| Sl. No. | Item Description |
| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody for reuse or for taking credit and making good disturbed surfaces of walls, floors, etc |
| 2 | Material & labour for point wiring complete with single core 1.5 Sqmm (nominal area) PVC insulated multistranded, copper conductor cable (FRLSH) drawn through and including PVC casing capping (ISI marked) and accessories complete including cutting ,chases & making good disturbed surfaces), with plastic laminated backlite sheet top cover 3 mm thick (hylum) fixed with nickel polished screws with washers, earth continuity PVC cable(FRLSH), copper conductor 1.5 Sqmm (nominal area) stranded with green insulation earth wire connected with earth dolly One light point / fan point / bell push point controlled by one way switch 5 Amprs and/or through regulator complete all as specified and directed. complete all as specified. |
| 3 | Description all as per ser item No 2.00 above, but socket out let 3 pin, 5 Amp on same board with other switch. |
| 4 | Description all as per ser item No 2.00 above,e but socket out let 3 pin, 5 Amp on independent board with other switch. |
| 5 | Description all as per ser item No 2.00 above, but using 2.5 sqmm (nominal area) PVC stranded copper conductor cable with 1.5 Sqmm PVC insulated copper cable for continuous earth continuity conductor for 3 pin socket out let 15 Amps on independent board.Note for item 1 to 5 : 1. switch,socket,ceiling rose etc retrived from taking down shall be reused if found serviceable during execution.2. Unserviceable switch,socket,ceiling rose,regulator etc replaced shall be measured and paid separately under relevant item of schedule. |
| 6 | Supply and fixing Sheet Metal enclosure double door for DBs when MCBs to be used SPN- 8 Way with 200Amp rated bus bar complete all as specified and directed including taking down old unserviceable DB of any description. |
| 7 | Supply and fixing Sheet Metal enclosure double door for DBs when MCBs to be used SPN - 12 Way complete all as specified and directed including taking down old unserviceable DB of any description. |
| 8 | Supply and fixing in repair Sheet Metal enclosure double door for DBs when MCBs to be used TPN- 12 (4+8) Way with 200Amp rated bus bar complete all as specified and directed including taking down old unserviceable DB of any description. |
| 9 | Supply and fixing in repair vertical distribution board TPN 4 way (VTPN DB) having pvovison for accommodating and including 100 amp MCCB as incomer and MCBs SP 6-32 amp as outgoing (8 + 12 ) modules as incomer and outgoing inclusive taking down old unsv from position and necessary cutting, chasing, drilling or any other civil work required for mounting the DB at place where directed and making good disturbed surface to match with the existing complete all as specified and directed including taking down old unserviceable DB of any description. |
| 10 | Supply and fixing in repairs two pin and earth metal plug and socket complete with one single pole MCB 20 Amp, 240Volts complete all as specified and directed. |
| 11 | Supply and fix in repair MCB TPN 63 Amp, 240 volts,10 KA, complete all as specified and directed. |
| 12 | Supply and fix in repair MCB SPN 63 Amp, 240 volts,10 KA, complete all as specified and directed. |
| 13 | Supply and fix in repair MCB SPN 40 Amp, 240 volts,10 KA, C-curve complete all as specified and directed. |
| 14 | Supply and fix in repair MCB SPN 32 Amp, 240 volts,10 KA, C-curve complete all as specified and directed. |
| 15 | Supply and fix in repair MCB SP 6 to 32 Amp, 240 volts,10 KA, C-curve complete all as specified and directed. |
| 16 | Supply and fix in repair residual current circuit breaker (RCCB) Double pole, 30 m Amp,25 Amp, 240 volts complete all as specified and directed. |
| 17 | Supply and fix in repair residual current circuit breaker (RCCB) Double pole, 30 m Amp,40 Amp, 240 volts complete all as specified and directed. |
| 18 | Supply and fix in repair residual current circuit breaker (RCCB) four pole, 30 m Amp,63 Amp, 240 volts complete all as specified and directed. |
| 19 | Supply and fixing in repairs Switch piano, flush type 5 Amps, 240 V One Way complete all as specified and directed. |
| 20 | Supply and fixing in repairs Switch piano, flush type 15 Amps, 240 V One Way complete all as specified and directed. |
| 21 | Supply and fixing in repairs socket out let 5 Amps 3 pin flush type for the same board complete all as specified and directed. |
