| 1 | Surface dressing n exc 15cm deep in hard/dense soil complete all as specified and directed by Engr-in-Charge |
| 2 | Excavating over areas, n exc 1.5 m deep and getting out in hard/dense soil complete all as specified and directed by Engineer in Charge. |
| 3 | Excavating over areas, exc 1.5 m and n.exc. 3.00m deep and getting out in hard/dense soil complete all as specified and directed by Engineer in Charge. |
| 4 | Excavating over areas, exc 3 m and n.exc. 4.50 m deep and getting out in hard/dense soil complete all as specified and directed by Engineer in Charge. |
| 5 | Excavating over areas, exc. 4.50m deep and n.exc 6.00m deep in hard/dense soil and getting out complete all as specified and directed by Engr-in-Charge |
| 6 | Excavating in trenches in Hard / Dense soil , n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed by Engr-in-Charge |
| 7 | M&L Plain Cement concrete Type B2 1:2:4 40 mm graded aggregate in foundations, filling and mass concrete complete all as specified and directed by Engr-in-Charge |
| 8 | M&L Reinforced cement concrete of M-30 (20mm graded aggregates) (design mix) Foundations, including rafts, footings, foundation beams; plinth beams; for columns, etc.; basement slabs, under-reamed and mass concrete complete all as specified and directed by Engineer in Charge. |
| 9 | M&L Reinforced cement concrete of M-30 (20mm graded aggregates) (design mix) Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed by Engr-in-Charge |
| 10 | M&L Reinforced cement concrete of M-30 (20mm graded aggregates) (design mix) Slabs supported on beams and columns in roofs, landings, balconies, canopies, deck slabs shelves and the like complete all as specified and directed by Engr-in-Charge |
| 11 | M&L of Pre-cast cement concrete block masonry with solid blocks, exc. 10cm in width and Set in cement mortar 1:6 ,Type C1 1:3:6 (20mm graded aggregate) complete all as specified and directed by Engr-in-Charge |
| 12 | M&L for Rendering 15mm thick cement plaster with cement mortar(1:4) on fair faces of brickwork or concrete surfaces finished even and fair complete all as specified and directed by Engr-in-Charge |
| 13 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed by Engr-in-Charge |
| 14 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge. |
| 15 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed by Engr-in-Charge |
| 16 | Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter exceeding 200mm thick complete all as specified and directed by Engr-in-Charge |
| 17 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; exceeding 200mm thick(Horizontal or sloping) complete all as specified and directed by Engr-in-Charge |
| 18 | Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, an similar work all exceeding 20cm wide. (Where RCC/PCC band in walls, spanning and opening, the formwork soffit only shall be paid for under item 07010) complete all as specified and directed by Engr-in-Charge |
| 19 | Mild steel bars 8mm dia TMT bar and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. |
| 20 | Mild steel bars 8mm dia TMT bar and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders |
| 21 | Mild steel bars 10mm dia TMT bar and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 22 | S&F of Fe.290.Gde-E-165 Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to |
| 23 | S&F of 100mm bore of spun pipe dia Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, but fixed to wall complete all as specified and directed by Engr-in-Charge |
| 24 | S&F of 100mm bore of dia slotted vent cowl complete all as specified and directed by Engr-in-Charge |
| 25 | M&L Pre-cast RCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in manhole cover slab set in CM 1:4 complete all as specified and directed by Engr-in-Charge |
| 26 | S&F of 700mm bore of pipe dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed by Engr-in-Charge |
| 27 | S&F of Reinforced concrete pipes Bore of pipe in 150 mm, class NP2, laid and jointed complete with collars complete all as specified and directed by Engr-in-Charge |
| 28 | S&F of Reinforced concrete pipes Bore of pipe in 150 mm ,Bend laid and jointed, complete all as specified and directed by Engr-in-Charge |
| 29 | Loosing filling with gravels or crushed stones of uniform size aggregates of gauge 250 to 400mm in soakage pits, soakage wells complete all as specified and directed by Engr-in-Charge |
| 30 | Loosing filling with coarse aggregate well graded of uniform size aggregates of gauge 150 to 250 mm in soakage pits, soakage wells complete all as specified and directed by Engr-in-Charge |
| 31 | M & L for PCC 1:3:6 type C-2 (Nominal Mix) 150mm thick using 40 mm graded stone aggregate as in foundation filling mass concrete and similar work complete all as specified and directed by Engineer in Charge. |
| 32 | M & L for Walling of random rubble stone masonry, uncoursed, well bonded, bedded and solidly hearted, build in cement mortar 1:4 complete all as specified and directed by Engineer in Charge. |
