| Sl. No. | Item Description |
| 1 | SCHEDULE A PART I (BUILDING WORKS) |
| 2 | Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ Part I . |
| 3 | SCHEDULE A PART II (INTERNAL WATER SUPPLY) |
| 4 | Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Sch ‘A’ Part II. |
| 5 | SCHEDULE A PART III (INTERNAL ELECTRIFICATIONS) |
| 6 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONS as listed in Sch ‘A’ Part III. |
| 7 | SCHEDULE A PART IV (EXTERNAL WATER SUPPLY) |
| 8 | Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY as listed in Sch ‘A’ Part IV . |
| 9 | SCHEDULE A PART V (EXTERNAL ELECTRIFICATION) |
| 10 | Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION as listed in Sch ‘A’ Part V |
| 11 | SCHEDULE A PART VI (SEWAGE DISPOSAL) |
| 12 | Lump sum price worked out by the contractor for BSEWAGE DISPOSAL as listed in Sch ‘A’ Part VI |
| 13 | SCHEDULE A PART VII (AREA DRAINAGE) |
| 14 | Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Sch ‘A’ Part VII |
| 15 | SCHEDULE A PART- VIII (ROAD, PATH, CULVERT AND HARDSTANDING) |
| 16 | Lump sum price worked out by the contractor for ROAD/PATH AND CULVERT as listed in Sch ‘A’ Part VIII |
| 17 | SCHEDULE A PART- IX (FENCING AND GATE) |
| 18 | Lump sum price worked out by the contractor for COMPOUND WALL, FENCING AND GATE as listed in Sch ‘A’ Part IX |
| 19 | SCHEDULE A PART- X (AIR CONDITIONING AND REFRIGERATION WORKS) |
| 20 | Lump sum price worked out by the contractor for AIR CONDITIONING AND REFRIGERATION WORKS as listed in Sch ‘A’ Part X |
| 21 | SCHEDULE A PART- XI (EARTHWORK AND SITE CLEARANCE) |
| 22 | Lump sum price worked out by the contractor forEARTHWORK AND SITE CLEARANCE as listed in Sch ‘A’ Part XI |
| 23 | SCH \\"A\\" PART XII(MISCELLENEOUS B/R AND E/M ITEMS) |
| 24 | Supply of FRP based earthing display board with support stand, width 254 mm, Length 380 mm and Hgeight 610 mm |
| 25 | M&L for construction of block masonry valve pit chamber of size 600x600x600mm (internal dimensions) with 50 mm thick foundation using PCC 1:3:6 (type D-2), block masonry wall built in CM 1:4, 15mm thick internal plaster including top of floor in CM 1:4, finished even and smooth without using extra cement, and 20mm thick external plaster in CM (1:4) and 3.15mm thick MS sheet cover including 40x40x6mm MS angle frame fixed in PCC 1:2:4 type B-1 coping with 25x4mm flat iron hinges, hold fasts, handles, locking arrangements, applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer to all steel surface including excavation and earth work in any type of soil complete, as specified and as directed. |
| 26 | Supply, installation, testing & commissioning of 11 KV, 400 A, 3 pole, 50 HZ , 26 KA for 3 sec rupturing capacity, floor mounted, compartmentalised, indoor type, free standing [grouted in PCC 1:2:4 type B1(Using 20 mm graded stone aggregate)], duly labelled with vinyl stickers, modular construction, 6 way HT Panel fabricated in minimum 14 SWG CRCA sheet, supported with suitable size base channel not less than 75x75x5 mm, painted in Siemens Grey shade RAL 703, compartmentalised, dust and vermin proof, minimum IP 42 protection with bus /PT/relay compartment having IP 52 , doors and covers with non-ageing gasket, doors with concealed hinges with handle and locking facility, electrolytic grade copper bus bar of rectangular cross section of adequate size for 600 A , cable glands, cable bottom entry for incoming and outgoing cable, danger plate, thermostatically controlled strip heater with provision of double earthing terminals, lifting studs, louvers for proper ventilation covered with fine GI screen comprising of following : -(For Incomer and Outgoing at proposed Sub-Station)(a) 11 KV, 3 pole, 50 HZ 400 A draw out type VCB -07 Nos ( 02 Nos for incoming, 03 Nos for outgoing with 02 Nos for bus coupler) confirming to IEC 62271-100 and 62271-200 ,E2 class, rupturing capacity 25 KA for 03 seconds, manual and motorised spring charging mechanism suitable to operated by 240 volts AC single phase/110 V DC supply. 24 volt DC universal motor 200 watts and having charging time less than 10 seconds all as per Original Equipment Manufacturer (OEM) design, with overload, earth fault and short circuit protection, interrupter life minimum 30000 times at rated current and minimum 100 times at short circuit current (b) Dual core dual ratio Current Transformer (CT) chamber, class E insulation, comprising of 3 Nos, single phase resin cast / ring core CTs of 200-100 / 5+5, burden not less than 15 VA and accuracy class 0.5, for metering, having class SP10 for protection as per IS:2705 for each circuit breaker - 07 Sets for 07 VCBs. |
| 27 | (c) 2 No. Potential Transformer (PT) for incomer, 3 phase, dry type (resin cast) fixed type 11 KV / 110 Volts, class 'E' insulation, Burden 100 VA, Accuracy class 0.5 with HT HRC fuses & TPN MCB for primary and secondary respectively complete all as specified and as directed as per IS: 3156 - 02 Set (01 each for incoming) (d) SCADA compatible self-powered , programmable type IDMT numerical relays having overload, earth fault and short circuit tripping facility, facility to record fault event with fault current and nature of fault , adjustable over current & earth fault and fault time setting (separate for earth fault and overcurrent), suitable DC auxiliary supply, housed on horizontal draw out type case, flush pattern with accessories duly connected with trip and alarm system -07 Nos total for complete protection of HT ,11 KV,3 Phase feeder MODBUS communication on RS 485 communication port - 07 No. including 1 No voltage monitoring relay for under voltage / over voltage protection -07 Nos (e) PLC shall also be wired to all VCB's to monitor open/close status. The unit shall be supported with power pack of 110 Volt battery with battery charger (110-volt DC output) for supply backup for PLC (Minimum power back up for 10 hours) & motor operation. The unit shall include all necessary standard fitting required at site. (f) One set of mechanical indicator for ON / OFF indication for all VCB.(g) LED type indication lamps for CB ON, CB Close, CB trip, spring charged , Trip circuit healthy with push button and one set of capacitive voltage indication for R-Y-B -01 set for each VCB(h) One set of battery and battery charger to provide suitable back up as per OEM's instruction(i) Digital PT operated Voltmeter with inbuilt selector switch suitable for 11 KV , 3 phase, 50 HZ CBs with accuracy class 0.5 -07 sets |
| 28 | (j) Digital CT operated Ammeter with inbuilt selector switch suitable for 11 KV , 3 phase, 50 HZ, 200-100 / 5+5 CTs with accuracy class 0.5 -06 sets (k) Power pack suitable capacity with maintenance free battery and charger to provide required aux supply to VCBs as per OEM recommendation (l) Any other standard fittings / accessories required for smooth functioning of HT panel Notes : - 1. HT panel shall be installed and commissioned by OEM at site including relay calibration up to entire satisfaction and test report to be submitted duly signed by user's rep and Engineer-in-Charge. 2. Bus coupler and incoming VCB will be provided with electrical and mechanical interlocking. 3. The job includes all control wiring with suitable size of copper conductor (mininimum 2.5 Sqmm ), necessary electrical connections and civil works.4.Both the incoming VCB shall consist of Manually spring charged breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 4 NO + 4 NC and equipped with following switchgears and accessories as required and instruction of Engineer Incharge. Microprocessor based numerical relay (IDMT relay) with 2 levels of over current and earth fault protection, 3 O/C and 2 E/F element with LED’s for fault indication and at least 15 trip records for over current & 15 for earth fault. Trip records must be with date & time stamping. multifuction meter with basic parameters like frequency, KW, KVA, KVAR, Power Factor, total harmonic distortion, Phase sequence indicator, Fault indicator etc. shall be suitable for EMS function with RS 485 port for communication. |