| 22 | Supply and fixing in repairs switch socket combination 5 Amps 2 in 1 flush type multipurposes for independent board complete all as specified and directed. |
| 23 | Supply and fixing in repairs switch socket combination out let 5A/15 Amps, 5 in 1 flush type complete all as specified and directed. |
| 24 | Supply and fixing in repairs bell push, flush type 5 Amps, 240 V One Way complete all as specified and directed. |
| 25 | Supply and fixing in repairs Bell, AC, 230 volts, single pole complete all as specified and directed. |
| 26 | Supply and fixing in repairs Ceiling Rose 3 terminal size 50 x 65 mm surface type complete all as specified and directed. |
| 27 | Supply and fixing in repairs stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd at site complete all as per specified and directed. |
| 28 | Supply and fix in repairs 1X18 watt 4 ft long LED lights fitting , 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceilingrose complete : Havells /Philips/CG. Note (i) Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion. |
| 29 | Supply and fix in repairs 1X9/10 watt 2 ft long LED lights fitting , 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceilingrose complete : Havells /Philips/CG. Note (i) Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion. |
| 30 | M&L for sub main wiring in repairs for power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 4 Sqmm, earth continuity conductor of size 4.0 Sqmm to be drawn through and including PVC casing capping on walls/roof/floors including taking down the old submain wiring all as directed by Engineer in Charge.Notes:- (i) Two wires of 4 sqmm and one wire of 4.0 sqmm and one run of PVC conduit shall be measured as one unit. |
| 31 | M&L for Sub Main wiring in repairs complete with copper conductor, multi stranded, FRLS, PVC insulated and sheathed, 6 Sq mm, two run 1100 volts grade, incl drawn through PVC casing capping of suitable size on wall/roof/floor and 6 Sqmm single run for earthing including taking down the old submain wiring all as directed by Engineer in Charge.Notes:- (i) Two wires of 6 sqmm and one wire of 6.0 sqmm and one run of PVC conduit shall be measured as one unit. |
| 32 | Supply and fixing in repairs decorative outdoor pathway light (landscape lighting) made up of high grade unbreakable polycarbonate materials of capacity 15W LED complete all as specified and directed. Make : Philipst/Havells/CROMPTON. Note (i) Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion. (ii) The contractor should include the rates for PCC as required and nut bolts for fixing the light in the quotated rate. |
| 33 | Supply and fixing in repairs LED flood light 100 watt 230 V AC outdoor type with thermal management inmultiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and direcetd.Note: Contractor provided tools and plants, Light fixing is approx 10 to 15 Mtr hight.. |
| 34 | Supply and fixing in repairs LED flood light 120 watt 230 V AC outdoor type with thermal management inmultiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and direcetd.Note: Contractor provided tools and plants, Light fixing is approx 10 to 15 Mtr hight.. |
| 35 | M& in repair copper strip of size 20x3 mm as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required or as directed |
| 36 | Supply and fixing in repairs square LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with highefficiency PMMA diffuser soft glare free light completewith driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete : Havells or equivalent in Bajaj/Philips. Note (i) Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion. |
| 37 | Supply and fix in repairs exhaust fan, steel body AC single Phase. 230V of size 380mm sweep with, blades, and frame and louvers |
| 38 | Supply and fixing in repairs air circulators wall mounted type for vantilation/cooling of UAV parking space of 600 mm dia,single phase 230/240V,AC, 50 Hz complete all as directed . |
| 39 | Supply and fixing wall mounted fan 300 mm sweep for air vantilation/cooling of space,single phase 230/240V,AC, 50 Hz complete all as directed . |
| 40 | S&F in repairs new generatiion energy saving, enviornment friendly long life LED bldg security light fitting 30/35 Watt230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete withIP 65/66 protection complete and including suitable dia mounting bracket bend or weld to shape and length as required or as directed by Engr-in-charge complete. |
