| 1 | fo|qr forj.k [k.M&[kqtkZ] ds fctusl Iyku ;kstuk 2026&27 ds vUrxZr [email protected] ifjorZdksa dh vfFkZax] ttZj ykbZu cnyuk] yEcs LiSuksa esa iksy yxkuk] forj.k ifjorZdksa ij izkSVsD'ku yxkus] 11 dsoh vfrfjDr ykbZu cukus] 11 ds0oh0 oh0lh0ch0 LFkkfir djus laca/kh dk;ZA |
| 2 | DESCRIPTION OF WORK/ITEM (S) |
| 3 | Safe carriage of store material from store center to Pit site with loading & unloading at both ends respectively without contractor porvading all item etc. distance within- 0 to 50 Km |
| 4 | PCC Poles 11 mtr. long |
| 5 | PCC Poles 8.5 mtr. long |
| 6 | Safe carriage of store material from store center to JE Store/Sub Station with loading & unloading at both ends respectively without contractor porvading all item distance within- 0 to 50 Km |
| 7 | ACSR Weasel Conductor |
| 8 | ACSR RABBIT CONDUCTOR |
| 9 | LT ABC 3*50 sq mm |
| 10 | LT ABC 3*95 sq mm |
| 11 | LT ABC 3*120 sq mm |
| 12 | 33 KV XLPE CABLE (3X300) sq.mm |
| 13 | GI WIRE 6 SQ GAGE |
| 14 | GI WIRE 8 SQ GAGE |
| 15 | 11 KV V TYPE CROSS ARM |
| 16 | 11 KV VCB N/G CTR 200/100/5 |
| 17 | 1*240 SQ MM SINGLE LEAD |
| 18 | 1*400 SQ MM SINGLE LEAD |
| 19 | 1*120 SQ MM SINGLE LEAD |
| 20 | 1*70 SQ MM SINGLE LEAD |
| 21 | 1*35 SQ MM SINGLE LEAD |
| 22 | LIGHTENING ARRESTOR |
| 23 | 11 KV VCB N/G CTR 600/300/5 |
| 24 | EARTHING ROD |
| 25 | 11 KV Pin Insulater |
| 26 | 11 KV Disc Insulater with disc fitting |
| 27 | battery set 24 v |
| 28 | battery charger 24 v |
| 29 | 33 KV CT 400/200/1 |
| 30 | LT XLPE Cable AL. 3.5X50 sq.mm |
| 31 | LT XLPE Cable AL. 3.5X70 sq.mm |
| 32 | Cable AL. 3X185 sq.mm XLPE 11 KV |
| 33 | Loading, Safe carriage & unloading of heavy stock material channel, Angle and other site requerment any mattrial ETC from store center to JE Store/Sub Station with proper stacking of material, distance within 30 Kms. |
| 34 | Safe carriage of store material from JE Store/Sub Station to Pit site as per site requirtement with loading & unloading at both ends respectively without contractor porvading all item distance within- 0 to 30 Km |
| 35 | ACSR Weasel Conductor |
| 36 | ACSR RABBIT CONDUCTOR |
| 37 | LT ABC 3*50 sq mm |
| 38 | LT ABC 3*95 sq mm |
| 39 | LT ABC 3*120 sq mm |
| 40 | 33 KV XLPE CABLE (3X300) sq.mm |
| 41 | 11 KV V TYPE CROSS ARM |
| 42 | LIGHTENING ARRESTOR |
| 43 | 11 KV VCB N/G CTR 200/100/5 |
| 44 | 11 KV VCB N/G CTR 600/300/5 |
| 45 | 1*240 SQ MM SINGLE LEAD |
| 46 | 1*400 SQ MM SINGLE LEAD |
| 47 | 1*120 SQ MM SINGLE LEAD |
| 48 | 1*70 SQ MM SINGLE LEAD |
| 49 | 1*35 SQ MM SINGLE LEAD |
| 50 | EARTHING ROD |
| 51 | 11 KV Pin Insulater |
| 52 | 11 KV Disc Insulater with disc fitting |
| 53 | 33 KV CT 400/200/1 |
| 54 | PCC Poles 11 mtr. long |
| 55 | PCC Poles 8.5 mtr. long |
| 56 | LT XLPE Cable AL. 3.5X50 sq.mm |
| 57 | LT XLPE Cable AL. 3.5X70 sq.mm |
| 58 | Cable AL. 3X185 sq.mm XLPE 11 KV |
| 59 | Loading, Safe carriage & unloading of heavy stock material channel, Angle and other site requerment any mattrial ETC from JE Store/Sub Station to Pit site as per site requirement with proper stacking of material, distance within 30 Kms. |
| 60 | Erection of Single pole all size as per RESPO Drawing, fitting with all accessories Pin Insulator, F Bracket and etc as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work. |
| 61 | PCC Poles 11 mtr. long |
| 62 | PCC Poles 8.5 mtr. long |
| 63 | Excavation of For Each and grouting of Single Pole as per RESPO Drawing and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. The support shall be grouted with cement, sand and stone ballast in ratio 1:4:8 including the cost of Cement, Sand, Stone Ballast, Stone Pad etc. as per actual site requirement |
| 64 | PCC Poles 9/11/13 mtr. long |
| 65 | PCC Poles 8.5 mtr. long |
| 66 | Erection of Dobule Pole all size as per RESPO Drawing, fitting with all accessories Pin Insulator, F Bracket and etc as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work. |
| 67 | PCC Poles 8.5 mtr. long |
| 68 | Excavation of For Each and grouting of Dobule Pole as per RESPO Drawing and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. The support shall be grouted with cement, sand and stone ballast in ratio 1:4:8 including the cost of Cement, Sand, Bricks/Stone Ballast, etc. as per actual site requirement |