| 29 | Supply, installation, testing and commissioning of distribution transformer, capacity 2500 KVA step down, indoor type floor mounting, double copper wound core type 3 Phase 50 Hz AC, oil immersed with IS: 335 ISI marked filtered & dehydrated Transformer oil with 'ONAN' type cooling with external cooling tubes / radiators having no load voltage ratio 11/.433KV (corresponding to principal tapping) delta connected on primary side (HV incoming) and star connected on secondary side (secondary out going) in accordance with vector group symbol (DYN-11) conforming to IS : 1180 (Part I) : 2014 and IS 2026 (part I -4) and having On load tap changer in the steps of 1.25% on HV side to take care of voltage from (+)5% to (-) 15% to give output on 433 volt secondary side and including initial oil filling to appropriate level, control cable, and following standard fittings complete all as specified and as directed including the followings:-(i) Oil conservator with oil filling hole cap and drain plug.(ii) 01 No of prismatic oil level gauge mounted on conservator wall with first fill of charge upto maximum level.(iii) Silica gel dehydrating breather with oil seal and with first fill of charge.(iv) Pressure release valve with automatic resetting arrangement after release of pressure- 01 Set(v) Adequate No of thermometer pocket including one thermometer.(vi) Top oil filter valve. (vii) Bottom oil filter cum drain valve.(viii) Rating diagram and terminal marking plate.(ix) Earthing terminal - 02 Nos. (x) Lifting lugs - 01 Set.(x) Jacking pads - 01 Set. |
| 30 | (xi) Under carriage with 4 Nos of plain rollers.(xii) Air release plug on main transformer tank.(xiii) Adequate Nos of cooling radiators.(xiv) 100 mm dial type oil temperature indicator with maximumread pointer and resetting device.(xv) 100mm dial type winding temperature indicator with maximumread pointer resetting device(xvi) Air insulated cables box on HV and LV side. (xvii) Buchholz Relay (having Contacts for Alarm & Trip). (xviii) OTI (having Contacts for Alarm & Trip). (xix) WTI (having Contacts for Alarm & Trip). (xx) Marshalling Box (having TTB Only)NOTE :- : (i) Routine test shall be carried out as per IS 1180. (ii) Pre-dispatch inspection at OEM factory premises shall be carried out by Rep of Accepting officer.(iii) Prior to manufacture the contractor shall get the general arrangement, drawing and design details of the transformer approved from GE.(iv) After installation of Transformer at site , the pre-commissioning test shall be carried out by SEI./EI.(v) After installation of transformer on work site final checks for nut, bolts, screws must be done to ensure safe transportation and proper operation shall be carried out in the presence of Engineer-in- Charge. |
| 31 | Supply, installing, commissioning & testing of Servo controlled voltage stabilizer (Confirming to as per BIS 9815 : Part I : 1994), Three phase AC system, 50 Hz of capacity 2500 KVA as per requirements naturally oil cooled, indoor, unbalance type load, copper wound, with microprocessor based control card, digital type, relay free smooth and silent operation with 1st filling of new insulating oil as per BIS standard packed in sealed containers, including necessary incoming and outgoing connection, loses as per IS-9815, IS 14697 (including all amendments/updates) complete all as specified and having following specifications : (a) Input voltage 360 V to 480V (b) Output voltage stabilized at any designed/desired voltage 415V ± 1% (c) Rated frequency 50Hz (d) No distortion in wave form (pure sine wave)(e) Response time not to exceed 10 milli seconds (f) Sensitivity (±) 1% (g) Rate of correction 6 volts /second minimum (h) Efficiency more than 98% (i) Type of load : Three phase, unbalanced type(j) Multifunction meter 3 phase 415 volts showing Voltage, Amps & Hz.(k) Oil quantity as recommended by manufacturer complete with oil level indicator showing minimum and maximum level of oil and temperature gauge (l) Charging motor of suitable capacity (m) Termination : Input & output termination as per IS : 3347.(n) Operation : Auto or Manual (o) Metering : Digital AC voltmeter with selector switch for input & Output voltage. |
| 32 | PROTECTION(i) Overload Cut-Off and short circuit Protection(ii) High/Low voltage cut off (iii) Bypass arrangement in case of emergency(iv) Single phase Prevention (v) Spike and surge protection(vi) Earth Fault protection.INDICATOR DIGITAL :-(i) Power indicator (ii) Voltage level indicator (iii) Frequency Meter(iv) Power Factor indicator (v) Ammeter, Temperature Meter, Digital Ammeter& Digital voltmeter (vi) Phase sequence indicator (vii) Oil level indicator |
| 33 | Supplying, installation, testing and commissioning of following capacity prefabricated Sandwich Type Copper Bus Trunking with minimum Class F insulation on 3 phase 4 wire 433 volts, 50Hz A.C. supply with metal clad enclosure made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with necessary joints, elbow joints & expansion joints and bends, provision of tapping, adopter box and copper flexible for joints, continuous earthing with 2 Nos earth strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The rate should be quoted including MS Support structure for support of bus duct. it shall be tested as per IEC 61439 part 1 & 6, Zone 5, as per IS 1893 (Part 1) - 2002 and IEEE 693 - 2005 Tested with Vertical+Horizontal busduct and Plug-in Box assembly. Purity of copper conductor should not be less than 99.6%.Size : bus trunking system with copper bus bar 4000 Amps, 50 KA breaking capacity,IP 54 protection (Transformerx2 to Volatge stablizer and Voltage stablizer to Feeder Panel 1) |
| 34 | Supply,installation,testing and commissioning 3 phase and neutral , 415 volts indoor type, CPRI approved, factory made free standing, floor mounting, dust and vermin proof, cubical type LT Feeder Pillar of suitable size to accomodate the below mentioned equipments along with adequate space for working fabricated from 2.00 mm thick CRCA sheet with angle iron frame of 50 x 50 x 6 mm , double door , front and back openable type, double door system, hinged opening , rubber lining,locking arrangement,with anticorrosive coating and finally epoxy polyester powder coating with pure polyster Siemens grey structural RAL-7032 shade , protection class IP-54 fully compartmentalize design with 4 nos of bus bar made of copper of ETP grade suitable for 6000 Amps ( Size of copper strip should not be less than 250 x 20 mm for each phase and neutral) pre-wired with suitable size of copper strip/ copper wire with colour code for internal connection between ACBs and bus bar, including suitable aluminium earth strips conforming to IS with danger notice plate , necessary cable glands, cable connection with proper lugs ,PCC foundation and pedestal for fixing piller feeder box with PCC 1:5:10 , 15 cm thick in foundation , brick (Fly ash) / PCC block work in CM 1:6 , rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting bolts etc for panel. The plateform shall be of 450 mm height above ground level all as specified with supply and fixing the following. (For Changeover)(i) ACB 4000 Amp 4P ICW for 3 sec 65 KA (Manual draw out type micro processor release along with position indication, spring charge indication switch, trip indication switch, door flange, safety shutter and with fault recording+ LCD display)-03 Nos Two sets of ACB as incoming, meanwhile only one will operate at a time with integrated interlocking system. Third one will perform as outgoing (switching between incoming ACB's should be maximum one to two cycle or as per OEM as recommended by IS.(ii) Panel mounted digital multifinction meter in 96x96 mm flush mounted case SP accuracy class 0.5, voltage measuring range 0-500V AC, CT secondary site suitable 1A/5A, programmable CT/PT to measure V,A,F,PF,KW,KVA,KWH/KVh - 02 sets (iii) Indicator lamp RYB (set of three) - 02 sets |
