Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Item Wise BoQ BoQ_Ver3.0 Item Wise Normal INR Only INR Select, Excess (+), Less (-) Tender Inviting Authority: Superintending Engineer, Electricity Construction & Work Circle-I, P.V.V.N.L., Meerut Bought Out Name of Work: Construction of New 2×5 MVA 33/11 KV Sub-Station BHANDOORA, Muzaffarnagar alongwith constructions of Associated 33 KV Line and 11 KV Feeder Direct Tender Reference No : 20/ECWC-I/MRT/2026-27 Quote for Supply Portion only Bidder Name : Quote for Erection Portion only PRICE BID1. This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns after validating the sheet, else the bidder is liable to be rejected for this tender.2. Bidders are allowed to enter the Bidder Name and Unit Ex-Works Price and GST in %age only.3. All the material and erection practices shall be as per tender specification.5. Above Schedule Structure and quantities is provisional and may vary as per site requirement with due approval.6. Indicative scope of works and quantity of Items/Materials required for above work shall be as per the Price Bid. Any other material if required to complete the job and not mentioned above, shall have to be provided by the bidder without additional cost.7. Financial evaluation and selection of 'L1 Bidder' shall be done on the basis of total amount. The rates received in the tender will be final after the approval of the Competent Authority/Committee and the competent Authority/committee will have the right to negotiate in tender rate/amount.8. Tenderer must be fill-up the enclosed terms & conditions sheet and attached with 1st Part of Tender as well as scanned copy of same will be uploaded on NIC Website alongwith other documents.9. Bidders must be filled up the GST in %age, Otherwise it is assumed G.S.T. rates are included in the given ex-works price (Rs./Unit). NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Works Item Code Tender Qty. Unit Estimated Rate Bought-out/Direct Specify Bought-out/Direct Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Unit Ex-Works Price(Rs./unit) Excise Duty(Rs/Unit) CST/VAT(Rs/Unit) Other Taxes & Duties(Rs/Unit) Freight & Insurance Charges(in Rs./Unit) Unit FOR Dest. Supply Price incl. all Taxes and Duties(in Rs./Unit)(F+G+H+I+J) Total Value for Supply or Erection (In Rs.)(C x F) GST (in Rs.) in %age Total Value for GST (in Rs.) (F*M/100) Total Unit Price incl. GST (in Rs.) Total Amount excl. GST (in Rs.) (4×13) Total Amount incl. GST (in Rs.) (4×26) TOTAL AMOUNT In Words |
| 2 | Supply of following material90 Lbs. Rail pieces for T/F & bus -bar gantry Wt. 44.6 Kg/Mtr. |
| 3 | M.S Angle (50×50×6) mm |
| 4 | M.S. Channel (100×50x6)mm |
| 5 | M.S. Angle (65×65x6)mm |
| 6 | MS strip size 50×6 mm |
| 7 | M.S. Round 32mm (for earth mat & delta earthing etc.) |
| 8 | Outdoor switchyard light pole (as per specification) |
| 9 | Outdoor switchyard light LED 40 watt (as per specification) |
| 10 | PVC control cable 2x2.5 sq mm |
| 11 | PVC control cable 4x2.5 sq mm |
| 12 | Copper Bus Bar size 50×6 mm–2.4 Mtr. long |
| 13 | Fire Fighting equipments including 02 Nos. 4.5 Kg. Co2 Fire Extinguisher potable type and 02 Nos. Foam type Fire Extinguisher potable type |
| 14 | Substation Furniture (4–Chairs, 1–Table, 1–Bench, 1–Rack, 1–Stool) |
| 15 | Misc. Items. l.e. Rubber Matting Single Line Diagram Board, Tripping chart Board, Sub-Station Board |
| 16 | M.S.Angle Iron 65x65x6mm. 4300mm long Bracing |
| 17 | M.S Channel 125x65x3200 mm. (Top Channel) |
| 18 | Dropper channel 100×50mm 2028 mm. Long |
| 19 | M.S.Angle Iron 65x65x6mm. 2700 mm long (for O/H cable and line) |
| 20 | M S Channel 100x50 mm 2240 mm long (for O/H cable and line) |
| 21 | G.I Wire No. 6 SWG |
| 22 | G.I Wire No. 8 SWG |
| 23 | GI wire 16SWG for binding |
| 24 | Guarding Angle 75×75×6 mm , 3010 mm long |
| 25 | Cross Arm Holding clamp for 11M PCC & S.T. Pole 13 M long, 8.5 Mtr long PCC pole |
| 26 | Top Channel Holding Clamp for 11M PCC & S.T. Pole 13 M long, 8.5 Mtr long PCC pole |
| 27 | Stay Clamp for 11M PCC & S.T. Pole 13 M long, 8.5 Mtr long PCC pole |
| 28 | Guarding Clamp for S.T. Pole 11 M & 13M long, 8.5 Mtr long PCC pole |
| 29 | F Bracket for 33 KV |
| 30 | E Bracket for 33 KV |
| 31 | E Bracket for 11 KV |
| 32 | Danger Board with clamp for 11M PCC & S.T. Pole 13 M long, ,8.5 Mtr PCC pole |
| 33 | Number Plate with clamp for 11M PCC & S.T. Pole 13 M long, ,8.5 Mtr PCC pole |
| 34 | Braccing clamps clamp for 11M PCC & S.T. Pole 13 M long, ,8.5 Mtr PCC pole |
| 35 | Aluminum Binding wire 6 SWG |
| 36 | G.I.Barbed Wire |
| 37 | Red Oxide Paint |
| 38 | Aluminium paint |
| 39 | M.S. Bolts Nuts & Washers |
| 40 | Earth wire clamp with Nut & Bolts |
| 41 | D-Shackle Insulator |
| 42 | Stone pad (300×300×75)mm |
| 43 | P.G. clamp for Dog to Dog conductor |
| 44 | G.I. Pipe 160mm dia 3.00 Mtr. long |
| 45 | Supply of HDPE Pipe PE-80, PN-6, DN-160mm dia Pipe |
| 46 | Cable route marker |
| 47 | Sundries Item |
| 48 | Eye bolt |
| 49 | Holding Clamp for GI Pipe |
| 50 | Holding Clamp for Pole |
| 51 | Lug for ACSR Dog Conductor |
| 52 | Turn Buckle |
| 53 | clamp for overhead cable laying |
