| 1 | Taking down carefully UNSV copper/aluminium point wiring (light, fan, bell, power sockets) along with UNSV fittings/fixture such as switches, ceiling roses, pendants, regulators, sockets, electric fitting, light fittings and making good the disturbed surface complete all as specified and directed.Note: Serviceable fitting/fixtures shall be measured and paid separately. |
| 2 | Taking down carefully aluminium submain wiring with wooden battens / PVC surface conduit complete all as specified and directed. |
| 3 | Taking down distribution board/AC box of any size and any capacity and making good the disturbed surface complete all as specified and directed. |
| 4 | Material & labour for wiring with and including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping of suitable size as per site requirement (not less 32x12mm), medium grade, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box duly painted with one coat of bituminous black paint over a coat of red oxide paint with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. complete all as specified and directed for the following :-(a) One light point controlled by one switch. |
| 5 | All as per item No 4 above but one fan point controlled by one switch complete all as specified and directed by Engr in charge. |
| 6 | All as per item No 4 above but one call bell point controlled by one bell push switch complete all as specified and directed by Engr in charge. |
| 7 | All as per item No 4 above but one light point controlled by two, 2- way switches complete all as specified and directed by Engr in charge. |
| 8 | All as per item No 4 above but one socket outlet 5 Amp controlled by one switch on the same board complete all as specified and directed by Engr in charge. |
| 9 | All as per item No 4 above but one socket outlet 5 Amp controlled by one switch on the independant board complete all as specified and directed by Engr in charge. |
| 10 | Material & labour for wiring with and including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping, 32x12mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box duly painted with black bituminous paint over a coat of red oxide primer with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. complete all as specified and directed |
| 11 | Supply & fix, in repairs, sub-main wiring with 2 single core, 6 Sqmm PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper multi stranded conductor drawn in and including PVC casing and caping of 32mm size ISI marked MMS type including drawing one run of PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper conductor multi stranded, 6 Sqmm size as continuous earth wire drawn through and connected to main switch/DB and testing on completion complete all as specified and directed. Note: 2 runs of main conductor, one run of earth conductor and one run of PVC casing and caping shall be measured as one unit length |
| 12 | Supply & fix, in repairs, sub-main wiring with 2 single core, 4 Sqmm PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper multi stranded conductor drawn in and including PVC casing and caping of 32x12mm size, ISI marked Medum grade including drawing one run of PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper conductor multi stranded, 4 Sqmm size as continuous earth wire drawn through and connected to main switch/DB and testing on completion complete all as specified and directed. Note: 2 runs of main conductor, one run of earth conductor and one run of PVC casing and caping shall be measured as one unit length. |
| 13 | Supply & fix switch piano type flush, single pole, one way 6 A 230 V complete all as specified and directed. |
| 14 | Supply & fix switch piano type flush, single pole, two way 6 A 230 V complete all as specified and directed. |
| 15 | Supply & fix bell push switch piano type flush, single pole, one way 6 A 230 V complete all as specified and directed. |
| 16 | Supply & fix 2 in 1 Socket outlet w/o Shutter, 5 pin, 6 Amp, flush type, 230 V complete all as specified and directed. |
| 17 | Supply & fix Socket type Electronic Regulator Step type, 5 speed, 50 Hz, 230V complete all as specified and directed. |
| 18 | Supply & fix Switch type Electronic Regulator Step type, 5 speed, 50 Hz, 230V complete all as specified and directed. |
| 19 | Supply & fix, ceiling rose, 3 terminal , any shade, of PVC/Polycarbonate, isolated body complete all as specified and directed |
| 20 | Supply & fix only Angle/Batten lamp holder (Metal Ring) with back plate suitable for angle / batten fitting complete all as specified and directed. |
| 21 | Supply & fix in replacement of Angle/Batten lamp holder (Metal Ring) complete all as specified and directed by Engr in charge. |
| 22 | Supply & fixing for switch socket outlet combination (2/4 Hole) Ceramic , three pin, 15/ 16 Amps & three pin 5/6 Amps controlled by one switch, flush type, 20 volts complete all as specified & directed. |
| 23 | Supply & fixing for switch socket outlet combination with Box (02 Hole) Ceramic, three pin, 15/ 16 Amps & three pin 5/6 Amps controlled by one switch , flush type, 230 volts complete all as specified & directed. |
| 24 | Supply & fix call bell ding dong type 240 volt complete all as specified and directed. |