| 35 | Supply,installation,testing and commissioning 3 phase and neutral , 415 volts indoor type , CPRI approved, factory made free standing , floor mounting ,dust and vermin proof, cubical type LT Feeder Pillar of suitable size to accomodate the below mentioned equipments along with adequate space for working fabricated from 2.00 mm thick CRCA sheet with angle iron frame of 50 x 50 x 6 mm , double door , front and back openable type, double door system, hinged opening , rubber lining,locking arrangement,with anticorrosive coating and finally epoxy polyester powder coating with pure polyster Siemens grey structural RAL-7032 shade , protection class IP-54 fully compartmentalize design with 4 nos of bus bar made of copper of ETP grade suitable for 7000 Amps ( Size of copper strip should not be less than 150 x 10 mm for each phase and neutral) pre-wired with suitable size of copper strip/ copper wire with colour code for connecting out going MCCB/ MCB`s, including suitable aluminium earth strips conforming to IS with danger notice plate , necessary cable glands, cable connection with proper lugs ,PCC foundation and pedestal for fixing piller feeder box with PCC 1:5:10 , 15 cm thick in foundation , brick (Fly ash) / PCC block work in CM 1:6 , rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting bolts etc for panel. The plateform shall be of 450 mm height above ground level all as specified with supply and fixing the following. LT Panel IP 42, type tested from ASTA/CPRI/ERDA as per IEC 61439 Part 1 & 2, internal arc compliance of 85kA-0.5s as per IEC 61641, IK10 as specified in IEC 62262, ICC ES AC -156, 3.2g Compliance. The LV Panel shall be manufactured in accordance with switchgear OEM design guidelines, ensuring full compliance with IEC 61439 standards. The type test certification shall be done by OEM and franchisee shall carry out assembly as per type tested design. To ensure compatibility, both the panel design and the switchgear components (ACB with phase sequence protection (ANSI 47)/MCCB/Control gear etc) should be from same OEM. The type designation and certification label on the panel shall prominently feature the OEM's name. Make of Panel : Siemens ( Sivacon S8 ) , Schneider ( OKEN ) , Lauritz Knudsen ( ENERSYS ) (Feeder Panel 1) |
| 36 | (b) Incoming : (i) ACB with phase sequence protection (ANSI 47) 5000 Amp 4P ICW for 1 sec 65kA EDO ACB with phase sequence protection (ANSI 47) with microprocessor release with Password Protection in Release having LSING protection with RS485, Pollution degree 4. It should have Combined Test Sequence Certification from CPRI/ERDA/ASTA. It should have arc chute interlocking, Mechanical & Electrical anti-pumping. The release shall have metering & oLED display of Current, % Loading, Imin, Imax, Current Bargraph, last 20 trip data, Phase-1, 2 & 3-Total, Fundamental, THD, oscillograph of fault current. Seperate LED for Pwr, O/L, S/C, INST, E/F, NTRL, ALRM, TRIP-02 No (one working one stand by)(ii) Panel mounted digital multifinction meter in 96x96 mm flush mounted case multifuction meter with basic parameters like frequency, V, In, Ay, Ar, Ab, KW, KVA, KVAR, Power Factor, total harmonic distortion etc. shall be suitable for EMS function with RS 485 port for communication-06 sets(iii) Indicator lamp RYB (set of three)-06 set(iv) CT 5000/5 A 15 VA Cl 1 (set of 3 Pcs)-02 set (v) CT 2000/5 A 15 VA Cl1 (set of 3 Pcs)-01 set, (vi) CT 630/5 A 15 VA Cl1 (set of 3 Pcs)-10 set (vii) CT 400/5 A 15 VA Cl1 (set of 3 Pcs)-02 set, (viii) CT 250/5 A 15 VA Cl1 (set of 3 Pcs)-02 set,(ix) MCB 6A, SP, 10 KA for protection (set of 3 Pcs)-05 set |
| 37 | (c) Outgoing : (i) ACB with phase sequence protection (ANSI 47) 630 Amp 4P , Icw for 1 sec 65kA EDO ACB with phase sequence protection (ANSI 47) with microprocessor release with Password Protection in Release having LSING protection with RS485, Pollution degree 4. It should have Combined Test Sequence Certification from CPRI/ERDA/ASTA. It should have arc chute interlocking, Mechanical & Electrical anti-pumping. The release shall have metering & oLED display of Current, % Loading, Imin, Imax, Current Bargraph, last 20 trip data, Phase-1, 2 & 3-Total, Fundamental, THD, oscillograph of fault current. Seperate LED for Pwr, O/L, S/C, INST, E/F, NTRL, ALRM, TRIP-10 Nos (8 W+ 2S )(ii) ACB with phase sequence protection (ANSI 47) 2000 Amp 4P ICW for 1 sec 65kA EDO ACB with phase sequence protection (ANSI 47) with microprocessor release with Password Protection in Release having LSING protection with RS485, Pollution degree 4. It should have Combined Test Sequence Certification from CPRI/ERDA/ASTA. It should have arc chute interlocking, Mechanical & Electrical anti-pumping. The release shall have metering & oLED display of Current, % Loading, Imin, Imax, Current Bargraph, last 20 trip data, Phase-1, 2 & 3-Total, Fundamental, THD, oscillograph of fault current. Seperate LED for Pwr, O/L, S/C, INST, E/F, NTRL, ALRM, TRIP. -01 Nos (for APFC panel) (iii) MCCB 4 pole ,415 volts , AC supply , 250 Amps, 36 KA breaking capacity Ics=Icu, Ics=100% of Icu=36 kA,having LSING Protection, double break Contact Locking Dead-Centre (D/C) mechanism, adjustable overload setting of 158-630A, Variable S/C 1.5-8 x In. MCCB shall have true rms sensing, no Load-line bias, double insulation, inbuilt ambient temperature compensation. Seperate LED indication for Pwr, O/L, S/C, INST, E/F -02 Nos (1W+1S ) (for LT panel ) |
| 38 | Supply,installation,testing and commissioning 3 phase and neutral , 415 volts indoor type , CPRI approved, factory made free standing , floor mounting ,dust and vermin proof, cubical type LT Feeder Pillar of suitable size to accomodate the below mentioned equipments along with adequate space for working fabricated from 2.00 mm thick CRCA sheet with angle iron frame of 50 x 50 x 6 mm , double door , front and back openable type, double door system, hinged opening , rubber lining,locking arrangement,with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade , protection class IP-54 fully compartmentalize design with 4 nos of bus bar made of copper of ETP grade suitable for 500 Amps (copper strip ) pre-wired with suitable size of copper strip/ copper wire with colour code for connecting out going MCCB/ MCB`s, including suitable aluminium earth strips conforming to IS with danger notice plate , necessary cable glands, cable connection with proper lugs ,PCC foundation and pedestal for fixing piller feeder box with PCC 1:5:10 , 15 cm thick in foundation , brick (Fly ash) / PCC block work in CM 1:6 , rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting bolts etc for panel. The plateform shall be of 450 mm height above ground level all as specified with supply and fixing the following. LT Panel IP 42, type tested from ASTA/CPRI/ERDA as per IEC 61439 Part 1 & 2, internal arc compliance of 85kA-0.5s as per IEC 61641, IK10 as specified in IEC 62262, ICC ES AC -156, 3.2g Compliance. The LV Panel shall be manufactured in accordance with switchgear OEM design guidelines, ensuring full compliance with IEC 61439 standards. The type test certification shall be done by OEM and franchisee shall carry out assembly as per type tested design. To ensure compatibility, both the panel design and the switchgear components (ACB with phase sequence protection (ANSI 47)/MCCB/Control gear etc) should be from same OEM. The type designation and certification label on the panel shall prominently feature the OEM's name. Make of Panel : Siemens ( Sivacon S8 ) , Schneider ( OKEN ) , Lauritz Knudsen ( ENERSYS ) (Feeder Panel 2) |
| 39 | (b) Incoming : MCCB 400 Amp 4P 36 KA micro processor based release -01 No(ii) Panel mounted digital multifinction meter in 96x96 mm flush mounted case SP accuracy class 0.5, voltage measuring range 50-520V AC, CT secondary site suitable 1A/5A(iii) Indicator lamp RYB (set of three)-02 set(c) Outgoing : (i) MCCB 400 Amp 4P 36 KA micro processor based release -01 No |
| 40 | Supply , Installation , comissioning and testing at various load power factor of APFC panel for 3 phase 415 V 50 HZ system of capacity 800 KVAR with APP super heavy duty , capacitor in 8 Steps and MCCB as incomer complete all as specified and directed. The APFC panel should have capacitor duty contactor with duty AC6B, 3 CT sensing APFC relay as per IS and OEM instruction complete all as specified and directed by Engineer - in- Charge. |
| 41 | Supplying, installing, testing & commissioning out door type cubical panel board outer shell made out of 3.15 mm thick MS sheet and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able by Keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process.( LT Panel 3 (for Adm Building)a) TPN aluminium bus bar 400 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators not less than 1.0 mtr long.b) Incoming MCCB 250 Amps 4 pole 415 Volts AC,Icu=100%Ics, rupturing capacity 36 KA.Confirming to IS/IEC 60947-2 -02 Nosc) Outgoing MCCB 160 Amps 4 pole 415 Volts AC,Icu=100%Ics, Adjustable type thermal release for over current,short circuit & earth fault with display and fault discrimination rupturing capacity 25 KA.Confirming to IS/IEC 60947-2 -02 Nos(d) '-ditto- but MCB TPN 40 Amp 10 KA C Curve - 1 Nos(e) MCB SPN 32 Amps 10 KA C Curve - 03 Nos |
| 42 | M&L for providing twin core PVC insulated sheathed(heavy duty) unarmoured aluminium conductor cable (for phase earth and neutral) of size 2.50 Sqmm for connection drawing through pole or GI brackets of street light fittings with junction box or OH conductor complete all as specified and directed. |
| 43 | S&F for cable route/joint indicator made of Precast RCC slab of size 90 cmx 30 cm x10 cm M 20 grade embeded in ground on the route of cable duly marked with HT cable / HT cable joint . |
| 44 | M&L for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50Mtrs below ground level) connected to GI wire 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm GI tubing medium grade and necessary fitting for protection of GI strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, PCC chamber using PCC(1:3:6) type C-1 using 20mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm C/C both ways with MS handle 8mm dia, plastering 15mm thick CM (1:6) externally up to 150mm below ground level, GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on Electrical plate No.3 of SSR Part-I (2009) and connected to earth test point incl testing and marking Bldg Nos and writing Test Results (in white) on a black painted M.S. Plate (size 300x300x3mm th) duly welded with angle iron of size 40X40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.Note :- (i) GI wire and GI pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing. (ii) Excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) The rates quoted by the contractor are deemed to be included for MS sheet of size 300x300x3mm th, fixed with necessary nuts and bolts on angle iron of size 40X40x5mm, 60cm long and grouted with PCC block of size 200x200x250mm(PCC 1:3:6 using 20mm grade stone aggregate including necessary earth work for marking the result and purpose. |
| 45 | M&L earthing for power transformer complete with copper earth plate electrode 600mm x 600mm x 3.15 mm thick burried directly in ground (Earth pit not less than 3.0 m deep below ground level) with top edge of the plate not less than 2.25m below ground level connected to copper strip 20 x 3 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation in any type of soil(except rock), filling charcoal and salt around the plate in layers , filling the pit with agriculture soil free from stones, to be bring from outside defence land, and to be mixed with and including bentonite - 03 bags of 25 KG each for each pit, construction of PCC earth pit chamber of size 900 x 900 x 450 mm , RCC chamber cover plate, wire mess, funnel, test point, 32 mm dia GI protection pipe light grade and 40 mm GI medium grade peforated pipe for watering etc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed. |
| 46 | Supply only Black/Blue PVC insulating electrical mat of 1 meter x 2 meter x 3 mm suitable for 11 KV as per as IS 15652, |
| 47 | M &L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed. |
| 48 | Supply, installation, testing and comissioning of flame proof horixontal self priming multi stage bare shaft coupled pump AOH -5102 with suction and delivery sizes 50x50 mm, discharge flow rate 20 Cum per hour discharge head 20 mtrs, 2 stage, ideal for diesel, mechanical sealing, open type impeller, made oout of cast iron construction with bronze impeller and stainless steel shaft 10 HP, 1450 RPM 3 phase, 50 Hz, IP 55, floor mounted temp 90 degree with mounting base plate coupling & PCC foundation as per manufacturer design, complete all as specified and directed. |
| 49 | Supply, installation & testing of in line horizontal integral mounting flow meter flanged end SS 304, out put 4 to 20 mA, operating temp 70 degree celcius, mounting in line horizontal, flame proof enclosure, 230 V AC, 9 Character X 2 Line LED Display with 4 digit flow rate, 9 digit total flow for application in diesel flow, flow range 4 to 40 m3/hr, for line size 50 NB (2 inch) complete all as specified & directed |
| 50 | Supply & fix flame proof star delta starter 10 HP including cable of size 25 Sqmm 3 core cable from starter to motor, complete all as specified and directed |
| 51 | Supply and fix Flame proof - weather proof MCCB with weather proof enclosure 63 Amps, 3 pole 415 volts |
| 52 | Supply and fix Foot Valve conforming to IS 4038, 50 mm (2”) dia , complete all as specified & directed |
| 53 | Supply and fix Strainer Y type conforming to IS, size 50 mm (2”) dia complete all as specified & directed |
| 54 | M & L for 5 Amps flame proof socket out let on independent board, complete all as specified and directed. |
| 55 | M & L for flame proof LED light fittins of 1x20/22 watt, complete all as speciifed and directed. |
| 56 | Supply erecting and fixing hot dipped galvanised octagonal poles, 7 mtr long poles, with top A/F 70 mm, bottom A/F 130mm, made out of 3 mm thick Ht sheet along with base plate of size 220x220x12 mm including up to 1500 mm double arm bracket made out of 48 mm dia medium grade GI pipe, M20 in PCD 205 mm, 700 mm long and projected 100 \\"J\\" type EN8 grade 04 nos foundations bolts alongwith template and following accessories :-(a) MCB SP 6 Amps, 230 volts\\"B\\" series 10 KA - 01 No .(b) 4 way DMC connector, bolt type having locking arrangements and water proof control space - 01 NoNOTE : (i) The rate quoted shall also deemed to be inclusive for the cost for provn of 50 mm bore heavy grade PVC pipe from cable trench to centre of pole concrete and bus bar for provision of cable with termination box etc.(ii) The cost of foundation as per OEM including concrete shall be measured and paid seperately. |
| 57 | M & L for diesel compitable NRV sealed both end, size 50 mm (2 \\")dia, complete all as speciifed and directed. |
| 58 | Supply, installation, testing and commissioning outdoor type cubical panel board outer shell made out of 3.15 mm thixk MS sheet and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 factory fabricated with front opneable double door system and cable alloy (Each door hinged eith body at 3 places with body and hinges should be bwelded with body and door) lockable/openable by keys having chromlum plated 19 mm dia fancy lock. 'U' type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire, 415 volt, 50 Hz, tested at the factory approved from CPRI for 1 MVA ruptruiing capacity at 415 volt, factory fabricated having moder fabrication and testing process. (BPI Tank) a) TPN aluminium bus bar 100 Amps insulated with colour coded heat shrinkable sleeve and shall be mounteed on suitable size 'F' class insulators not less than 1.0 mtr long. b) Incoming flame proof, weather proof MCCB 63 Amps, 3 pole, 415 volts compatible. c) Outgoing Flame proof star starter compatible for 10 HP, 3 Phase, 415 volts.- Set of 2 starter d) voltage dcurrent measuement phase indicatore and all other connected accessories. e) voltage, current measurement, phase indicator and all other connected assessories. CA NO. CE(AF)/PRZ/BHT/03 of 2026-27 Sl Page No 39 SCHEDULE ‘A’ PART- I(BUILDING WORK) Srl No Description of items of works Drg No Unit No of units Rate in Rs Amount In Rs |
| 59 | Supply, installation, testing and commissioning outdoor type cubical panel board outer shell made out of 3.15 mm thixk MS sheet and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 factory fabricated with front opneable double door system and cable alloy (Each door hinged eith body at 3 places with body and hinges should be bwelded with body and door) lockable/openable by keys having chromlum plated 19 mm dia fancy lock. 'U' type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire, 415 volt, 50 Hz, tested at the factory approved from CPRI for 1 MVA ruptruiing capacity at 415 volt, factory fabricated having moder fabrication and testing process. (BPI Tank) a) TPN aluminium bus bar 100 Amps insulated with colour coded heat shrinkable sleeve and shall be mounteed on suitable size 'F' class insulators not less than 1.0 mtr long. b) Incoming flame proof, weather proof MCCB 63 Amps, 3 pole, 415 volts compatible. c) Outgoing Flame proof star starter compatible for 10 HP, 3 Phase, 415 volts.- Set of 2 starter d) voltage dcurrent measuement phase indicatore and all other connected accessories. e) voltage, current measurement, phase indicator and all other connected assessories. CA NO. CE(AF)/PRZ/BHT/03 of 2026-27 Sl Page No 39 SCHEDULE ‘A’ PART- I(BUILDING WORK) Srl No Description of items of works Drg No Unit No of units Rate in Rs Amount In Rs |