| 54 | T&P of sub-station switchgear |
| 55 | 10 inch exchaust fan complete in all respect |
| 56 | 11 KV fuse set ,complete |
| 57 | 11 KV TPMO ,complete |
| 58 | Safe carriage of following items from any store within PVVNL to site store (provide by working firm ) with loading & unloading at both ends respectively. (under jurisdiction of PVVNL) 1. 33KV VCB 1250A |
| 59 | 33 KV VCB 800A, 750 MVA |
| 60 | 33 KV Control Panel with Double Transformer Control |
| 61 | 33 KV C.T. 200/100/1-A |
| 62 | 33 KV C.T. 400/200/1-A |
| 63 | 33KV control relay panel for 33 KV line |
| 64 | 33 KV Line Isolator |
| 65 | 33 KV Bus Isolator |
| 66 | 33 KV Lightning Arrestors |
| 67 | 33 KV Fuse Set |
| 68 | 33 KV Pin Insulators polymeric |
| 69 | ACSR DOG Conductor |
| 70 | 33 KV PT, 33 KV/110V-1 Phase |
| 71 | 33 KV Post Insulators |
| 72 | 11 KV Pin Insulator polymeric |
| 73 | 33 KV Electronic TVM Meter |
| 74 | Meter Box for TVM Meter |
| 75 | 11 KV VCB (Incoming) 600/300/5A 350 MVA |
| 76 | 11 KV VCB (Out going) 200/100/5A 350 MVA |
| 77 | 11 KV Bus Coupler, 1250 MVA |
| 78 | 11 KV 3X300 sq mm XLPE cable |
| 79 | 11 KV 3X185 sq mm XLPE cable |
| 80 | 11 KV Cable Jointing Kit 3×300 mm² Indoor Type |
| 81 | 11 KV Cable Jointing Kit 3×300 mm² Outdoor Type |
| 82 | 11 KV Cable Jointing Kit 3×185 mm² Indoor Type |
| 83 | 11 KV Cable Jointing Kit 3×185 mm² Outdoor Type |
| 84 | 33 KV, 3×300mm² XLPE Cable |
| 85 | Outdoor Type cable Jointing kit for 33 KV XLPE cable 3×300 mm² |
| 86 | V Type Cross Arm 33 KV |
| 87 | 11 KV 'V' Type Cross Arm |
| 88 | L.T.P.V.C. Cable 3½×70 mm2 |
| 89 | 24 Volt Battery & Battery Charger with cabinet |
| 90 | 63 KVA 11/0.4 KV Transformer |
| 91 | PCC Pole 11M long |
| 92 | Steel Tublar Pole SP-72 13M (Bottom Portion Galvanized) |
| 93 | PCC Pole 8.5 Mtr. Long |
| 94 | MS Earthing Rod of 20x2540mm |
| 95 | Stay Sets (20×1800)mm |
| 96 | Stay Sets (16×1800)mm |
| 97 | Stay wire G.I 7/10SWG |
| 98 | Stay wire G.I 7/8SWG |
| 99 | 11 KV Disc Fitting T&CType 45 KN. (Polymerie) |
| 100 | 11 KV Disc Insulator T&C Type 45 KN (Polymerie) |
| 101 | Disc Fittings B&S for Dog 70 KN |
| 102 | Disc Insulators B&S 7000 Kg. |
| 103 | A- Miscellaneous Civil works at proposedTerminal Gantry :providing ,Fabrication & erection of terminal gantry as per details:–a) Excavation of earth for making 2 Nos. pits of size (1.4×0.75×2.2)M |
| 104 | b) Fabrication and erection of Terminal Gantry by using 4 Nos. of 8.2 M long (175×85)mm, 19.5 Kg/meter or (100×116)mm, 23.1 Kg/meter R.S. Joist with bracing of the same by M.S. Angle Iron of size (50×50×6)mm & Providing 2 Nos. of 3.2m long pieces of M.S. Channel of size (125×65×6)mm for Top as well as Dropper channel. The work also includes cutting, drilling and welding with alignment etc for proper completion of work. |
| 105 | c) C.C. work in ratio of 1:4:8 (cement, fine sand and brick ballast) of size (1.40×0.75×0.15)m for 2 Nos. pits for making bed after proper ramming etc. |
| 106 | d) C.C. work of ratio 1:3:6 (cement, coarse sand and 20 mm stone grit) for the structure of 02 Nos of pre- fabricaled legs of Terminal gantry (8.2m long) as per drawing No. RES-38 size of plinth (1.4×0.75×2.95)m. |
| 107 | e) 12 mm thick plaster with cement mortar ratio 1:4 (cement & fine sand) of plinth of 0.15 m above ground level. |
| 108 | Bus–Bar GantryProviding ,Fabrication & erection of Bus Bar Gantry as per detail:–a) Excavation of earth for making 4 Nos. pits of size (0.75×0.75×1.2)m |
| 109 | b) Fabrication and erection of Bus Bar Gantry by using 04 Nos. 6.4 m long 90 lb/105 lb Rail and M.S. Angle (50×50×6)mm for cross bracing of Bus-Bar and providing top channel of size (125×65×6)mm as per drawing RES-38. The work includes cutting, drilling, bolting and alignment of the same for proper completion of work. |
| 110 | c) C.C. work in ratio of 1:4:8 (cement, fine sand and brick ballast) of size (0.75×0.75×0.15)m for 4 Nos. pits for making bed after proper ramming etc. |
| 111 | d) C.C. work of ratio 1:3:6 (cement, coarse sand and 20mm size stone grit) for the plinth of 02 Nos. structure. pre-fabricated Bus-Bar Gantry size of Plinth (0.75×0.75×1.2)m, 4 Nos. after proper ramming over stone pad/bed |
| 112 | e) 12 mm thick plaster with cement mortar ratio 1:4 (cement & fine sand) of plinth of 0.15 m above ground level. |
| 113 | Isolator StructureProviding, Fabrication & erection of Isolator structure (Line & Bus)–3 Nos. size of plinth (0.9×0.30×1.0)m as per drawing no. RES-39 a) Excavation of earth for making 04 Nos. pits of size (0.9×0.30×1.0)m |
| 114 | b) Fabrication and erection of Isolator structure (Bus & Line) each by using 3.5 m long 04 Nos. of M.S. channel of size (125×65×6)mm with bracing by M.S. Angle (50×50×6)mm size and providing 02 Nos. M.S. Angle (75×75×6)mm and 2.6m long on the top of Channel at both side of Isolator. The work also includes cutting, drilling, welding and proper alignment of the same for completion of work. |
| 115 | c) C.C. work in ratio of 1:4:8 (cement, fine sand and brick ballast) of size (0.9×0.3×0.15)m for 04 Nos. pits for making bed after proper ramming etc. |