| 25 | Supply & fix in repairs LED tube light fitting of 20 watt, 6500 K, decorative ultra slim square profile LED lighting fixtures with extruded polycarbonate, environmental friendly, energy efficient complete all as specified and directed Make: HAVELLS Cat Part No LHEXAWP7IN1W020 of equivalent makes in Philips/Wipro as approved by AGE(I). |
| 26 | Supply & fix in repairs PRIDE PLUS INVERTER BATTEN LED tube light fitting 20 watt, 6500 K, Inverter LED batten with square profile and polycarbonate channel. Lithium Ion battery with charging time 8-10 hours and battery back up time upto 10 hours and three step dimming energy efficient complete all as specified and directed Make. HAVELLS Cat Part No LHEXACP7FN1W020 of equivalent makes in Philips/Orient/Jaquar as approved by AGE(I). |
| 27 | Supply & fix in repairs E-Lite LED Pride Plus LED tube light fitting 9 watt, 6000 K, Decorative ultra slim round profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient complete all as specified and directed Make. HAVELLS Cat Part No LHEXBLP7IN1W009 of equivalent makes in Philips/Orient/Jaquar as approved by AGE(I). |
| 28 | Supply & fix, in repairs, Ellips Neo Hexa Bulkhead designed for modern homes available in non PIR as well as PIR sensor with premium quality LEDs 10 watt 6000K and including providing and connecting with twin core copper conductor twisted cable and testing on completion all as specified and directed. As per Cat No-LHEXCGP7IN5W006 of make Havells or equivalent make approved by GE from the make specified in Appx 'C'. |
| 29 | Supply & fix 10W LED bulb cool day light BEE 5 Star rating complete all as specified and directed. |
| 30 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of Single poles and current carrying capacity of 6-32 Amps in the MCB DB complete with connection testing and commissioning all as specified and directed by Engr in charge.. |
| 31 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN and current carrying capacity of 32 Amps in the MCB DB complete with connection testing and commissioning all as specified and directed by Engr in charge. |
| 32 | Supply and fixing amp rating 440V, 10KA 'C' curve miniature circuit breaker (MCB) of TPN and current carrying capacity of 32 Amps in the MCB DB complete with connection testing and commissioning all as specified and directed by Engr in charge.. |
| 33 | Supply and fixing amp rating 440V, 10KA 'C' curve miniature circuit breaker (MCB) of TPN and current carrying capacity of 63 Amps in the MCB DB complete with connection testing and commissioning all as specified and directed by Engr in charge.. |
| 34 | Supply & fix double door metallic sheet metal enclosure for DB double door(IP-42/43) When MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete all as specified and directed. |
| 35 | Supply & fix double door metallic sheet metal enclosure for DB double door(IP-42/43) When MCBs to be used SPN 6 ways, 240 V with 200Amps rated bus bar complete all as specified and directed. |
| 36 | Supply & fix double door metallic sheet metal enclosure for DB double door(IP-42/43) When MCBs to be used SPN 4 ways, 240 V with 200Amps rated bus bar complete all as specified and directed. |
| 37 | Supply & fix double door metallic sheet metal enclosure for TPN DB double door 04 way with bur bar, neutral link, blanking plates suitable for 440 volt complete all as specified and directed by Engr in charge. |
| 38 | Supply & fix in repair/replacement of MCCB TPN 63/100 Amps fixed thermal and magnetic releaese, 16 KA 415 Volt suitable for load line VTPB load line complete all as specified and directed. |
| 39 | Supplying ,Laying, jointing and testing PVC insulated, heavy duty, aluminum conductor cable of size 10 sq mm,2 core, 1100 volts grade ,Stranded conductor,laid in trenches/ducts, floors, fixed to pole/ walls etc. complete all as specified and directed by the Engineer-in-charge. |
| 40 | Supply & fix single phase temper proof, digital electric meter with LCD display, AC 230 V, rating 10-60 Amps & with 1 push button. (Measures & displays kWh, kVAh, V,I,PF, frequency, kW, kVA, six months history of Energy & MD in kW & kVA) with Transparent Hinge type Box including making incoming and outgoing connections etc complete. Make : HPL cat No - SPPB1520110002OC00 or equivalent as approved by GE. Note: Old meters shall be deposited in MES store Yard. |
| 41 | Material & labour, in repairs, earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth wire of 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I all as specified and testing on completion including provision of earth lead protected by 15 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note : Rate quoted by tenderers shall be deemed to include for following provisions;-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 M.[ii]. PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs, charcoal & salt as reqd.[v]. GI protection pipe of size 15 mm bore light grade 7.5m. |
| 42 | Supply & fix AC Plug 20A 2P with Earth, 230 Volt, AC complete all as specified and directed by Engineer-in-Charge. |
| 43 | Supply & fix AC Socket 20A 2P with Earth, 230 Volt, AC complete all as specified and directed by Engineer-in-Charge. |
| 44 | Supply & fix DBOXX MCB Protected Socket AC Socket 20A MCB Combo with Sheet steel enclosure with Plug Top, 230 Volt, AC complete all as specified and directed by Engineer-in-Charge. |
| 45 | NOTE :- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs 23410.00/- ] Please Enable Macros to View BoQ information |