| 1 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. |
| 2 | 3 x 2.5 sq.mm |
| 3 | 3 x 4 sq.mm |
| 4 | 3 x 6 sq.mm |
| 5 | 6 x 6 sq.mm |
| 6 | Supplying and fixing following size/modules GI box along with modular base and cover plate for modular switches in recess etc as reqd. |
| 7 | 6 Module (200mmX75mm) |
| 8 | 8 Module (125mmX125mm) |
| 9 | 12 Module (200mmX150mm) |
| 10 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 11 | 5/6 amps switch |
| 12 | 3 pin 5/6 amps socket outlet |
| 13 | 15 /16 amps switch |
| 14 | 6 pin 15/16 amp socket outlet |
| 15 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with cable sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 16 | Group C |
| 17 | Supplying and fixing suitable size G.I. box with modular plate and cover in front or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB \\"C\\" curve including connections, painting etc. as required. |
| 18 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed heavy class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 19 | Group C |
| 20 | Supplying and fixing of Medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 21 | 25 mm dia |
| 22 | Supplying and fixing 2 module stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as reqd. |
| 23 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 24 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 25 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 26 | Brush Less Direct Current (BLDC) Fan without Remote 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 27 | Supply and fixing of suitable size G.I. box with modular plate and cover on front or surface in recess including providing and fixing 6 pin 5/6 & 15/16A modular socket outlet and 15/16A modular switch, connection etc.as required. |
| 28 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 29 | 12 way (4 + 36), Double door |
| 30 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of single pole MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 31 | Single pole |
| 32 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. asrequired. |
| 33 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 34 | 100 amps |
| 35 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 36 | 3.5c X 120 sq. mm |
| 37 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, refilling the trench etc as required. |
| 38 | Upto 35 sqmm |
| 39 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 40 | 4 X 16 sq. mm (28mm) |
| 41 | Supply, Installation, testing and commissioning of pre-wired, double box type fitting with two no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 2xT-LED 22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm |
| 42 | Supply, Installation, testing and commissioning of pre-wired, single box fitting with one no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 1xT-LED 22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm |
| 43 | Dismantling of ceiling fan/exhaust fan/Light fittings etc. including disconnection of wires/cable and submission of same in department store etc. complete as required. |
| 44 | S/F snap-in DLP trunking of 105 mm X 50 mm with suitable cover on the existing wall/ surface i/c having all the accessories such as flat angle, end caps, internal/ external angle etc. as required at site. |
| 45 | Supply, Installation,testing and comissioning of 15 inch heavy duty, AC, Single Phase 230 Volt, 50 Hz, 1350 RPM, steel body exhaust fan in the existing opening, including, making good the damage, cable connection etc. as required |
| 46 | Detection of fault in LT underground cable of all size with FLC Machine which includes pin pointing of fault, disconnection of cable from both end complete as required. |
| 47 | For First Fault |
| 48 | supply of one number PVC insulated and PVC sheathed / XLPE aluminium conductor armoured power cable of 1.1 KV grade of following size etc. as required. |
| 49 | 4c x 16 sqmm |
| 50 | Supply, Installation, testing and commissioning of one no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm in existing single box or double box fittings complete as required. Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm Please Enable Macros to View BoQ information |