| 1 | Comprehensive / Routine Maintenance of 02 Nos. Carrier Make Water-Cooled Chillers (Model: 30HXC190A, Capacity: 190 TR each, Sl. Nos: HJ1118 & HJ1116), AC Plant executed strictly through the OEM (M/s Carrier) including routine preventive inspections, 24/7 breakdown support, and the repair or replacement of all mechanical and electrical components including compressors, controls, and refrigerants to ensure peak operational efficiency following the successful completion of overhauling work all as specified and as directed. |
| 2 | Comprehensive / Routine Maintenance of 01 No. Bluestar Make Water-Cooled Chillers (LCW1-210V082525 Make:- Blue Star , Ser No VF08 AR1220281M3 ) , AC Plant including routine preventive inspections, 24/7 breakdown support, and the repair or replacement of all mechanical and electrical components including compressors, controls, and refrigerants to ensure peak operational efficiency following the successful completion of overhauling work all as specified and as directed. |
| 3 | Note for item no 1 & 2 -:(i) Water and Electric required for operation of plant shall be provided free of cost by the Department.(ii) After handing over of plant to contractor . Contractor shall fully responsible for satifactory performance of plant parameters during complete duration of contract period. During Comphensive maintance period any type of fault ( Major & Minor ) occurs in chiller plant contractor shall attend and rectify it without cost . No payment is admisible in this account to contractor. (iii) Contractor shall procure and provide all day to day consumable items such as refrigent gas and grease, sensors, electrical and electronic cards, control and power wirings, lugs sundry items etc reqired for operation of chiller AC plant shall be provided by contractor at his own cost . The quoated rate also include the periodical descaling of condenser coil , chemical cleaning of cooling tower fins and filters as per OEM recommendations and direction of GE during the period of defect liability . The cost of the same shall be deemed included in the unit rates quoted by the contractor.(iv) Contractor should produce MOU of agreement between OEM (carrier and Blue Star) & contractor firm from Whom contractor should carry out the comprehensive maintenance of compressor for 11 months time after completion of overhauling work. The After due varification from OEM chiller plant shall be handed over to contractor for comprehensive maintenance for 11 months.(v) In case contractor fails to attend fault within 24 hr after intimation by the department , he shall be liable to bear the recovery @ Rs 1500 /- per Hr and department shall rectify the fault through other agency on contractor risk and cost and amount shall be recovered from contractor dues.(vi) Tradesman will take all preventive measures as per code of practice of EI Rules and the Department will not be responsible for any type of untowards incident.(vii) Contractors shall provide all kind hand tools,tester, test lamp without any extra cost as per OEM recommendations. |
| 4 | M&L for taking out Condenser Motor 25HP Capacity 720 rpm 3 phase 415 volt , opening the motor, cutting & removing old and burnt winding wire, rewinding the motor With new super enameled copper winding of suitable size including bearing insulating materials, varnishing, drying, replacement of both driven end , non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed by engineer in charge. Note: The quoated rates must include loading & unloading with to and fro transportation for workshop and vice versa |
| 5 | M&L for taking out Chiller Plant Primary & Secondry Motor 20 HP Capacity 720 rpm 3 phase 415 volt , opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of suitable size including bearing insulating materials, varnishing, drying, replacement of both driven end,non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed by engineer in charge. Note: The quoated rates must include loading & unloading with to and fro transportation for workshop and vice versa |
| 6 | Material and Labour for dismantling of existing Air Handling Unit of any capacity upto 32000 CFM , cleaning, servicing, overhauling to all component of AHU, with and including cleaning of heating & cooling coil with caustic soda solution, including welding / brazing, wherever required to arrest leakages, cleaning of Pre-Micro Filters, replacing of vertical GI sheet supports, complete replacement of foam insulation of best quality using adhesive substance to avoid cold air leakages, fabrication of bottom GI tray of existing size with drain pane made out of 16 guage thick GI Sheets duly painted with bituminous paint over interior surface of tray, re-assembling all the dismantled components to its original position using new nut, bolt, washer and other packing material etc, with and including testing, commissioning of Air handling Unit at optimum efficiency, complete all as directed by Engineer -in-charge. |
| 7 | S&F in repair AHU fan belt of Size B-82 complete as specified and directed by Engineer-in-charge. |
| 8 | S&F in repair AHU fan belt of Size B-101 complete as specified and directed by Engineer-in-charge. |
| 9 | S&F in repair AHU fan belt of Size B-116 complete as specified and directed by Engineer-in-charge. |
| 10 | S&F in repair AHU fan belt of Size B-124 complete as specified and directed by Engineer-in-charge. |
| 11 | S&F in repair AHU fan belt of Size B-138 complete as specified and directed by Engineer-in-charge. |
| 12 | S&F in repair AHU fan belt of Size B-145 complete as specified and directed by Engineer-in-charge. |
| 13 | S&F in repair AHU fan belt of Size B-146 complete as specified and directed by Engineer-in-charge. |
| 14 | Supply and fix in replacement of industrial type mercury thermometer complete all as specified and directed. |
| 15 | M & L in replacment of unserviceable 2/3 way modulating motorized valve including actuator, Thermostate, LED Display with temperature display,GI globe body, Brass seating,SS-304 spindle ,Telflon gland,with linear movement actuator 24V AC input supply, 0-10V input signal with modulating thermostate & transformer of size-40 mm. |
| 16 | M & L in replacment of unserviceable 2/3 way modulating motorized valve including actuator, Thermostate, LED Display with temperature display,GI globe body, Brass seating,SS-304 spindle ,Telflon gland,with linear movement actuator 24V AC input supply, 0-10V input signal with modulating thermostate & transformer of size-50 mm. |
| 17 | M&L for taking out Cooling Tower Motor 10HP Capacity 720 rpm 3 phase 415 volt , opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of suitable size including,bearing insulating materials, varnishing, drying, replacement of both driven end,non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed by engineer in charge. Note: The quoated rates must include loading & unloading with to and from transportation for workshop and vice versa |
| 18 | M&L dismantalling AHU induction motor from AHU base plate inside and arranging the necessary adjusting from fan belt, and then repairing /servicing AHU Fan Motor, following capacity given as under, opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of suitable size including insulating materials, varnishing, drying, replacement of both driven end, non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed Note: The quoated rates must include loading & unloading with to and fro transportation for workshop and vice versa. |
| 19 | 7.5 HP AHU fan motor, 1454 RPM, HX+132MLE4. |
| 20 | 10 HP AHU fan motor, 1450 RPM, HX+132MLE4. |
| 21 | 12.5 HP AHU fan motor, 1455 RPM, HX+160MLB4. |
| 22 | 15 HP AHU fan motor, 1450 RPM, HX+160MLE4. |
| 23 | 20 HP AHU fan motor, 1450 RPM, HX+160MLE4. |
| 24 | Material & Labour for rewinding of electric motor 1.5 /2 HP, 415 volts, three phase, using Super enameled copper winding wire of gauges equal to or more than existing including replacement of sheet 'E' class insulation and sleeve Including the following jobs (a) Reassembling the motor & refixing (b) Cleaning washing ball bearing with kerosene Oil, greasing with new grease of make Castrol Refixing to its original position testing and Commission complete all as specified and directed by Engineer-in-charge. |
| 25 | Material & Labour for rewinding of electric motor 1.5 HP, 240/230 volts, single phase, using Super enameled copper winding wire of gauges equal to or more than existing. Including replacement of sheet 'E' class insulation and sleeve Including the following jobs: (a) Reassembling the motor & refixing (b) Cleaning washing ball bearing with kerosene Oil, greasing with new grease of make Castrol Refixing to its original position testing and Commission complete all as specified and directed by Engineer-in-charge. |
| 26 | S&F Float valve assembly of any size as required in cooling tower complete all as specified and directed. |
| 27 | Supply only PVC spray assembly / Nozzels of any size in cooling tower as required complete all as specified and directed. |