| 69 | 9.2 PCC Poles 8.5 mtr. long |
| 70 | Laying sagging stringing and binding and jumpering etc of following Conductor/ABC/XLPE of size on the newly erected poles as per RESPO manual and as per direction of Supervising Engineer. It includes the cost of labour, T&P, carrier etc. required for proper completion of work. |
| 71 | 33 KV XLPE CABLE (3X300) sq.mm |
| 72 | ACSR Weasel Conductor |
| 73 | ACSR RABBIT CONDUCTOR |
| 74 | LT ABC 3*120 sq mm |
| 75 | LT ABC 3*95 sq mm |
| 76 | LT ABC 3*50 sq mm |
| 77 | LT XLPE Cable AL. 3.5X50 sq.mm |
| 78 | LT XLPE Cable AL. 3.5X70 sq.mm |
| 79 | Cable AL. 3X185 sq.mm XLPE 11 KV |
| 80 | 1*240 SQ MM SINGLE LEAD |
| 81 | 1*400 SQ MM SINGLE LEAD |
| 82 | 10.13 1*120 SQ MM SINGLE LEAD |
| 83 | 10.14 1*70 SQ MM SINGLE LEAD |
| 84 | 10.15 1*35 SQ MM SINGLE LEAD |
| 85 | Providing and fixing of Barbed wire. |
| 86 | Fixing of earthing rod and Wire as per RESPO manual and as per direction of supervising engineer including the cost of labour, T&P etc. required for proper completion of work. |
| 87 | Cutting/drilling/Welding of MS Channel Top Channal, site channel, site angle, Dropper Channal & Cross brassing angle and MS mattriel Including the work of fixing on STP Pole for construction of the line. |
| 88 | Making Jumpers on Section Points, by fixing of proper sizes, suitable for ACSR Conductor. Sectional Double/Four Pole. |
| 89 | Mounting of 11 KV VCB N/G CTR 200/100/5 Sub Station to Control Room by Hydra and manual Labour. |
| 90 | Fixing/Installaiton of 11 KV VCB N/G CTR 600/300/5 |
| 91 | Fixing/Installaiton of 11 KV VCB N/G CTR 200/100/5 |
| 92 | Fixing of 11 KV V TYPE CROSS ARM |
| 93 | Fixing of 11 KV Pin Insulater |
| 94 | Fixing of 11 KV Disc Insulater |
| 95 | Providing of Three Phase Distribution Box Direction of Engineer incharge |
| 96 | Fixing of Three Phase Distribution Box |
| 97 | Providing of G.I Pipe 6 inch dia |
| 98 | Fixing of G.I Pipe 6 inch dia |
| 99 | Chopping of branches of trees of eucalyptus, Neem, Keekar and other kind of trees along the route of the line and disposal of the same at suitable place. |
| 100 | Providing and Fixing of Chemical Earthing |
| 101 | Providing and Fixing of GI Strip for earthing regarding |
| 102 | Providing and fixing of Water Level Earthing |
| 103 | Providing and fixing copper coin, copper wire with strip/hook purpose for water level earthing |
| 104 | Providing and fixing of Lug BRASS 250 kva |
| 105 | Fixing of 33 KV CT 400/200/1 |
| 106 | PROVIDING HDD PIPE 200MM DIA |
| 107 | LISENING N0C CHARGES OF RAILWAYS |
| 108 | Laying of HDPE Pipe through HDD Method Trenchless on Road.as per site required direction of Engineer incharge |
| 109 | Digging of Pits Of Size 4 Mtr X 4 Mtr X 1.5 Mtr. For Cable Loop |
| 110 | Restoration of Pit After Laying Of Cable loop |
| 111 | Hoisting of 11 KV 3X185 Sq mm XLPE Cable On Double Pole Structure through GI Pipe 140 MM dia 3 Mtr Long Fixed On Pole Structure Including its Jumpring Complete with Clamps Bolts and |
| 112 | Providing & Fixing and Interconnecting 6 Mtr. Long Pieces of HDPE Pipe shocket. |
| 113 | Laying And Pulling of 11 KV XLPE Cable Off size Throug HDPE Pipe |
| 114 | Road Restoration kachha work |
| 115 | Road Restoration Pakka work |
| 116 | Providing of 11 KV XLPE Cable Jointing Kit off size 3X185 |
| 117 | Fixing of 11 KV XLPE Cable Jointing Kit off size |
| 118 | Providing of 33 KV XLPE Cable Jointing Kit off size 3X300 |
| 119 | Fixing of 33 KV XLPE Cable Jointing Kit off size 3X300 |
| 120 | HOLDING CLAMP |
| 121 | CLAMP FOR CROSS ARM |
| 122 | F CLAMP WITH NUT BOLT |
| 123 | PERCING Clamp |
| 124 | LT CLAMP FOR PCC POLE |
| 125 | SUSPENSION CLAMP FOR LT ABC |
| 126 | DEAD END CLAMP FOR LT ABC |
| 127 | NUT & BOLT |
| 128 | MS CHANEL, ANGEL, DROPER, |
| 129 | STONE PAD |
| 130 | WTI/ OTI |
| 131 | STATIC RELAY |
| 132 | all lug 35 sqmm |
| 133 | all lug 70 sqmm |
| 134 | all lug 120 sqmm |
| 135 | all lug 240 |
| 136 | earth wire cllamp with nut bolt |
| 137 | connecting lead 1x16 sq mm |
| 138 | lt shackle insulator |
| 139 | Dismantling and removing of old VCB |
| 140 | Carrige of all dismantle material site/substation to store center BSR. Please Enable Macros to View BoQ information |