| 116 | d) C.C. work of ratio 1:3:6 (cement, coarse sand and 25 mm stone grit) for pre-fabricated structure of Line and Bus isolator size of plinth (0.9×0.3×1.00)m for 04 Nos. |
| 117 | e) 12 mm thick plaster with cement mortar ratio 1:4 (cement & fine sand) of plinth of 0.15 m above ground level. |
| 118 | Providing, Fabrication & erection of L.A.s-3 nos /P.I.s- 2 nos ,/C.T.s-3 nos /P.T.s-1 nos/Fuse Set-2 nos structure:– (11 nos)details (Quantity for 11 nos structures):–a) Excavation of earth (0.30×0.30×1.0)m for 02 Nos. Pits of above each structures. |
| 119 | b) Fabrication and erection of L.A.'s/P.I.'s/C.T.'s/PT / Fuse Sets structure by using M.S. Channel (125×65) mm size and 3.5 m minimum height with 2 Nos. M.S. Angle (75×75×6/65×65×6)mm size on top of structure for installation L.A.'s/P.I.'s/C.T.'s/PT / Fuse Sets (18 nos ) |
| 120 | c) C.C. work in ratio of 1:4:8 (cement, fine sand and brick ballast) of size (0.30×0.30×0.15)m for 02 Nos. pits for making bed for each structure. Work includes proper ramming etc. |
| 121 | d) C.C. Work of ratio 1:3:6 (cement, coarse sand and 25 mm size stone grit) for the above plinths for structure of L.A.'s/P.I.'s/C.T.'s/PT / Fuse Set after ramming of earth of size (0.3×0.3×1.00)m. for each pit and 02 Nos. Pits in a structure Over stone pad/bed |
| 122 | e) 12 mm thick plaster with cement mortar ratio 1:4 (cement & fine sand) of plinth of 0.15 m above ground level. |
| 123 | Plinth for 5 MVA Transformer (02 Nos.)Construction of plinth for 5 MVA, 33/11 KV Transformer of size (4.46×3.46×1.0)m (0.50m below ground level and 0.5 m above ground level) as per details & drawing attached:–a) Excavation of earth (4.50×3.50×0.5)m |
| 124 | b) Flooring of plinth in C.C. 1:4:8 (cement, sand & brick ballast) for making foundation bed. Size (4.50×3.50×0.15)m |
| 125 | c) Ist Class brick work for side walls size 0.345 m wide upto 0.3 M height and 0.23 m wide upto 0.35 m height C.C. ratio of 1:4 (cement & find sand) |
| 126 | d) Filling of brick ballast in plinth in ratio 1:4:8 (cement, coarse sand & brick ballast) with proper ramming. Size (4.0×3.0×0.65)m |
| 127 | e) R.C.C. work in the top layer of plinth in ratio 1:2:4 in size (4.46×3.46)m and 0.20 m thickness by using MS bar of 12mm dia both ways. The work also includes binding of steel reinforcement. |
| 128 | f) Quantity of M.S. bar of size 12 mm dia required for reinforcement of plinth in R.C.C. work should be 18 nos. bars of 3.4 mtr length and 12 nos. bars of 4.40 mtr. length. Work also includes cutting, bending and laying etc. in the T/F plinth. |
| 129 | g) Grouting of 02 Nos. 90/105 lb. Rail pieces of 3.46 M long and (50×50×6)mm M.S. Angle in R.C.C. work at the top of plinth work also includes cutting of rail and angle pieces etc. |
| 130 | h) 12 mm thick plaster with cement mortar ratio 1:4 (cement & fine sand) of plinth of 0.5 M above ground level. |
| 131 | Plinth for 33 KV V.C.B. ( 3 Nos)Construction of plinth for the structure of 33 KV VCB as per details a) Excavation of earth of size (2.4×1.5×1.0) m pits for construction of plinth. |
| 132 | b) Brick Ballast ratio (1:4:8) (cement, sand & brick ballast ) for foundation work (2.4×1.5×0.15)m plinth. |
| 133 | c) C.C. work in ratio 1:2:4 (cement, coarse sand &stone grit) of 20mm size for making plinth of size (2.4×1.5×1.00)m and grouting of foundation bolts 04 Nos. for 33 KV VCB. |
| 134 | d) 12 mm thick plaster with cement mortar in ratio 1:4 (cement & fine sand) of plinth of 0.15 m above ground level size (2.4×1.5)m. |
| 135 | Earth Mat Worka) Excavation of earth of size (0.5×0.75×369)m in switchyard area as per drawing for laying of 32 mm dia M.S. Round and 50×6mm size M.S. strip and refilling & ramming of the same earth into the trenches after completion of work |
| 136 | b) Laying of Earth Mati) Laying of 32 mm dia M.S. Round Bar in 0.75 m deep trenches as excavated in items. |
| 137 | ii) Welding with lap joint minimum length 150mm over lapping on both side of item (b)(i) shall be done so that all the edges may fill completely with high quality Arc welding. All joints shall be painted with black bituminous paint. |
| 138 | c) Jointing of 32 mm dia M.S. Round in earth mat at cross joint using high quality Arc welding. 75 mm piece of 32 mm Dia M.S. Round shall also be welded to make the joints strong for transfer the fault current. Work also included cutting welding and painting with black bituminions paint of joint etc. |
| 139 | d) Fabrication of 32 mm dia bar for 3.0 m long electrodes and digging them into ground so that the top of M.S. Round/Electrode remains at least 0.75m in air and jointing of earth electrode with the Earth Mat by using 75mm long piece of M.S. Round using high quality Arc welding and paints of joints with black bituminious paint. |
| 140 | e) Laying of M.S. Earth Strip :–i) Laying of M.S. Earth strip of size 50×6mm about 160 mtr. length for connecting the Earth Mat with steel structure. |
| 141 | ii) The work also includes cutting, bending, straightening, over-lapping and welding the Earth Strip with Earth Mat and various steel structures by using high quality Arc welding in already digged trenches. |
| 142 | iii) Painting of Earth Strip of size (50×6)mm with one coat of ready mixed primer with two coats of ISI mark synthetic channel green paint. |