| 60 | Construction of single storey office accomodation (Adm Building) complete all as specified and all as shown in drawings. |
| 61 | Construction of sub station building single storey complete all as specified and all as shown in drawings. |
| 62 | Construction of guard room single storey, complete all as specified and all as shown in drawings. |
| 63 | Construction of car parking, complete all as specified and all as shown in drawings. |
| 64 | Construction of scooter parking, complete all as specified and all as shown in drawings. |
| 65 | Construction of semi under ground Static water tank of 110 KL capacity, complete all as specified and all as shown in drawings. |
| 66 | Construction of fire point, complete all as specified and directed. |
| 67 | Construction of sentry post, complete all as specified and directed. Total amount of Schedule ‘A’ Part-I carried over to BOQ Rs 21186300.0 Signature of Contractor AAD (Contracts)For Accepting Officer SCHEDULE ‘A’ PART- II(INTERNAL WATER SUPPLY) Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 68 | S & F galvanised steel water tubes 15mm bore medium grade with all fittings, fixed to walls and ceilings or laid in floors complete all as specified and directed. |
| 69 | S & F galvanised steel water tubes 20 mm bore medium grade with all fittings, fixed to walls and ceilings or laid in floors complete all as specified and directed. |
| 70 | S & F galvanised steel water tubes 25 mm bore medium grade with all fittings, fixed to walls and ceilings or laid in floors complete all as specified and directed. |
| 71 | S & F 15 mm bore fancy type chromium plated Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed. |
| 72 | S & F 15 mm bore fancy type, chromium plated Stop valves, cast copper alloy,screwed down, high pressure, with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed. |
| 73 | S & F 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed. |
| 74 | S & F 25 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed. |
| 75 | S & F 15 mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified and directed. |
| 76 | S & F pillar taps 15mm bore , cast copper alloy fancy type with capstan heads, chromium plated, quarter turn, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts screwed for iron pipe or brass ferrule complete all as specified and directed. Total amount of Schedule ‘A’ Part-II carried over to BOQ Rs 63614.18 Signature of Contractor AAD (Contracts)For Accepting Officer SCHEDULE ‘A’ PART- IIIINTERNAL ELECTRIFICATION Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 77 | M&L for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with and including PVC concealed conduit of medium grade with all fittings including Modular metal flush box, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly and including cutting chases in walls / floors for concealed conduit and making good disturbed surfaces area by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and directed for the following:- |
| 78 | (a) One light, ceiling fan, Exhaust fan or Bell point controlled by one switch. |
| 79 | Ditto al as above as per Sl item No.1 above but with 2.5 sqmm copper conductor cable for One 15 Amps socket outlet on independent board. |
| 80 | M&L for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 4 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with and including PVC concealed conduit of medium grade with all fittings including Modular metal flush box, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 4 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly and including cutting chases in walls / floors for concealed conduit and making good disturbed surfaces by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and directed for Power socket 15 Amps on independent board. |
| 81 | Supply and fixing Modular switch flush type single pole one way 5 Amps 240 volts, white finish complete all as specified and directed. |
| 82 | Supply and fixing Modular switch flush type single pole one way 16 Amps 240 volts, white finish complete all as specified and directed. |
| 83 | Supply and fixing Modular bell push flush type 5 Amps single pole 230 Volt white finish complete all as specified and directed. |
| 84 | Supply and fixing Modular socket outlet 2 in 1, 5 pin, 6 Amps flush type white finish complete all as specified and as directed. |
| 85 | Supply and fixing Modular socket outlet 2 in 1, 6 pin, 6/16 Amps flush type white finish complete all as specified and as directed. |
| 86 | Supply and fix ceiling fan 1200 mm sweep,BEE 5 star rated, ceiling fan with brush less direct current (BLDC) motor , class of insulation :B 3 Nos blade, 30 cm long down rod, 2 Nos, canopies, shackle kit, safety rope, copper winding , power factor not less than 0.9, service value (CMM/W0 minimum 6.00 Air delivery minimum 210 CMM 350 RPM ( tolerance as per IS : 374-2019), THD not less than 10 %, elctronic regulator unit for speed control and all remaining accessories including safety pin, nut, bolts and washers, temperature rise = 75 degree C (max), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, earthing etc including necessary connection with ceiling rose with 3 core 1.0 Sqmm PVC insulated round flexible cable and including wiriting MES No all as specified and directed. |
| 87 | Supply and fixing for ceiling rose surface PVC body three terminal. 65x50 mm complete all as specified and directed. |
| 88 | Supply and fixing lamp holder PVC body with back plate complete all as specified and directed. |
| 89 | Supply and fixing Bell Ding Dong, AC 230 V single pole complete all as specified and directed. |
| 90 | Supply and fixing wall/surface mounted type LED light fitting complete with LED lamp of 1x 20/22 watt (4 ft), extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable suitable size. etc complete all as specified and directed. |
| 91 | Supply and fixing full glow fully diffused recessed mounted LED light fitting 2'x2' . 36 Watts with diffused acylic cover of colour temperature 6000 to 6500K, PF>095, CRI>75, and THD<10, 230 V AC 50Hz complete with eloctronic driver and all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable suitable size. etc complete all as specified and directed. |
| 92 | Supply and fix exhaust fan made of sturdy Engineering plastic, Copper wounded complete with louvers shutter, 230 Volts AC, single phase, 50 Hz, 1200 RPM, 250 mm sweep with blades, frame complete all as specified and directed. |
| 93 | Supply & Fixing MCB SP, 6 to 32 Amps ('B' series) having current rating 10 KA complete all as specified and directed. |
| 94 | S &F MCCB, 3 pole. 100 Amps, 50Hz. 415 Volts with rupturing capacity 16 KA with thermal magnetic release and adjustable overload setting having type DPX 160 conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified & directed. |
| 95 | Supply and fixing factory made epoxy powder coated distribution board MCCB TPN 8 way double door 430 volt, IP-43, suitable for 100 Amps MCCB including 200 Amps copper bus bar ,neutral bar complete fixed properly and to connect their incoming/outgoing electric connections by means of suitable size of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB's of cables/wires complete all as specified and directed. |
| 96 | Supply and fixing factory made epoxy powder coated distribution board DB SPN 4 way double door 430 volt, IP-43, suitable for 100 Amps MCCB including 200 Amps copper bus bar ,neutral bar complete fixed properly and to connect their incoming/outgoing electric connections by means of suitable size of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB's of cables/wires complete all as specified and directed. |
| 97 | Supply and fixing LED Blg security Light fitting 35 Watt, 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver , lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 98 | M&L for surface/concealed sub main wiring as required with two single core FRLSH PVC insulated and unsheathed copper stranded conductor of size 6 Sqmm 1100 Volts and one run of FRLSH copper stranded conductor of size 6 Sqmm for continuous earthing drawn in rigid non metallic PVC conduit pipe ISI marked of size not less than 25 mm dia including to connect their incoming/outgoing electric connections by using required sizes of lugs/thimbles as well as flexible conduit of suitable sizes shall also be used at any open surfaces of conductor complete all as specified and directed.Note :- 1. 2single core cable and one run of earth copper conductor will be measured and paid as one unit length. |
| 99 | S & F flame proof switch rotary type with termination box in LM6, 16 A, single pole 250 Volts |
| 100 | M&L for fire proof concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with and including stove enamelled steel concealed conduit of medium grade with all fittings including Modular metal flush box, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly and including cutting chases in walls / floors for concealed conduit and making good disturbed surfaces area by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and directed. Total amount of Schedule ‘A’ Part-III carried over to BOQ Rs 371448.02 Signature of Contractor AAD (Contracts) For Accepting Officer SCHEDULE ‘A’ PART- IVEXTERNAL WATER SUPPLY Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 101 | M&L for Galvanised steel Tubing 50 mm bore, 'Heavy grade', with heavy grade GI fitting, laid in trenches fixed towall/floor complete all as specified and directed by Engineer-in-Charge. |
| 102 | M&L for Galvanised steel Tubing 25 mm bore, 'Heavy grade', with heavy grade GI fitting, laid in trenches fixed towall/floor complete all as specified and directed Engineer-in-Charge. |
| 103 | M & L for 50 mm dia gun metal globe or gate valve with iron head, screwed both ends for iron pipe, complete all as specified and directed Engineer-in-Charge. |
| 104 | M & L for 25 mm dia gun metal globe or gate valve with iron head, screwed both ends for iron pipe, complete all as specified and directed Engineer-in-Charge. |
| 105 | Cutting of existing cast iron pipes and reducing the length up to required level for insertion of new tees, branch connection or any other means etc upto 150 mm dia, complete all as specified and directed Engineer-in-Charge. Total amount of Schedule ‘A’ Part-IV carried over to BOQ Rs 172896.11 Signature of Contractor AAD (Contracts) For Accepting Officer SCHEDULE ‘A’ PART- VEXTERNAL ELECTRIC SUPPLY Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 106 | M&L for Sand cushioning/covering for underground cable protection and consolidated and compacted with clean dry sand complete all as specified and as directed.Note :- Punned thickness will be measured at the time of measurement and payment. |
| 107 | Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type-I, flat as per IS - 5820 of size 250mm x 150mm x 40mm, laid flat , dry , laid perpendicular to the length of under ground cable in trenches for cable protection complete all as specifeid and directed. |
| 108 | Supplying and laying un-reinforced precast concrete cable cover, Class HV, Type-II, flat as per IS - 5820 of size 450mm x 180mm x 40mm, laid flat , dry , laid perpendicular to the length of under ground cable in trenches for cable protection complete all as specifeid and directed. |
| 109 | Supply, install, commissioning and testing step down transformer indoor type, HT 11 KV , 3 Phase 433 Volts, 4 wire, 50 HZ Delta /Star connected, vector group DYN 11 copper wound, ONAN, on load tap changing facility on HT side to vary secondary voltage of + 7.5% in steps of 2.5%, continuous rating of capacity 250 KVA including bushing on HT and cable end box on LT side. The transformer shall be confirming to IS-1180 Part 1 : 2014 and level 3 certified complete with all standard fittings and accessories, gauges, first filling of transformer oil etc complete all as specified and as directed (a) Oil conservator with filling hole and cap drain valve and oil level gauge (b) Silica gel breather with connecting pipe, first fill of dehydrating agent (c) Explosion relief mounted on tank with double diaphragm and equalizer pipe connected to conservator air spoon (Pressure release valve.)(d) Air release plug.(e) Oil temperature indicator (gauge) having range 0⁰ C to 120⁰ C, 100 mm dial type .(f) Thermometer pocket with thermometer dial size 100 mm dia (g) Drain valve with threaded adapter(h) Sampling valve(j) Cover lifting eyes (k) Jacking pads, handling and lifting lugs (l) Rollers type four No. Wheels (m) Rating plate and terminal marking plate (n) cable end box on HT and LT side (o) Hand hole of sufficient size to assess the interior of the tank(p) First filling of transformer oil. Note: Contractor shall make necessary arrangements for factory inspection for Representative of Accepting Officer to witness Routine tests as Per IS:1180. The cost of testing of transformer shall be deemed to be included in the unit rate quoted. |
| 110 | Supply, laying & testing cable 11000 Volts (E) XLPE insulated with Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, XLPE Insulated, Insulation Screening with extruded Semi Conducting Compound in combination with Copper Tape, cores laid up, innersheath of PVC tape, galvanised flat steel strip armoured and overall PVC Sheathed Cable conforming to IS 7098 / (PART-II) 1985 with latest amendments of size 3 core 185 sq mm complete all as specidied and as directed. (Existing MRS to proposed HPR 2 pole structure, 2 pole structure to proposed HPR VCB and VCB to proposed HPR Transformer ). |
| 111 | Supply, Laying, connecting and testing in replacement XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty 1100 volts grade laid in trenches, floors, ducts passing through pipe for road crossing etc complete all as directed and all as specified and directed including taking out of old unserviceable cable.(excavation, earth work, brick protection sand cushioning and GI pipe etc shall be measured & paid for separately) of following size |
| 112 | Cross sectional area 300 Sqmm 3 ½ core (Feeder 1& 2 to LT PH) |
| 113 | Cross sectional area 240 Sqmm 3 ½ core (Main feeder Panel to LT Panel) |
| 114 | Cross sectional area 95 Sqmm 3 ½ core. |
| 115 | Cross sectional area 10 Sqmm 4 core (for Perimeter light) |
| 116 | Cross sectional area 16 Sqmm 2 core (DSC Post BPI and Power house ) |
| 117 | S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 4 core, complete all as specified and directed |
| 118 | Supply and install steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP - 55 (11 metres long) including applying two coats of black bituminous paint internally and externally upto planting depth and applying two coats of aluminium paint over a coat of red oxide primer, externally from top of coping complete all as specified and as directed.(Note :- Excavation, PCC foundation and coping shall be measured and paid separately.) |
| 119 | Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, including all necessary fittings as per OEM required to be fixed on pole with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. complete all as specified and as directed. |
| 120 | M & L for switch air break gang operated triple pole out door type unit on HT 11 KV 50 cycle AC suitable for current rating upto 400 Amps mechanically operated mounted on insulators (12 insulators) with Drop out fuse unit frame with operating mechanism worked from ground level with earth switch and including locking arrangement complete all as specified and directed. ( 2 at HPR Sub Stn incoming) |
| 121 | Supply and fix cable jointing kit for 11 KV grade cable for outdoor terminal heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 185 sq mm. |
| 122 | Supply and fix cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 120 Sqmm to 185 sqmm, Indoor/Outdoor type |
| 123 | M & L for Aluminium conductor steel reinforced of all sizes complete. |
| 124 | M&L Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size andinclusive of one primer coat, one under coat and one finishing coat ofpaintc complete all as indicated or directed |
| 125 | S& F Light grade GI pipe 80 mm dia, laid in trenches or in wall, complete all as specified ad directed |
| 126 | S & F Lightning arresters expulsion type complete with all fittings, transmission class 11 KV, discharge capacity 65 kilo amp complete all as specified and directed Total amount of Schedule ‘A’ Part-V carried over to BOQ Rs 9386412.89 Signature of Contractor AAD (Contracts) For Accepting Officer SCHEDULE ‘A’ PART- VISEWAGE DISPOSAL Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 127 | M&L Cement Concrete (1:4:8) type D2 (using 40 mm graded aggregate) in foundation filling and mass concreting. |
| 128 | M&L for old size brick work with sub class \\"A\\" bricks straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed |
| 129 | M&L for Providing ,cement concrete type B1, (1:2:4) using 20 mm graded aggregate, in lintel upto 1.5m clear span ,cills,steps, seismic and other similar bands,plinth courses string courses parapets and railing upto 60 cm height, coping and similar. |
| 130 | M&L for rendering 15 mm thick on brickwork or concrete surfaces in cement mortar (1:3) finished even and smooth with using extra cement |
| 131 | M&L for Cement Concrete (1:2:4), type B2 (using 40mm graded aggretate) for benching in surface channel and drains/manholes. |
| 132 | M&L for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. |
| 133 | M&L for reinforced concrete pipes of 150 mm bore, class NP2, laid and jointed complete with collars etc. |
| 134 | M&L for cement Concrete 1:3:6 Type C-2 bed to drain pipes including packing under & haunching against the sides of pipes after they are laid & tested in 150 mm dia pipe |
| 135 | M&L for Pre-cast cement concrete of type B1, 1:2:4 (using 20 mm graded aggr), but in landing, cover slabs (for manholes etc.), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar 1:4 complete. |
| 136 | M&L Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire ( annealed) not less than 0.90 mm dia. Or securing with. Total amount of Schedule ‘A’ Part-VI carried over to BOQ Rs 83238.39 Signature of Contractor AAD (Contracts) For Accepting Officer SCHEDULE ‘A’ PART- VIIAREA DRAINAGE Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 137 | M&L for PCC 1:3:6 type -C2 using 40 mm graded stone aggregate as in foundation filling / mass concrete, complete all as specified and directed by Engineer - in- Charge. |
| 138 | M&L for brick work with fly ash bricks(Old size) straight or curved on plan exceeding 6 M mean radius, using old size bricks built in CM 1:4 complete all as specified and directed by Engineer - in- Charge. |
| 139 | M&L PCC type C1,1:3:6 (20 mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed by Engineer - in- Charge. |
| 140 | M & L for 15 mm thick cement plaster on fair faces of brick work or concrete surfaces in CM 1:4 and finished even and smooth with using extra cement, complete all as specified and directed by Engineer - in- Charge. |
| 141 | M & L for cement concrete 1:2:4 type B-0, using 12.50 mm graded stone aggregate in surface channel, and drain, complete all as specified and directed by Engineer - in- Charge. |
| 142 | M&L for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed by Engineer - in- Charge. |
| 143 | Add or deduct from item No 6 for each 25mm girth or part thereof over or under 30cm -ditto- and directed by Engineer - in- Charge. Total amount of Schedule ‘A’ Part-VII carried over to BOQ Rs 4062524.02 Signature of Contractor AAD (Contracts) For Accepting Officer SCHEDULE ‘A’ PART- VIIIROAD/ PATH/ CULVERT/ HARD STANDING Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 144 | Rolling and consolidating formation surfaces in cutting with power 8 to 10 tone including filling in hollow and depression which occurs durring rolling complete. |
| 145 | Supply, laying and compacting 150mm thick (compacted thick )Granular sub base course (GSB) grading as per Grade II as specified Table 400- 1 of MoRTH specifications for Road and Bridge work, 2013, in a single layer over compacted subgrade with natural sand crushed gravel, crushed stone, crushed slag, or combination thereof as per grading required. The material are mechanically mixed spread and levelling on subgrade by using motor grader of adequate capacity, and rolling with vibratory roller of capacity 80-100 KN static weight for achieving required compaction densityof atleast 98% of maximum dry density.Consolidating to required gradient and camber all as specified and directedwith finished surface tolerance as per Table 900-1 of MoRTH Soecifications for road and bridge work , 2013 |
| 146 | Supply, laying and compacting 150 mm thick (laid in two layers of Compacted thickness 75 mm each ) wet mix macadam (WMM) grading as per table 400-13 of MoRTH specification for road and Bridge work , 2013 manufactured in WMM plant, material comprising of clean crushed graded aggregate and granular material premixed with water to a dense mass spreading with sensor paver and and rolling with vibrotry roller capacity 80-100 KN static weight and consolidating to required gradient and camber complete all as specified and directed. The finished surface tolerance to be as per Table 900-1 of MoRTH Specifications for road and bridge work , 2013 |
| 147 | M&L for preparation of unsurfaced WMM Surface by brushing with wire brushes for removing caked mud etc. sweeping with broom and finally fanning the surface with air compressor to remove all the dirt and dust etc. and applying a evenly priming/tack coat with bitumenous primer (Paving Bitumen VG-10 ) @ 10 Kg per Ten Sqm of Road Surface Complete all as specified and directed. |
| 148 | M&L for premix Bitumineous macadam laid/ rolled and compacted to required gradient camber (Consolidated thickness 50 mm, Paving bitumen of any penetration) all as specified and directed. |
| 149 | M&L for Preparing Bitumen macadam surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc and Applying evenly a priming/tack coat with bituminous primer of paving bitumen(Paving Bitumen VG-10) at 5 kg per 10 sq metre all as specified and directed. |
| 150 | M&L for 40 mm thick (Consolidated thickness ) bituminous premixed ashphaltic semi dense Concrete with marshal stability 1050 kg using binder (VG -30) @5.5% by weight of total mix, Mixed in automatic hot mix plant & Layed in single Layer using self propelled mechanical paver rolled and compacted to required gradient @ camber with power / tandem @ pneumatic roller to achieve a uniform smooth surface etc. complete all as specified and directed. |
| 151 | Supply,laying and compacting 100mm thick (compacted thick )Granular sub base course (GSB) grading as per Grade I as specified Table 400- 1 of MoRTH specifications for Road and Bridge work, 2013, in a single layer over compacted subgrade with natural sand crushed gravel, crushed stone, crushed slag, or combination thereof as per grading required. The material are mechanically mixed spread and levelling on subgrade by using motor grader of adequate capacity, and rolling with vibratory roller of capacity 80-100 KN static weight for achieving required compaction densityof atleast 98% of maximum dry density.Consolidating to required gradient and camber all as specified and directedwith finished surface tolerance as per Table 900-1 of MoRTH Soecifications for road and bridge work , 2013 |
| 152 | M&L for Providing and laying at or near ground level factory made kerb stone of size 300x250x100 mm of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. |
| 153 | M&L for preparation bituminous surfaces of Road and marking 2.5 mm thick centre line,stop line, dashes, arrows, etc. and the like n. exc 10 cm wide on road pavements with hot applied thermoplastic road marking paint of approved colour conforming to BS 3262 - 1989 with special applicator machine all as per manufacturer instruction complete all as specified and directed. |
| 154 | Supply and fix solar cat eye aluminum alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono rystafie solar panel 2.4V/ 0.3 watt one NI-ed rechargeable battery (1.2V/ 1600MA) consisting of super bright LED with 10,000 to 18,000 mcd completed as per manufactures instructions etc. all as specified and directed |
| 155 | M&L 75mm thick PCC type D-2, (1:4:8) using 40mm graded stone aggregate as in path, complete all as specified and directed. |
| 156 | M & L for Sand filling under floors or in foundation including watering & consolidation, complete all as specified and directed. |
| 157 | M & L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and no pigments, complete all as specified and directed. |
| 158 | M& L for Plain cement concrete of grade 1:2:4 type B1 as in foundation, surafce drain filling and mass concrete all as specified and directed. |
| 159 | Supply & Fixing Re-inforced concrete drain pipes of 300 mm dia class NP-3 laid and jointed complete with collors |
| 160 | M&L for old size brick work with fly ash bricks in CM 1:4 straight on curved on plan exc 6m mean radius complete all as specified and directed |
| 161 | M & L for Rendering 15mm thick cement plaster of 1:3 on fair faces of brick work or concrete surface to be finished even and smooth without using extra cement. |
| 162 | M&L for Two coat cement base paint over a coat of alkali resistant primer on new plastered surface including preparation of surface complete all as specified and directed. |
| 163 | M&L for PCC (1:2:4) Type B0 (using 12.50 mm graded stone agg) as in coping including rounded or chamfered or chamfered angles complete all as specified and directed. |
| 164 | M&L for Hardcore of broken stone aggregate of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface all as specified and directed. |
| 165 | M&L for PCC in foundations, filling and mass-concrete type D2 (1:4:8) using 40 mm graded stone aggregate |
| 166 | M&L RCC M-25 design mix using 20 mm graded aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete |
| 167 | M & L for Forming 20 mm thick Expansion joints for 200 mm thick concrete filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing com pound, Grade ‘A’ all as specified and directed. |
| 168 | M & L for Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound of grade A All as specified and direcrtede. Total amount of Schedule ‘A’ Part-VIII carried over to BOQ Rs 25832652.7 Signature of Contractor AAD (Contracts) For Accepting Officer SCHEDULE ‘A’ PART- IX FENCING AND GATE Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 169 | M&L PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) foundation fillings and mass concrete complete all as specified and directed. |
| 170 | M&L PCC 1:2:4 type B-2 (using 40mm graded stone aggregates) foundation fillings and mass concrete complete all as specified and directed. |
| 171 | Use and waste formwork on flat surfaces to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter fair finished surfaces of concrete complete all as specified and directed |
| 172 | Use and waste form work to sides of column, pillars shape as square, rectangular or polygon for fair finished surfaces complete all as specified and directed. |
| 173 | M&L for reinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregate as in foundation including rafts, footings, foundation beams, plinth beams, bases for columns, etc complete all as specified & directed |
| 174 | M&L for reinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregate as in columns, piers, posts and struts complete all as specified and directed |
| 175 | S&F for Mild steel (TMT) bars 10mm dia and over, cut to length, bent to shape required, ncluding cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. |
| 176 | S&F for Mild steel (TMT) bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders , cut to length, bent to shape required, ncluding cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. |
| 177 | M & L for Hand rails, half round or other steel section or core for wooden hand-rail straight portion,drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts and similar work conforming to Fe - 290 Gde E- 165 |
| 178 | M & L for 15 mm thick cement plaster on fair faces of brick work or concrete surfaces in CM 1:4 and finished even and smooth without using extra cement complete all specified and directed. |
| 179 | M&L for preparation of new (Previously untreated) plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali-resitant primer on walls, complete all as specified and directed |
| 180 | M&L for mild steel Framed structural work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing of Fe-290-0 (Gde-E-165) complete all as directed by Engr-in-charge. |
| 181 | M&L for preparation of newly untreated steel surface and applying two coats of synthetic enamel paint over a coat of Red oxide primer exc 10 cm width or girth, not otherwise described complete all as specified and directed. |
| 182 | S & F hot dip Galvanised (having zic coating 260 to 280 GSM). 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) |
| 183 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provission of binding wire |
| 184 | M&L for brick work with fly ash bricks(Old size) straight or curved on plan exceeding 6 M mean radius, using old size bricks built in CM 1:6 complete all as specified and directed by Engineer - in- Charge. |
| 185 | M & L for 15 mm thick cement plaster on fair faces of brick work or concrete surfaces in CM 1:6 and finished even and smooth without using extra cement, complete all as specified and directed by Engineer - in- Charge. |
| 186 | M & L for preperation of new plastered or unplastered surfaces and applying three coat of white wash complete all as specified and directed by Engineer - in- Charge. |
| 187 | M & L for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long dia of neck 5 to 10 mm, |
| 188 | M & L for Sanding newly tarred or painted surfaces with clean sharp sand |
| 189 | M & L for new or preiously untreated Surfaces of any description, n.exc10cm in width or girth when unconnected with other painting or whenpainted in a different tint Total amount of Schedule ‘A’ Part-IX carried over to BOQ Rs 1940854.48 Signature of Contractor AAD (Contracts) For Accepting Officer SCHEDULE ‘A’ PART- XAIR CONDITIONING AND REFRIGERATION WORK Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 190 | Supply and install hi wall split units indoor/outdoor complete withcordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 1.5 TR, complete all as specified and directed. |
| 191 | S & F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB single pole 20 Amps 240 volts |
| 192 | M & L for submain wiring, as per colour coding using PVC insulated single 6 Sqmm two run alongwith earth wire 6 Sqmm in 25 mm dia PVC conduit surface/ recessed , complete all as specified and directed.NOTE :- 02 Run of 6 Sqmm main wire and 01 run of 6 Sqm as earth wire including PVC pipe will be measured as one unit. Total amount of Schedule ‘A’ Part-X carried over to BOQ Rs 275807.4 Signature of Contractor AAD (Contracts) For Accepting Officer SCHEDULE ‘A’ PART- XIEARTH WORK, SITE CLEARANCE & DEVELOPMENT Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 193 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out |
| 194 | M&L for surface dressing not exceeding 15cm deep in soft/loose soil complete all as specified and directed |
| 195 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil. |
| 196 | Excavating in trenches, n exc 1.5 m wide, exc 1.5 m in depth but n exc 3.0 m for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil. |
| 197 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. |
| 198 | Removal of excavated material not exceeding 50 mtr and deposintg where directed at a level n.exceeding 1.5 m above the starting point complete all as specified and directed. |
| 199 | Removal of excavated material exceeding 100 mtr but not exc 250 mtr and deposintg where directed at a level n.exceeding 1.5 m above the starting point complete all as specified and directed. |
| 200 | Removal of excavated material exceeding 250 mtr but not exceeding 500 mtr and deposintg where directed at a level n.exceeding 1.5 m above the starting point complete all as specified and directed. |
| 201 | Excavation in post holes or (similar holes) each n exc 0.50 Cum in soft/loose soil, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers n exc 25cm watering and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and directed. |
| 202 | Excavation over area's not exc 1.5 mtr deep and getting out in soft / loose soil, complete all as speciifed and directed. Total amount of Schedule ‘A’ Part-XI carried over to BOQ Rs 4191616.57 Signature of Contractor AAD (Contracts) For Accepting Officer Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
| 9 | Click here to download tender document | Tender Documents |
| 10 | Click here to download tender document | Tender Documents |
| 11 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail