|
| 1 | Carriage of followings from ESC BSR to pit site on kachcha pakkaa road including loading and unloading chagres at both ends, required completion of work, distance about to 0 to 70 Km. approx. |
| 2 | PCC 8.5 Mtr. Long. |
| 3 | STP 13 Mtr. Long. |
| 4 | PCC 11 Mtr. Long. |
| 5 | 11/0.4 KV T/F 400 KVA |
| 6 | 11/0.4 KV T/F 250 KVA |
| 7 | 11/0.4 KV T/F 63 KVA |
| 8 | 11/0.4 KV T/F 10 KVA |
| 9 | 11 KV TPMO |
| 10 | 11 KV Fuse Set |
| 11 | 11 KV Cross arm |
| 12 | 33 KV Cross arm |
| 13 | 33 KV Polymeric Pin Insulator |
| 14 | 11 KV Polymeric Pin Insulator with Pin |
| 15 | 11 KV Polymeric Pin Insulator |
| 16 | 11 KV Polymeric disc insulator with fitting |
| 17 | 11 KV Disc Insulator T&C type 4500 Kg. |
| 18 | 11 KV Disc Fitting. |
| 19 | 33 KV Polymeric disc insulator |
| 20 | 33 KV Polymeric disc Fitting |
| 21 | 11 KV Stay Set Complete |
| 22 | Stay Set Complete |
| 23 | LT ABC 3x95+1x70+1x16 Sq mm |
| 24 | LT ABC 3x120+1x95+1x16 Sq mm |
| 25 | Dog Conductor |
| 26 | ACSR Weasel Conductor |
| 27 | ACSR Rabbit Conductor |
| 28 | LT XLPE Cable AL 1x400 Sq mm |
| 29 | LT XLPE Cable AL 3.5x400 Sq mm |
| 30 | 11 KV XLPE Cable AL 3x120 Sq mm |
| 31 | 11 KV XLPE Cable 3x185 Sq mm |
| 32 | LT PVC Cable Al 1x400 Sq mm |
| 33 | LT PVC Cable 3.5x70/35 Sq mm |
| 34 | LT PVC Cable Al 1x240 Sq mm |
| 35 | Stay Wire |
| 36 | Danger Board Barbed wire Including Jumper |
| 37 | 11 KV Jointing Kit Outdoor 3x120 Sq mm |
| 38 | 11 KV Jointing Kit Indoor 3x120 Sq mm |
| 39 | 11 KV Jointing Kit Outdoor 3x185 Sq mm |
| 40 | 11 KV Jointing Kit Indoor 3x185 Sq mm |
| 41 | Distribution Box |
| 42 | Distribution Box Clamp |
| 43 | The following material Erection & Fixing as per RESPO manual and as per direction fo Supervising Engineer. It includes the cost of labour, T&P, Carrier etc. required for proper completion of work. |
| 44 | PCC 8.5 Mtr. Long. |
| 45 | STP 13 Mtr. Long. |
| 46 | PCC 11 Mtr. Long. |
| 47 | 11/0.4 KV T/F 400 KVA |
| 48 | 11/0.4 KV T/F 250 KVA |
| 49 | 11/0.4 KV T/F 63 KVA |
| 50 | 11/0.4 KV T/F 10 KVA |
| 51 | 11 KV TPMO |
| 52 | 11 KV Fuse Set |
| 53 | 11 KV Cross arm |
| 54 | 33 KV Cross arm |
| 55 | 33 KV Polymeric Pin Insulator |
| 56 | 11 KV Polymeric Pin Insulator with Pin |
| 57 | 11 KV Polymeric Pin Insulator |
| 58 | 11 KV Polymeric disc insulator with fitting |
| 59 | 11 KV Disc Insulator T&C type 4500 Kg. |
| 60 | 11 KV Disc Fitting. |
| 61 | 33 KV Polymeric disc insulator |
| 62 | 33 KV Polymeric disc Fitting |
| 63 | 11 KV Stay Set Complete |
| 64 | Stay Set Complete |
| 65 | LT ABC 3x95+1x70+1x16 Sq mm |
| 66 | LT ABC 3x120+1x95+1x16 Sq mm |
| 67 | Dog Conductor |
| 68 | ACSR Weasel Conductor |
| 69 | ACSR Rabbit Conductor |
| 70 | LT XLPE Cable AL 1x400 Sq mm |
| 71 | LT XLPE Cable AL 3.5x400 Sq mm |
| 72 | 11 KV XLPE Cable AL 3x120 Sq mm |
| 73 | 11 KV XLPE Cable 3x185 Sq mm |
| 74 | LT PVC Cable Al 1x400 Sq mm |
| 75 | LT PVC Cable 3.5x70/35 Sq mm |
| 76 | LT PVC Cable Al 1x240 Sq mm |
| 77 | Stay Wire |
| 78 | Danger Board Barbed wire Including Jumper |
| 79 | 11 KV Jointing Kit Outdoor 3x120 Sq mm |
| 80 | 11 KV Jointing Kit Indoor 3x120 Sq mm |
| 81 | 11 KV Jointing Kit Outdoor 3x185 Sq mm |
| 82 | 11 KV Jointing Kit Indoor 3x185 Sq mm |
| 83 | Distribution Box |
| 84 | Distribution Box Clamp |
| 85 | Providing & Fixing of the following material by the Contractor as perUPPCL/RESPO Rules. |
| 86 | Stone Pad |
| 87 | Concreting of Pole |
| 88 | Nut & Bolt |
| 89 | Concreting of Stay |
| 90 | Plinth for 250 KVA TF |
| 91 | FRC Fencing (6 Feet height including civil work |
| 92 | Henley type Tailless unit protection Cubical Panel 500 A 650 V |
| 93 | Suspension Clamp |
| 94 | Dead End Clamp |
| 95 | PRC Connector |
| 96 | J-Hook |
| 97 | Clamps for LT T-off with bolts & Nuts |
| 98 | Holding Clamps for top Channel TPMo & Fuse set etc. |
| 99 | Number Plate with Clamp |
| 100 | Danger Board with Clamp |
| 101 | F-Bracket 11 KV for fitting top insulator with Nut & Bolt |
| 102 | 11 KV F-Clamp |
| 103 | Cross Arm Holding Clamp with nut and Bolt |
| 104 | Earthing of pole by MS Earthing rod of 20x2500 mm and 6 swg earthing |
| 105 | LT Fuse Set Protection Unit for 63 KVA DT with SMC Box |
| 106 | LT Incoming Panel with metering equipment & Fixing |
| 107 | Copper L-Piece 50x225x10 mm (LS) |
| 108 | Copper L-Piece 62x225x12 mm (LS) |
| 109 | AI Lug Long barrel off size (LS) |
| 110 | 4 Core LT MCB with box (LS) |
| 111 | MS Dropper Channel 100x50x2028 mm for Fuse Set |
| 112 | MS Top Channel (125x65x2240)mm |
| 113 | T-off Channel |
| 114 | MS Channel 125x65x1300)mm (T-off) |
| 115 | MS Angle 75x75x6x2028 mm with Clamp, Bolt and Nut for TF Base |
| 116 | TF Earthing |
| 117 | The following material dismantling & carriage from site to ESC BSR including loading and unloading charges at both ends, required completion of work, distance about to 0 to 70 Km. approx. |
| 118 | Dog Conductor scrap |
| 119 | Aluminium scrap |
| 120 | Iron scrap |
| 121 | ABC CABLE |
| 122 | ACSR WEASEL SCRAP |
| 123 | OLD & USED 100 KVA TF |
| 124 | OLD & USED 250 KVA TF |
| 125 | All work will be done as per UPPCL/RESPO Rules. Please Enable Macros to View BoQ information |