| 1 | M& L for Opening and dismantling of the geyser 25/35/50 ltr capacity and taking out inner tank and glass wool from inside the geyser for descaling and washing with acid to remove the scale, dirt etc if any and re-fixing the same after re-assemble into the geyser and proper filling of glass wool around inner tank complete all as specified and directed. Note :-Glass wool will be paid separately under respective item of Sch 'A' as 'supply only'. |
| 2 | Supply and fixing in replacemnet pack glass wool for geyser capacity 25/35/50 Ltrs complete all as specified and directed. |
| 3 | Supply and fix in replacement outer cover made out of MS sheet suitable for geyser of capacity 25 ltr as per sample duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified. |
| 4 | Supply and fix in replacement inner copper tank made suitable for geyser of capacity 25 ltr complete including necessary driling, brazing work, nut, bolt & washers and testing complete all as specified and directed. |
| 5 | Supply and fix in replacement outer cover made out of MS sheet suitable for geyser of capacity 50 ltr as per sample duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified. |
| 6 | Supply and fix in replacement inner copper tank made suitable for geyser of capacity 50 ltr complete including necessary driling, brazing work, nut, bolt & washers and testing complete all as specified and directed. |
| 7 | Supply and fix in replacement plug top 3 pin 16 Amp 240 voits ISI marked complete all as specified and directed. |
| 8 | Supply and fix in replacement Gun-metal, gate valves of size 15mm dia,with iron wheel head, screwed both ends for iron pipe including removal of old one by cleaning the pipe line all as specified and directed. |
| 9 | Supply and fix in replacement non return valve (gun metal) of size 15mm including removal of old ones complete all as specified and directed. |
| 10 | Supply and fix in replacement fusible plug suitable for 25 Ltrs Cap storage type water heater including provn of necessary GI fittings removal of existing valves complete all as specified and directed. |
| 11 | Supply and fix in replacement indicator lamp assembly complete for water heater (geyser) suitable to work on AC 230 volts supply and to match the existing size any type including disconnecting and removal of old ones. |
| 12 | Supply and fix only MS Nut bolts with split pin as per sample and complete all as specified and directed. |
| 13 | Supply in replacement heating element 2 KW of storage type water heater of compatible type (Triangular /round) or as per existing including making all connections by replacing inter connecting copper conductor cables and removal of old unserviceable elements complete all as specified and directed (ISI Marked). |
| 14 | Supply & fix in replacement thermostat suitable for 25/35/50 ltrs capacity storage type water heater including removal of old unserviceable ones complete all as specified and directed. |
| 15 | Supply and fix in replacement fusible plug suitable for 50Ltrs Cap storage type water heater including provn of necessary GI fittings removal of existing valves complete all as specified and directed. |
| 16 | Supply and fix in replacement geyser apparatus plate/flange assambely (as per approved sample) of ISI marked suitable for 25 ltrs capacity geyser complete all as specified and directed. |
| 17 | Supply and fix in replacement geyser apparatus plate/flange assambely (as per approved sample) of ISI marked suitable for 50 ltrs capacity geyser complete all as specified and directed. |
| 18 | Supply and fix in replacement pressure release valve suitable for 25 /50 ltrs geyser complete all as specified and directed. |
| 19 | Supply and fix in replacement drain plug brass with washer suitable for 25/50 ltrs geysers complete all as specified and directed. |
| 20 | S&F in repair PVC insulated copper conductor 3 core flexible cable of size 1.5 Sq mm complete all as specified and directed. |
| 21 | S & F in replacement of PVC connection pipes inlet and outlet (for hot and cold connection) with brass hexagonal adoptres both side, suitable for 15 mm dia pipe 45 cm long complete all as specified and directed. |
| 22 | S & F in replacement of CP connection pipes inlet and outlet (for hot and cold water ) with brass hexagonal addoptres both side, suitable for 15 mm dia pipe 45 cm long all as specified and directed. |
| 23 | S & F in replacement of PVC connection pipes inlet and outlet (for hot and cold connection) with brass hexagonal adoptres both side, suitable for 15 mm dia pipe 60 cm long all as specified and directed by EIC |