| 143 | Construction of Control cable trench as per details a) Excavation of earth in size 0.650×0.40×100m. |
| 144 | b) C.C. work in foundation in ratio 1:4:8 (Cement, sand & Brick Ballast) with proper ramming in size 0.650×0.15 Mtr. |
| 145 | c) First Class Brick work in cement mortar in ratio 1:4 in size 0.23×0.32 Mtr. |
| 146 | d) 25 mm thick C.C. in floor of Cable Trench in ratio 1:2:4 (cement, coursend and Stone ballast) 20mm gauge in size 0.3 mtr. Width |
| 147 | e) Grouting of M.S. Angle of size 450×25×6mm in cable trench 100mm above floor level and at equal space distance 300mm |
| 148 | f) Plastering of Trench in Cement, Mortar in ration 1:4, 12mm thick in cable trench. |
| 149 | g) Fabrication and fixing cable trench cover of M.S. Angle Iron size 50×50×6mm of size 0.3m wide 0.5 to 1.0 mtr. length with proper welding of 8 mm size of bar 2 Nos. in length and 6 Nos. in width. i) 0.5 Mtr. long |
| 150 | ii) 1.00 Mtr. Long |
| 151 | Painting of StructuresPainting of the following structure with one coat of ready mixed primer and two coats of ISI Mark Aluminium paint after rubbing with sand paper to the surface of the structure including labour and T&P complete in all respect :–a) Terminal Gantry Structure |
| 152 | b) Bus Bar Gantry Structure |
| 153 | c) Line Isolator/Bus Isolator/Post Insulator/Fuse Set/C.T./P.T.s/L.A.s /cable suport/ T & L structures etc. |
| 154 | B- Miscellaneous Electrical works at Newly proposedInstallation of 33/11 KV, 5 MVA Transformer :Safe loading in private vechicle and safe carriage of 33/11 KV, 5 MVA Transfarmer (old & used) from sub-station where its available (within PVVNL ) to 33/11 KV sub-station BHANDOORA, Muzaffarnagar & safe unloading it. |
| 155 | Replacement of Top cover and all others old & damaged gasket. |
| 156 | Welding of body and radiators of 33/11 KV 5 MVA Transformer (old & used) if any leakage found. |
| 157 | Centrifuging of Transformer oil (old & used). |
| 158 | Painting of 33/11 KV 5 MVA T/F (Old & Used) |
| 159 | Shifting of available 5 MVA 33/11 KV, Transformer on plinth in Switch Yard. |
| 160 | Erection of shifted Transformer at plinth by fixing all accessories like radiators, conservator tank, filling the transformer oil to desired level and ensuring that there is no leakage, complete job in all respect. |
| 161 | Providing and Boring and lowering of G.I. Pipe size 32 mm dia… into the ground up to water level 20 Mtr., with the lower end of solid copper cone Approx 225mm long and 750 gm in weight shall be provided and screwed in pipe as well as bringing out a continuous copper wire 6 SWG from the cone up to the ground surface where it will be bolted to the M.S. earth Strip for Transformer neutral connection, the earth strip will be welded to the G.I. pipe and neutral earthing support. |
| 162 | Fabrication and erection of neutral earthing L Type support made of M.S. Channel size 100x50mm. Structure shall be 4 Mtr. Long with 1 Mtr. Arms. Structure shall be grouted in ratio 1:3:6 in block size 300x300x700mm and painted of welding joint with one coat of Ready Mixed primer and Two coat of enamel Aluminium paint work includes connecting neutral bushing rod of power Transformer and M.S. Earthing strip with the help of flexible copper bond, M.S. Bolt and washer. |
| 163 | Fabrication and erection of cable support made of two pieces of M.S. Angle (50×50×6)/65×65×6) mm, 2.75 meter long, joined to each other by means of 5 Nos. M.S. Flat (50×6)mm pieces of size 150 mm long each by welding at equal intervals and grouting in a block of size (300×300×700)mm in CC 1:3:6 complete with one coat of ready mixed primer and two coats of Al. paint. Work includes providing of three Nos. M.S. clamps made of (50×6)mm M.S. Flat for holding the cable including nuts and bolts. |
| 164 | Fabrication and grouting of M.S. frames 3.60 mt. long for support of copper Bus Bar. Bus Bar will be provided in L.V. Side of Power transformer. The M.S. frame shall be made of M.S. channel (100×50)mm in 'T' shape. Providing 2 Nos. support of M.S. Angle iron (50×50×6)mm, 0.60 mt. long below the top channel, drilling of 3 Nos. hole on the top channel for fixing of 11 KV pin insulator. The M.S. frame shall be painted with one coat of primer & two coat of aluminum paint and grouting the frame in C.C. ratio 1:3:6 in a block of size (300×300×700)mm. The work also includes the fixing of 3 Nos. 11 KV pin insulator with pin and binding the copper Bus Bar with the pin insulator by Aluminum binding wire in complete. |
| 165 | Fabrication of copper bus bar of size (50×6mm, 2400 mm long in L.V. side of 5 MVA 33/11 KV, power transformer. Work includes connection of this bus bar in L.V. side busing rod of Power Transformer and other side with outdoor 11 KV cable box as well as providing empire tape and H.T. tape etc. for proper insulation work. |
| 166 | Installation of 11 KV Switch Gears in Control Room :a) Carefully & safely shifting of 11 KV switch gears from outside to switch gear room grouting foundation of bolts in C.C. ratio of 1:2:4 (including cutting of RCC floor and finishing of RCC floor) as per requirement placing, aligning and fixing of 11 KV anchor GI bolts and nuts of proper size for completion of work. |
