolex/Anchor/Polycab/ HAVELLS/RR KABEL or equivalent) (Make of conduit-AKG/Anchor/Kinjal or equievalant) |
| 886 | DISTRIBUTION BOARD . |
| 887 | Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ Isolator) |
| 888 | 4 WAY (4 + 12) TPN DOUBLE DOOR, HORIZONTAL TYPE |
| 889 | Supply and fixing of single pole MCB with sheet steel enclosure, distribution board, on surface /recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, phosphate and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ ISOLATOR) (Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalent model) /ABB(Equivalant model) or equievalant. |
| 890 | 12 way SPN , MCB DB double door |
| 891 | Supply and fixing of following rating 240 V Minature Circuit Breaker (MCB) having a sensitivity current up to 10kA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required. (Make-LEGRAND- DX3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalant model) /ABB(Equivalant model) or equievalant. |
| 892 | 6 amp to 32 amp rating SP MCB , \\"c\\" series, 10KA breaking capacity |
| 893 | Supply and fixing of following rating 240 V Residual Current Breaker with Overcurrent protection (RCBO) having a sensitivity current up to 100mA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required. (Make-LEGRAND- DX3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalant model) /ABB(Equivalant model) or equievalant. |
| 894 | 25 to 40 amp rating DP RCBO, 30mA |
| 895 | 63 amp rating 4P RCBO, 100mA |
| 896 | CABLE . |
| 897 | Supply of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of following sizes of cable as required. (Make- POLYCAB / FINOLEX / HAVELLS) or equievalant reputed ISI MARKED MAKE |
| 898 | 4 C x 16 sq.mm Al |
| 899 | Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface as required. |
| 900 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accesories like socket , bend, couplers etc conforming to IS 14930, part II complete with fitting and cutting jointing etc direct in ground (75mm below ground level) inciuding excavation and refilling the trench but excluding sand cushioning and protective covering etc complete as required. |
| 901 | 120 mm dia (OD -120mm & ID- 103mm nominal) |
| 902 | END TERMINATION |
| 903 | Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required. |
| 904 | 4 C x16sq.mm Al |
| 905 | EARTHING |
| 906 | Supply and fixing of chemical Earthing of with 3mtr long 40mm dia chemical filled comound and GI earth electrode including excavation of earth pit with highly conductive back filled chemical compund of 2 x 25kg , brick work in cement mortar masonary work with removable cover for Earth pit chamber of suitable size including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 907 | Supplying and laying 25 mm x 6 mm G.I earth strip ISI marked at 0.5 meter below grond level as strip earth electrode including soldering etc. as required |
| 908 | Supplying and laying 25 mm x 5 mm copper strip on surface or in recess for connection etc as required. |
| 909 | LIGHTNING ARRESTOR |
| 910 | Providing and fixing of lightning conductor finial made of 25mm dia 300 mm long, G.I tube,having single prong at top,with 85mm dia 6 mm thick G.I base plate including holes etc. complete as required |
| 911 | Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) |
| 912 | Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run) |
| 913 | Providing and fixing of testing joint, made of 20 mm x 3 mm thick G.I. strip, 125 long with 4 nos of G.I. bolts, check nuts and spring washer etc complete as required. |
| 914 | Reveting, sweating and soldering of copper / G.I. tape ( with another copper / G.I. tape, base of the finial or any other metallic object) as required |
| 915 | Providing and laying of G.I. tape 32 mm x 6 mm from earth electrode directly in ground as required. |
| 916 | Earthing with G.I. earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (But wih out charcoal and salt) as required. |
| 917 | Extra for using salt and charcoal for G.I or copper plate earth as required |
| 918 | FIXTURE |
| 919 | Supply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting /LED fitting of all sizes complete with all accessories and lamp etc. directly on ceiling /wall or recessed in false ceiling , including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required. |
| 920 | Surface mounted indoor type 20W SINGLE LED TUBE Luminaire with LED Lamp Similar to WIPRO Cat No. LL20-281-XXX-65AL1/ JAQUAR / Philips / Halonix / Panasonic or equivalent. |
| 921 | Surface/ Recess mounted indoor type 15W ROUND LED Luminaire with LED Lamp Similar to WIPRO Cat No. LD90-191-XXX-65-XX or equivalent. |
| 922 | Surface/Recess mounted indoor type 12W ROUND LED Luminaire with LED Lamp Similar to WIPRO Cat No. LD90-141-XXX-65-XX or equivalent. |
| 923 | Surface mounted indoor type 10W MIRROR LED Luminaire with LED Lamp Similar to WIPRO Cat No. LL20-111-XXX-65NE3 or equivalent. |
| 924 | Supply , fixing & termination of 30watt LED street light fitting complete with cover, GI pipe bracket, necessary wiring from loop-in-box with 3Cx1.5 sqmm copper wires inside PVC pipes etc complete as required with all materials similar to HAVELLS Cat No. LHEXAYP7PN6K030 or equivalent |
| 925 | Supply, Installation, Testing and Commissioning of ceiling fan 1200mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required. |
| 926 | Supply, Installation, testing and commissioning of exhaust fan of 300 mm sweep 900 rpm in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etc as required. |
| 927 | TELEPHONE & DATA |
| 928 | Recessed wiring to telephone point with clip in type modular telephone socket (RJ 11) ISI marked mounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge. |
| 929 | Recessed wiring to LAN point with clip in type modular lan socket (RJ45) ISI marked mounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge. |
| 930 | Supplying and fixing of 25mm PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required. |
| 931 | Supplying and drawing one pair, 0.5 sq.mm FR PVC insulated coper conductor, unarmoured telephone cable in existing surface / recessed PVC conduit as required. |
| 932 | Supplying and drawing UTP 4 pair LAN cat-6 cable in the existing surface / recessed PVC conduit as required.Make :Derwiser, Finolex, Tyco Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail