| 1 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for Complete all as specified and directed. |
| 2 | M&L for laying PCC (1:4:8) type D2 (using 40mm graded aggregate) for sub base and mass concrete in foundation complete all as specified and directed. |
| 3 | M&L for 75mm thick PCC (1:3:6) type C2 using 40mm graded aggregate as in plinth protection including finishing even and smooth with using extra cement, complete all as specified and as directed. |
| 4 | M&L for 40 mm thick cement concrete type B1 1:2:4 (20 mm graded stone aggregate) in wearing course/padding concrete complete all as specified and as directed. |
| 5 | Material and labour for PCC (1:3:6) type C2 using 40mm graded aggregate as in surface channels and drain, complete all as specified and as directed. |
| 6 | M&L for Heavy duty vitrifired coloured tiles 400x400x10 mm thick each of tiles in floor/steps/stairs etc set jointed and pointed in neat cement slurry in floors incl 15mm thick screed in CM 1:4 complete all as specified and directed |
| 7 | Demolition of precast concrete work/ block walling built in cement mortar complete all as directed. |
| 8 | Material and labour for PCC solid block masonry (1:3:6) (using 20mm graded stone aggregate) straight or curved on plan exc 6m mean radius, exc 10cm in width and built in CM (1:6) complete all as specified and as directed |
| 9 | Taking down cement plaster on brick or stone wall and racking out joints hacking for key sucrubing down with water etc. complete all as specified and directed. |
| 10 | M & L for rendering 10 mm thick in cement mortar 1:4 on concrete or brick masonry surfaces finishing the top surface even and fair without using extra cement complete all as specified and as directed |
| 11 | M & L for preparation of surface and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of WHITE Colour required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. all as directed by the Engineer-in-charge and as per manufacturers instructionsMake: Asian Paints (Apex Ultima), Berger (Weathercoat Long Life Flexo) Nerolac (Excel Total). Shalimar Paints (Weatherpro+ Super Luxury Emulsion).Note: Rate inclusive of scaffolding at any height. |
| 12 | M & L for preparation of old surfaces and applying one coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal esistance, dirt resistance exterior paint of WHITE COLOUR with silicon additives coat applied @ 1.67 ltr/10 sqm over complete all as specified and as directed by Engineer-in-charge.Make: Asian Paints (Apex Ultima), Berger (Weathercoat Long Life Flexo) Nerolac (Excel Total). Shalimar Paints (Weatherpro+ Super Luxury Emulsion).Note: Rate inclusive of scaffolding at any height. |
| 13 | M & L for preparation of old surfaces and applying one coat of 100% Premium acrylic emulsion paint (company depot tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal esistance, dirt resistance exterior paint with silicon additives coat applied @ 1.67 ltr/10 sqm over complete all as specified and as directed by Engineer-in-charge.Make: Asian Paints (Apex Ultima), Berger (Weathercoat Long Life Flexo) Nerolac (Excel Total). Shalimar Paints (Weatherpro+ Super Luxury Emulsion).Note: Rate inclusive of scaffolding at any height. |
| 14 | M&L Preparing old steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed |
| 15 | M&L for plain cement concrete type B1 (1:2:4) using 20mm graded stone aggregate as in copings cavings, bed plats and embeding swan neck fencing post, etc incl weathering slightly rounded or chamfered angles and throating as directed complete all as specified and directed. |
| 16 | M&L for preparing bituminous surfaces of road and marking 2.5mm thick center lines,stop lines,dashes,arrows etc.and the like n. exc 10cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and directed by the Engineer-in-Charge. |
| 17 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 18 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as manufacturers instruction and as directed. |
| 19 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as in ridges, hips, valley gutter, drip, and straight flashing complete all as specified and as directed |
| 20 | S & F in repairs Aluminium flat iron work in, wind ties screwed as directed, including all necessary drilling, bolting or riveting etc., and similar work complete all as specified and as directed |
| 21 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed |
| 22 | Excavating in post holes in hard/dense soil n.exc. 0.5 cum and getting out returning, filling in and ramming in layers n.exc. 25 cm, watering and removing surplus soil to a distance n.exc. 50 mtr and making good the surface complete all as specified and as directed |