| 28 | S&F fan blade assembly of cooling tower of cooling tower 225TR capacity as per existing assembly including dismantling old unserviceable blades complete all as specified and directed. |
| 29 | S&F PVC Fills complete all as specified and directed by Engineer -in-charge. |
| 30 | Repair & Replacement of Spray Header for 200/225TR Cooling tower complete all as specified and directed. |
| 31 | Supply & fixing in replacement Start/ stop Button for Starter Pannels as required at site. |
| 32 | Supply & fixing in replacement thermal overload relays type MN directly operated & direct mounting on MNX, of relay range 9-15A. Model MN2. |
| 33 | Supply & fixing in replacement thermal overload relays type MN directly operated & direct mounting on MNX, of relay range 14-23A. Model MN2. |
| 34 | Supply & fixing in replacement thermal overload relays type MN directly operated & direct mounting on MNX, of relay range 20-33A. Model MN2. |
| 35 | Supply & fixing in replacement Power Contactor type MNX of size Fr1, suitable for existing starter pannel. Model MNX 12. |
| 36 | Supply & fixing in replacement Power Contactor type MNX of size Fr1, suitable for existing starte pannel. Model MNX 18. |
| 37 | Supply & fixing in replacement Power Contactor type MNX of size Fr1, suitable for existing starter pannel. Model MNX 25. |
| 38 | Supply & fixing in replacement Power Contactor type MNX of size Fr1, suitable for existing starter pannel. Model MNX 32. |
| 39 | Supply & fixing in replacement Power Contactor type MNX of size Fr1, suitable for existing starter pannel. Model MNX 40. |
| 40 | S& F in replcement Top-Mounting Auxiliary Contact Block, Model L&T MNX A2 , designed for snap-fit integration with MNX series power contactors (9A to 40A). The unit shall feature a 1NO + 1NC (one normally open and one normally closed) contact configuration, rated for a current of 6A at 240V AC or 10A at 415V AC (50Hz) complete in all aspect all as specified and as directed. |
| 41 | S&F microprocessor-based Electronic Timer Switch (Series 800S), featuring a multi-function LED display and programmable time ranges (typically 0.1s to 999h); the unit shall support cyclic (ON-OFF) or sequential timing modes with high repeat accuracy of 0.5 and suitable for DIN-rail mounting, operate on a universal supply voltage (24-240V AC/DC), and include at least one set of 5A NO/NC changeover contacts complete in all aspect all as specified and as directed. |
| 42 | M&L for taking out Vertical Motor 2.5HP Capacity 3 phase 415 volt opening the motor, cutting & removing old and burnt winding wire, rewinding the motor With new super enameled copper winding of suitable size including,bearing insulating materials, varnishing, drying, replacement of both driven end.non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed by engineer in charge Note: The quoated rates must incl. loading & unloading with to and fro transportation for workshop and vice versa |
| 43 | M&L for taking out Vertical Motor 5HP Capacity 3 phase 415 volt opening the motor, cutting & removing old and burnt winding wire, rewinding the motor With new super enameled copper winding of suitable size including,bearing insulating materials, varnishing, drying, replacement of both driven end.non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed by engineer in charge Note: The quoated rates must incl. loading & unloading with to and fro transportation for workshop and vice versa |
| 44 | S&F in repair MCCB, 4 Pole, 63 Amps, 415 Volts, adjustable type with breaking capacity 16 KA complete all as specified and as directed. |
| 45 | S&F in repair MCCB, 4 Pole, 100 Amps, 415 Volts, adjustable type with breaking capacity 16 KA complete all as specified and as directed. |
| 46 | S&F in repair MCCB, 4 Pole, 125 Amps, 415 Volts, adjustable type with breaking capacity 16 KA complete all as specified and as directed. |
| 47 | S&F in repair MCCB, 4 Pole, 160 Amps, 415 Volts, adjustable type with breaking capacity 36 KA complete all as specified and as directed. |
| 48 | S&F in repair MCCB, 4 Pole, 200 Amps, 415 Volts, adjustable type with breaking capacity 36 KA complete all as specified and as directed. |
| 49 | S&F in repair MCCB, 4 Pole, 250 Amps, 415 Volts, adjustable type with breaking capacity 36 KA complete all as specified and as directed. |
| 50 | S&F in repair MCCB, 4 Pole, 400 Amps, 415 Volts, adjustable type with breaking capacity 36 KA complete all as specified and as directed. |