| 24 | S & F in replacement of CP connection pipes inlet and outlet (for hot and cold water ) with brass hexagonal addoptres both side, suitable for 15 mm dia pipe 60 cm long all as specified and directed. |
| 25 | M & L for dismantling of Solar Water Heater of 200/300/500 ltr cap from the site after disconnecting the water connection, electric connection, opening the solar water heater assembly and descalling with hydrochloride solution fixing of Solar water heater assembly, Dismantling solar panel, any Make or type by removing the glass panel carefully and refixing it cleaning dust, cleaning the water collector tubes and alluminium foil including descaling the existing hot water storage tank of any capacity and replacement of rock wool including repair of brass flange, ring nuts, bolts, washers and other connected works preparation of steel surface of water by rubbing with emery paper, painting the surface by spray painting with one coat of synthetic enamel paint of approved make without damaging other parts / wiring of the machine and refixing the same in its original position of electric back up with thermostat, making cold / hot water connection GI pipes as required to make the system functional and connecting up with hot concealed water pipe line for following capacity :- Note :- Spares and accessories will be measured and paid seperately. |
| 26 | S&F in rapair Rotational Moulded polythene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position of capacity 500 Ltrs complete all as specified and directed. |
| 27 | Taking down of old flexible rubber pipe and Supplying and laying of 20 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 28 | S&F ball valve of size 20 mm dia for CPVC pipe with all required fittings complete all as specified and as directed. |
| 29 | S/F in repair GI tubing medium grade with all fittings and fixed to walls/ceiling/floor or laid in trenches of 15 mm bore size all as specified and directed. |
| 30 | All as per item 29 above but for 20 mm bore size. |
| 31 | S/F in repair of hot water piping insulation with two layers of glass wool 25 MM thick covered with chicken wire mesh 24 Gauge and over all covering with aluminium sheet of 28 gauge all as directed. |
| 32 | S/F in repair gun metal or globe or gate valves 20 mm dia with iron wheel scewed both ends all as directed. |
| 33 | S/F in repair Float valve 20 / 25mm dia high pressure with polythene float valve and fly nut complete screwed all as specified. |
| 34 | S/F in repair flat plate collector consisting of transparent cover, riser tube, absober plate, header tube complete suitable for 200 /300 /500 LPD Solar water heater complete all as specified and directed.Make: Vikram Solar/ Adani Solar/ Waaree Solar. |
| 35 | S/F in replacement glass panel rubber beeding of approved quality for solar plate/tubes, complete all as directed. |
| 36 | S/F in replacement heating element of 3 KW, B.S.P threaded with thermostat pocket and metal cap all as per existing one complete as directed. |
| 37 | S/F in replacement of thermostat size 6/11\\" long, suitable for Solar Water Heater of any capacity all as directed. |
| 38 | S&F ball valve of size 20 mm dia, Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed galvanized all required fittings of the complete all as specified and as directed. |
| 39 | M&L in replacemnt for fixing Bib taps, cast copper allloy with crutch or butterfly handle, screw down, screwed for iron pipe or brass ferrule and fixed with 15 mm dia, including proper completion of work all as per specified and directed. |
| 40 | Supply and fix in replacement electric water heater, storage type steel body with SS inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed.. |
| 41 | Supply & Fix sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 A 240 Volts complete all as specified and directed. |
| 42 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting MCBs, DBs etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed. |
| 43 | Taking down old unserviceable distribution board of any size and any capacity including making good the disturbed surface with existing surface complete all as specified and directed by Engr-in-Charge.. Note : (i) Old dismantled wiring and accessaries will be contractors property and credit will be charged against schedule of credit complete all as specified and directed. |
| 44 | Taking out sub main wiring of any type and size including batten/conduit casing capping for renewal/replacement and making good the disturbed surface to the existing surface complete all as specified and directed. |