| 167 | b) Safely mounting of 11 KV PT on 11 KV Incoming switch gear filling of oil (if required) making all electrical connections and testing & commissioning of work. |
| 168 | c) Proper fixing and making bus bar connection in between two switch gears after proper cleaning. Work also include proper insulation, taping by empire, PVC and H.T. tape etc. |
| 169 | H.T. Power Cable Laying :a) Laying 11 KV, 3×300 mm2 XLPE, Power cable from outgoing switch gear to 11 KV double poles in the cable trench 0.45m wide, 0.90m depth. Providing sufficient sand cushion beneath and above the cable for cooling purpose . The cable shall be duly protected by brick. On both side of cable by laying bricks vertically and bricks would also be laid horizontally on top of vertically laid bricks along the cable. |
| 170 | b) Laying and dressing of 11 KV 3×300 mm² power cable in air/Trench. |
| 171 | c) Laying 11 KV, 3×185mm2 XLPE, Power cable from outgoing switch gear to 11 KV double poles in the cable trench 0.45m wide, 0.90m depth. Providing sufficient sand cushion beneath and above the cable for cooling purpose . The cable shall be duly protected by brick. On both side of cable by laying bricks vertically and bricks would also be laid horizontally on top of vertically laid bricks along the cable. |
| 172 | d) Laying and dressing of 11 KV 3×185 mm² power cable in air/Trench. |
| 173 | Preparation of 11 KV Power Cable ends :a) Making of 11 KV , 3x300 sqmm / 3x185 sqmm XLPE Heat shrinkable out door jointing kits after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs. |
| 174 | b) Making of 11 KV , 3x300 sqmm / 3x185 sqmm XLPE Heat shrinkable indoor jointing kits after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs. |
| 175 | c)Fixing/wearing of 160 mm dia 3 mtr. long G.I. pipe in the feeder cable of size of (3×185)mm2 XLPE power cable before making the outdoor cable boxes. The work includes the sealing of G.I. Pipe, top end and lower end of the pipe is to be buried in to the ground about ½ m and proper dressing of cable etc. The work includes lifting, mounting and clamping of 11 KV feeder cable boxes on the feeder with double pole structure and making connections including supply of cable mounting clampls etc. |
| 176 | Installation of 24 V Battery and Battery Charger :assembling and installation of the cabinet of 24 V battery and battery charger in switch gear control room including grouting of foundation bolts as per drawing of manufacture, including providing the foundation nuts and bolts of proper size. The electrical connection between battery and battery charge with flexible copper lead of size 7/20 SWG shall be done properly. The work includes installation, wiring upto control panel, testing and commissioning complete in all respect. |
| 177 | Control Cable Laying a) Laying of control cable (2×2.5)mm² i.e. from Buchholz relay to Marshalling box Marshalling box to switch gear room, 33 KV CT's 33 KV, V.C.B. Control Panel operating mechanism panel from T/F etc. in the cable trench including making proper connection at Buchholz Relay, Marshalling box as per required for installed equipment. |
| 178 | b) Laying of (4×2.5)mm2 control cablesi.e. from Buchholz relay to Marshalling box Marshalling box to switch gear room, 33 KV CT's 33 KV, V.C.B. Control Panel operating mechanism panel from T/F etc. in the cable trench including making proper connection at Buchholz Relay, Marshalling box as per required for installed equipment. |
| 179 | Earthing of 11 KV Switch Gears :a) Preparation of earth mat for earthing of all indoor equipments by means of M.S. earth strips (50×6) mm connecting to 4 Nos. earthing electrodes of 32 mm dia. (including fabrications of earthing electrodes) 3m long on either side (as per RESSPO drg. RES-40). This work includes driving of earthing electrodes, driving them into earth so that its top remains 500 mm below ground level, earth work, laying, bending, welding of M.S. earth strips (50×6)mm and also laying of the M.S. strip (50×6)mm in trench of control room and connecting to both sides squares including cost of earth strip (50×6)mm. |
| 180 | b) Earthing of all indoor equipments by laying and providing M.S. earth strip (50×6)mm including cutting, bending and welding etc. |
| 181 | Lighting Arrangement of 33/11 KV S/S outdoor switch yard and its area :a) installation and erection of 08 Nos. 6 Mtr. long street light supports with 2.4 Mtr. long street light brackets including fixing and supply of junctions box, street light support shall be made and fabricated from M.S. pipe of 3.0 Mtr. long 100mm dia. and 3.0 Mtr. long 75mm dia with 2.4 Mtr. long street light bracket in arc shape and made up of 40 mm dia M.S. pipe. This work includes, painting one coat with red oxide and 2 coats of ISI mark aluminium paint grouting of support in C.C. ratio 1:4:8 (cement, sand and brick ballast) in size (0.40×0.4×1.2)m. Lighting poles shall also be earthed by connecting to earth mat. |
| 182 | b) Fixing of 08 Nos LED Light 40 W and of standard quality ISI Mark with water tight elbow fitting etc. complete in all respect and suitable for above street light supports. |
