| 1 | M & L for Cleaning/clearing of sewage line (including manholes except 1st manhole) 100mm to 350mm bore of any description under ground any depth, removing any type of blockage including desilting, descaling and de-chocking from drain with combined high pressure water jetting cum suction (vacuum) type machine mounted on LMV/HMV having facility of high pressure vacuum including provision of hydraulic application through high pressure thermoplastic fiber based water jetting hose and through conical round shaped nozzle pipe and flushing after cleaning including clearing of manhole, sludge water shall be disposed of directed including taking of manhole cover and re-fixing the same after cleaning complete all as specified and directed. |
| 2 | M & L for Dewatering/Desludging & cleaning of manhole of any depth, any size, taking out water mixed with sludge and solid sludge including any foreign materials such as stones, tree hedges etc, removing and depositing sludge at a distance not less than 20 meter in a ditch including necessary excavation of pits and covering with earth & spraying unslaked lime on the covered ditch as well as around the manholes to make hygienic including necessary flushing of manholes with water after desludging complete all as specified and directed. |
| 3 | Taking out/Pumping out contaminated sewage water from septic tank/soakage well including inlet/outlet chamber after plugging incoming sewage line through combined high pressure water jetting cum suction (vaccum) type machine mounted on HCV Honey succer vehicle of capacity not less than 6000 ltrs each and facility of high pressure vaccum and removing off the same in the pit to a place a complete all as specified and directed. Note: (i) One lorry unit will be considered for full load of 6000ltrs irrespective of taking out.(ii) The details of HCV Honey succer vehicle eg. registration number, owner name & driver name will be maintain in register to be kept on charge of JE and the number of trips each day made by the vehicle will be entered in register duly signed by contractor, JE & Engr-in-Charge. This register will be checked by JE (QS&C) during the tech check of RAR/Final bill. |
| 4 | M & L for Desludging the solid sludge from septic tank, soakage well including inlet/outlet chamber, removing out all scum, silt reduce sludge (both organic/inorganic nature) after plugging the incoming sewage line through combined high pressure water jetting cum suction (vacuum) type machine mounted on LMV/HMV and facility of high pressure vacuum and removing and dumping off the same in the tank to a place out side cantonment at the place marked for the purpose by local municipality or area controlling authority complete all as specified and directed.Note: (i) One lorry unit will be considered for full load of 6000ltrs irrespective of taking out.(ii) The details of HCV Honey succer vehicle eg. registration number, owner name & driver name will be maintain in register to be kept on charge of JE and the number of trips each day made by the vehicle will be entered in register duly signed by contractor, JE & Engr-in-Charge. This register will be checked by JE (QS&C) during the tech check of RAR/Final bill. |
| 5 | M & L for Cleaning of soil waste pipe (cast iron/PVC/SGSW/DWCP )150/200mm bore laid in ground any slope or gradient and depth 3 mtr by roding taking out all residue from the lines/manholes including water and depositing at a distance not less than 20 mtr in ditch finally covering the ditch with earth and spraying unslacked lime on the covered ditch as well as around the manholes to make hygienic including excavation of ditch testing of line by flushing water after cleaning etc complete all as specified and directed |
| 6 | M & L for Cleaning/clearing of IWC/ EWC, gully trap /floor trap including CI pipe / PVC pipe upto first manhole by roding, taking out all residue including waste and testing by pouring water after cleaning etc complete all as specified and directed by Engr-in-Charge. (Note: Cleaning of PVC/CI pipe from first floor / ground floor embedded in floor or fixed to wall included in this item) complete all as specified and directed. |
| 7 | M & L for Cast iron oval access covers / inspection cover with bolts rubber gasket to make it water tight for 75mm/100mm bore CI fittings including taking out broken/ unserviceable cover with bolts etc and removing from site complete all as specified and directed. |
| 8 | Taking down cement plaster on brick or stone wall etc including racking out joints, hacking for key scrubbing down with water etc to receive new plaster etc. complete all as specified and as directed. |
| 9 | M&L for Rendering 15mm thick in two layers [base layer 10mm in CM 1:4 & finishing layer 5mm thick in cement mortar (1:4)] using water proofing compound in 2nd layer only on brick work or concrete surfaces of wall, surfaces finished even and smooth using extra cement complete all as specified & directed.Note : WPC shall be measured and paid separately |
| 10 | Supply only liquid water proofing compound complete all as specified and directed. |
| 11 | Demolition and breaking up 150mm dia drain pipes (Salt glazed ware, AC or reinforced concrete ) and set in cement mortarcomplete all as specified and directed. |
| 12 | Demolition and breaking up 200 mm dia drain pipes (Salt glazed ware, AC or reinforced concrete ) and set in cement mortar complete all as specified and directed. |
| 13 | Demolition and breaking up 250 mm dia drain pipes (Salt glazed ware, AC or reinforced concrete ) and set in cement mortar complete all as specified and directed. |
