| 1 | Schedule-A |
| 2 | Taking down Solar water heater for repair /maintenance including servicing capacity upto 300 LPD installed at single/double/triple story bldgs for carrying out minor leakage, cleaning of flat plate collector glass & cleaning of sintex tank and make up tank incl dismantling inlet and out let connection s and re-fixing the same after cleaning for proper functioning to maintain proper water temperature, all as specified and directed by Engr-in-Charge. (Contractor should maintain the repair system complete area qtr as and when reqd) |
| 3 | S&F in replacement flat panel collector suitable for of 100/200/300 liters capacity solar water heater and connecting to existing panels if reqd. arresting any leakage if found complete testing ISI Mark assy suitable for solar water system existing size and capacity with copper with selectively coated black chrome with nickel under coate & tig weeding between copper tube & sheet reflector film of aluminum toughed glass and complete fitting as per sample according to IS:12933 (pt2/2003)and all as directed by Engr-in-Charge. |
| 4 | S&F in replacement toughned glass suitable for solar plant of capacity upto 300 LPD complete all as specified and directed by Engr-in-Charge. |
| 5 | S&F in replacement flange of add on collector (pack of 10) suitable for solar plant of capacity upto 300 LPD |
| 6 | S&F in replacement evacuated glass tube (58mm) suitable for solar plant of capacity upto 300 LPD complete all as specified and directed by Engr-in-Charge. |
| 7 | S&F in replacement silicon ring (pack of 20) suitable for solar plant of capacity upto 300 LPD complete all as specified and directed by Engr-in-Charge. |
| 8 | S&F in replacement tube holder (pack of 20) suitable for solar plant of capacity upto 300 LPD complete all as specified and directed by Engr-in-Charge. |
| 9 | S&F in replacement gaskets (pack of 20) suitable for solar plant of capacity upto 300 LPD, complete all as specified and directed by Engr-in-Charge. |
| 10 | S&F in replacement dead plug of collector (pack of 10) suitable for solar plant of capacity 300 LPD, complete all as specified and directed by Engr-in-Charge. |
| 11 | S&F in replacement washer of collector (pack of 10) suitable for solar plant of capacity upto 300 LPD |
| 12 | S&F in replacement anti rust ring (pack of 20) suitable for solar plant of capacity upto 300 LPD, complete all as specified and directed by Engr-in-Charge. |
| 13 | S&F in replacement storage tank SS grade 304, 316 PUF insulated, suitable for solar plant of capacity 300 LPD, complete all as specified and directed by Engr-in-Charge. |
| 14 | M&L of collector glass/tubing of solar heating system by using colin & water complete all as specified and directed by Engr-in-Charge. |
| 15 | Descaling of Solar Water heating tank and pipe lines by re-circulating descaling solution with pumps complete all as specified and directed by Engr-in-Charge. |
| 16 | S&F in replacement Heating Element of capacity 3KW,AC, 230/415 Volt, complete all as specified and directed by Engr-in-Charge. |
| 17 | S&F in replacement Thermostate suitable for 0 -100 degree, AC, 230V, single phase, 50 Hz complete all as specified and directed by Engr-in-Charge. |
| 18 | Supply and fixing in repairs compressed glass wool 50 mm thick between solar energy collector panel copper tubes frame and aluminium body of panel including securing it on panel by means of necessary adhesives all as directed all as specified and directed by Eng- in -charge. |
| 19 | Supply and fixing in repairs aluminium sheet cover 1mm thick to protect glass wool on solar energy collector panel, fixing with frame of solar panel by means of screws all as directed and recommended by manufacturer. |
| 20 | M&L, for providing rubber foam heavy duty insulation tube over the existing GI tubing of any length at any location in replacement of worn out insulation all as required at site, complete all as specified and directed by Engr-in-Charge. |
| 21 | M&L for GI tubing medium grade, galvanised with all fittings , laid in trenches /on wall/floor etc . ISI mark 25 mm dia bore complete all as specified and directed by Engr-in-Charge. |
| 22 | M&L for GI tubing medium grade, galvanised with all fittings , laid in trenches /on wall/floor etc . ISI mark 20 mm dia bore complete all as specified and directed by Engr-in-Charge. |
| 23 | M&L for GI tubing medium grade, galvanised with all fittings , laid in trenches /on wall/floor etc . ISI mark 15 mm dia bore complete all as specified and directed by Engr-in-Charge. |
| 24 | Supply & Fixing Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 15 mm bore pipes complete all as specified and directed by Engr-in-Charge. |
| 25 | Supply & Fixing Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 20 mm bore pipes complete all as specified and directed by Engr-in-Charge. |
| 26 | M&L for replacement of rubber hose pipe 15mm dia between hot water tank & collector with fitting complete all as specified and directed by Engr-in-Charge |
| 27 | M&L for framed bracket of angle iron / Tees /GI pipe cut and bend to shape ,drilled and screw , including bending & welding angle as necessary GI pipe angle iron frame /stand to make structural stand complete all as specified and directed by engr-in-charge |
| 28 | M&L for painting to angle iron /GI pipe frame / stand after cleaning properly removing dirt ,dust ,rubbing with sand papper and applying two coat of synthetic enamell paint over a coat of red oxide primer ,incl marking of MES no the solar water heater complete all as directed by engr -in- charge |
| 29 | M&L in replacement for Sub Main wiring with two runs of 6sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through medium grade, rigid non-metallic PVC conduit of suitable sizewith all necessary fittings, surface in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly incl sunken boxes for fitting suitable fixturescomplete all as specified and directed by Engineer-in-Charge. |
| 30 | Supply and fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp.complete all as specified and directed by Engineer-in-Charge. |
| 31 | M&L for submain wiring 2 single core PVC insulated FRLS cable 6 Sqmm copper conductor PVC sheathed in and including rigid PVC conduit heavy duty of suitable size incl cutting chiseling of wall and making good to disturbed surface of walls / floor etc with plastering painting etc so as to match with the existing finishes, drawn with 6 Sqmm PVC insulated FRLS copper conductor cable for earth wire fixed with shaddle and connecting to common earth teriminals complete all as specified. |
| 32 | S&F sheet metal enclosure with single door for DBs conforms to IS:8623.III , IP:43 protection, shrouded neutral bar and cement spill protector, 2 way, 240 Volt SPN |
| 33 | S & F MCBs 'B' characteristics, SPN, 240 V, 40 Amp breaking capacity 10 kA , single pole neutral complete all as specified and as directed by Engineer-in-Charge. |
| 34 | Maintenance & Cleaning of Solar Power Plant 7.5 kWp applying greasing and tightening of terminals and cleaning of all solar plates and maintenance of Solar inverter system monthly once and all as specified and as directed by Engineer-in-charge. |
| 35 | Maintenance & Cleaning of Solar Power Plant 25 kWp applying greasing and tightening of terminals and cleaning of all solar plates and maintenance of Solar inverter system monthly once and all as specified and as directed by Engineer-in-charge.. NOTE FOR SER NO 33 & 34 :-Every month submitted to unit generating report in KW. |
| 36 | Note :- The amount of Rs 36355.00 against Schedule of Credit on Srl Page 139 shall be deducted from the total amount quoted against Sch 'A' Please Enable Macros to View BoQ information |