| 1 | M&L for Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius built in CM 1:6 incl demolition of brick work built in cement mortar incl all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work and precast concrete articles, complete all as specified and directed . |
| 2 | Taking down cement plaster from brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge. |
| 3 | M & L Rendering 15 mm thick on fair faces of brick work or concrete surfaces ion cement mortar 1:4 finishing the surface even and smooth ( without using extra cement) in two layers with WPC complete all as specified.(WPC measured separately). |
| 4 | M&L Rendring 15mm thick in cement mortar 1:6 on fair faces of brick/concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 5 | Supply only liquid water proofing compound compete all as specified. |
| 6 | M&L for Rendering 5mm thick in cement plaster 1:3 on ceiling surface finished even and smooth without using extra cement, complete all as specified and directed by Engr-in-charge |
| 7 | M&L for preparation to new plastered surfaces of wall applying one coat of wall putty 2mm thick and two coats of oil bound distemper over a coat of primer, complete all as specified and directed . |
| 8 | M&L for preparation of newly plastered surfaces on wall/roof projections including facia, cornices etc and applying exterior water proof wall care putty @ 1Kg (undiluted) per sq mtr of average thickness 1mm or 2mm over the prepared plastered wall/ceiling surfaces, one or more coats and grinding the puttied surfaces with mechanical grinder for make the surface even and smooth for receiving primer and applying Two or more coats of 100% Premium acryli smooth exterior emulsion paint having VOC less than 50 gm/litre and UV resistane , Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives & Color stay technology, excellent dirt pickup resistance @ 1.67 litre/10 Sqm diluted with water as per manufacturers instructions over and including priming coat of exterior primer applied @ 0.9 litre (undiluted) /10 Sqm over new putyy surfaces of wall/ceiling complete all as specified and directed.Note : Paint using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed, incl. required colour shed. |
| 9 | M&L for preparation of new plaster surface of ceiling and applying 2mm thick of wall putty, and applying two coats of OBD complete all as specified and directed by Engineer-in-Charge (Make : JK Wall putty) |
| 10 | M&L for Complete removal of existing treatment on external wall/roof projections including facia, cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit to make surface clean, free from dust, loose paint etc by skilled labour with mechanial sander having RPM of 1500 - 2700 rpm, with internal dust extraction system for clean enviornment and preparation of old plastered/srapped surfaces of wall/ceiling by filling cracks by external wall putty/crack fill paste and applying exterior water proof wall care putty @ 1Kg (undiluted) er sq mtr of average thickness 1mm or 2mm over the prepared plastered wall/ceiling surfaces, one or more coats and grinding the puttied surfaces with mechanical grinder for make the surface even and smooth for receiving primer and applying Two or more coats of 100% Premium acryli smooth exterior emulsion paint having VOC less than 50 gm/litre and UV resistane Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives & Color stay technology, excellent dirt pickup resistance @ 1.79 litre/10 Sqm diluted with water as per manufacturers instructions over and including priming coat of exterior primer applied @ 0.9 litre (undiluted) /10 Sqm over old/new putyy surfaces of wall/ceiling complete all as specified and directed.Note : Paint using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed.incl. required colour shed . |
| 11 | M&L Preparation of old plastered or painted surfaces of wall by complete removing with mechanical means/grinding of existing treatment by grinder machine (scrubbing, washing down etc), applying one coat of wall putty of minimum 2 mm thick over & two coats of oil bound distemper complete all as specified and directed. |
| 12 | Prepration of old surfaces of ceiling and applying one coats of OBD complete all as specified and directed by Engineer-in-Charge. |
| 13 | M&L for preperation of old painted wooden ceiling surfaces/joinery, wall and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. |
| 14 | French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler one or more coats on old work complete all as specified and directed by Engineer-in-Charge. |
| 15 | M&L for preperation of old painted steel surfaces and applying one coat of synthetic enamel paint over 10 cm in width or girth complete all as specified and directed by Engineer-in-Charge. |
| 16 | Note:-Item No-01 to 20 shall be carried out up to 20 mtr of building height.The work for periodical services shall include the following and the rates quoted by the bidders shall include the same :-(a) Use of Scaffolding , trestles, ladders, cradles etc necessary for execution of work and protective measures.(b) Removing of Nails, making good holes, cracks etc.(c) Work in patches and in narrow/widths, bands, cornies, pilasters etc and cutting in edge of line where necessary.(d) Spreading and removing covering to doors, windows, floors, fittings etc to protect them from splashes.(e) Washing floors, cleaning glass, joinery, electric fittings, wiring etc. Drops and splashes of paint to be cleaned to the entire satisfaction of Engineer-in-Charge.(f) Sample patch of 10 Sqm be prepared considering all the items of periodical and shall be got approved from GE prior to carring out future work.(g) The work shall be carried out up to 4 the storey.(h) Incl removal of vegetation on walls incl roots on wall surfaces and removal of all debrries upto 5 Km.(j) incl. colour shed where required. |
| 17 | Supply and install hi wall split units indoor/outdoor inverter type (Hot & Cold) complete with cordless remote control unit and with inbuilt air Heating and Cooling arrangement and ioniser & plasma filter for better indoor air quality and Digital Inverter twin rotary of capacity 1.5 TR Including all fixing arrengment, All as specified and directed. |
| 18 | M&L for Sub Main wiring using FRLS Insulated unsheathed, multistrand copper conductor FRLS PVC cable 2 runs of size 4 sqmm for phase and neutral and 4 Sq mm for earthing. drawn through rigid PVC conduit of suitable size fixed on wall/ground/Ceiling etc., and complete all as directed by Engr-in-Charge. Note: Phase should be Red / Yellow / Blue, neutral should be black and earthing wire should be green in colour. Two runs of cable for phase / neutral and one run of cable for earth incl conduit will be measured and paid as one unit length. |
| 19 | Supply and fixing Single pole and neutral Sheet Metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 240 Volts complete all as specified and directed. |
| 20 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4.0 KVA. |
| 21 | Rigid non-metallic PVC conduit of dia 20 mm exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. |
| 22 | M&L for additional length of copper pipe for installing split type air conditioner at site of suitable size/guage complete all as directed by Engineer In Charge. Note Additional quantity both suction and discharge pipe has considered as one RM. |
| 23 | Amount of Credit Schedule for Schedule 'A' Part-ll shall be deducted from total quoted amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information |