| 1 | Note 1: (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum/amendments and general condition of contracts before entry/quoting the rates.Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Fixed credit has been given in technical documents which shall be taken into account during acceptance of bid/tender. |
| 2 | Excavation in trenches not exc 1.5m in width and 1.5 m in depth and getting out excavated soil soft/loose soil. |
| 3 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25cm |
| 4 | Removing excavated material / soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 5 | Supply and lay River sand cushioning spreading levelling for cable trenches all as specified and directed (Punned thickness only shall be measured and paid) |
| 6 | Supply and laying well burnt bricks sub class 'B' in trenches for cable protection of U/G cable all as specified and directed by Engr-in-Charges. |
| 7 | Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 25 sqmm 3.5 core including taking down old cable complete all as specified. |
| 8 | Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 35 sqmm 3.5 core including taking down old cable complete all as specified. |
| 9 | Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 50 sqmm 3.5 core including taking down old cable complete all as specified. |
| 10 | Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 70 sqmm 3.5 core including taking down old cable complete all as specified. |
| 11 | Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 95 sqmm 3.5 core including taking down old cable complete all as specified. |
| 12 | Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 150 sqmm 3.5 core including taking down old cable complete all as specified. |
| 13 | Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 185 sqmm 3.5 core including taking down old cable complete all as specified. |
| 14 | S & L GI pipe 50mm dia light grade in trenches /fixed on walls by suitable clamps and jointing complete all as specified. |
| 15 | S & L GI pipe 80mm dia light grade in trenches /fixed on walls by suitable clamps and jointing complete all as specified. |
| 16 | S & L GI pipe 100mm dia light grade in trenches /fixed on walls by suitable clamps and jointing complete all as specified. |
| 17 | Boring/Drilling (Horizontally) manually/mechanically under existing road (Maximum 10 M in width) suitable for passing GI tubing of 40 to 80 mm bore complete all as specified. |
| 18 | M&L for painting of erected steel tubular swaged poles of LT over head line (Except embedded protion), 9 M long complete including all MS mounted/fixed with pole, earth protection & water pipe (if exists) with one coat of aluminium paint and providing 07 Nos bands/ straps with synthetic enamel paint (black and yellow 30 cm wide each) from top of plinth block and numbering of poles with black synthetic enamel paint on circular yellow background of complete all specified. |
| 19 | M&L danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps bolt and nuts of approved size, for HT 25x20 cm size including dismantling unserviceable one, complete all as specified and as directed . |
| 20 | Road cutting for passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable complete all as specified and directed |
| 21 | M&L for Cleaning of electric substation by uprooting unwanted grass, bushes and trimming of branches, surface dressing not exc.15cms deep in loose/soft soil to cut the grass,throne busehs and other any type of grass upto root level surrounding the installation and depositing the same at nearby garbage pit, refreshing and re-spreading aggregates inside the premises of sub station if any including cleaning of road/path/fencing etc, maintenance of transformer platform all as specified and directed. |
| 22 | M & L for writing letters and figures in white enamel of black Roman, Italic or Indian of 10 cm height including circular back ground with black enamel paint of two coats incl white circular border over steel/RCC surfaces of electric poles all as specified and directed. |
| 23 | S& F for GI earthing strip 25x4 mm with nut and bolts comoplete including taking down old one all as specified and directed by Engr- in- Charge |
| 24 | S&F of GI Strip ISI marked of size 32 x6 mm complete with nuts, bolts and washers,buried in ground including excavation complete all as specified and directed by Engr-in-Charge. |
| 25 | Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6.3 mm thick burried directly in ground( earth pit not less than 2.25 m deep below the normal groungnd level) with top edgee of the plate not less than 1.5m below normal GL connected to GI earth strip of size 25x4mm by means of bolts, nuts, check nuts washers of GI or steel all as shown in electrical plate No-3 of SSR Part I connected to machanery/equipments installed power house/sub station all as specified including testing on completion.Note No-1 the unit rate shall also include for excavation earth work in any type of soil PCC (1:3:6) type C1 pit RCC 1:2:4 type B-1 cover reinforced with 8 mm dia CTD bars @ 150mm C/C both ways funnel with 15mm bore GI watering pipe 20mm dia bore GI protection pipe wire mesh and copper lugs complete all as specified and directed. |
| 26 | Supply and fixing LED flood light 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp with lumen output not less than 15000.Make Surya cat No 150W GeNXT-L and equivlent to Havells/Bajaj/Philips/Surya |
| 27 | Supply, install, test & commissioning in replacement LT panel outdoor, floor mounted/pedestal type,cubical,self supported,CPRI approved make,front and rear openable , double door hinged type with locking arrangement and suitable ventilations on both sides with wire mesh, IP-65 protection, fabricated out of 3.15 mm CRCA sheet duly powdercoated,mounted/fixed on and including MS angle iron stand of 50cm height above ground,fabricated out of 50x50x6 mm thick MS angles duly painted with black enamel synthetic paintover a red oxide primer duly grouted in PCC1:3:6 foundation,control wiring copper stranded PVC insulated FRLS cables not less than 1.5sqmm, interconnection of suitable size/capacity of copper strips for switch gear connection from main bus bar four run inculding earth bus strip of 500A capacity for entire length of panel ,suitable size of MS gland with gland plate and alluminium lugs/thimbles for all incoming/out going cables etc.complete and including taking down the old panel and accommodating the followings:INCOMING(i) MCCB 4 Pole 250 Amps, 415 volts - 01 NoOutgoing:(i) MCCB 4 Pole 160 Amps, 415 volts - 01 Nos, (ii) MCCB 4 Pole 100 Amps, 415 volts - 03 Nos, (iii) Digital type voltmeter panel mounted in built selector switch complete. 01 Setsiv) Digital type Ammeter panel mounted in built selector switch and suitable CTS complete. 1 Setsv) LED Indicator lamp of suitable size for RYB, 230 volts - 01 Set.vi) Panel wiring with suitable size PVC insulated heavy duty 1100 volts grade single core cable with copper conductor multistranded with cable end termination lugs. |
| 28 | Supply, install, testing & commissioning in replacement of LT busbar chamber of size (0.60x0.60x1.0)m CPRI approved, outdoor type, factory made fabircated to CRCA sheet of 3.15 mm thickness, angle iron of size 50X50X6mm thick of length 0.6 m from pcc, frame work and tee section (frame) of suitable size double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Al bus bar chamber (enclosed) incl rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold, nuts and washer and making complete including PCC foundation comprising of following accessories:- BUS-BAR & INTERNAL CONNECTIONS with a MCCB of 100 amp capacity ,4P with ICS=ICU=100%-1Nos. The bus-bars shall be made up of 04 Nos Aluminium 300 A rated not less than 60mmx10 mm, duly insulated with 1100 V grade standard colour coded PVC sleeves |
| 29 | S & F in replacement Moulded Case Circuit Breaker(MCCB),250Amps 25KA,4P,415V,50 Hz,Adjustable Thermal & Fixed magnetic type Conforms to IS13947-2 & IEC-60947-2 Ics=100%Icu as per IEC 60947-II,Adjustable Overload setting Ir=[0.8 to 1.0] xIn all as per specified & directed by Eng-in-Charge. |
| 30 | Same As Item No 29 here above,but for 200 Amps |
| 31 | Same As Item No 29 here above,but for 160 Amps |
| 32 | Supply and fixing LED flood light in replacement 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.Make: Havells/Phillips/Crompton/Surya. Please Enable Macros to View BoQ information |