| 45 | Material & labour for point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, stranded, PVC insulated, unsheathed FRLSH copper conductor cable in and including PVC concealed conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories/fittings, brass screws, washers etc, Sunk Zinc coated pressed steel terminal boxes including all cutting/chases etc in walls, making good to walls, ceiling etc to the disturbed surfaces to match the existing with 3 mm thick plastic laminated sheet top cover including MS box zinc coated sunken box of suitable size of concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core,FRLSH PVC insulated copper stranded conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the followings. |
| 46 | One light/Exhaust fan/ Ceiling fan controlled by one switch 6 Amp, SP, one way 240 volts. |
| 47 | One multi pin socket 6 Amp independent. |
| 48 | One multi pin socket 6 Amp on same board |
| 49 | Ditto, all as per item No 45 hereinbefore but using 2.5 sqmm (nominal area) multistranded copper conductor cable & 2.5 sqmm size PVC insulated FRLSH and unsheathed copper conductor cable FRLSH for earth continuity ( green colour) for one 6 pin socket 15A complete all as specified and directed. |
| 50 | Supply & fixing switch piano flush type, 05/06 Amps single pole , one way 240 volts complete all as specified & directed |
| 51 | Supply & fixing in replacement of socket outlet 5 pin, 05/06 Amps (2 -in-1 Multipurpose) flush type 240 volts complete all as specified & directed. |
| 52 | S&F in replacement socket outlet 2 in 1, 5 pin 5 and 15/16 Amps flush type . |
| 53 | S&Fin replacement switch piano type 250 volts, single pole one way 15 Amps. |
| 54 | S&F in replacement ceiling rose surface bakelite 65 x 50mm, three terminals ISI(Marked) complete all as specified and directed. |
| 55 | S & F in repair fan regulator electronic, step type hum free with polycarbonate body suitable to control speed of fan from 0 to 100% and connecting electrically complete all as specified and directed. |
| 56 | S & F sub main wiring in replacement with two single core PVC insulated unsheathed copper FRLSH cable 4 sqmm stranded conductor and drawing through and including rigid PVC non metalic surface conduit including contineous earth wire PVC insulated unsheathed FRLSH cable 4 sqmm copper multistranded conductor and connected to common earth dolly complete all as specified and directed. |
| 57 | S & F sub main wiring in replacement with two single core PVC insulated unsheathed copper FRLSH cable 6 sqmm stranded conductor and drawing through and including rigid PVC non metalic surface conduit including contineous earth wire PVC insulated unsheathed FRLSH cable 6 sqmm copper multistranded conductor and connected to common earth dolly complete all as specified and directed. |
| 58 | Supply and fixing sheet metal enclosure powder coated single phase double door distribution board SPN 8 ways and neutal 240 V with 200 Amps rated bus bar double door suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces complete all as specified and directed. |
| 59 | All as per item No-55 above but 4 way single door complete all as specified and directed. |
| 60 | Supply and fixing in replacement amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. (i) SP 6 To 32 AMP |
| 61 | Supply and fixing in replacement amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. (i) SPN 32 AMP |
| 62 | M&L earthing in replacement complete with GI earth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI earth wire 4mm dia size up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 20mm dia 5 mtr long GI pipe connected to main control board and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 5 of SSR Part-I 1991. |
| 63 | S&F in repair 20 watts Light emitting Diode (LED) opal diffuser tube light fitting wall mounting , indoor decorative PC LED Batten cover ensures soft and glare free lightening T5 LED battens white /warm, Integrated type, AC 230-240V, 50 hz, with PMMA/PC diffuser, 4' long, easy to install, Efficacy:110 lumen/watt, Minimum 3.5 KV Voltage Serge Protection, Power factor > 0.9, making connections with and including 23/.0076 flexible cord of required length from ceiling rose to connector complete all as specified and directed. |
| 64 | S & F in repair Led Panel round light of 12 W 3000K (white /warm ) Slim, compact, auminum die cast edge lit panel. Recess mounted round fixture with opal diffuser and separate electronic driver Minimum 3.5 KV Voltage Serge Protection, Power factor > 0.9, making connections with and including 23/.0076 flexible cord of required length from ceiling rose to connector complete all as specified and directed. Please Enable Macros to View BoQ information |