| 23 | S&F MS Roof trusses (Framed), trussed, purlins, rafters, crane gantries, rails ,posts and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc.including necessary welding confirming to Fe-410-W(Gde-E250 quality-A) complete all as specified and as directed. |
| 24 | M&L Preparing new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed |
| 25 | Demolition of Concrete of any description and in any position (reinforcement cut as required to facilitate demolition) not otherwise specifically provided for cement concrete is reinforced complete all as specified and directed. |
| 26 | Rough Excavation over areas n.exc. 1.5M deep and getting out as in loose/soft soil complete all as specified and directed. |
| 27 | Excavation over areas n.exc. 1.5M deep and getting out as in loose/soft soil complete all as specified and directed. |
| 28 | Excavation over areas exc. 1.5m and n. exc 3.0 m deep and getting out soft/loose Soil complete all as specified and directed. |
| 29 | M&L RCC M30 grade (Nominal Mix) using 20mm graded stone aggregate as in foundations including rafts, footings, foundation beams, plinth beams; bases for coloumns, etc basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 30 | M&L RCC M30 grade (Nominal Mix) using 20mm graded stone aggregate as in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footing including attached pilasters and buttresses complete all as specified and directed. |
| 31 | M&L for use and removal of steel form work to sides of concrete foundations, footings,rafts and raft beams sides and soffits of foundation and plinth beams and similar work for flat surface complete all as specified and directed. |
| 32 | M&L for use and removal of steel form work to faces of walls retaining walls, abutments, parapets and like for flat rough fineshed surface complete all as specified and directed. |
| 33 | M&L for use and removal of steel form work to faces of walls retaining walls, abutments, parapets and like for flat fair fineshed surface complete all as specified and directed. |
| 34 | M&L for TMT bars 10mm dia and over cut to length, bent to shape required incl cranking, bending, spirally for hooping for columns, hooking end and binding with and incl mild steel wire not less than 0.9mm dia or securing with clip quality confirming to deformed or twisted bars complete all as specified and directed. |
| 35 | M&L for TMT bars 6 to 8mm dia, bent to shape required incl cranking, bending, spirally for hooping for columns, hooking end and binding with and incl mild steel wire not less than 0.9mm dia or securing with clip quality confirming to deformed or twisted bars complete all as specified and directed. |
| 36 | M&L Boulder filling dry, handpacked tightly, as in wire crate apron bunds (Wire crate measured separately) complete all as specified and directed. |
| 37 | S & F PVC pipe 110mm dia as in weep holes complete all as specified and directed. |
| 38 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 39 | Back filling of Moorum/Soil in reataining wall or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 40 | Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 41 | M&L for 30mm thick FRP moulded grating with opening not Exc 30mm x 30mm not less than 6 mm thick framed in bonded material any colour complete fixed todrains after repairing the edges and directed by Engr-in-Charge Note :- Repairs to drain shall be measured and paid seperately |
| 42 | Dismantling fencing wire mesh any type complete all as directed. |
| 43 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in & raming earth/ broken rubble mixed with earth around, in layers n. exc. 25cm, watering, & removing surplus soil to a distance n exc 50m & making good surface in soft/loose soil complete all as specified and directed. |
| 44 | M&L PCC in foundations, filling and mass-concrete type B2 (1:2:4) using 20 mm graded stone aggregate complete all as specified and directed. |
| 45 | S&F MS framed work such as fencing post including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 46 | Supply only MS flat iron as in fillets for securing wire mesh including all necessary drilling, bolting or riveting etc., and similar work confirming to Fe-410 W(Gde-E-250) quality-A complete all as specified and directed. |
| 47 | M&L PVC coated GI chain link fencing 3.5mm dia with 50mm x 50mm mesh including fixing of MS line wire / rod, flat iron & machine made hexagonal or square head bolts to fencing posts complete all as specified.(supply only of MS rod and bolts will be measured and paid seperately) complete all as specified and directed. |
| 48 | Supply only mild steel screw bolts n exc 12 mm dia machine made with hexagonal or square head at one end and screwed the other or screwed both ends for fixing of chain link fencing complete all as specified and directed. |
| 49 | M&L Preparing new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Please Enable Macros to View BoQ information |