| 1 | Carriage of Following line materials from ESC, Muzaffarnagar to work sites including safe loading and unloading at both ends as per site condition :- |
| 2 | LT XLPE cable Al. 1x120 sqmm |
| 3 | LT XLPE cable Al. 1x240 sqmm |
| 4 | LT XLPE cable Al. 1x630 sqmm |
| 5 | CT 33 KV Ratio 400/200/1 Amp. |
| 6 | CT 33 KV Ratio 200/100/1 Amp. |
| 7 | 33 KV Lightening Arrestor |
| 8 | 33 KV line isolator |
| 9 | 11 KV VCB |
| 10 | 33 KV VCB |
| 11 | 33 KV Control Pannel |
| 12 | 33 KV TPMO |
| 13 | 33 KV 3x300 XLPE Cable |
| 14 | 11 KV 3x185 xlpe cable |
| 15 | 11 KV 3x120 xlpe cable |
| 16 | 33 KV 3x300 H/S XLPE Cable J/kit |
| 17 | 33 KV 3X300 H/S XLPE CABLE J/KIT OD |
| 18 | 11 KV 3x185 xlpe cable j/kit |
| 19 | 11 KV 3x120 xlpe cable j/kit |
| 20 | 11 KV 3x70 xlpe cable j/kit |
| 21 | 11 KV 3x70 sqmm xple cable |
| 22 | ACSR Dog conductor |
| 23 | 11 KV insulated dog conductor |
| 24 | ST Pole 13 mtr. long |
| 25 | PCC pole 11 mtr. long |
| 26 | PCC pole 8.5 mtr. long |
| 27 | 11 KV Polymeric pin insulator |
| 28 | 33 KV Polymeric pin insulator |
| 29 | 33 KV post Insolator |
| 30 | G.I. wire 4/6/8 SWG |
| 31 | Earthing complete |
| 32 | 11 KV Disc insulator with fitting |
| 33 | 33 KV Disc insulator with fitting |
| 34 | LT ABC 3x95 Sqmm. |
| 35 | 33 KV Fuse set |
| 36 | Stay set complete |
| 37 | 11 KV V-type X-arm |
| 38 | 33 KV V-type X-arm |
| 39 | Errection of ST Pole 13 Mtr. long as per norms and fixing all accessoriess (Nuts, Bolts, Washer and Clamps will be provided by contractor) |
| 40 | Errection of PCC Pole 11 Mtr. long as per norms and fixing all accessoriess (Nuts, Bolts, Washer, Stone Pad and Clamps will be provided by contractor) |
| 41 | Errection of PCC Pole 8.5 Mtr. long as per norms and fixing all accessoriess (Nuts, Bolts, Washer, Stone Pad and Clamps will be provided by contractor) |
| 42 | Errection of Four Pole Structur 11 Mtr. long as per norms and fixing all accessoriess (Nuts, Bolts, Washer and Clamps will be provided by contractor) |
| 43 | Concreting of PCC pole including all work of excavation, cement concreet in size .60x.60x.30mm in ration 1:4:8 (Cement, sand, 40mm brick ballast) as per drg. Including. |
| 44 | Laying of 33 KV XLPE Cable 3x300 sqmm by using HDPE Pype by trench less methord (HDPE pipe PE-80, PN-6, DN-200mm will be provied by contractor). |
| 45 | Dismentling of ald 33 KV VCB from the Sub Station yard including opening of all connection and carriage of VCB from contol room to out side the Sub Station yard. |
| 46 | Dismentling of ald 11 KV VCB from the Sub Station yard including opening of all connection and carriage of VCB from contol room to out side the Sub Station yard. |
| 47 | Erection of 33 KV control pannel |
| 48 | Making Structure for 03 No.s 33 KV isolator and 02 Nos. Control Pannel as per norms and proper installation of 03 No.s 33 KV isolator and 02 Nos. Control Pannel (all material will be provided by contractor). |
| 49 | Shifting of New 33 KV VCB from out side the Sub Station yard to in side the Sub Station yard with the helf of heavy duty crene and its instalation with grouting and anchor bolts. |
| 50 | Shifting of New 11 KV VCB from out side the Sub Station yard to in side the Sub Station yard with the helf of heavy duty crene and its instalation with grouting and anchor bolts. |
| 51 | Providing and fixing of 33 KV copper control cable size 4x2.5 sqmm |
| 52 | Doing the Chemical earthing and jointing to structure with GI Strip as per norms. (All material provided by contractor) |
| 53 | Making trench, laying the 33 KV XLPE cable 3x300 sqmm and refilling the trench after covering the cable with bricks and sand as per norms. |
| 54 | Laying overhead XLPE Cable 3x300 sqmm |
| 55 | Construction of foundation of 01 no. 33 KV VCB and 03 nos. 33 KV isolator |
| 56 | Making trench, laying the 11 KV XLPE cable 3x185 and refilling the trench after covering the cable with bricks and sand. |
| 57 | Making trench, laying the 11 KV XLPE cable 3x70 and refilling the trench after covering the cable with bricks and sand. |
| 58 | Laying overhead XLPE Cable 3x185 sqmm |
| 59 | Laying overhead XLPE Cable 3x120 sqmm |
| 60 | Laying overhead XLPE Cable 3x70 sqmm |
| 61 | Filling of 33 KV 3x300 H/S XLPE Cable J/kit |
| 62 | Filling of 3X300 H/S XLPE CABLE J/KIT OD |
| 63 | Filling of 3x185 XLPE Cable Jointing kit |
| 64 | Filling of 3x120 XLPE Cable Jointing kit |
| 65 | Filling of 3x70 XLPE Cable Jointing kit |
| 66 | Laying, lifting, sagging & binding of ACSR Dog conductor as per norms (Nut. bolts and AL. PG Clmaps will be provided be contactor) |
| 67 | Laying, lifting, sagging & binding of 33 KV Insulated Dog conductor as per norms (Nut. bolts and AL. PG Clmaps will be provided be contactor) |
| 68 | Providing and fixing of GI Pipe 150 mm dia |
| 69 | Laying, lifting, sagging & binding of LT XLPE cable Al. 1x120 sqmm |
| 70 | Laying, lifting, sagging & binding of LT XLPE cable Al. 1x240 sqmm |
| 71 | Laying, lifting, sagging & binding of LT XLPE cable Al. 1x630 sqmm |
| 72 | Shifting of New 33 KV CT from out side the Sub Station yard to in side the Sub Station yard with the helf of heavy duty crene and its instalation with grouting and anchor bolts. |
| 73 | Prpoer installation and commissioning of 33 KV TPMO |
| 74 | Prpoer installation and commissioning of 33 KV Fuse set |
| 75 | Prpoer installation and commissioning of 33 KV CT |
| 76 | fixing or mounted of lighteining Arrestor. |
| 77 | Errection of earth complete |
| 78 | Providing and fixing of Number Plate with clamp. |
| 79 | Providing and fixing of Danger Plate with clamp. |
| 80 | Providing and fixing of GI Barbed wire |
| 81 | Errection of stay complete and Grouting of stay rods including all work of excavation, cement concreet in size .60x.60x.30mm in ration 1:4:8 (Cement, sand, 40mm brick ballast) as per drg. including back filling & proper ramming etc. with fixing tightening & nuzzling of stay set with the pole |
| 82 | Providing and fixing of Bracing set 4.3x4.3 mtr angle iron 65x65x6 mm with clamp |
| 83 | Errection of earthing complete |
| 84 | Providing and Replacement of Damaged/Defective WTI by New WTI Suitable for Power Transformer Rating 5 MVA, 8 MVA & 10 MVA, Installed at various 33/11 kv Sub station under EUDD-Town Hall Muzaffarnagar. |
| 85 | Providing and Replacement of Damaged/Defective OTI by New OTI Suitable for Power Transformer Rating 5 MVA, 8 MVA & 10 MVA, Installed at various 33/11 kv Sub station under EUDD-Town Hall/Jansath/Civil Lines, Muzaffarnagar. |
| 86 | 11 KV Relay, Ashida numerical O/C & E/F Protection Relat ADR 241A (with housing) ashida make. |
| 87 | Providing and fixing of Crimping Lugs at 100 KVA Transformer with the help of hydrolic crimping tools. |
| 88 | Providing and fixing of Crimping Lugs at 250 KVA Transformer with the help of hydrolic crimping tools. |
| 89 | Providing and fixing of Crimping Lugs at 400 KVA Transformer with the help of hydrolic crimping tools. |
| 90 | Providing and fixing of Al. jointing sleeves |
| 91 | Providing and fixing of 11 KV E-Bracket |
| 92 | Providing and fixing of 33 KV E-Bracket |
| 93 | Guarding work of 33 KV Line |
| 94 | Guarding work of 11 KV Line |
| 95 | Rustede Cleaning and galvenised painting of isolator structure complete. |
| 96 | Rustede Cleaning and galvenised painting of Gantry structure complete. |
| 97 | Rustede Cleaning and galvenised painting of Power Transformer |
| 98 | Rustede Cleaning and galvenised painting of CT/PT and 33 KV VCB. |
| 99 | Havells led flood light 200 watt, cool yello |
| 100 | Installation of street light timer with box, nut, bolt and clamp. |
| 101 | Installation of street light at pole and making proper connection (copper Controll cable 2x2.5 mm 400 Mtr. and plastic pipe best quality 400 mtr. will be provided by contractor) |
| 102 | Providing and fabrication of top channel 100x50x6 mm, 240 mm Long. |
| 103 | Providing and fabrication of Dropper channel 100x50 mm, 3200 mm Long. |
| 104 | Providing and fabrication of MS angle 65x65x6 mm, 1.6 mtr. long |
| 105 | Providing of Channel 3.5 Mtr. ( size 125x65x6 mm) |
| 106 | Providing of angle 2.6 Mtr. ( size 75x75x6 mm) |
| 107 | Providing of angle 50x50x6 mm. |
| 108 | Making of 33 KV line isolator structure as per respo norms. |
| 109 | Installation and commissing of 33 KV Line isolator (Nut, bolts and clamps will be provided by contractor) |
| 110 | Providing and fabrication of T-Off Channel |
| 111 | Tree branching cutting compensation |
| 112 | Dismentling of following materials and carriage to JE Store |
| 113 | MS Iron Scrap |
| 114 | ST Pole Scrap |
| 115 | ACSR Conductor Scrap |
| 116 | LT ABC Scrap |
| 117 | Scrap LT XLPE Cable |
| 118 | Old/Damaged 33 KV VCB |
| 119 | Old/Damaged 11 KV VCB |
| 120 | Damaged Control Cable |
| 121 | Damaged Control Pannel Please Enable Macros to View BoQ information |