| 1 | Demoliton of brick work/stone work built in cement mortar as in drain, manhole, septic tank and soak well complete all as specified and directed. |
| 2 | M & L Brickwork with fly ash bricks old size straight or curved on plan exc 6.0 M mean radius built in cement mortar 1: 6 as in Man hole/ drain complete all as specified and as directed. |
| 3 | Taking down cement plaster on brick or stone walls etc incl racking out joints hacking for key and scrabbing down with water etc. |
| 4 | M&L rendering 15 mm on brick/concrete surfaces fair faces in CM (1:4) finished surfaces even and smooth using extra cement and mixed with intergral water proofing compound (WPC),complete all as specified . Note: WPC shall be measured and paid separately under supply only item ) |
| 5 | Supply only intergral water proofing compound,complete all as specified. |
| 6 | Excavation in trenches not exceeding 1.50 m wide and not exceeding 1.5M in depth for sewage line, manhole etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and as directed. |
| 7 | ditto as per above item No 05, but exceeding 1.5 m and not exceeding 3.0 m in depth and getting out in any type of soil complete all as specified and as directed. |
| 8 | Returning, filling in, including spreading, watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and as directed. |
| 9 | Removing excavated material to a distance n exc 50M and deposited where directed at a level n. exc 1.5M above the starting point complete all as specified and as directed. |
| 10 | Demolition and breaking drain pipe 150 mm Internal dia (salt glazed stoneware) set in cement mortar including packing under and haunching against side of pipe complete all as specified and as directed. |
| 11 | Demolition and breaking drain pipe 200 mm Internal dia (salt glazed stoneware) set in cement mortar including packing under and haunching against side of pipecomplete all as specified and as directed. |
| 12 | M&L Reinforced concrete pipes 150 mm dia, class NP3, laid & jointed complete with collars complete all as specified and as directed. |
| 13 | M&L Reinforced concrete pipes 200 mm dia, class NP3, laid & jointed complete with collars complete all as specified and as directed. |
| 14 | M&L cement concrete bed to drain pipe 150 mm Internal dia of pipe including packing under and haunching against side of pipe after they are laid and tested in cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate complete all as specified and as directed. |
| 15 | M&L cement concrete bed to drain pipe 200 mm Internal dia of pipe including packing under and haunching against side of pipe after they are laid and tested in cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate complete all as specified and as directed. |
| 16 | Surface dressing n.exc 15cm deep including cleaning away grass vegetation saplings shrubs , bush wood, under growth roots and trees not exc 30cm girth including disposal of spoils , in soft /loose soil,complete all as specified and directed. |
| 17 | M&L PCC 1:3:6 type C-1 using 20 mm graded store aggregate as in benching/coping/surface channel /drains complete all as specified and as directed. |
| 18 | Demolition of cement concrete (reinforced) in ground floors and paving n. exc 15 cm thickness below or above ground level complete all as specified and as directed. |
| 19 | M&L precast re-inforced Cement Concrete 1:2:4 type B1 (using 20mm graded stone agg) as in cover slabs for man holes etc set in cement mortar 1:6 including necessary form work complete all as specified and directed |
| 20 | M&L RCC type B1 (1:2:4) using 20 mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 21 | S&F for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete, all specified and directed. |
| 22 | M&L for TMT bars 6 mm to 8 mm dia, cut to length, bent to shape reqd, including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and directed |
| 23 | M&L Stone slab 25 mm to 35 mm thick dressed true and square, in one length not less than 60 cm and n. exc 120 cm as in man hole cover etc., complete all as specified and as directed. |
| 24 | Desludging and dewatering of existing septic tank, soak wells of any description and depth including removing and refixing of sewer appurtenance required for safe disposal of sludge sullage and foreign materilas by mechanical means using hydraulic operated high pressure suction cum jetting sewer cleaning machine having jetting tank capacity of minimum 3500 Ltr and suction tank capacity of 300ltrs including skilled driver and operator and supervising Engineer including provision of water for jetting and removal of sludge/slit/liquid/mud and sand (in foul position) etc outside the MoD land/ premises at any distance and it should be disposed off at such place which is not determinated to public health including loading, unloading, digging out pit of any size in any type of soil, burring sludge/silt/spoil/mud etc. into the pit and spreying bleaching powder over the entire surface complete . |
| 25 | Cutting into existing manholes for connecting new drains,150 mm Bore ( Internal diameter ) making good to pipe and rendering, and reforming benching as required. Including removing existing branch drain, making good to walling and rendering , cutting out branch channel and making good benching ,,complete all as specified and directed. |
| 26 | Cutting into existing manholes for connecting new drains, 200 mm Bore ( Internal diameter ) making good to pipe and rendering, and reforming benching as required. Including removing existing branch drain, making good to walling and rendering , cutting out branch channel and making good benching ,,complete all as specified and directed. |
| 27 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 28 | M&L Cement concrete in foundations, filling and mass concrete 1:4:8 type D2 (using 40mm graded stone agg) complete all as specified and directed |
| 29 | M&L for 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed |
| 30 | Dismentling and refixing in required pattern of 60-80 mm thick paver block over and including 50mm thick compacted bed of fine sand finishing and sweeping extra sand complete all as specified and directed. |
| 31 | Dismantling of cast iron /PVC/RCC drain pipe up to 100mm dia , jointed in cement mortar complete all as specified and as directed. |
| 32 | S&F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed. |
| 33 | S&F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls. |
| 34 | S&F 75 mm bore PVC (SWR) bends of any radius complete all as specified and as directed. |
| 35 | S&F 75 mm bore PVC (SWR) bends of any radius with access door complete all as specified and as directed. |
| 36 | S&F 110 mm bore PVC (SWR) bends of any radius complete all as specified and as directed. |
| 37 | S&F 110 mm bore PVC (SWR) bends of any radius with access door complete all as specified and as directed. |
| 38 | S&F PVC (SWR) reducers of size 110 mm x75 mm complete all as specified and as directed. |
| 39 | S&F 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door complete all as specified and as directed. |
| 40 | S&F 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door complete all as specified and as directed. |
| 41 | S&F 75 mm bore PVC (SWR) Vent Cowl complete all as specified and as directed. |
| 42 | S&F in repair stack clamps out of 40mmx 3 mm flat iron and 12 mm dia round iron stamp including bolts and nuts and securing ends of stays to walls or roof for 100 mm pipe, complete all as specified and directed. |
| 43 | Ditto as per above item but 75 mm bore pipe complete all as specified and as directed. |
| 44 | M&L for applying two coats of white wash on wall surface including preparation of surface complete all as specified and as directed. |
| 45 | Cleaning and rodding the blocked sewage line either by mechanical (means using hydraulic operated high pressure suction cum jetting sewer cleaning machine including provision of water for jetting and removal of sludge/slit/liquid/mud and sand (in foul position) etc or manual of any size to any depth till the smooth flow of sewage line and washing down complete sewage line with water and removing and refixing manhole covers and rodding complete all as directed |
| 46 | Cleaning of manholes any size and depth including desludging and dewatering including removing and refixing of sewer appurtenance by mechanical /manual including provision of water for jetting and removal of sludge/slit/liquid/mud and sand (in foul position) etc, removing to a distance exceeding 100 meter but not exc. 250 metre and depositing in ditches including necessary excavation and earth work in soft/loose soil for making ditches after the sludge are deposited spreading and levelling of excavated soil in the ditches over the sludge and removing surplus soil to a distance exc 50 mtr and sprinkling bleaching powder (including supply of bleaching powder) over the area of ditches with one metre around ,complete all as specified and directed. |