| 1 | Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth and getting out soft /loose soil complete all as specified and as directed for laying of under ground cable, foundation of pole and stay etc. complete all as specified and as directed |
| 2 | Returning, filling in, including spreading, levelling, watering and well remmining in layers not exc 25 cm complete all as specified and as directed |
| 3 | Removing excavated material n.exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point all as directed. |
| 4 | M&L sand cushioning 8cm below the cable and 15cm above the cable for cable protection in trenches complete all as specified and directed by Engr-in-charge. Note:- After cushioning total thickness measured as 18 cm. |
| 5 | Supply and lay burnt best quality locally available old size sub class 'B' bricks laid in trenches perpendicular to U/G cable for cable protection complete all as specified and as directed. |
| 6 | Laying only serviceable bricks obtained from the items specified here-in-before (i.e during taking out of under ground cable),laid flat dry, in trenches with width of the bricks laid to the axis of cable for protection of cable complete all as specified and as directed |
| 7 | Dismantling of old PCC/steel tubular pole of any size with necessary disconnection of electric wire, demolition of concrete foundation including excavation, earth work as reqd & removing the same from site complete all as specified and as directed. |
| 8 | S&F for octagonal hot dip galvanized street light poles ,height 7 mtrs, top dia 70mm, bottom dia 130mm,thickness 3mm,base plate 220x220x12mm, including necessary foundation and nut bolts as per manufacturer recommendation and galvanized bracket single arm for fixing of street light complete all as specified and directed. (Make- Jindal/Utkarsh/Surya/Bajaj or equivalent as approved by AGE (I)) |
| 9 | Taking out unserviceable LT U/G cable from trenches 35 Sqmm to 50 Sqmm size 3.5 core complete all as specified and as directed. |
| 10 | All as per item No-9 here-in-before but 70 Sqmm to 120 Sqmm. |
| 11 | Supply, laying and testing of LT cable 1100 volt grade XLPE insulated underground electric cable PVC bedded and sheathed steel wire/strip armoured aluminum stranded conductor of size 70 Sq mm 3.5 core. |
| 12 | All as per item No. 11 here-in-before but size of 95 Sqmm 3.5 core |
| 13 | All as per item No. 11 here-in-before but size of 35 Sqmm 3.5 core |
| 14 | All as per item No. 11 here-in-before but size of 50 Sqmm 3.5 core |
| 15 | All as per item No. 11 here-in-before but size of 120 Sqmm 3.5 core |
| 16 | Relaying of existing serviceable underground cable of size 70 Sqmm to 120 Sqmm 3.5 Core obtained from item No 10 complete all as specified and as directed. |
| 17 | Relaying of existing serviceable underground cable of size 35 Sqmm to 50 Sqmm 3.5 core obtained from item No - 9 complete all as specified and as directed. |
| 18 | Boring holes horizontally under road without damaging the surface of road ( minimum 1.0 Metre below the road surface with the help of GI tubing not exc 80 mm bore(dia) for passing UG cable, complete all as specified and as directed. NOTE : - GI Pipe laid will be measured and paid separately under respective item |
| 19 | S&F in replacement of 50 mm bore GI tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and botls/washers complete all as specified. |
| 20 | S&F in replacement of 80 mm bore GI tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and botls/washers complete all as specified. |
| 21 | Supply & fixing straight through joint heat shrinkable of size 25 Sqmm to 50 Sqmm 4/3.5 core LT cable 1100 volts and including taking out old joint Make : M-seal/ Raychem/3M/Denson |
| 22 | ---Ditto--- as item no 21 above but size of 70 Sqmm to 120 Sqmm 3.5 core |
| 23 | ---Ditto--- as item no 21 above but size of 150 Sqmm to 185 Sqmm 3.5 core |
