| 1 | M&L for Submain wiring with two core 1100 volts 1.5 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 1.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly - including taking down of old unserviceable sub main wiring from ceiling / walls, complete all as specified and directed by Engr-in-Charge |
| 2 | M&L for Submain wiring with two core 1100 volts 1.5 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including in existing stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 1.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and ,connecting to earth point and connecting to earth dolly including taking down of old unserviceable sub main wiring from ceiling / walls, complete all as specified and directed by Engr-in-Charge |
| 3 | M&L for Submain wiring with two core 1100 volts 2.5 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 2.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and ,connecting to earth dolly including taking down of old unserviceable sub main wiring from ceiling / walls complete all as specified and directed by Engr-in-Charge |
| 4 | M&L for Submain wiring with two core 1100 volts 2.5 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including in existing stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 2.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and, connecting to earth dolly including taking down of old unserviceable sub main wiring from ceiling / walls complete all as specified and directed by Engr-in-Charge |
| 5 | M&L for Submain wiring with two core 1100 volts 4 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 4sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and , connecting to earth dolly - including taking down of old unserviceable sub main wiring from ceiling / walls complete all as specified and directed by Engr-in-Charge |
| 6 | M&L for Submain wiring with two core 1100 volts 4 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including in existing stove steel enameled conduit with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 4 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and, connecting to earth dolly including taking down of old unserviceable sub main wiring from ceiling / walls complete all as specified and directed by Engr-in-Charge |
| 7 | M&L for Submain wiring with two core 1100 volts 6 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 6 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and ,connecting to earth dolly including taking down of old unserviceable sub main wiring from ceiling / walls complete all as specified and directed by Engr-in-Charge |
| 8 | M&L for Submain wiring with two core 1100 volts 6 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through existing stove steel enameled conduit with accessories like flame proof bend, flame proof juntion box etc. complete all as specified in and including 6 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and, connecting to earth dolly including taking down of old unserviceable sub main wiring from ceiling / walls complete all as specified and directed by Engr-in-Charge |
| 9 | M&L for Submain wiring with two core 1100 volts 10 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including stove steel enameled conduit 20/25 mm dia with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 6 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly including taking down of old unserviceable sub main wiring from ceiling / walls complete all as specified and directed by Engr-in-Charge |
| 10 | M&L for Submain wiring with Two core 1100 volts 10 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through existing stove steel enameled conduit with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 6 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly including taking down of old unserviceable sub main wiring from ceiling / wallscomplete all as specified and directed by Engr-in-Charge |
| 11 | M&L for Submain wiring with four core 1100 volts 10 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including stove steel enameled conduit 25/40 mm dia with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including Two core 6 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly including taking down of old unserviceable sub main wiring from ceiling / walls complete all as specified and directed by Engr-in-Charge |
| 12 | M&L for Submain wiring with four core 1100 volts 10 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through existing stove steel enameled conduit with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including Two core 6 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and, connecting to earth dolly including taking down of old unserviceable sub main wiring from ceiling / walls complete all as specified and directed by Engr-in-Charge |
| 13 | Supply and Fixing in repair / replacement of Flameproof cum Waterproof LED light fitting of 60W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish including suitable hanging arrangements complete with all accessories pre wired and including connecting up with three core flame proof flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-Charge Note: The rates shall be deemed to be include the cost of taking down of old light fitting by providing suitable necessary ladders /equipments from any height. |
| 14 | All as per above item No. 13 but for Flameproof cum Waterproof LED light fitting of 100W, complete all as specified and directed by Engr-in-Charge |
| 15 | Supply and fix in repair / replacement HIGH BAY LED lights hanging/ceiling mounting type 100w fitting with PC diffuser with surge protection on existing light point with suitable hanging arrangements complete all as specified and directed by Engr-in-Charge. Note: The rates shall be deemed to be include the cost of taking down of old light fitting by providing suitable necessary ladders /equipments from any height. |
| 16 | Supply and fix repair / replacement Supply and fixing LED luminaire 600 mm x 600 mm,36/40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by engr-in-charge. |
| 17 | Supply and fix in repair / replacement Low BAY LED lights hanging/ceiling mounting type 40/45W fitting with PC diffuser with surge protection on existing light point with suitable hanging arrangements complete all as specified and directed by Engr-in-Charge. Note:- The rates shall be deemed to be include the cost of taking down of old light fitting by providing suitable necessary ladders /equipments from any height. |
| 18 | S & F in repair/ replacement flame proof plugin switch socket 16A , 3pin (2P+E) , 220V, 50 Hz ,AC and fixing arrangement including taking down of old existing flame proof swtich socket complete all as specified and directed by Engr-in-Charge. |
| 19 | S & F in repair/replacement flame proof plugin switch socket 25A , 3pin (2P+E) , 220V, 50 Hz ,AC and fixing arrangement including taking down of old existing flame proof swtich socket complete all as specified and directed by Engr-in-Charge. |
| 20 | S & F in repair/replacement flame proof plugin switch socket 32A , 5pin (4P+E) , 50 Hz ,AC and fixing arrangement including taking down of existing flame proof swtich socket complete all as specified and directed by Engr-in-Charge. |
| 21 | S & F in repair / replacement flame proof LED light fitting 1x16/20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size, including taking down of old existing light fitting complete all as specified and directed by Engr-in-Charge. |
| 22 | All as per above item No. 21 but for LED light fitting of 2x16/20W, complete all as specified and directed by Engr-in-Charge |
| 23 | S & F in repai r/ replacement flame proof MCB TPN DB 4 way,220V , 50 Hz ,AC and fixing arrangement incomer MCB 4P 63amp/100 Amp and outgoing MCB sp 12 NOs bus bar 100 Amp including taking down of DB & making good disturbed surfaces of wall complete all as specified and directed by Engr-in-Charge. |
| 24 | S & F in repair / replacement flame proof MCB SPN DB 12 way,220V , 50 Hz ,AC and fixing arrangement incomer MCB 2P and outgoing MCB SP 10 NOs bus bar 100 Amp including taking down of DB & making good disturbed surfaces of wall complete all as specified and directed by Engr-in-Charge. |
| 25 | S & F in repair/replacement MCCB/MCB 4 pole, thermal magnetic release range 100 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed by Engr-in-Charge |
| 26 | S & F in repair/replacement MCCB/MCB 4 pole, thermal magnetic release range 125 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed by Engr-in-Charge |
| 27 | S & F in repair/replacement MCCB/MCB 4 pole, thermal magnetic release range 63 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed by Engr-in-Charge |
| 28 | S & F in repair/replacement MCCB/MCB 4 pole, thermal magnetic release range 40 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed by Engr-in-Charge |
| 29 | S&F 6 to 32 AMP MCB single pole 240 V 10 KA (C-Series) complete including taking down of old existing MCB, complete all as specified and directed by Engr-in-Charge |
| 30 | S&F 32 Amps MCB SPN 240 V 10 KA (C-Series) complete including taking down of old existing MCB, complete all as specified and directed by Engr-in-Charge Please Enable Macros to View BoQ information |
| 31 | S&F 32 Amps MCB SPN 240 V 10 KA (C-Series) complete including taking down of old existing MCB, complete all as specified and directed by Engr-in-Charge Please Enable Macros to View BoQ information |