| 1 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 150 Sqmm 3.5 core as per IS 7092 Pt -I including connection with suitable size of aluminium lug/thimble and taking out old u/s existing LT cable complete all as specified and directed. |
| 2 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 70Sqmm 3.5 core as per IS 7092 Pt -I including connection with suitable size of aluminium lug/thimble and taking out old u/s existing LT cable complete all as specified and directed. |
| 3 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 50 Sqmm 3.5 core as per IS 7092 Pt -I including connection with suitable size of aluminium lug/thimble and taking out old u/s existing LT cable complete all as specified and directed. |
| 4 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 16 Sqmm 4 core as per IS 7092 Pt -I including connection with suitable size of aluminium lug/thimble and taking out old u/s existing LT cable complete all as specified and directed. |
| 5 | M&L for cutting of road up to 0.75 m deep suitable for laying underground cables/MS tubes of any size/dia including GI pipe of 50 mm dia & making good the disturbed area to match with the existing level with cement concrete including removing the surplus soil to a distance upto 50 mtr complete all as specified and directed. |
| 6 | M&L for excavation in trenches in soft/loose soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out complete all as specified and as directed. |
| 7 | M&L for excavation in trenches in any type of soil not exc 1.5 mtrs wide and exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out complete all as specified and as directed. |
| 8 | M&L for returning filling in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed. |
| 9 | M&L for removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed. |
| 10 | Material and labour for Double wall corrugated HDPE pipe,PN-10 ISI marked of outer dia 63mm, inner dia 50 mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts including taking down of u/s existing HDPE pipes complete all as specified and directed by Engineer-in-Charge. |
| 11 | Material and labour for Double wall corrugated HDPE pipe,PN-10 ISI marked of outer dia 90 mm, inner dia 75 mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts including taking down of u/s existing HDPE pipes complete all as specified and directed by Engineer-in-Charge. |
| 12 | M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete for poles all as specified and directed by Engr-in-Charge. |
| 13 | M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete including form work for poles all as specified and directed by Engr-in-Charge. |
| 14 | M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in coping etc including form work for poles all as specified and directed by Engr-in-Charge. |
| 15 | M&L for steel tubing galvanised, light grade complete with fittings laid in trenches/ fixed along with poles etc as protection to cables of size 50 mm dia bore complete all as specified and as directed. |
| 16 | S&F in replacement of off load change over TPN 415 volts, 50 Hz of capacity 100 Amps including taking down old unserviceable existing change over complete all as specified and as directed. |
| 17 | S&F in replacement of new generation energy saving and environmental friendly long life LED street light made up of innovative die cast aluminium housing high power LED as lighting source toughened galss with IP - 65 power consumption 70/72 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) including pvc coated twisted copper cable 1.5 sqmm 3 core through copper connectors from junction box to security lights complete all as specified and directed. Make- Bajaj/Havells/Phillips/CG/Wipro/Helonix |
| 18 | S&F in replacement of new generation energy saving and environmental friendly long life LED street light made up of innovative die cast aluminium housing high power LED as lighting source toughened galss with IP - 65 power consumption 90 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) including pvc coated twisted copper cable 1.5 sqmm 3 core through copper connectors from junction box to security lights complete all as specified and directed. Make- Bajaj/Havells/Phillips/CG/Wipro/Helonix |
| 19 | S&F in replacement of new generation energy saving and environmental friendly long life LED flood light made up of innovative die cast aluminium housing high power LED as lighting source toughened galss with IP - 66 power consumption 100 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) including pvc coated twisted copper cable 1.5 sqmm 3 core through copper connectors as requirement at site complete all as specified and directed. Make- Bajaj/Havells/Phillips/CG/Wipro/Helonix |
| 20 | Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP-31) 9.0 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint incl taking down complete all as specified and directed. (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed.) Note :- Excavation incl earth work and PCC foundation will be measured and paid separately. |
| 21 | S & F of GI brackets for street light fitting fabricated with GI tubing 32 mm dia for LED Street lights medium grade 1.2 mtr length and bending to angle of 120 degree incl mild steel flat iron clamp fabricated with mild steel flat iron 32 x 5 mm with nut, bolt & washers suitable for fixing of GI bracket complete all as specified and directed. |
| 22 | S&F of kiosk box for luminaires ,weather proof made out of PVC/HDPE/FRP housing fire retardant, non fusing, shock & rust proof, single piece moulded and cover with hinged door, pole mounting type comprising of copper connector 4 nos of 16 Amps with 6 Amp MCB single pole , of minimum size 300x200x125mm, IP 66 fixed on pole with MS, clamps 30x5mm with necessary nuts, washer and incl. applying two coats of synthetic enamel paint over a red oxide primer on steel surface/clamps and embossing/painting of Danger sign of size not less than 10cms x 7.5cms with letter and conventional skull and bones in single red color on front face of kiosk box complete all as directed |
| 23 | S&F of kiosk box for luminaires ,weather proof made out of PVC/HDPE/FRP housing fire retardant, non fusing, shock & rust proof, single piece moulded and cover with hinged door, pole mounting type comprising of copper connector 4 nos of 16 Amps with 6 Amp MCB single pole , of minimum size 300x200x125mm, IP 66 fixed on pole with MS, clamps 30x5mm with necessary nuts, washer and incl. applying two coats of synthetic enamel paint over a red oxide primer on steel surface/clamps and embossing/painting of Danger sign of size not less than 10cms x 7.5cms with letter and conventional skull and bones in single red color on front face of kiosk box complete all as directed |