| 1 | Demolition and breaking up 150 mm internal dia drain pipes (Salt glazed stone ware, AC or Reinforced concrete) including PCC bedding & hauching set in cement mortar complete all as specified and directed. |
| 2 | Demolition and breaking up 200 mm internal dia drain pipes (Salt glazed stone ware, AC or Reinforced concrete) including PCC bedding & hauching set in cement mortar complete all as specified and directed. |
| 3 | Demolition and breaking up 300 mm internal dia drain pipes (Salt glazed stone ware, AC or Reinforced concrete) including PCC bedding & hauching set in cement morter of above dia pipe Complete all as specified and directed. |
| 4 | Supply, laying & jointing 150 mm nominal bore (Internal Diameter) DWC (HDPE Double Wall Corrugated) Pipe, socketed & sewage pipe having 6.00 metre length, conforming to IS : 16098 (Part-II) of SN-4 Stiffness with & including necessary jointing materials etc complete all as specified & directed. |
| 5 | Supply, laying & jointing 200 mm nominal bore (Internal Diameter) DWC (HDPE Double Wall Corrugated) Pipe, socketed & sewage pipe having 6.00 metre length, conforming to IS : 16098 (Part-II) of SN-4 Stiffness with & including necessary jointing materials etc complete all as specified & directed. |
| 6 | Supply, laying & jointing 300 mm nominal bore (Internal Diameter) DWC (HDPE Double Wall Corrugated) Pipe, socketed & sewage pipe having 6.00 metre length, conforming to IS : 16098 (Part-II) of SN-4 Stiffness with & including necessary jointing materials etc complete all as specified & directed. |
| 7 | M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150 mm internal dia of pipe complete all as specified and directed. |
| 8 | M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 200 mm internal dia of pipe complete all as specified and directed. |
| 9 | M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 300 mm internal dia of pipe complete all as specified and directed. |
| 10 | M&L for Cement Concrete bed Type C-2, 1:3:6 (using 40 mm graded stone aggregate) to 150 mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified & directed. |
| 11 | M&L for Cement Concrete bed Type C-2, 1:3:6 (using 40 mm graded stone aggregate) to 200 mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified & directed. |
| 12 | M&L for Cement Concrete bed Type C-2, 1:3:6 (using 40 mm graded stone aggregate) to 300 mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified & directed. |
| 13 | M&L for Salt glazed stone ware gully traps size 150 x 150 mm, square or round mouthed, type ‘P’ including setting and jointing to drains with cement mortar 1:1 including demolition of existing traps complete all as specified and directed. |
| 14 | Excavating in trenches in soft/loose soil, not exceeding 1.5 metre wide & not exceeding 1.5 metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan & getting out complete all as specified & directed. |
| 15 | Excavating in trenches in soft/loose soil, not exceeding 1.5 metre wide & exceeding 1.5 metre & not exceeding 3.0 metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan & getting out complete all as specified & directed. |
| 16 | M&L for Returning, filling in soft/loose soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified & directed. |
| 17 | M&L for Removing surplus excavated material (soil) to a distance exceeding 250 metre but not exceeding 500 metre & depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified & directed. |
| 18 | Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework & precast concrete articles complete all as specified and directed. |
| 19 | M&L for Brickwork with old size flyash bricks, straight or curved on plan exceeding 6m mean radius, built in 1:4 cement mortar complete all as specified & directed. |
| 20 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 21 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces of wall in CM 1:4 and to be finished even and smooth (without using extra cement) complete all as specified and directed. |
| 22 | M&L for preparation of newly plastered or unplastered brick work or concrete surfaces & applying two coat of cement based paint over & including one coat of alkali resistant priming paint on prepared brick work or concrete surfaces complete all as specified and directed. |
| 23 | Demolition of cement concrete (un reinforced) in ground floor and pavings n.exc 15cm thickness (below or above GL) complete all as specified and directed. |
| 24 | M&L for PCC 1:4:8 type D2, 75mm thick using 40mm graded aggregate as in sub base complete all as specified and directed. |
| 25 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 26 | M&L factory made 60 mm thick rubber moulded glossy finish machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of M-35 grade complete all as specified and directed. |
| 27 | S&F factory made rubber moulded glossy finished Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 28 | Material and labour for cement concrete type B1, 1:2:4 (20mm graded stone aggregate) as in coping and the like including weathering, slightly rounded or chamfered angles and throating as directed complete all as specified. |
| 29 | Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided for complete all specified and directed. |
| 30 | M&L for providing Cement Concrete Type B-1, 1:2:4 (using 20 mm graded stone aggregate) as in lintels upto 1.5 m clear span, cills, steps; seismic & other similar bands, plinth courses, string courses, lacing courses, parapets & railings upto 60 cm in height, copings, benching, kneelers, apex stones, bed plates, kerbs, water troughs & the like including weathering, slightly rounded or chamfered angles and throating including necessary form work. Complete all as specified and directed. |
| 31 | M&L for Cement Concrete Type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 32 | M&L for kerb stone of PCC 1:2:4 type B-1( using 20mm graded stone aggregate) of and setting in CM 1:6 complete all as specified and directed. |
| 33 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified & directed. |
| 34 | S&F of Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 35 | Demolition of Cement Concrete (reinforced) of any description & in any position not otherwise specifically provided for complete all specified and directed. |
| 36 | M&L for Providing Precast Cement Concrete Type B-1, 1:2:4 using 20mm graded stone aggregate in landings, cover slabs (for manholes etc.), chullah hoods, chajjas, water troughs, mangers, shelves & similar articles with plain faces including necessary chamfers, weatherings, throating etc. & setting in 1:6 cement mortar including necessary formwork if required complete all as specified & as directed. |
| 37 | S&F of Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with & including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 38 | M&L for Providing precast concrete louvers and jallies type B0, 1:2:4 (12.5mm graded aggregate), 35mm thick (measured solid) set in cement mortar 1:4 including all moulding but excluding frame complete all as specified and directed. Please Enable Macros to View BoQ information |
| 39 | M&L for Providing precast concrete louvers and jallies type B0, 1:2:4 (12.5mm graded aggregate), 35mm thick (measured solid) set in cement mortar 1:4 including all moulding but excluding frame complete all as specified and directed. Please Enable Macros to View BoQ information |