| 183 | c) Laying of 3½×70 mm2 PVC LT cable from 11/0.4 KV, 63 KVA T/F to L.T. distribution board in switch gear room after digging trench for laying cable and refilling of trench including connections at both ends after providing and crimping of lugs of proper size for completion of work and laying brick over & both sides of L.T. cable after digging trench of 0.3 m wide & 0.5 m depth and providing and wearing 75mm dia G.I. Pipe of 2.5 M length over L.T. Cable complete in all respect. |
| 184 | d) Providing & Fabrication of L.T. distribution board of size (1×0.75×1.4) m by using M.S. Angle size (65×65×6)mm and grouting stand in switch gear room at proper place. 12 mm thick Indian wooden ply with sunmica top will be fixed on the ply frame and frame will be painted by one coat of primer red oxide and two coats of smoke grey paint. |
| 185 | e) Providing, fixing and wiring with 7/20 SWG PVC wire of following ICTP/ICDP switches of standard quality ISI mark on L.T. Distribution board complete work including cost of all materials:–i) ICTP switch three phase, 4 wire 100 Amps & 415 volts rewirable main switch. |
| 186 | ii) ICDP switch single phase, 2 wire 10 Amps & 230 volts switch. |
| 187 | f) Providing and laying (2×6)mm2 L.T. Aluminium PVC cable from S.G. Room to street light supports after digging of trench laying of (2×6)mm2 cable, providing brick on top of cable, refilling of trench, making connections of poles with street light fitting through junction box complete in all respect. |
| 188 | Construction of 11 KV Double Poles :Erection and grouting of 2 Nos. STP 11 M long for making DP Structure including & fabrication fixing of M.S. Channel, M.S. Angle, TPMO (if any), Fuse Set (if any) , disc. insulators, pin insulators etc. The work includes supply and fixing of necessary clamps with nuts, bolts and washers. The work also includes grouting of Double pole support in C.C. 1:4:8 (cement, sand & brick ballast) in block of size (0.45m × 0.45 × 1/6 length of the pole) including earthing of Double pole with M.S. earthing rod complete in all respect. |
| 189 | Erection and installation of 11/0.4 KV, 63 KVA T/F on double pole including shifting of the same on to the double pole and making of 11 KV connections and providing and fixing chemical earthing (GI pipe 50 mm dia , 3 meter long) of transformer neutral complete the work in all respects. |
| 190 | Painting of all steel section mounted on 11 KV Double Pole with one coat of red primer & 02 Nos. coat of ISI Mark Aluminium paint after rubbing with sand paper to the surface of steel section. |
| 191 | Installation of 33 KV Isolators :Assembling and installation of line & Bus Isolator on the isolator structure. Adjusting of operating mechanism in proper alignment so as to ensure smooth operation of the same. In case of Line Isolator proper operation of earth links shall also be ensured. The work includes fabrication for proper fixing if required. |
| 192 | Installation of 33 KV Lightening Arrestors : Assembling and installation/mounting of 3 Nos. lighting arrestors on the L.A.'s structure/terminal gantry, complete with earthing and line connections. The work includes fabrication for proper fixing, if required. |
| 193 | Installation of 33 KV Post Insulators : Installation of 12 nos . PI on PI structure. & on T structure for copper bus bar intallation on T/ F LV side The work includes fabrication for proper fixing, if required. |
| 194 | Installation of 33 KV Fuse Set :installation of fuse set on the fuse set structure. The work includes fabrication for proper fixing, if required. |
| 195 | Installation of 33 KV VCB installation of 33 KV VCB on the VCB out door structure on the plinth. Adjustment of operating mechanism in proper alignment for smooth operation of the same. The work also includes fabrication of addition arrangement for proper fixing, if required. |
| 196 | Installation of 33 KV C.T.'s :(a)Installation of 3 Nos. C.T.'s on the C.T.'s structure. The work includes fabrication for proper fixing, if required to complete the work. |
| 197 | 33 KV CT's Junction Box :Providing & fixing of junction box of size (400 × 400 × 150)mm made of M.S. Sheet of 16 SWG in between 33 KV CT's & control panel. The work also include providing 12 nos. connectors etc. for making proper connection on the junction box and making all connection in between CT's and control panel complete as per manufacture's panel drawing including testing and commissioning of work etc. compete the work. |
| 198 | Installation of 33 KV P.T.s Installation of 3 nos. P.T.s on P.T. Structure. The work includes any fabrication work for fixing, if required to complete the work. |
| 199 | Installation of 33 KV VCB Control PanelCarefully and safely shifting of 33 KV VCB control panel from outside to inside of the switch gear room, grouting with anchor bolts in the floor, work also includes cutting & proper finishing of floor if necessary for completion of work. Placing and fixing of panel on foundation, bolts of proper size in proper position and alignment. |
| 200 | 33 KV Bus Bar Jumpering :(a) Construction of 33 KV Bus Bar Jumpering |
