| 1 | Supplying , installation , testing and commissioning of cubical type panel with size (2.2x1.3x0.4 Mtr) suitable for operation at 415 (+/-) 6% Volts,50Hz,3 Phase 4 Wire system made out from CRCA sheet steel 2.0 mm and covers shall be cold rolled sheet thickness not less than 1.6mm fabricated factory finished followed-42 by powder coated painting & provided with gaskit to make dust , damp and vermin proof degree of IP 67 , hinged type openable door , loaking arrangement , detachable gland plate , connection , interconnections with suitable size (400 Amp capacity) 4 strip high conductivety elctrical aluminium (ALU) busbar codifies in red,yellow,blue and black colour and PVC insulated copper conductor cable 1100Volt grade for internal wiring including providing and fixing digital type Ampere meter, Voltmeter, Indication LED lamp, Selector switch,Labeling comprise white letters on black background, cable alleys, cable gland plates in two half, etc. necessary metering protections & indications and mounted complete as required including foundation works as required with following switch gears etc:-(Confoming to relevent BIS/IS standard or equivalent) 1) MCCB 250Amps 4 Pole 36KA with thermomagnetic release (incomer) with 1.1) 1 no. 0-500V 96 sqmm digital multifunction meter with selector switch for indicating V, A, pf, F, KW, KVA, KWH, KVAH etc. 1.2) 3 No. phase indicating lamps to show the incoming power with 2A TP MCB for protection.1.3) 2 Nos. indicating lights for incomer on/ trip position. 1.4) 1 No. Phase Reversal relay with matching cast resin CTs and alarm. 1.5) 1 no. 3 phase voltage monitoring relay cum phase sequence meter2) MCCB 100Amps 4 Pole 30KA-6 with thermomagnetic release3) MCCB 63Amps 4 Pole 25KA-2 with thermomagnetic release4) MCB DP 40 Amps -03 Nos 5) MCB TPN 63 Amps -03 Nos6) 4 strip AL Busbar 400Amp (1.3 Amp per Sq.mm, TPN)- 02 Sections7) Changeover 320A 4Pole |
| 2 | Supply, installation, testing and commisioning of Switch Fuse Unit Triple Pole with Neutral Link in SS Enclosure, 415 Vac, 50 Hz with ample Space for Cable Termination capacity upto 150 sq.mm Al. cable with lug.315A Rating |
| 3 | Supply of PVC insulated PVC sheathed cable of 1.1KV grade armoured Underground aluminum conductor cable as reqd confirming to IS –7098 part I with up to date amendments) of the following size4x35 sqmm |
| 4 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 5 | Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 kv grade as required. 4x35 sqmm(32mm) |
| 6 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required .4 way (4+12) double door. |
| 7 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)16 way , Double door |
| 8 | Supplying and fixing following rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 9 | Single pole 6A-32A |
| 10 | Double Pole 40A |
| 11 | Double Pole 63A |
| 12 | Triple Pole & Neutral 63A |
| 13 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 14 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 15 | 2 X 16 sq. mm + 1 X 6 sq. mm earth wire |
| 16 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 17 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 18 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 19 | 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire |
| 20 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 21 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 22 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 23 | 12 Module (200mmX150mm) |
| 24 | 6 Module (200mmX75mm) |
| 25 | 3 Module (100mmX75mm) |
| 26 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 27 | 5/6 A switch |
| 28 | 15/16 A switch |
| 29 | 3 pin 5/6 A socket outlet |
| 30 | 6 pin 15/16 A socket outlet |
| 31 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 32 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 33 | LED Panel light 2x2 ft. 36 Watt (System lumen efficacy ≥120 <135 lm/Watt) Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 5700°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 34 | LED Down lighter 18 watt (SMD Type) (System lumen efficacy ≥120<135lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 5700°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . |
| 35 | LED Batten light 18-22 Watt (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 5700°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 36 | LED Suspended Linear Light 30 Watt, 1200 mm length.Supplying, installation, testing and commissioning of suspended type linear LED luminaire, 30 watt, 1200 mm length of extruded aluminium housing with opal / UGR compliant diffuser and construction suitable for indoor commercial use, complete with replaceable electronic LED driver having driver efficiency >85%, suitable for operation on AC 140–270 Volt, 50/60 Hz, complete with suspension kit, connectors and accessories, as required. The luminaire shall be suitable for operation in ambient temperature range of –5°C to 40°C, provided with internal surge protection of minimum 2.5 kV, short-circuit and open-circuit protection, THD <10%, power factor ≥0.95, IP20 protection, CRI ≥80, and shall be flicker-free (flicker <5%). The fixture shall have a rated life (LED, driver and electrical circuitry) of minimum 50,000 burning hours with 70% of initial lumen maintained till end of life. The luminaire shall have correlated colour temperature (CCT) 5700K , as per ANSI binning, with SDCM <3. Maximum power consumption shall not exceed the specified rating. The fixture shall conform to relevant BIS standards. Manufacturer’s word mark / name shall be engraved, embossed or screen-printed on the housing. The item shall include external connections using 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable, complete with earthing, testing and commissioning, complete in all respects. LM-79 and LM-80 test reports and all testing required for LED luminaires as per BIS standards shall be submitted. Shape, size and CCT shall be as approved by the Engineer-in-Charge. Thermal management: The luminaire shall have adequate aluminium housing / heat sink such that LED junction temperature shall not exceed 90°C. OEM Warranty: Minimum 5 years. |
| 37 | Supply of 1200 mm sweep ceiling fan suitable for 230 V ±10%, 50 Hz single-phase AC supply, complete with energy-efficient motor (as per BEE norms), aerodynamically balanced aluminium blades, double ball bearing assembly for smooth and silent operation, minimum air delivery of 210 CMM, and rated speed of about 300–320 RPM. The fan shall be provided with powder-coated finish, rust-resistant body, thermal overload protection, and shall conform to relevant IS standards (IS: 374). The item includes supply of down-rod, shackle assembly, canopy, terminal block, and all standard accessories, complete in all respects as approved by the Engineer-in-Charge. |
| 38 | Supply of 900 mm sweep ceiling fan suitable for 230 V ±10%, 50 Hz single-phase AC supply, complete with energy-efficient motor (as per prevailing BEE norms), aerodynamically balanced aluminium blades, and double ball bearing assembly for smooth and silent operation, having minimum air delivery of about 120–140 CMM and rated speed of approximately 380–420 RPM. The fan shall be provided with powder-coated finish, rust-resistant body, and thermal overload protection, and shall conform to relevant IS standards (IS: 374). The item includes supply of down-rod, shackle assembly, canopy, terminal block, and all standard accessories, complete in all respects, as approved by the Engineer-in-Charge. |
| 39 | Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable etc. as required. |
| 40 | Supply of 450 mm sweep exhaust fan suitable for operation on 230 V ±10%, 50 Hz single-phase AC supply, fitted with heavy-duty copper-wound motor, double ball bearing for smooth and noiseless performance, and corrosion-resistant aluminium blades. The fan shall have a minimum air delivery of about 7,000–8,000 CMH with a speed of approximately 1,300–1,400 RPM. The exhaust fan shall be provided with powder-coated or epoxy-coated body, thermal overload protection, and shall conform to relevant IS standards (IS: 2312). Complete in all respects, including mounting frame and standard accessories, as approved by the Engineer-in-Charge. |
| 41 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 42 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 43 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 44 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 45 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. |
| 46 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 47 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 48 | Supply, fabrication, installation, testing and commissioning of wall-suspended ACP Acrylic LED Sign Board of approved size and design, comprising 3 mm thick exterior-grade aluminium composite panel (ACP) as base panel. The matter/text shall be made of 3 mm thick acrylic sheet, with raised acrylic letters projecting 2.25 inches from the ACP surface, suitably supported using 3 mm / 5 mm PVC foam board (Sunboard) for depth and rigidity. Illumination shall be provided using LED modules of minimum 1.5 W, complete with compatible LED power supply, internal wiring using 2.5 sqmm copper conductor, proper insulation and earthing. The board shall be suspended on wall using suitable heavy-duty SS/MS hanging brackets, anchor fasteners, spacers and supports, ensuring proper load distribution, alignment and clear air gap from the wall surface. The item includes all necessary fixing accessories, finishing, testing, and making good the surface after installation, complete in all respects as directed by the Engineer-in-Charge. |
| 49 | Credit for dismantelled/damaged items:- |
| 50 | Aluminium Scrap ( i.e., Cables, wires etc)(L.S.) |
| 51 | Iron Scrap (dismantled iron conduits, panal etc.)(L.S.) Please Enable Macros to View BoQ information |