| 14 | M & L for Concrete bed to drain pipes laid in trenches including packing under and haunching against the sides of pipes aftaer they are laid and tested in cement concrete 1:4:8 type D-2, using 40mm graded crushed stone aggregate for 150mm bore pipe, complete all as specified and as directed |
| 15 | M & L for Concrete bed to drain pipes laid in trenches including packing under and haunching against the sides of pipes aftaer they are laid and tested in cement concrete 1:4:8 type D-2, using 40mm graded crushed stone aggregate for 200mm bore pipe, complete all as specified and as directed |
| 16 | M & L for Concrete bed to drain pipes laid in trenches including packing under and haunching against the sides of pipes aftaer they are laid and tested in cement concrete 1:4:8 type D-2, using 40mm graded crushed stone aggregate for 250mm bore pipe, complete all as specified and as directed |
| 17 | M & L for Salt -Glazed stoneware drain pipes 150 mm dia laind in trenches and jointed complete all as spd and directed |
| 18 | M & L for 150mm Bore / inner dia double wall, corrugated HDPE Pipe (SNB) (ISI Marked) with integral socket & necessary fitting jointing as directed & laid in trenches complete all as specified and directed |
| 19 | M & L for 200mm Bore / inner dia double wall, corrugated HDPE Pipe (SNB) (ISI Marked) with integral socket & necessary fitting jointing as directed & laid in trenches complete all as specified and directed |
| 20 | M&L for 200mm bore dia reinforced cement concrete pipes, class NP-2, laid and jointed complete with collars, complete all as specified and directed. |
| 21 | M & L for 250mm Bore / inner dia double wall, corrugated HDPE Pipe (SNB) (ISI Marked) with integral socket & necessary fitting jointing as directed & laid in trenches complete all as specified and directed |
| 22 | M & L for Cutting into existing manhole for connecting new drains and making good to pipes and rendering cutting out existing benching for and forming branching for and forming branch channel (1/2 round or ¼ section ) in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate smooth finished and reforming benching as specified and directed for 150mm dia of pipe complete all as specified and directed. |
| 23 | M & L for Cutting into existing manhole for connecting new drains and making good to pipes and rendering cutting out existing benching for and forming branching for and forming branch channel (1/2 round or ¼ section ) in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate smooth finished and reforming benching as specified and directed for 200mm dia of pipe complete all as specified and directed. |
| 24 | M & L for Cutting into existing manhole for connecting new drains and making good to pipes and rendering cutting out existing benching for and forming branching for and forming branch channel (1/2 round or ¼ section ) in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate smooth finished and reforming benching as specified and directed for 250mm dia of pipe complete all as specified and directed. |
| 25 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 26 | M & L for Glazed ceramic colored tiles 600mmx300mmx 6 to 7mm thick/450mm x300 mm x 7mm,300x200x7mm thick as in patches in vertical surfaces such as dado, skirting, wall etc set & jointed in neat cement slurry and pointed with coloured cement to match with tiles in over and including 10mm thick cement plaster in cement mortar 1:4. complete all as specified and directed. |
| 27 | S&F Non-skid ceramic coloured tiles 7 to 8mm thick area of each tile exceeding 0.11sqm but n exc 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed or beddding layer of CM 1:6 including complete all as specified and directed. |
| 28 | Excavation in trenches in any type of soil not exceeding 1.5m wide and not exceeding 1.5m wide for foundation etc or for shaft, wells, cesspits, manhole, pair house etc not exceeding 10 Sqm on plan and not exceeding 1.5 m depth and getting out in any type of soil complete all as specified and directed. |
| 29 | Returning filling in including, spreading, leveling watering and well ramming in layer not exceeding 25cm in each layer complete all as specified and directed. |
| 30 | Removing excavated material not exceeding 50 M and depositing where directed at level not exceeding 1.5m above the starting pointing complete all as specified and directed. |
| 31 | M & L for Plain cement concrete 1:4:8 as in foundation type D-2 (using 40mm graded crushed stone aggregate) as in fdn filling or mass concrete complete all as specified and directed. |
| 32 | M & L for Plain cement concrete 1:2:4 type B-1( using 20mm graded aggregate) as in benching, coping including watering slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed. |
| 33 | Demolition of brick work or stone masonry, built in CM including all quoins, arches, pillars etc. but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and directed. |
| 34 | M & L for Brick work with sub class B (old size) brick straight or curved on plan exc 6 m mean radius in CM 1:4 complete all as specified and directed. |
| 35 | All as item no 34 above but except bricks complete all as specified and directed. |
| 36 | M & L for cement concrete 1:2:4 type B-1( using 20mm graded crushed stone aggregate) as in benching, bed plates, coping including watering slightly rounded or chamfered angles, incl necessary form work and finishing all exposed to surface complete all as specified and directed. |
| 37 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for reinforcement cut as required to facilitate demolition, complete all as specified and directed |
| 38 | M & L for TMT mild steel bars 10MM dia and over cut to length bent to shape required including cranking bending spirally for hoping for columns, hooking ends and binding with and including mild steel wire annealed 0.9 mm dia or securing with clips all as specified and directed. |
| 39 | M & L for Mild Steel TMT bars 6 to 8 mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and directed. |
| 40 | S & F Mild steel work small article such as MS rungs to shape as required Plain head, lost head, lath, mild steel wire nails, bright finished upto 50mm thick complete all as specified and directed. |
| 41 | M & L for providing RCC 1:1.5:3 for septic tanks slabs complete all as specified & directed. |
| 42 | M & L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick complete all as specified and directed. |
| 43 | M & L for Precast cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in manhole/drain slab cover all as specified and set in CM 1:4 complete all as specified and directed. |
| 44 | S & F in Vitreous china squatting pan “Orrisa” pattern of size 580mm “White” with 'P' or 'S' Trapfront or back inlet and foot rests, any pattern (excluding flushing cistern and flush pipe), connection to trap and to flushing pipe anti- syphonage pipe etc complete making good complete all as specified and directed. |
| 45 | S & F Vitreous china wash down closet pan (Pedestal pattern) white with ‘S’&'P' trap plastic seat cover white including connection to out going pipe & to flushing pipe, anti syphonage pipe including making good to floor and fix in repairs etc complete all as specified and directed |
| 46 | S & F in repair Vitreous china premium/1st quality wash down water closet wall hung EWC white/ivory/off white (closed pattern incl all necessary accessories like rag bolts/gel gasket etc. (excluding flushing cistern & flush pipe) complete all as specified and directed |
| 47 | S & F in repairs, PVC valve less symphonic action type, flushing cistern, low level, white of capacity 10 ltrs with inlet , ball valve, float and and fixing arrangement ccomplete all as specified and as directed. |
| 48 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for like MH cover, bdrain pipe bed, hard standing etc complete all as specified. |
| 49 | M & L for 75mm thick PCC 1:3:6 Type B2 ( 40 mm graded aggregsate) as in subbase and pavings etc complete all as specified and directed |
| 50 | M & L for Chequered cement concrete tiles of size 30cm x 30cm x 20 to 22 mm thick glossy finish coloured and pattern in patches in floor with set & jointed in neat cement slurry and pointed in coloured cement to match the tiles laid over with grey cement and no pigment incl 15mm thick screed screed bedding in cement mortar 1:6 complete all as specified and directed. |
| 51 | Dismantling cast-iron/PVC pipes including fittings taking out of trenches or walls as required dia of pipe upto 100mm complete all as specified and directed |
| 52 | M & L for 100mm dia Cast iron pipes with flanged ends, centrifugally cast, class A, in any length laid in trenches complete all as specified and directed. |
| 53 | M & L for 75mm dia Cast iron pipes with flanged ends, centrifugally cast, class A, in any length laid in trenches complete all as specified and directed. |
| 54 | M & L for upto 150mm bore Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \\"Y\\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete all as specified and directed. |
| 55 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls for 110mm bore.complete all as specified and directed |
| 56 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls for 75mm bore.complete all as specified and directed |
| 57 | S&F PVC (SWR) bends of 110mm bore.complete all as specified and directed |
| 58 | S&F PVC (SWR) bends of 75 mm bore.complete all as specified and directed |
| 59 | S&F PVC (SWR) Branch Piece double equal or unequal of 110mm bore.complete all as specified and directed |
| 60 | S&F PVC (SWR) Branch Piece double equal or unequal of 75 mm bore complete all as specified and directed |
| 61 | S&F in repair stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays incl bolt and nuts securing ends of stays to wall or roof of 75mm bore complete all as specified and directed. |
| 62 | S&F in repair stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays incl bolt and nuts securing ends of stays to wall or roof of 100mm bore.complete all as specified and directed |
| 63 | S&F in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed |
| 64 | Provided M & L for cleaning of all types of blockage of Nahni traps/floor traps/bottle traps, blockages of WC's, rain water pipes and similar works complete all as specified and directed.Note :- 1. Labour shall be provided by the contractor on daily basis from 9:00 AM to 5:00 PM incl all Tools and Plants. Each labour shall intertain complaints everyday in working hours.2. The supervisor of Contactor shall take all complaints from the Complaint Cell and attend to all on the same day.3. Futher more, the feedback shall be given by the contractor/supervisor to concened JE from all aspect.4. Details of all the compliants attended shall be maintained in a register by contractor which will be signed by JE, Engr-in-Charge and contractor and the same will be produced alongwith RAR/FB. Please Enable Macros to View BoQ information |