| 201 | (b) Stringing of 33 KV bus bar laying ACSR Dog conductor including fixing of 33 KV Disc Insulators and tension fittings to complete work with proper sagging of Bus Bar etc. |
| 202 | Jumpering, including clamping/binding with ACSR Dog conductor: (including all type clamp required for proper fixing )a) Terminal gantry to 33 KV Line Isolator. |
| 203 | b) 33 KV Line Insulator to 33 KV bus bar through post insulators |
| 204 | c) 33 KV Bus bar to 33 KV Bus Isolator of T/F bay |
| 205 | d) 33 KV Bus Isolator to Post Insulator |
| 206 | e) 33 KV Bus Isolator to 33 KV VCB |
| 207 | f) 33 KV VCB to 33 KV CT |
| 208 | g) 33 KV Bus-Bar to 33 KV PT |
| 209 | h) 33 KV CT to 33 KV Fuse Set |
| 210 | (i) 33 KV Fuse Set to 33/11 KV 05 MVA Power Transformer through 33 KV Lightening Arrestors work includes supply & installation of proper size copper lugs with power Transformer. |
| 211 | Construction of SSO's approached road 1.2 Mtr. wide in Switchyard by laying dry brick ballast in 15 cm layer, 115 mm thick brick work 1:4 in both side of edge, providing 10cm thick CC in ratio 1:2:4. The work include proper plastering top & side of road and making groove, leveling & dressing of earth beneath the brick work on edge. |
| 212 | Leveling & dressing of the Switchyard including cutting up rooting of grass/grass vegetation making proper slope watering & ramming. |
| 213 | Tripping, Single line diagram & 33/11 KV Sub-Station Board :a) Fixing of tripping board of size (1500×900)mm made of Indian plywood of 6 mm thick fitted on wooden frame made of salwood of size (50×38)mm. Two support of size 900mm shall be used on back side of board. The frame of the board shall be tapered on the font side and properly finished. The board shall be painted with black enamel paint in two coats after the one coat of primer. The primer paint shall be used in both side. The prescribed matter shall be written neatly with white enamel paint. |
| 214 | b) Fixing of single line diagram board for 33/11 KV substations of size (1200×900)mm made of Indian Plywood 6 mm thick fitted on wooden frame made of salwood of size (50×30)mm. Two support of salwood of size 1200 mm and two supports of size 900 mm shall be tapered on the front side and properly finished, the board shall painted with white enamel paint in two coats after one coat of primer shall be used in both side. The prescribed matter/chart shall be written neatly with red, green and black paint as required. |
| 215 | c) Fabrication, erection & grouting of 33/11 KV Sub-Station board of size (0.75×1.5)mt, 2.40 mt. high frame of M.S. Angle iron of size (40×40×6)mm, two cross bracing of M.S. Flat of size (25×6)mm shall be fixed with the frame, board shall be mde of 18 SWG M.S. steel of size (0.75×1.5)mt. shall be fitted in frame with Rivet. Letters should be written by black paint on yellow background. |
| 216 | Installation of 33 KV Meter in meter box by fixing on a board of size 300×500mm made of Indian Plywood of 6mm thick |
| 217 | Supply, fabrication, erection & grouting of metering cubical in Control Room, 1.8 Mtr. high frame of M.S. Angle Iron of size 40×40×6mm, two cross bracing of M.S. Flat of size 25×6mm shall be fixed with the frame. Metering cubical shall be made of 18 SWG M.S. Steel of size 320×420mm shall be fitted on frame. |
| 218 | Fabrication & Providing Fire buckets stand size 1.2 mtr. in length and 1.0 mtr. in height made of M.S. Angle iron of size 40×40×6mm having 6 Nos. bucket made of M.S. Sheet 20 Gauge 11 liter capacity having one no. handle at the top of buckets and another at the side of the buckets and painted outer side post office colour and inner side white enamel paint and marked \\"fire\\" in outer side of buckets as per drawing. |
| 219 | Construction of Fire Wall ( as per specification) |
| 220 | Testing & commissioning of substation equipmets like VCBs, CTs, PTs,panels,transformers etc.ETC. |
| 221 | Painting of Sub-Station Structure & Equipment |
| 222 | Survey and Lay out of Sub-Station |
| 223 | Erection of Following materialA- Erection of support after excavation of foundation pit in mix soil/normal soil/soft & hard rock and its back filling and leveling etc. The size of the pit will be (900×600)mm and having depth of 1/6th of the full length of the support & Erection of support. The work includes carriage and handling of supports from site store to pit site.(i) 11 Mtr. P.C.C. Poles |
| 224 | (ii) 13 Mtr Long STP, SP-72 Round Pole |
| 225 | (iii) 8.5 Mtr. P.C.C. Poles |
| 226 | B- Fixing of all clamps, Cross Bracing Sets 3.5 Mtr. from M.S. Angle 65×65×6mm/50×50×6mm & other accessories on the supports as per drawing. Work includes cutting of holes and providing M.S. Bolts of 16×40mm size in the middle of cross bracing with 1 no. spring washer. The work also includes carriage & handling of accessories from sectional store to pit site as well as any fabrication work if required.(i) Single Pole Structures(a) 11 Mtr. P.C.C. Poles |
| 227 | ( b) 13 Mtr Long STP, SP-72 Round Pole |
| 228 | (c.) 8.5 Mtr. P.C.C. Poles |
| 229 | (ii) Double Pole Structures (a) 11 Mtr. P.C.C. Poles |
| 230 | b) 13 M Long STP, SP-72 Round Pole |