| 51 | S&F in repair MCCB, 4 Pole, 630 Amps, 415 Volts, adjustable type with breaking capacity 50 KA complete all as specified and as directed. |
| 52 | M&L for servicing/ Maintenance & repairing of 1100 V, LT ACB panels including dusting, oiling, setting of over current and earth fault relay, if required, laid and servicing like all mechanical function including replacement of no volt coil tripping device complete all as specified and as directed. |
| 53 | S&F in replacement Air Circuit breakar 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 1250 Amps complete all as specified & directed. |
| 54 | S&F in replacement Air Circuit breakar 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 1000 Amps complete all as specified & directed. |
| 55 | Comprehensive repair and maintenance of the 750 KVA DG set installed at CGDA complex through a specialized Annual Maintenance Contract (AMC) to be executed strictly by the Original Equipment Manufacturer (OEM) i.e M/S Cummins or their authorized service partners.The bidder must submit a formal Memorandum of Understanding (MOU) or a valid authorization letter from the OEM specifically for this project along with the tender documents. |
| 56 | Supply only Element ,Lube oil filter (CIL- 3238204) complete in all aspect all as specified and as directed. |
| 57 | Supply only Kit, fuel filter and ring (CIL- 3238493) complete in all aspect all as specified and as directed. |
| 58 | Supply only Kit, super bypaas filter element (CIL- 3879488) complete in all aspect all as specified and as directed. |
| 59 | Supply only seal \\"O\\" Ring (CIL- 3010937) complete in all aspect all as specified and as directed. |
| 60 | Supply only foil shield test strips CC2601B (CIL- 3403800) complete in all aspect all as specified and as directed. |
| 61 | Supply only Kit, Air cleaner element (CIL- 3238665) complete in all aspect all as specified and as directed. |
| 62 | Supply only Kit, rectifier service (RSK-6001) complete in all aspect all as specified and as directed. |
| 63 | Supply only funnel duel fuel filter (AX 1015648) complete in all aspect all as specified and as directed. |
| 64 | Supply only inhibitor, corrosion (CIL- 3816986) complete in all aspect all as specified and as directed. |
| 65 | Supply only inhibitor, corrosion (CIL- 3816981) complete in all aspect all as specified and as directed. |
| 66 | Supply only in topup radiwash (AX1013508) complete in all aspect all as specified and as directed. |
| 67 | Supply only inhibitor, corrosion (CIL- 4326654) complete in all aspect all as specified and as directed. |
| 68 | Supply only indicator restricion (CIL- 3872813) complete in all aspect all as specified and as directed. |
| 69 | Supply only VCL Premium Bue 7800 Plus complete in all aspect all as specified and as directed. |
| 70 | Comprehensive repair and maintenance of the 250 KVA DG set installed at CGDA complex through a specialized Annual Maintenance Contract (AMC) to be executed strictly by the Original Equipment Manufacturer (OEM) i.e M/S Cummins or their authorized service partners.The bidder must submit a formal Memorandum of Understanding (MOU) or a valid authorization letter from the OEM specifically for this project along with the tender documents. |
| 71 | Supply only B Check Kit, 6CTA (3238543) complete in all aspect all as specified and as directed. |
| 72 | Supply only Kit Air Cleaner element complete (3238668) in all aspect all as specified and as directed. |
| 73 | Supply only inhibitor, corrosion (CIL- 3816986) complete in all aspect all as specified and as directed. |
| 74 | Supply only inhibitor, corrosion (CIL- 3816986) complete in all aspect all as specified and as directed. |
| 75 | Supply only seal, rocker lever cover (4926654) complete in all aspect all as specified and as directed. |
| 76 | Supply only Kit, rectifier service (RSK-6001) complete in all aspect all as specified and as directed. |
| 77 | Supply only foil shield test strips CC2601B (CIL- 3403800) complete in all aspect all as specified and as directed. |
| 78 | Supply only indicator restricion (CIL- 3872813) complete in all aspect all as specified and as directed. |
| 79 | Supply only in topup radiwash (AX1013508) complete in all aspect all as specified and as directed. |
| 80 | Supply only funnel duel fuel filter L (AX 1015648) complete in all aspect all as specified and as directed. |
| 81 | Supply only VCL Premium Bue 7800 Plus complete in all aspect all as specified and as directed. |