| 24 | ---Ditto--- as item no 21 above but size of 240 Sqmm to 400 Sqmm 3.5 core |
| 25 | Hiring of cable fault detector, to dedect exact position of fault for XLPE LT cable, 1100 Volts grade heavy duty aluminium conductor of any size as required length including transporting charges etc. all as specified and directed. |
| 26 | Material & Labour for PCC (1:2:4) type B-1 using 20 mm graded aggregate as in coping of pole/panel including providing necessary form work complete all as specified and as directed by the Engineer-in-charge |
| 27 | M & L for cable route indicator for 1100 Volts grade cable with 150 mm dia cast iron plate circular or rectangular in shape of minimum 8 mm thickness welded with 35x35x4 mm angle iron mast 0.5 mtr from the GL including PCC foundation 1:3:6 type C1 of size 30x30x45 cm and necessary earth work all as directed. |
| 28 | Repair/replacement & maint of floor mounted outdoor/indoor cubical type LT panel/ Feeder Pillar Box of various sizes including disconnecting all in-coming and outgoing connection after taking necessary shut down, disconnecting burnt MCB/MCCB,bus bar, cleaning the carbon/rust from bus-bar, re-thimbling with new lugs/thimble of existing size incl. hinz,locking arrangement by means of electric welding and segregating the serviceable and un-serviceable items as selector switch,voltmeter, amperemeter with CT removing old burn out wiring.cables and re-fixing the existing position replacement of un-serviceable parts including re-wiring, painting with one coat synthetic enameled paint of existing colour complete all as specified and directed.(Note : a- Spare parts/Items of LT panel/feeder piller box shall be measured and paid seprately under respective items.b: All T&P,safty measures and minor items like PVC tape shall be provided by the contractor without any extra cost) |
| 29 | Supply only Flush mounting 96x96 mm 3ph LED ammeter Cl 1 ,Accuracy class 1.0,0.5,input votage measurement range 50-550 VAC(P-P),inbuilt selector switch for 3 phase mere, CT/PT site programmable.Make : L&T, Schenider & Legrand |
| 30 | Supply only Flush mounting 96x96 mm 3ph LED voltmeter Cl 1 ,Accuracy class 1.0,0.5,input votage measurement range 50-550 VAC(P-P),inbuilt selector switch for 3 phase mere, CT/PT site programmable.Make : L&T, Schenider & Legrand |
| 31 | Supply only Aluminium thimble 25 Sq mm |
| 32 | Supply only Aluminium thimble 35 Sq mm |
| 33 | Supply only Aluminium thimble 50 Sq mm |
| 34 | Supply only Aluminium thimble 70 Sq mm |
| 35 | Supply only Aluminium thimble 95 Sq mm |
| 36 | Supply only Aluminium thimble 120sqmm |
| 37 | S & F in repair MCCB 200 Amps, 4 pole, 415 volts, 50 Hz 36 KA breaking capacity with adjustable thermal magnetic release with spreader link on both sides with existing size and make as suitable to fit in the existing LT FPB. |
| 38 | S & F in replacement MCCB 100 Amps , 3 pole, 415 volts , 50 Hz , 16 KA breaking capacity with adjustable thermal magnetic release, with spreader links on both sides with existing size and make as suitable to fit in the existing LT FPB |
| 39 | S & F in replacement MCCB 63 Amps , 3 pole, 415 volts , 50 Hz , 16 KA breaking capacity with adjustable thermal magnetic release, with spreader links on both sides with existing size and make as suitable to fit in the existing LT FPB |
| 40 | S & F MCB SPN 240 volts, 'C' curve of rating 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables. |
| 41 | S & F MCB TPN 240 volts, 'C' curve of rating 63 amps, with rupturing capacity 10 KA, including providing thimble for out going cables. |
| 42 | S&F of GI perforated cable tray of size 50x100x50 mm with GI tray cover of size 15x105x15 mm made of 16 SWG, fixed to wall/roof with suitable size brackets or hangers as deemed fit as per requirement complete all as specified and directed. Please Enable Macros to View BoQ information |