| 231 | (c.) 8.5 Mtr. P.C.C. Poles |
| 232 | (iii) TRI Pole Structures (a) 11 Mtr. P.C.C. Poles |
| 233 | b) 13 M Long STP, SP-72 Round Pole |
| 234 | (c.) 8.5 Mtr. P.C.C. Poles |
| 235 | (iv) Four Pole Structures (a) 11 Mtr. P.C.C. Poles |
| 236 | b) 13 M Long STP, SP-72 Round Pole |
| 237 | (c.) 8.5 Mtr. P.C.C. Poles |
| 238 | Providing and Grouting of supports in CC 1:4:8 (Cement, sand & 40 mm brick ballast) Grouting will be done in the block of size (450×450)mm ×1/6th of full length of the support, up to ground level, 300 mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grit) with muffing as per drawing, work includes back filling and proper ramming.(i) 11 Mtr. P.C.C. Poles |
| 239 | (ii) 13 Mtr Long STP, SP-72 Round Pole |
| 240 | (iii) 8.5 Mtr. P.C.C. Poles |
| 241 | Providing and Grouting of stay rods (16×1800)mm including all work of excavation, cement concrete in size (0.60 × 0.60 × 0.30)m in ratio 1:4:8 cement, sand, 40mm brick ballast) as per drg. including back filling, proper ramming etc and fixing tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing. |
| 242 | Earthing of supports with MS earth Rod of (20×2500)mm long including excavation of pit and driving M.S. Rod 3.0 M apart from support and 0.5m below the ground level and connecting below the earth electrodes with the help of G.I. wire no. 8 SWG and earthing lugs. |
| 243 | Laying, spreading, lifting and final sagging of 3 phases of ACSR Dog conductor in accordance with profile and sag chart including binding, Jumpering and fixing of P.G. Clamp as per requirement in 03 Nos. conductor in parallel. |
| 244 | Fixing of danger board at each location as per specification of the drawing with clamps etc. |
| 245 | Fixing of Number plate at each location as per specification of the drawing with clamps etc. |
| 246 | Chopping of branches of trees of eucalyptus, Neem, Keekar and other kind of trees along the route of the line and disposal of the same at suitable place. |
| 247 | Making H.T. Connections of the proposed line, on to the existing 33 KV bay/line from where line is eminating and another at the end of line to the terminal gantry at proposed 33 KV Sub-station. The work consists of fixing of tension fitting, insulators, jumpering, clamping and binding etc. at the end as per site conditions. |
| 248 | Painting of following supports/structures with 2 coats of synthetic enamel paint after one coat of ready mix primer including cost of all material, as well as rubbing/cleaning of surface as required for proper completion of work. Painting will be done by post office red paint from top to cross arm and remaining by Aluminium paint.(a) 13 Mtr, SP-72 Poles including all channels/X-Arms/Clamps etc.(i) Single supports |
| 249 | (ii) Double Pole supports |
| 250 | (iii) TRI Pole supports |
| 251 | (iv) Four Pole supports |
| 252 | (b) All channels/X-Arms/Clamps / OH cable fitting etc. of 11 Mtr, long PCC Poles (i) Single supports |
| 253 | (ii) Double Pole supports |
| 254 | (iii) TRI Pole supports |
| 255 | (iv) Four Pole supports |
| 256 | (c) All channels/X-Arms/Clamps, OH cable fitting etc. of 8.5 Mtr, long PCC Poles (i) Single supports |
| 257 | (ii) Double Pole supports |
| 258 | (iii) TRI Pole supports |
| 259 | (iv) Four Pole supports |
| 260 | Wrapping of barbed wire on 33 KV PCC Poles/SP-55 ST & SP-72 ST Poles as anti-climbing device for a length of 0.9 Mtr., wire pitch/gap 13mm and fixing upper and lower end keeping lower end at a height of 2.75 Mtr. from the ground complete with supply and fixing of lower end & upper end clamps made of M.S. Flat 40×5mm complete with nuts & bolts & all other required material. |
| 261 | Guarding between two poles like single poles, double poles, four poles, etc. to guard LT, 11 KV Line telephone and river crossing, road crossing etc. with G.I. wire no. 6 SWG and G.I. wire no. 8 SWG, including cutting with fabrication and fixing of guarding channel with clamps nut & bolts etc. as per drawing. |
| 262 | Laying of 33 KV & 11 KV Cable in Air |
| 263 | Digging & laying of 33 KV & 11 KV Cable in tranch with sand & brick with loop |
| 264 | Laying of HDPE Pipe PE-80, PN-6, DN-160mm dia Pipe for laying of 33KV, 3x300Sq.mm, XLPE Cable with HDD (trenchless) method including cablelaying. |
| 265 | Overhead laying of 11KV 3X185mm² XLPE cable on structure mount on pole and clamping and fitted it properly |
| 266 | Making of appropriate structure through 1.2 mtr long 100x50x 6 mm channel , using with 2 bracing angle 65x65x6 mm for support of 1 mtr length each , and mount it on pole . |
| 267 | Making of 33 KV, 3x300 sq mm cable J/kit & 11 KV 3x185 sq mm cable J/kit |
| 268 | Road restoration charges for Kuccha Road (Inter locking Tiles, Bricks Road & Developed green belt only). (33 KV Line) |
| 269 | Road restoration charges for Pucca Road (Cemented, Concrete & Black road only). (33 & 11 KV Line) |
| 270 | Fixing of cable route marker along the route of 33KV cable. (33 & 11 KV Line) Total in Figures 0.0 0.0 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select % 0.0 0.0 Zero Only Quoted Rate in Words Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail