| 1 | Dismantling and taking down carefully flood light, street light /perimeter lighting luminaries from its position of any size/wattage from over head line poles or from elevated sentry post for carrying out repair/replacement of burnt/worn out accessories and removing unserviceable items from site and depositing to MES store yard at Nagrota and refixing back after replacing of worn out/unserviceable items including testing complete all as specified and directed,Note :- (a) The rate includes the labour item for replacement of Drivers, LED chips and cables and material shall be paid under relevant item of schedule. (b) Minor items like cotton waste, screws, nut bolts, insulation tapes are provided by the contractor and are included in the item rate only. (c) The contractor is responsible for to collect daily complaints and rectify the complaints with in 24 hrs. (d) The contractor shall responsible to provide tools, safety equipements, T&P items for team worked under him and safety of the team is under the Contractor only. |
| 2 | Supply only in replacement of old burnt driver with high performance driver with built in surge , over voltage, open/short circuit protection for longer life,suitable for followning LED security light/Flood light fitting of 25 to 60 W capacity complete all as specified and directed. |
| 3 | Supply only in replacement of old burnt driver with high performance driver with built in surge , over voltage, open/short circuit protection for longer life,suitable for followning LED security light/Flood light fitting of 70 to 100 W capacity complete all as specified and directed. |
| 4 | Supply only in replacement of old burnt driver with high performance driver with built in surge , over voltage, open/short circuit protection for longer life,suitable for followning LED security light/Flood light fitting of 120 to 180 W capacity complete all as specified and directed. |
| 5 | Supply only in replacement of unsv LED Chips (1.5W per LED) (Light source) getting efficiency :120 lumens/watt suitable for followning LED security light/Flood light fitting of 25 to 60 W capacity complete all as specified and directed. |
| 6 | Supply only in replacement of unsv LED Chips (1.5W per LED) (Light source) getting efficiency :120 lumens/watt suitable for followning LED security light/Flood light fitting of 70 to 100 W capacity complete all as specified and directed. |
| 7 | Supply only in replacement of unsv LED Chips (1.5W per LED) (Light source) getting efficiency :120 lumens/watt suitable for followning LED security light/Flood light fitting of 120 to 180 W capacity complete all as specified and directed. |
| 8 | Supply and fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street light based on LUX level of nature light having ON ≤ 30 lux and OFF ≥ 10 Lux . The sensor (Nature Switch) along with suitable power contactor , MCB and support termianl should be enclosure made of rust proof, electric shock proof , termite proof and FR grade SMC junction box(sintex make) conforming to confirmining IS 13947.4-1 & IS 8828, IP 66 including contactors ( 3 Nos each) and incoming- ourgoing MCBs ( 3 Nos each) rating of 25-40 amp and Circuit copper wiring of min 10 Sqmm cable incl taking down old unsv complete all as specified and directed. |
| 9 | S&F in repair LED street light fitting of capacity 45W of epoxy powder coated pressure die cast aluminium housing with toughened glass with Lens delivering (efficiency) : 120 lumens/ watt, and high performance driver with built in surge , over voltage, open/short circuit protection for longer life, IP-66 protection, 50000 burning hours including making connection with two core PVC insulated and sheathed copper conductor cable of size 1.00 sqmm complete all as specified and directed. Note :- Contractor shall be submitted the warranty cert (Purchase Voucher) for 02 years before payment |
| 10 | S&F in repair LED street light fitting of capacity 60W of epoxy powder coated pressure die cast aluminium housing with toughened glass with Lens delivering (efficiency) : 120 lumens/ watt and high performance driver with built in surge , over voltage, open/short circuit protection for longer life, IP-66 protection, 50000 burning hours including making connection with two core PVC insulated and sheathed copper conductor cable of size 1.00 sqmm complete all as specified and directed. Note :- Contractor shall be submitted the warranty cert (Purchase Voucher) for 02 years before payment |
| 11 | S&F in repair LED street light fitting of capacity 90W of epoxy powder coated pressure die cast aluminium housing with toughened glass, Lens delivering (efficiency) : 120 lumens/ watt and high performance driver with built in surge , over voltage, open/short circuit protection for longer life, IP-66 protection, 50000 burning hours including making connection with two core PVC insulated and sheathed copper conductor cable of size 1.00 sqmm complete all as specified and directed. Note :- Contractor shall be submitted the warranty cert (Purchase Voucher) for 02 years before payment |
| 12 | S&F in repair LED street light fitting of capacity 120W of epoxy powder coated pressure die cast aluminium housing with toughened glass, Lens delivering (efficiency) : 120 lumens/ watt and high performance driver with built in surge , over voltage, open/short circuit protection for longer life, IP-66 protection, 50000 burning hours including making connection with two core PVC insulated and sheathed copper conductor cable of size 1.00 sqmm complete all as specified and directed. Note :- Contractor shall be submitted the warranty cert (Purchase Voucher) for 02 years before payment |
| 13 | S&F of in repair of LED flood light capacity 120W of epoxy powder coated pressure die cast aluminium housing with toughened glass, Lens delivering (efficiency) : 120 lumens/ watt and high performance driver with built in surge , over voltage, open/short circuit protection for longer life, IP-66 protection, 50000 burning hours including making connection with two core PVC insulated and sheathed copper conductor cable of size 1.00 sqmm complete all as specified and directed. Note :- Contractor shall be submitted the warranty cert (Purchase Voucher) for 02 years before payment |
| 14 | Supply and fixing Junction box made of SMC/FRP sheet ready made of size 300 mm x 200 x 105 mm having 100 A Capacity RYB and neutral aluminium bus bar of 3 mm thick duly fitted on suitable insulator, and MCB SP 6 A 10 KA 240V -01 No. with fixing arrangement fixed properly to pole/fixed on wall with MS Clamps 25x5 mm and nut and bolts complete all as specified and directed. |
| 15 | Supply & Fix street light brackets fabricated out of medium grade GI pipe of 40 mm dia, 1.5mtr long bent to shape suitable for street light fittings with two sets of clamps made out of mild steel flat iron suitable for fixing on HT/LT poles with nuts, bolts and washers all as directed including dismantling the existing brackets etc complete all as specified and directed. |
| 16 | S & F in repair MCB TPN 16- 32 Amp 415 volts 50 Hz AC 10 KA, C Series with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified and directed. |
| 17 | S & F in repair MCB SPN 6-32 Amp 230 volts 50 Hz AC 10 KA , C Series with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified and directed. |
| 18 | S & F in repair MCB SP 6-32 Amp, 230 volts 50 Hz AC 10 KA, 'C' Series with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified and directed. |
| 19 | S & L in repair Cable XLPE insulated screened PVC bedded galvanized steel strip wire armoured electric power cables heavy duty with stranded aluminium conductor,1100 volts grade,cross sectional area 35 Sqmm x 3.5 Core complete all as specified and directed. |
| 20 | All as per ser No 19 but cable size 25 Sqmm 4 core |
| 21 | All as per ser No 19 but Cable size 16 Sqmm 4 core |
| 22 | All as per ser No 19 but Cable size 10 Sqmm 4 core |
| 23 | Excavating in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in soft/loose soil complete all as specified and directed. |
| 24 | Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed. |
| 25 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 26 | Sand cushioning with fine dry unwashed sand in trenches for protection of cables complete all as specified and directed. |
| 27 | Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat complete all as specified and directed. |
| 28 | Supply and fixing in repair PVC insulated and sheathed aluminium conductor cable of size 2 Core 4 Sqmm complete all as specified and directed. |
| 29 | Supply and fixing in repair PVC insulated and sheathed aluminium conductor cable of size 2 core 6 Sqmm complete all as specified and directed. |
| 30 | Supply and fixing in repair PVC insulated and sheathed aluminium conductor cable of size 2 core 10 Sqmm complete all as specified and directed. |
| 31 | Supply and fixing in repair PVC insulated and sheathed aluminium conductor cable of size 2 core 16 Sqmm complete all as specified and directed. |
| 32 | Supply and fixing in repair PVC insulated and sheathed copper conductor cable of size 2C x1.00 sqmm complete all as specified and directed. |
| 33 | Supply and fixing in repair Day/night auto on/off photo cell sensor, 220-240 V AC, 50 Hz , 6Amps, pole mounted type, light switch suitable for street lights up to 20 numbers complete with clamps and testing complete all as specified and directed. Please Enable Macros to View BoQ information |