| 1 | Excavating over areas, n exc 1.5 m deep and getting out in hard /dense soil. |
| 2 | Excavating over areas, exc 1.5 m deep and not exc 3.0m and getting out in hard / dense soil. |
| 3 | Excavating over areas, exc 3.0 m deep and not exc 4.50m and getting out in hard / dense soil. |
| 4 | Excavating over areas, exc 4.50 m deep and not exc 6.0m and getting out in hard / dense soil. |
| 5 | Excavating over areas, exc 6.0 m deep and not exc 7.5m and getting out in hard / dense soil. |
| 6 | Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out as in Hard/dense soil complete all as specified and as directed. |
| 7 | Excavation in trenches n exc 1.5 mtr wide and n. exc 1.5 mtr in depth in hard / dense soil for laying of GI/CI pipes and getting out in complete all as specified and directed. |
| 8 | Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in soft/loose soil getting out and levelling of bottom surface to required level for laying UG cable/errection of poles complete all as specified and directed by Engr-in-charge. FOR UG CABLE |
| 9 | Material and labour for plain cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in foundation and filling, mass concrete complete, all as specified and directed. |
| 10 | M&L formwork to sides of concrete foundation, footings, bases of coloumns, raft and raft bases, sides and soffits (if any) of foundation and plinth bearms and similar works vertical or to batter flat fair finished surfaces complete all as specified and as directed. |
| 11 | M&L formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, baluster, etc.; vertical or to batter complete all as specified and as directed. |
| 12 | M&L formwork to sofits of suspended slabs such as roof slabs, floor slab complete all as specified and directed. |
| 13 | M & L for mild steel TMT steel bars 10mm dia and over as in reinforcement cut to legth, bend to shape required incl crancking, bending spirally or hooping for columns hooking ends and biding with MS wire (annealed less than 0.9 mm dia) complete all as specified and directed. |
| 14 | M&L for RCC (Design Mix) M-30 grade using 20mm graded stone aggreagte as in foundations, incl rafts, footing, foundation beams, plinth beams, bases for coloumn, etc basement slabs under reamed piles and mass concrete using 20mm graded stone aggregate all as specified and directed. |
| 15 | M&L for RCC (Design Mix) M-30 grade using 20mm graded stone aggreagte as in wall, retaining walls, basement wall , ballast walls, and the like any thickness above top of footing incl attached pilasters and buttresses all as specified and directed. |
| 16 | M & L for RCC M-30 ( design mix) using 20 mm graded stone aggregate as in slabs supported on walls, beam and cloumn in floors, roofs and landing , balconies, canopies, deck slab and in selves complete all as specified and directed. |
| 17 | M&L for 10mm thick cement plaster with water proofing compound in cement mortar 1:3 on brick or concrete surfaces incl finishing surfaces even and smooth using extra cement complete all as specified and as directed.Note : Water proofing compound shall be measured and paid separetely. |
| 18 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 19 | Returning filling in excavated soil incl spreading levelling watering and well ramming in layer not exceeding 25 Cm thick complete all as specified and as directed. |
| 20 | Removing excavated material (soils) to a distance n.exc 50 m and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and directed. |
| 21 | S& F framed work such as grills, grating etc , framed work for ladder, railing, conforming to Fe290 Gde E-165 complete all as specified and as directed. |
| 22 | M&L for prepration of newly steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 23 | S & F for GI Pipe of heavy duty, 50mm dia, complete all as specified and directed. |
| 24 | M&L cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles complete all as specified and directed. |
| 25 | S & F for Chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165 |
| 26 | M & L for hardcore of broken stone boulders 75mm thick of guage exc 63mm but n exc 100mm deposited, spread and levelled in layers n exc 15 cm thick, watered and rolled, rammed to a true surface complete all as specified and as directed. |
| 27 | M & L for PCC 1:4:8 type D2 using 40mm graded crushed agg 75 mm thick over rammed earth as in sub base of hard standing complete all as specified and as directed. |
| 28 | Sand cushioning 40mm thick under paving blocks incl watering and consolidation complete all as specified and as directed. |
| 29 | Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade complate all as specified |
