| 1 | Dismantling fencing wire mesh, any type and specification, complete all as specified and directed. |
| 2 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standard rails, straining bolts etc including provn of binding wire, complete all as specified and directed. |
| 3 | Supply only chain link MS galvanated fencing any size fixed to any type of stander rail n exc 3 kg per sqm, complete all as specified and directed. |
| 4 | S&F mild steel security chain link fencing 60mmx60mm with PVC coated mesh made out of 3mm dia MS wire and 1.00mm thick PVC coating throughout fixed to RCC post including binding wire complete all as specfied and directed. |
| 5 | S&F in repair galvanised 2 strand barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to Angle iron post complete all as specified and directed. |
| 6 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed gound complete all as specified and directed. |
| 7 | Excavating in post holes (or similar holes) each n exc 0.5 cu. M, getting out, returning, filling in and raming earth or broken , in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and directed. |
| 8 | M&L posts and struts for fencing and other steel section including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed. |
| 9 | Dismantling floor hearth or wall/stone tiling including cement mortar bedding (but not backing ) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 10 | Glazeded ceramic coloured black tile 450x300x6-7mm thick on vertical surface such as gate pillars set and jointed in neat cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white/ coloured cement with pigment to match the colour of tiles, complete all as specified and directed. Note ;- The Colour of wall tiles Black/design shade approved by Engr -in - charge. |
| 11 | Demolition of brick work built in cement mortar of any specification any size and in any position complete all as specified and directed. |
| 12 | M & L brick work with sub class ‘B’ old sized bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 13 | M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 but using old bricks retrieved from dismantling under item 15 herein before including cleaning and removal of mortar from old bricks. complete all as specified and directed. |
| 14 | Taking down cement plaster on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water , etc complete all as specified and directed. |
| 15 | M&L for Rendering 15mm thick on any faces of brick or concrete surfaces in CM 1:4 finished fair and even without using extra cement complete all as specified and directed. |
| 16 | M&L for preparing newly plastered surface and applying two coats of cement base paint on wall surfaces complete all as specified and directed. |
| 17 | M&L for preparation of newly plastered surface of wall and applying three coats of white wash over walls complete all as specified and directed. |
| 18 | Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified and directed. |
| 19 | Dismantling Stone slabs and tiles of any description or thickness in floors, aprons laid bedded , dry and pointed etc, complete all as specified and directed. |
| 20 | M & L sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in-charge . |
| 21 | Cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base of floor topping, 75 mm thick, complete all as specified and directed. |
| 22 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thick M-35 with grey cement and pigment complete all as specified and directed. Note :- The colour of tiles Red/Yellow approve by Engr -in -charge. |
| 23 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thick M-40 with grey cement and pigment complete all as specified and directed. Note :- The colour of tiles Red/Yellow approve by Engr -in -charge. |
| 24 | All as per item no-22, but except tiles, complete all as specified and as directed. |
| 25 | M&L for Granite(of any type) tiles18- 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 10 mm thick plaster as in back coat CM 1:4 complete including making circular gas pipe hole, moulding at corners and polishing type complete all as specified and directed. |
| 26 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 27 | M&L for Chequered cement concrete tiles (coloured) 300mm X 300mm X 25 mm thick thick heavy duty, chmecially treated Chequred/pavement tiles of size and shape as approved over 15mm thick screed bed in CM 1:6, set and jointed in neat cement siurry and pointed with grey cement mixed complete all as specified and directed. Note :- The colour of tiles Red/Yellow approve by Engr -in -charge. |
| 28 | M&L for Cement concrete 1:2:4 type B-2 using (40mm crushed graded stone aggregate) 75mm thick as in floor in alternate pannel pattern, finished top surfaces even and smooth without using extra cement all as specified and directed. |
| 29 | M&L Plain cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed. |
| 30 | Dismantling structural steel work including doors, gate but excluding framed truss complete all as specified and directed. |
| 31 | S&F Mild steel framed work of (Fe-290 Gde-E-165) as in doors or gate of angle or other section with gusset plates,rails, braces etc and fixing complete all as specified and directed. |
| 32 | Preparation of New steel surfaces of any description and in any position over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of redoxide primer. complete all as specified and directed. |
| 33 | M&L painting to old steel surfaces of any description, over 10cm width or girth in one coat with synthetic enamel paint including preparation of surfaces complete all as specified and directed. |
| 34 | Mild steel plain bars 10 mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to complete all as specified and directed. |
| 35 | M&L for PCC 1:3:6 tye C2 (40 mm graded aggregate) as in surface channel and drains complete all as specified and directed. |
| 36 | M&L for MS nuts and bolts (machine made) with hexagonal or square heads at one end and scewed the other or screwed both ends, each screwed end to be provided with one washer and nut complete all as specified and directed. |
| 37 | M&L for providing cement concrete type B1 1:2:4 (20mm graded aggregate) as copings, kneelers, apex stones, bed plates, kerbs, edge of paver block , water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed. |
| 38 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides of cover slabs and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finish surface complete all as specified and directed. |
| 39 | Demolition of reinforced cement concrete in any position not described else where, complete all as specified and directed. |
| 40 | M/L RCC 1:2:4 type B1 using 20mm graded aggregate as in Precast cover slab , shelves and similar articles and setting in mortar 1:6 complete with joints to match, complete all as specified and directed. |
| 41 | S & F Reinforced concrete pipes 300mm bore, class NP3, laid and jointed complete with collars, complete all as specified and directed. Please Enable Macros to View BoQ information |