| 41 | Supply and fixing in repairs surface/ceiling light 3watt LED circular/square type with highefficiency PMMA diffuser soft glare free light completewith driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete : Havells or equivalent in Bajaj/Philips. Note (i) Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion. |
| 42 | Supply and fixing in repairs surface/ceiling/wall spot light 6/9 watt LED type with driver, holders & LED lamp suitable for wall/roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete : Havells or equivalent in Bajaj/Philips. Note (i) Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion. |
| 43 | M&L for periodical servicing of installed air conditioner of capacity 1.5/2 TR split air conditoner of any make /type, taking down indoor/outdoor units for cleaning dust/deposits, filters,drain hose,drain tray and chicking for gas pressure and replacement of minor spares required if any and refixing on same position complete all as specified. |
| 44 | M&L for charging/top up refrigerant suitable for existing model of air conditoners and testing for proper cooling and leakage complete for AC/water cooler/refrigerator of any capacity all as specified and directed. |
| 45 | Taking down or out existing cable of sizes 2/3.5/4 core 16 sqmm to 50 sqmm from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by Engineer in charge Note :(1) Excavation / cutting of road or floor/ GI pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule2. Serviceable bricks/pcc cover retrived during taking out shall be reused. Unserviceable bricks/pcc covers shall be replaced with new one whereever required. |
| 46 | Relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 2/3.5/4 core 16 to 50 sqmm in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified Note ;- Lugs and Glands will be measured and paid separately. |
| 47 | Supply & Laying XLPE Cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 16sqmm 4 core including necessary cable lugs, glands, insulation tape and deposited to MES store yard complete all as directed and specified. |
| 48 | All as per item Sl No 51 above but of size 16 sqmm 2 core |
| 49 | All as per item Sl No 51 above but of size 25 sqmm 4 core |
| 50 | All as per item Sl No 51 above but of size 35 sqmm 3.5 core |
| 51 | All as per item Sl No 51 above but of size 50 sqmm 3.5 core |
| 52 | M&L straight through joint (Heat Shrinkable) for under ground PVC insulated and PVC sheathed armoured heavy duty XLPE cables with aluminium conductor including jointing kit, including making joints for the cable of size 16sqmm x 4 core cables including testing and commissioining complete all as specified |
| 53 | All as per item Sl No 56 above but of size 25 to 50sqmm x 3.5 / 4 core, as per the size of existing UG cable. |
| 54 | Supply & replace digital type Ammeter 96X96 mm square Flush mounted case of class 1.0 MAKE : ELMEASURE / AE / IMP / MECO / MEI / HPL |
| 55 | Supply & replace digital type Voltmeter 0-500V, 96X96 mm square Flush mounted case of class 1.0 MAKE : ELMEASURE/ AE / IMP / MECO / MEI / HPL |
| 56 | Supply & replace CT 400 - / 5A, 200/5A or 100/5A for ammeter MAKE : AE / IMP / MECO / MEI / HPL |
| 57 | Excavation in trenches in soft / loose soil not exceeding 1.5 Mtr in wide and not exc. 1.5m in depth for taking out / laying of under ground cable in trenches or cable ducts all complete all as specified. |
| 58 | Returning, filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick in soil after repairing / jointing and laying and testing of cables complete all as specified |
| 59 | Removing surplus soil to a distance not exceeding 50 Mtr and deposited at a level not exceeding 1.5 mtr above from the starting point complete all as specified |
| 60 | M&L natural river sand as cushioning of cables including spreading and punning down all as per clause No 19.75 of SSR part -I all as specified. Note : punned thickness shall be measured for payment purpose |
| 61 | Supplying & Laying Sub Class `B’ bricks, old size, kiln burnt, laid with axis of brick perpendicular to the axis of the cable, for protection of cable all as specified and directed by Engr-in-Charge. |
| 62 | M&L for cutting existing road / PCC drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with PCC 1:3:6 type CI using 20mm graded aggregates complete all as specified |
| 63 | M&L for 50mm dia GI pipe medium grade galvanised for cable protection and sealing both ends including taking out old pipe complete all as specifie. MAKES : TATA/JINDAL/UTKARSH / SURYA ROSHINI |
| 64 | Supply and fix in repair maintenance free battery 12V, 150 AH for battery bank set including initial filling & Charging complete all as specified and directed by Engineer-in-Charge. |