| 30 | Supply and lay pipe galvanized iron, 80 mm dia “Heavy class”, including fittings complete all as specified and directed by Engr in charge.(Note : Rate includes cost of laying, jointing etc) |
| 31 | Supply & laying 40 mm, 3 - Layers PP-R Polypropylene random copolymer) pipes SDR 7.4 (PN16) UV stablised antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fitting fixed complete all as specified and directed by Engr-in-charge.(Note : Rate includes cost of laying, jointing etc) |
| 32 | Supply & laying of 25 mm, 3 - Layers PP-R Polypropylene random copolymer) pipes SDR 7.4 (PN-16) stablised antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fitting fixed complete all as specified and directed by Engr in charge.(Note : Rate includes cost of laying, jointing etc) |
| 33 | Supply and fixing PP-R ball valves ( brass insert ) for 40 mm dia pipe as per requirement of the site all as specified and directed. |
| 34 | Supply and fixing PP-R ball valves ( brass insert ) for 25 mm dia pipe as per requirement of the site all as specified and directed. |
| 35 | Supply and fix Valves, Sluice, flanged of class 1.6 PN, 80mm dia as per requirement of the site all as specified and directed. |
| 36 | M&L for cutting existing GI /PPR/DI pipes/ and insertion of new Tee branches of suitable size to take branch connection of 40/25 mm dia PP-R. |
| 37 | Supply & fixing, testing and commissioning Submersible Pump, 5 HP (2WHP) electric driven, 415 Volt, 3 phase, 21 Mtr head complete with suitable motor, along with heavy-duty submersible flat cable 6 sqmm 3 core copper conductor for connection from Submersible Pump to Starter (Approx length 40 mtr), including Direct online starter submersible pump controller, 3 phase, 5 HP, having maximum operational current 9.52 Amp, contrator AC3 (A)-20 Amp, over load relay 8.9 Amp-13.5 Amp , IP 54 protection, SPP with auto manual switch, FRLS (Fire retardant low smoke) Internal wiring, Combined V / A meter, Voltmeter selector switch, ON OFF indication complete all as specified and directed by Engr in Charge. |
| 38 | Construction of stone masonary valve pit chamber of size 600 MM x 600 MM x 600 MM (internal dimension) including all necessary excavation and earth work in hard / dense soil and disposal of surplus soil to a distance not exceeding 50 meters & deposting the same as directed including PCC in foundation of the mixture (1:4:8) D-2 stone masonary in cement motor 1:4, rendering 15mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externally as the work proceeds in the same mortar as of stone masonary including mild steel frame (made out of angle in 40x40x6mm) MS steel cover 3.15 mm thick with handle and locking arrangement with hinges angle iron flat as required at site including painting of all posed MS work with two coat of synthetic enamel paint over a coat of red oxide primer and painting all the steel surfaces embedded in PCC with two coats of black bituminuos paint and all other relevant work complete. (FOR 40MM PPR VALVE ) |
| 39 | Construction of stone masonary valve pit chamber of size 900 MM x 900 MM x 900 MM (internal dimension) including all necessary excavation and earth work in hard / dense soil and disposal of surplus soil to a distance not exceeding 50 meters & deposting the same as directed including PCC in foundation of the mixture (1:4:8) D-2 stone masonary in cement motor 1:4 rendering 15mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externally as the work proceeds in the same mortar as of stone masonary including mild steel frame (made out of angle in 40x40x6mm) MS steel cover 3.15 mm thick with handle and locking arrangement with ginges angle iron flat as required at site including painting of all posed MS work with two coat of synthetic enamel paint over a coat of red oxide primer and painting all the steel surfaces embedded in PCC with two coats of black bituminuos paint and all other relevant work complete. (80 MM VALVE) |
| 40 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and as directed by the Engineer - in - Charge. |
| 41 | Supplying & Laying in trenches Clear Sand/m- Sand for cushioning under ground cable 8 cm below and 15 cm above complete all as specified and directed by Engr-in-charge. Note: Punned thickness only will be measured and paid. FOR UG CABLE |
| 42 | Supplying & Laying precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm in trenches for protect to under ground cable complete all as specified and directed by Engr-in-charge.FOR UG CABLE Please Enable Macros to View BoQ information |
| 43 | Supplying & Laying precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm in trenches for protect to under ground cable complete all as specified and directed by Engr-in-charge.FOR UG CABLE Please Enable Macros to View BoQ information |