| 82 | Comprehensive repair and maintenance of the 320 KVA DG set installed at CENTRAD complex through a specialized Annual Maintenance Contract (AMC) to be executed strictly by the Original Equipment Manufacturer (OEM) i.e M/S Mahindra or their authorized service partners.The bidder must submit a formal Memorandum of Understanding (MOU) or a valid authorization letter from the OEM specifically for this project along with the tender documents. |
| 83 | Supply only Oil Filter Assy complete all as specified and as directed. |
| 84 | Supply only Bypass Oil filter complete all as specified and as directed. |
| 85 | Supply only fuel filter complete all as specified and as directed. |
| 86 | Supply only water seprator cartridge complete all as specified and as directed. |
| 87 | Supply only adopter complete all as specified and as directed. |
| 88 | Supply only Air cleaner element Outer complete all as specified and as directed. |
| 89 | Supply only Air cleaner element Inner complete all as specified and as directed. |
| 90 | Supply only super premium valovoline cane complete all as specified and as directed. |
| 91 | Supply only coolant complete all as specified and as directed. |
| 92 | Supply only hose turbo-charger complete all as specified and as directed. |
| 93 | Supply only hose inter cooler complete all as specified and as directed. |
| 94 | Supply only hose radiator water outlet connection complete in all aspect all as specified and as directed. |
| 95 | Supply only hose reducer water inlet connection complete in all aspect all as specified and as directed. |
| 96 | Supply only tube radiator water inlet connection complete in all aspect all as specified and as directed. |
| 97 | Supply only Clamp SAE complete in all aspect all as specified and as directed. |
| 98 | Supply only Clamp TB-52 complete in all aspect all as specified and as directed. |
| 99 | Supply only Clamp TB-60 complete in all aspect all as specified and as directed. |
| 100 | Supply only TB-108 complete in all aspect all as specified and as directed. |
| 101 | Supply only hose Vent complete in all aspect all as specified and as directed. |
| 102 | Supply only clamp coolent intermediate hose complete in all aspect all as specified and as directed. |
| 103 | Supply only Belt 10 PK 1815 complete in all aspect all as specified and as directed. |
| 104 | Supply only Battery Charger 24 Volt complete in all aspect all as specified and as directed. |
| 105 | M&L for cleaning of radiator complete in all aspect all as specified and as directed. |
| 106 | M&L for Diesel Tank Cleaning complete in all aspect all as specified and as directed. |
| 107 | S&F in repair fuel pipe set suitable for 750KVA, 320 KVA, 250 KVA DG set complete all as specified and directed. |
| 108 | S&F in repair battery, SMF, 12 Volt,180AH capacity complete all as specified and as directed. |
| 109 | S&F in repair battery, SMF, 12 Volt,150AH capacity complete all as specified and as directed. |
| 110 | S&F in repair battery lead with stranded copper conductor of size 95/70 Sqmm, single core, PVC insulated, flexible, 0.6 M long along with battery terminal for positive and stator terminal duly soldered complete all as specified and as directed. |
| 111 | S&F in replacement fuse base suitable for cylindrical/DIN type HRC/HBC fuse link type 630/400 A for AMF panel for 750 KVA DG Set complete all as as specified and as directed. |
| 112 | S&F in replacement fuse base suitable for cylindrical/DIN type HRC/HBC fuse link type 630/400 A for AMF panel for 320 KVA DG Set complete all as as specified and as directed. |
| 113 | S&F in replacement fuse base suitable for cylindrical/DIN type HRC/HBC fuse link type 630/400 A for AMF panel for 250 KVA DG Set complete all as as specified and as directed. |
| 114 | Note For item No. 55 , item no 70 and Item No 821.Preventive Maintenance: Execution of all mandatory periodic services, including replacement of Engine Oil, Coolant, Fuel Filters, Oil Filters, Air Filters, and all associated consumables (The item should be measure and paid seperatly in repective item of this schedule).2.Breakdown Maintenance: Unlimited call-outs for emergency breakdown repairs, including all required labor and consumables.3.Replacement of Parts: Replacement of all non-structural, wear-and-tear components (e.g., fan belts, hoses, sensors, batteries, minor electrical components, etc.) that fail or require replacement during the contract period to ensure operational readiness. Excludes major engine overhaul components (e.g., block, crank, major alternator winding).4.Testing and Load Trials: Quarterly load banking or on-load testing of the DG set for a minimum duration of 1 hour, documenting performance parameters (voltage, frequency, current, oil pressure, temperature).5.Logbook and Reporting: Maintaining a comprehensive service logbook and providing detailed service reports after every PM visit and breakdown call. |