| 65 | Supply, installation and testing of automatic battery charger for 12/24/36/48 volt DC from 220/230V AC supply source with boost charging option suitable for charging lead acid/SMF battery and having indication for mains, float charging, boost charging, DC voltmeter,DC fail, AC fail alarm etc with circuit breaker for incoming supply, output load, over voltage, short circuit, reverse polarity and low and high voltage protection all accessories housed in heavy duty sheet metal enclosure, poweder coated finsih floor mounted complete all as specified and as directed. |
| 66 | Supply & replace 250 A 4 pole MCCB, 36 KA, 415V, 50 Hz, AC supply adjustable type of thermal and megnatic setting including necessary cable lugs & wire etc complete all as specifeid and directed. MAKES : Legrand / Seimens / ABB |
| 67 | Supply & replace 250 A 3 pole MCCB, 36 KA , 415V, 50 Hz, AC supply adjustable type of thermal and megnatic setting including necessary cable lugs & wire etc complete all as specified and directed.MAKES : Legrand / Seimens / ABB |
| 68 | Supply & replace 63/100 A 3 pole MCCB, 16KA , 415V, 50 Hz, AC supply including necessary cable lugs & wire etc complete all complete as specified and directed. MAKES : Legrand / Seimens / ABB |
| 69 | Dismantling old unsv conventional earth pit including electrode plate/pipe from position and material and labour for maintenace free modern marconite® conductive concrete based technology earthing system in same or different place where directed with copper earth electrode of suitable size including back fill compound and other accessories as required and recommended by OEM and connecting with copper strip of size 25x3 mm in position (connecting upto 7.5 mtr length max) complete all as specified and as directed and having following specifications :-a) Fixed Carbon 98.5 %b) Ash, Volatile and Water 1.5 %c) Sulphur Content 1.5 % Maximumd) Size Grading (Approx) - 10% below 0.10 mm,5% above 3.15 mm, 85% between 0.10 mm and 3.15 mm(e) Thermal Stability Between (-) 10% and (+) 60% ambient temperature(f) Ultra Low Resistivity(g) Versatile - shall be suitable for all type of soil and climate(h) Consistent Performance(i) Chemically Inert(j) Non-corrosive(k) Maintenance free and life span. |
| 70 | Supply and fix in repair Off Load change over switch 100 Amps, 4 Pole made out of Sheet steel enclosure side operated including replacement of incoming and outgoing lugs and fixing arrangement on panel/wall complete all as specified and directed by Engr-in-Charge. |
| 71 | Supply and fix in repair Off Load change over switch 400 Amps, 4 Pole made out of Sheet steel enclosure side operated including replacement of incoming and outgoing lugs and fixing arrangement on panel/wall complete all as specified and directed by Engr-in-Charge. |
| 72 | M&L painting to LT panel boxes after preparation of the old existing external and internal steel surfaces of feeder pillar boxes/panels/ boards of any description and in any position including removal of disintegrated & deteriorated paint either by hand scrapping or by blow lamps, applying necessary filler coat and stopping as required and applying two coats of synthetic enamelled paint (grey in color) with using spray machine on old prepared surfaces complete all as specified and directed . |
| 73 | M&L in repairs of MS Hinge plate in existing feeder pillar boxes/ panel boards with necessary spot welding etc including making necessary adjustment for free and smooth movement of panel and locking arrangements complete all as specified and directed by Engineer-in-Charge. |
| 74 | M&L Point wiring (Modular Type) using approved colour coading as per IS with unsheathed multistranded FRLSH copper conductor single core 1.5 sqmm (nominal area) PVC conduit ISI marked with all connecting accessories including Recess Metal Wall Box (GI), PVC insulated and unsheated standerd copper conductor single core of size 1.5 sqmm as earth continuity conductor to common earth and connecting to eath dolly (swith and sockets to be measured and paid serately) proper colour coading will be maintained complete all as specified for the following |
| 75 | (a) One light / Fan point controlled by one way switch 5 Amp. |
| 76 | (b) One 3 pin 5 Amp socket out let controlled by one switch on same board. |
| 77 | (c) One 3 pin 5 Amp socket out let controlled by one switch on independent board. |
| 78 | (d) Call bell point. |
| 79 | (e) One light point controlled by swiches two ways. |