| 33 | M& L for Walling of random rubble, uncoursed, well bonded, laid dry in retaining walls, abutments and similar work complete all as specified and directed by Engineer in Charge. |
| 34 | M & L for providing RCC type B-1 1:2:4 using 20 mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as complete all as specified and directed by Engineer in Charge. . |
| 35 | M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide ® rough finished surfaces of concrete complete all as specified and directed by Engineer in Charge. . |
| 36 | M&L Concrete bed 1:4:8 type D-2 to drain pipes incl packing under and haunching against the sides of pipes after they are laid and tested bore of pipe in 110 mm.complete all as specified and directed by Engr in Charge. |
| 37 | S&F 110mm dia bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by Engr-in-Charge. |
| 38 | S&F PVC(SWR) pipes single socketed in any length 75 mm dia with rubber joints fixed to walls complete all as specified and directed by Engineer in Charge. |
| 39 | S&F PVC(SWR) vent cowl of dia 75 mm complete all as specified and directed by Engineer in Charge. |
| 40 | Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs blankets any thickness, including cover fillets complete all as specified and directed by Engr-in Charge |
| 41 | M&L 9 mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work in walls complete all as specified and as directed by E-in charge. (Note : 1. Ladders, scaffolding will be provided by Contractor where required. 2. size of wall panel & frame may have to be changed as per the site reqmt) |
| 42 | M&L 9 mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work in Ceiling and Ceiling complete all as specified and as directed by E-in charge. (Note : 1. Ladders, scaffolding will be provided by Contractor where required. 2. size of Ceiling & frame may have to be changed as per the site reqmt) |
| 43 | Dismantling of timber fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section frame workcomplete all as specified and as directed by E-in charge . |
| 44 | M&L second class hard wood timber scantling plain fillets square, rectangular or triangular in section, clean sawn, secured with nails or brads, sectional area exc. 13 Sq cm n.exc 25 Sq cm secured with nails or brads.complete all as specified and as directed by E-in charge . |
| 45 | M&L second class hard wood timber scantling bullnosed, splayed,chamfered or rounded on one edge or face, secured with nails or brads, sectional area exc. 3 Sq cm n.exc 6 Sq cm secured with nails or brads.complete all as specified and as directed by E-in charge . |
| 46 | Dismantling plain or corrugated steel sheeting any guage, thickness including nainital or similar pattern roof covering and wall cladding complete all as specified and directed by Engr-in-Charge. |
| 47 | M&L for Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet .50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed by Engr-in-Charge. |
| 48 | M&L for Pre- painted galvatume aluminum zinc coating GI based plain steel sheet .50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed by Engr-in-Charge. |
| 49 | M&L preparation of new Surfaces untreated surface apply one coat of red oxide,zink chrome and two coat of synthetic enamel (ordinary tint) paint on steel surface, over 10cm in width or girth,not otherwise described complete all as specified and directed by Engr-in-Charge. |
| 50 | M&L for preparation of old painted steel surfaces and applying one coat of synthetic enamel paint on surface of any description over 10cm width or girth complete all as specified and directed by Engr-in-Charge. |
| 51 | Demolition of cement concrete (Unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engr-in-Charge. |
| 52 | M&L for 100 mm thick PCC (1:2:4) type B2 (Using 20mm graded aggregatre) as in floor levelling and finished even and fair without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 53 | M&L for 75 mm thick Cement concrete type C-2, 1:3:6 (20mm graded crushed stone aggregate) as in floor plinth protection, finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 54 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engr-in-Charge. |
| 55 | M&L for Fe 410-W (Gde-E-250 qanlity-A) roof trusses(framed), trussed, purlins, crane gantries, rail and fastening and heavy bracket framing (Beam, tee, angle, channel or flat iron sections) including distance pieces, cleats etc directed by Engr-in-Charge. (Note : Ladders, scaffolding will be provided by Contractor where required) |
| 56 | Demolition of Brickwork / concrete block or stone/ boulder masonry, built in cement mortar complete all as specified and directed by Engr-in-Charge. |
| 57 | M&L Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar, complete type C1 1:3:6 (20 mm graded agg) set in CM 1:4 completed all as specified and directed by Engr-in-charge . |
| 58 | M&L for preparing new surfaces of plastered or unplastered and applying two coat of cement base paint over chalk whiting complete all as specified and directed by Engr-in-Charge. (Note : Ladders, scaffolding will be provided by Contractor where required) |
| 59 | Taking down carefully alluminium / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switchs, sockets, aluminium conductor cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed. |
| 60 | M&L point wiring complete with single core FRLS PVC insulated, unsheathed, multi stranded copper conductor cables 1.5 Sqmm 1100 volts grade, with and incl 1.5 Sqmm FRLS PVC insulated, unsheathed, multi stranded copper conductor cables as continuous earth wire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly at other end, complete wiring drawn through & PVC casing and capping of 25 mm and above (as per conductor run ) medium grade, ISI marked, incl all accessories & fittings / junction boxes / inspection covers etc, with and incl surface PVC Boxes of suitable size fixes with wall surface, Gang box for top cover suitable for fixing of piano type switches / sockets etc, complete all as specified and directed |
| 61 | Description all as per Srl item no. 60.00 here-in-before but with One light / bell / buzzer / exhaust fan point controlled by one no, 1-way, 5 Amps switch. |
| 62 | Description all as per Srl item no. 60.00 here-in-before but One socket outlet 3 pin, 5 Amps on independent board, controlled by one no 5 Amp switch. |
| 63 | Description all as per Srl item no. 60.00 here-in-before but with 2.5 sq mm FRLS copper wire with 1.5 Sqmm FRLS copper earth wire for indpendent 15 Amp point. |
| 64 | S&F in repalcement, of Switch piano type, single pole, one way, 5 amps, 230 volts, complete all as specified and directed. |
| 65 | S&F in repalcement, of Switch Socket combination, two-in-one, 5 pin, 5 Amp, universal type, 230 volts, complete all as specified and directed. |
| 66 | S&F in repalcement, of Switch Socket combination, 6 pin, 5/15 Amp, multipurpose shutter type, 230 volts, complete all as specified and directed. |
| 67 | S&F in repalcement, of Ceiling rose, two to three terminals, bakelite body, 230 volts, complete all as specified and directed. |
| 68 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 69 | S&F in replacement LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal anagement in multiple optics complete with IP 65/66 protection complete all as directed by Engr-in-Charge at site including necessary fixing arrangement like bracket, clamps and nuts and bolts. |
| 70 | S&F in replacement Lamps Holder PVC/ polycabonate by with back plate angular type complete all as specified by Engr-in-Charge. |
| 71 | S & F LED bulb 9W for fixing with lamp holder complete all as specified by Engr-in-Charge. |
| 72 | S&F in replacement exhaust fans made of sturdy Engineering plastic AC single phase 230/ 240 V of size 250 mm sweep with louvre complete in cluding making hole in the wall and making good the disturbed surfaces complete all as directed by EIC at site |
| 73 | S&F in replacement of DB, Single Door, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, SPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof, suitable for incorporation of MCB’s and isolators etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed. |
| 74 | S&F in replacement of MCB, C Curve type, 10 kA, 40 to 63 Amp, SPN with over load and short circuit protection, complete all as directed. Make : Schneider Elect / Legrand / C&S / Hager |
| 75 | S&F in replacement of MCB, C Curve type, 10 kA, 6 to 40 Amp, Single Pole with over load and short circuit protection, complete all as directed. Make : Schneider Elect / Legrand / C&S / Hager |
| 76 | Supply and laying XLPE insulated, armoured, heavy duty electric cable, with stranded aluminum conductor 1100 V grade nominal cross sectional area 16 Sqmm, 2 core laid in trenches, ducts, drawn through pipes across the road/path/along poles/wall/floors/equipment etc including jointing and testing complete all as specified and directed by the Engr-in-Charge |
| 77 | Material and labour for un-reinforced pre-cast concrete cable covers, class LV type-1, flat size 250mm x 150mm x 40mm thick complete all as specified. |
| 78 | Material and labour for sand cushioning to under ground electric cable all as per clause No 19.75 of MES SSR Part-I (1991) |
| 79 | M&L for earthing with galvanized steel earth plate electrode of size 600 x 600 x 6 mm buried directly in ground earth pit not less than 2.25 mtr below of normal ground level with top edge of earth plate should not less than 1.5 mtr below normal ground level and connected to galvanized iron earth lead wire of size 4 mm dia by means of bolts, nuts, washers of galvanized iron or steel all as shown in electrical plate No.3 of MES SSR Part I connecting to earthing test point on completion with and including 15 mm bore GI light grade protection pipe (7.5 mtr long) for earth lead GI lead wire 4mm dia (7.5 mtr long), PCC pit with cover in PCC 1:2:4 type B-1 reinforced with 8 mm dia tor bars @ 80mm C/C, 20mm dia medium grade watering pipe with funnel, wire mesh, common salt, charcoal, necessary excavation and earth work, complete all as specified and directed. Please Enable Macros to View BoQ information |