| 115 | General Terms and Condition For item No. 55 , item no 70 and Item No 82(i) All work shall be carried out only by authorised Rep of OEM and using all genuine spare parts supplied by OEM only.(ii) Contractor should be responsible of proper functioning of all the system from current condition (either in malfunctioning or working) in the initial phase of contract and rate for for the same shall be included in the quoted. Nothing extra in that respect shall be paid to the contractor.(iii) Contractor through OEM shall be responsible for repair and replacement of all defective parts of the equipment as per OEM recommendation during entire comprehensive maintenance period.(iii) Preventive maintenance of all systems on monthly basis.(iv) Attending all complaints within 24 working hours intimated by Engg-in-Charge.(v) Field service report shall be maintained and submitted to the Engg-incharge after expiry of every month and before submission of RAR .(vi) The rates quoted by the contractor shall deemed to be inclusive of T&P etc |
| 116 | Supply, installation, testing, and commissioning of a Kirloskar Brothers Limited Horizontal End Suction Induction Motor-Pump set, Type KDL-1030+, having a rated output of 7.50 kW (10 HP), 3-Phase, Delta connected, operating at 415V, 50Hz with a synchronous speed of 2900 RPM. The unit features a size of 100x100 mm, designed for a nominal head of 25 meters (range 18 to 29 meters) and a discharge capacity of 22 l/s (range 28 to 15 l/s), featuring Class F insulation, IP44/54 protection, and rated for continuous Duty S1, including all necessary foundation bolts and accessories as per site requirements. |
| 117 | S&F in repalcement power contactor series CK- 3 pole, AC control 630 A, suitable for AMF panel of 750 KVA DG Set complete all as as specified and as directed. |
| 118 | S&F in repalcement power contactor series CK- 3 pole, AC control 400 A, suitable for AMF panel of 320 KVA DG Set complete all as as specified and as directed. |
| 119 | S&F in repalcement power contactor series CK- 3 pole, AC control 250 A, suitable for AMF panel of 250 KVA DG Set complete all as as specified and as directed. |
| 120 | S&F in repair single Phase Preventor as per sample complete all as specified & directed. |
| 121 | S&F in repair Engine Starting Relay as per sample at site complete all as specified & directed. |
| 122 | S&F in repair selector switch as per sample at site complete all as specified & directed by Engineer-in-charge. |
| 123 | S&F in repair On-Delay timer of 230 VAC, Range: 0 to 30 sec complete all as specified & directed. |
| 124 | S&F in repair Under Voltage relay 240/415 Volt as per sample at site complete all as specified & directed. |
| 125 | Supply, laying & connecting in repair single core, copper conductor, PVC insulated, unsheathed, 1100 V grade (FRLS), 56/0.30, flexible, 4 Sqmm complete all as specified & directed. |
| 126 | Supply, laying & connecting in repair single core, copper conductor, PVC insulated, unsheathed, 1100 V grade (FRLS), 84/0.30, flexible, 6 Sqmm complete all as specified & directed. |
| 127 | S&F in repair single phase under voltage relay 20-110V AC/DC CT Secondry 5A complete all as specifed and as directed. Make L&T Cat Part No MV12AA00X00 or equivalent Model of Seimens/Schinder or any other Make mentioned in PS. |
| 128 | S&F in repair 3 Phase over current, earth fault relay 20-110V AC/DC 4 No programmable complete all as specifed and as directed. Make L&T Cat Part No MC31AAXX000 or equivalent Model of Seimens/Schinder or any other Make mentioned in PS. |
| 129 | S&F in repair 3 Phase over current , earth fault relay 20-110V AC/DC CT Secondry 5A complete all as specifed and as directed. Make L&T Cat Part No MRP11A50X00 or equivalent Model of Seimens/Schinder or any other Make mentioned in PS. Please Enable Macros to View BoQ information |
| 130 | S&F in repair 3 Phase over current , earth fault relay 20-110V AC/DC CT Secondry 5A complete all as specifed and as directed. Make L&T Cat Part No MRP11A50X00 or equivalent Model of Seimens/Schinder or any other Make mentioned in PS. Please Enable Macros to View BoQ information |