| 80 | -do- all as per item No 2 here in before but for one socket out let 3 pin 15 Amp with 4 sqmm PVC copper conductor and 2.5 sq mm PVC insulated copper conductor as earth contiuity conductor. |
| 81 | S/F switch modular flush type 5/6 Amps 230V AC complete one way |
| 82 | S/F switch modular flush type 5/6 Amps 230V AC complete including cover platre two way |
| 83 | Supply and fixing socket combined 2 / 3 pin, 6 Amp modular flush type including cover plate complete all as specified & directed. |
| 84 | S/F socket combination modular type 5 PIN 16 Amp 230 volts AC including cover plate complete. |
| 85 | S&F bell push modular 5/6 Amps 230 V AC including cover plate complete |
| 86 | S&F 1 Module grid frame with cover including blank plate if necessary |
| 87 | S&F 3 Module grid frame with cover including blank plate if necessary |
| 88 | S&F 4 Module grid frame with cover including blank plate if necessary |
| 89 | S&F 6 Module grid frame with cover including blank plate if necessary |
| 90 | S&F 8 Module grid frame with cover including blank plate if necessary |
| 91 | S&F MCB DB CRCA sheet powder coated vertical type TPN 4 way, 415 V double door factory made suitable for incorporating MCB as out going and MCCB as incoming including connecting incoming and outgoing cables, taking out existing unsv DB of any size and making good distribed surface to match with existing complete all as specified. |
| 92 | Supply and fixing in repairs lamp holder battan / angular type complete all as specified and directed suitable for 3 to 7 watt LED lamp |
| 93 | S&F incl testing of LED lamp 220V, 50 Hz AC, of capacity 3 watt complete all as specified and as directed |
| 94 | S&F incl testing of LED lamp 220V, 50 Hz AC, of capacity 5 watt complete all as specified and as directed |
| 95 | S&F incl testing of LED lamp 220V, 50 Hz AC, of capacity 7 watt complete all as specified and as directed |
| 96 | Supply and fix in repairs Fluorescent tube light fitting, LED batten with aluminium housing provided for efficient heat dissipation wirh polycarbonate diffuser and integrated electronic driver, 1x 10 watts 2 feet light fitting with white acrylic cover along with LED lamp white colour complete and connecteing electrically to ceiling rose using PVC insulated and overall sheated flexible copper conductor of size 0.75 Sqmm 3 core fixed complete all as specified and directed. |
| 97 | Supply and fixing in repairs decorative garden light (landscape lighting) made up of high grade unbreakable polycarbonate materials of capacity 8W LED complete all as specified and directed. Make : Bajaj or equivalent/Havells/CROMPTON. Note (i) Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion. (ii) The contractor should include the rates for PCC as required and nut bolts for fixing the light in the quotated rate. |
| 98 | Material and labour in repairs for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of theplate not less 1.5 mtr deep below normal ground level connected to GI earth wire 4 mm dia connected to earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel, GI earth wire will be protected by 15 mm dia GI pipe 'light grade', watering pipe 20 mm dia GI 'light grade', GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of black cotton soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation & earth work, earth wire connected to O/H continuous earth wire on pole, testing the earthing after completion complete all as specified and directed. Note :- (I) Earth pit shall be constructed 50cm from the side of excavation to avoid sinking of pit(II) PCC chamber shall be (1:3:6) using 20mm graded stone aggregate and 50mm thick RCC (1:2:4) type B-1 cover slab reinforced with 8mm dia TMT steel bars @ 100mm c/c both ways complete all as specified and directed. |
| 99 | Supply and fixing in repairs square LED panel light filtting ceiling /recess mounting type with slim, compact, aluminium die cast edge lift panel completer with opal diffuser and electronic driver inbuilt of capacity 34 watt complete all as specified and directed. Make : Havells or equivalent in Bajaj/Philips. Note (i) Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion. |
| 100 | Supply and fixing in repairs decorative wall mounting LED light fitting of capacity 10 watts including lamp made up of high grade engineering plastic material and suitable for B2 LED lamp base complete all as specified and directed by Engr-in-Charge. |
| 101 | S&F in repairs new generatiion energy saving, enviornment friendly long life LED bldg security light fitting of 35W made up of pressure die cast aluminium housing with high efficient LED with IP66 and impact resistance of IK07 and including 43 mm dia mounting bracket bend or weld to shape and length as required or as directed by Engr-in-charge complete. |
| 102 | Taking down ceiling fan any size or sweep after disconnecting, dismantling and removal to trade workshop for repair, complete all as specified and directed. |
| 103 | Opening the unserviceable/burnt fan 1200/1400 mm sweep and cutting of old burnt copper winding and rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, reassembling, testing and connecting for satisfactory run, complete all as specified and directed. |
| 104 | Supply and replacenment gun metal bushes of surface size for ceiling fan/ceiling fan incl necessary mechanical work, complete all as specified and directed. |
| 105 | Supply and replacenment gun metal bushes of surface size for ceiling fan/ceiling fan incl necessary mechanical work, complete all as specified and directed. |
| 106 | Supply and replacing of cord cable, three core 0.5 Sqmm PVC insulated copper conductor cable for connecting ceiling fan, complete all as specified and directed. |
| 107 | Supply and replacing electronic step type fan regulator 240 Volt, 50 C/S, five step, suitable for 1200/1400mm sweep ceiling fan,complete all as specified and directed. |
| 108 | Supply and Fix Capacitor of of 2.5 MFD for ceiling fan, complete all as specified and directed. |
| 109 | Supply and Fix Capacitor of 4 Mfd for exhaust fan, complete all as specified and directed. |
| 110 | Supply for replacement ceiling fan blade set of three heavy duty suitable for 1200/1400mm sweep of suitable approved make as direcetd by Engr-in-Charge. |
| 111 | Supply and Fix PVC canopy for ceiling fan 1200/1400mm sweep complete for various makes/model of fan, complete all as specified and directed. |
| 112 | Disconnecting and taking down exhaust fan and blades any size or sweep after dismantling and removal to trade workshop for repair, complete all as specified and directed. |
| 113 | M&L for Strip opening and cutting of old burnt copper winding of exhaust fan and rewinding of exhaust fan motor of sweep 450mm with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, re-assembling, testing and connecting for satisfactory run, complete all as specified and directed. |
| 114 | Description all as per ser item No 113.00 above, but of 300mm sweep. |
| 115 | Ball bearing of exhaust fan of any size/make as per the existing, complete all as specified and directed. Make: SKF/NBC or equivalent make. |
| 116 | Painting the exhaust fan including louvers of size 300/450mm sweep with two coats of synthetic enamel paint after cleaning and making the surface of oil/dust free, complete all as specified and directed. |
| 117 | Servicing of Geyser by disconnecting the electric and water supply connections, dismantling the geysers of any size, type & capacity and opening the top and bottom cover, thermostat, heating element, safety valve, vent pipe, separating inner & outer tank, removing glass wool insulation complete and keeping aside for re-use after de-scaling of inner tank by liquid chemical and with pressure water jet and assembling back the geyser including re-installation on wall with studs, nuts & bolts complete and testing after reconnecting electric and water connections, complete all as specified and directed. |
| 118 | Supply and fiixing Heating element for geyser of cap 1.5KW, AC 230 Volts, 50 Hz (as per sample), complete all as specified and directed. Make:- Micron/ Bajaj/ Havells |
| 119 | Supply and fixing Heating element for geyser of cap 2.0KW, AC 230 Volts, 50 Hz (as per sample), complete all as specified and directed. Make:- Micron/Bajaj/havells |
| 120 | Supply and fixing Thermostat for Geyser of capacity 25/35/50 ltr (long size) with temperature setting adjustment range from 40 to 85°C, ISI Marked, complete all as specified and directed. Make:- Philips/ Bajaj/ Venus |
| 121 | Geyser Syphon Assembly Set suitable for 25 ltr capacity geyser, fixed in replacement, complete all as specified and directed. |
| 122 | Description all as per ser item No 121.00 above, but for 35 Ltr capacity. |
| 123 | Description all as per ser item No 121.00 above, but for 50 Ltr capacity. |
| 124 | Rubber gasket for water heater storage type of any capacity fixed, in replacement and suitable as per the existing, complete all as specified and directed |
| 125 | Taking down old unserviceable plug top from geyser connection and Supply and Fixing in replacement plug top 15/16 Amps for Geyser, complete all as specified and directed. |
| 126 | PVC sheathed three core copper conductor flexible wire of size 2.5 Sqmm for connecting geyser, complete all as specified and directed. |
| 127 | Supply and fixing Sheet Metal Enclosure with socket, plug top and MCBs single pole and neutral enclosures with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 240 Volts, complete all as specified and directed. |
| 128 | Supply and replacement of safety valve for geyser of 25/35/50 litre capacity, complete all as specified and directed |
| 129 | Supply and replacement of non return valve 15mm dia for geyser of 25/50 litre capacity, complete all as specified and directed. |
| 130 | Supply and replacement of heavy duty PVC connector 600mm long 15mm dia with PTMT nut for geyser of 25/50 litre capacity, complete all as specified and directed. Make- Prayag |
| 131 | Disconnecting and taking out geyser of capacity 25 litre and replacement of SS inner tank and refilling of glass wool, refixing, connecting and testing, complete all as specified and directed. |
| 132 | Description all as per ser item No 131.00 above, but for 35 Ltr capacity. |
| 133 | Description all as per ser item No 131.00 above, but for 50 Ltr capacity. |
| 134 | Taking down old unserviceable and supply & fixing stop cock brass 15mm dia not less than 420 grams, complete all as specified and directed. |
| 135 | Preparation of surface of Geyser of capacity 25/35/50 Ltr by scarping, removing old paint etc and applying two coats of synthetic enamel paint over one coat of red oxide primer,complete all as specified and directed. |
| 136 | Supply and fixing of geyser Bolt 100 mm Long with nut & washers, complete all as specified and directed |
| 137 | Taking out the burnt/ unserviceable compressor from the refrigerator of 165 to 200 ltr capacity and supply & fixing the same as per the existing complete all as specified and directed. |
| 138 | Servicing and overhauling of refrigerator of 165 to 200 ltr capacity of various make and model incl transporting to workshop & back complete. |
| 139 | Replacement of thermostat for refrigerator of 165 to 200 ltr capacity. |
| 140 | Replacement of thermal relay for refrigerator of 165 to 200 ltr capacity. |
| 141 | Charging refrigerant R134A and testing for proper cooling and leakage complete for refrigerator/Acs of any capacity all as specified and directed. |
| 142 | Repair to unserviceable/burnt stabilizer of 3 KVA to 5 KVA capacity, rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, reassembling, replacement of knobs, LED's etc. and making fully functional on load as connected to Refrigerator/Deep freezer/AC, complete all specified and directed by Engr- in-charge. |
| 143 | Description all as per ser item No142.00 above,e but for stablizer of 1 KVA capacity. |
| 144 | Supply and fixing Sensor board suitable for water geyser 25/35 Ltr Capacity of Make Venus Model - 25 RD/35RD. |
| 145 | Disconnecting the electric supply from the mains, transporting the window/split type air conditioner capacity 1 ton/ 2 ton from original location to workshop to carry out the servicing complete and re-fixing at the original position after repairs and making the ACs fully functional and testing for satisfactory working, complete all as specified and directed. |
| 146 | Taking out old burnt/unserviceable compressor from the air conditioner 2 ton capacity and replacing the same as per the existing, re-fixing in position including testing for satisfactory working, complete all as specified and directed. |
| 147 | Supply and replacing as per existing AC blower motor suitable for 1.5/2 ton capacity air conditioner, complete all as specified and directed. |
| 148 | Supply and replacing thermostat suitable for 1.5/2 ton capacity air conditioner, complete all as specified and directed. Make:- Ranutrol / Sriram / Hitech / Classic |
| 149 | Supply and replacing running condenser 36 Mfd, complete all as specified and directed. Make:- Tesla / Sharda / Asian |
| 150 | Supply and replacing starting condenser 100/120 Mfd, complete all as specified and directed. Make:- Tesla / Sharda / Asian |
| 151 | Supply and replacing relay suitable for 1.5/2 ton capacity air conditioner, complete all as specified and directed. |
| 152 | Notes :- Amount of Credit Schedule for Schedule 'A' Part-ll shall be deducted from total quoted amount of BOQ to arrive at the contract sum Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail