| 1 | =B2& \\" BoQ\\" BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE(I) R&D RCI HYDERABAD Name of Work: PERIODICAL MAINTENANCE / REPAIRS OF EOT/HOT CRANES INCLUDING REPLACEMENT OF LT PANELS AND VFD DRIVES AT LSP, SPIC, K-15 CARBON- CARBON AREA UNDER GE(I) R&D RCI, HYDERABAD Contract No: GE(I) RCI/HYD/ OF 2026-2027 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SlNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Basic Rate In Figures To be entered by the Bidder Rs. Ps. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes Total Amount With Taxes Total Amount In Words |
| 2 | S&F FRLS PVC insulated 12core 1.5Sqmm, multistranded copper conductor cable, 1100Volts, ISI marked complete all as specified and directed. |
| 3 | S&F FRLS PVC insulated 4core 16Sqmm, multistranded copper conductor cable, 1100Volts, ISI marked complete all as specified and directed. |
| 4 | S&F FRLS PVC insulated 4core 10Sqmm, multistranded copper conductor cable, 1100Volts, ISI marked complete all as specified and directed. |
| 5 | S&F FRLS PVC insulated 4core 6Sqmm, multistranded copper conductor cable, 1100Volts, ISI marked complete all as specified and directed. |
| 6 | S&F FRLS PVC insulated 4core 4Sqmm, multistranded copper conductor cable, 1100Volts, ISI marked complete all as specified and directed |
| 7 | S&F FRLS PVC insulated 4core 2.5Sqmm, multistranded copper conductor cable, 1100Volts, ISI marked complete all as specified and directed.Make for item No1 to 6 Finolex, Havells, RPG/Gloster |
| 8 | S&F Gear Coupling bush with nuts, bolts and spring washers for LT / CT / Hoist motor coupling of the existing sizes and model 02 to 15 Ton capacity cranes complete all as directed. |
| 9 | S&F Gaer Coupling bush with nuts, bolts and spring washers for LT / CT / Hoist motor coupling of the existing sizes and model for 20 Ton to 30 Ton capacity crane complete all as directed. |
| 10 | S&F Electro magnetic brake/Thruster brake with brake drum of any size complete all as specified and directed. |
| 11 | S&F Brake liner for cranes of 2 to 10 Ton capacity complete all as directed. |
| 12 | S&F Brake liner for cranes of 12 to 20 Ton capacity complete all as directed. |
| 13 | S&F Brake liner for cranes of 25 to 50 Ton capacity complete all as directed. |
| 14 | S&F Thruster break hydraulic oil/ Transformer OilMake: Electro/Servo/Power/Castrol |
| 15 | S&F Gear box oil, grade 320. Make: Electro/Servo/Power/Castrol |
| 16 | S&F the Over Load relay, 0 to 10Amp range, suitable for mounting on Contactor complete all as directed. |
| 17 | S&F the Over Load relay, 12 to 16Amp range, suitable for mounting on Contactor complete all as directed. Make for item No 15 & 20 BCH/L&T/Siemens/C&S/ Schneider |
| 18 | S&F Cadmium compound for wire rope complete all as directed. |
| 19 | S&F Grease compound for wire rope complete all as directed. |
| 20 | S&F, ML 2, 3 pole contactor with AC3 rating of 32Amps with suitable coil voltage complete all as specified and directed.Make: L&T CAT No SS90701 or equivalent in Legrand / Siemens / BCH / Schneider |
| 21 | S&F, ML 4, 3 pole contactor with AC3 rating of 70Amps with suitable coil voltage complete all as specified and directed.Make: L&T CAT No SS90910 or equivalent in Legrand / Siemens / BCH / Schneider |
| 22 | S&F, spare contact kit for ML2 contactor with suitable coil voltage complete all as specified and directed. |
| 23 | S&F, spare contact kit ML3 & ML4 contactor with suitable coil voltage complete all as specified and directed. |
| 24 | S&F, spare coil for ML2 contactor with suitable coil voltage complete all as specified and directed. |
| 25 | S&F, spare coil for ML3 & ML4 contactor with standard coil voltage complete all as specified and directed.Make for item No 22 to 23 BCH/L&T/Siemens/C&S/ Schneider |
| 26 | S&F Limit Switch of any size for Long Travel/Cross Travel complete all as directed.Make: SEIMENS/MACON CONTROLS/BCH |
| 27 | S&F Flexible geared coupling of any size complete all as directed. |
| 28 | S&F standard actuator type Push button switch of any colour complete all as specified and directed.Make: L&T/C&S/BCH/Siemens |
| 29 | S&F Pedestal with bearing for Long Frame/Cross Travel Shaft complete all as directed. |
| 30 | Removing the burnt out control and power wiring from crane panel board and providing and fixing new wiring with suitable size copper conductor cable including replacement of damage/burnt out connectors, fuse holders, cable lugs, cables glands etc., complete all as specified and directed. |
| 31 | Dismantling of Long travel assembly complete from all electrical connections, repairs to damaged long travel system by replacing with new gear and coupling, pedestal and modifying motor and gear box, platform by cutting, welding and reassembling the long travel assembly, reconnecting electrical connections, testing and commissioning of crane for smooth operation of long travel system for 20/25 Ton EOT crane complete all as directed. |
| 32 | Same as item No 30 above but for 15 to 30 Ton crane |
| 33 | Dismantling of cross travel assembly complete from all electrical connections, repairs to damaged long travel system by replacing with new gear and coupling, pedestal and modifying motor and gear box, platform by cutting, welding and reassembling the long travel assembly, reconnecting electrical connections, testing and commissioning of crane for smooth operation of long travel system for 2 to 10 Ton EOT crane |
| 34 | Same as item No 32 above but for 15 to 30 Ton crane |
| 35 | Dismantling of Main hoist assembly complete from all electrical connections, repairs to hoist by replacing with new gear and coupling, pedestal and modifying motor and gear box, platform by cutting, welding and reconnecting electrical connections, testing and commissioning of crane for smooth operation of long travel system for 2 to 10 Ton EOT crane |
| 36 | Same as item No 34 above but for 15 to 30 Ton crane |
| 37 | Disconnecting electrical connections removing the unserviceable burnt out Power drive of Cross Travel/Long Travel of 3/5/10/7.5/12 Ton capacity crane, S&F and fix new cross travel/long travel power Variable Frequency Drive of model Acs 380 series 1 HP, 0.75 KW make ABB OR equivalent in Siemens ,Yakhsawa, L&T, CG, including programming by OEM Engineer and testing complete all as specified and directed. |
| 38 | All as per item No 36 above but for 20/25/30/50 Ton capacity crane power Variable Frequency Drive of model Acs 380 series 2 HP, 1.5 KW . |
| 39 | Opening of electrical connection of 2/3/5 Ton capacity crane and removing of damaged Cross Travel/Long Travel electric drive and taking to authorized servicing agency of Siemens, opening of electrical drive and replacing the burnt out phase cards, power diodes, unserviceable parts i.e. capacitors, integrated circuits, resistors, electronic transformer and reassembling the complete electric drive and bringing back to site after repairing and refixing electrical drive, connecting electrical drive and commissioning complete all as directed |
| 40 | All as per item No 38 above but for 7.5/10 Ton capacity crane |
| 41 | All as per item No 38 above but for 12/15/20 Ton capacity crane |
| 42 | All as per item No 38 above but for 25/30/50 Ton capacity crane |
| 43 | Removing Induction motor of 1.5/2 HP capacity of cranes from foundation after opening foundation nut bolts, coupling and disconnecting, dismantling and taking down the Hoist/CT/LT motor from the installed position, opening of motor, servicing, greasing, insulating, varnishing and drying including replacement of damaged/worn out unserviceable bearings and refixing in the original position, connecting the electrical connections and testing complete all as directed. Make of Bearing: SKF/NBC/TATA |
| 44 | All as per item No 42 above but for 3.5/7.5HP capacity motor |
| 45 | All as per item No 42 above but for 8/10 HP capacity motor |
| 46 | All as per item No. 42 above but for more than 10HP and upto 25HP capacity motor |
| 47 | Dismantling of Long Travel gear box/Cross Travel/Hoist gear box of 20/25/30 Ton capacity cranes by opening long travel shaft and transporting to local workshop opening of gear box, replacement of broken damaged brass gears 06 No of different sizes, replacement of bearings 02 No, Oil-seal, 'O' Rings, Thrust washer, Retaining spring, Lock washers, Gasket and reassembling of gear box completely after repairing returning back to site, refixing in the original position, and testing for smooth functioning complete all directed. |
| 48 | All as per item No 46 above but for 10/15 Ton capacity crane. |
| 49 | All as per item No 46 above but for 2/3/5 Ton capacity crane. |
| 50 | Dismantling of Thrust Brake and carrying out thorough cleaning of inner surfaces and it's motor, draining out of the brake oil from its chamber and storing the same in a container, cleaning the bearings, replacing the worn out bearings and filling back the brake oil, refixing the thrust brake assembly complete all as directed. |
| 51 | S&F in repairs 160Amp HRC fuse DIN type carrier male female type with HRC fuses complete all as directed. |
| 52 | All as per item No 50 above but 100Amp capacity. |
| 53 | All as per item No 50 above but 63Amp capacity. |
| 54 | All as per item No 50 above but 32Amp capacity.Make for item No 50 to 53: Standard / L&T/ Havells / C&S / Schneider. |
| 55 | Disconnecting electrical connections, cleaning each resistance box, removing the burnt out resistance and S&F and fix the new resistance in existing position with LT, CT and Hoist complete of cranes complete all as directed. |
| 56 | Removing the unserviceable Step down transformer, S&F and fix new step down transformer 1.5 KVA, 440/220/110 Volts capacity complete all as per specified and directed. |
| 57 | Conducting Load and Deflection test to EOT/HOT crane of 2/3/5 Ton capacity and submitting test report complete all as directed.Notes: 1. Load for testing shall be provided/arranged by the contractor from out side under his own arrangement including necessary transportation and all other costs.2. Crane testing shall be carried out by the authorized Inspector as per Factories ACT in the presence of user and safety officer. |
| 58 | All as per item No 56 above but for 7.5/10/12 Ton capacity crane. |
| 59 | All as per item No 56 above but for 15/20/25 Ton capacity crane. |
| 60 | All as per item No 56 above but for 30/ 50 Ton capacity crane. |
| 61 | S&F Carbon rubber bush for slip ring motor of the existing model and size complete all as directed. |
| 62 | S&F Steel wire rope for main hoist of size 10mm complete as specified and directed |
| 63 | S&F Steel wire rope for main hoist of size 12mm complete as specified and directed |
| 64 | S&F Steel wire rope for main hoist of size 16mm complete as specified and directed |
| 65 | S&F Steel wire rope for main hoist of size 20mm complete as specified and directed |
| 66 | S&F Steel wire rope for main hoist of size 25mm complete as specified and directed |
| 67 | Disconnecting electrical connections removing the unserviceable burnt out Power drive of Main Hoist of 2 To 7.5 Ton capacity crane, S&F and fix new Main Hoist Variable Frequency Drive of model Acs 380 series (5 to 10HP, 3.5 to 7.5 KW) make ABB OR equivalent in Yasakawa, Siemens, L&T, CG, including programming by OEM Engineer and testing complete all as specified and directed. |
| 68 | Disconnecting electrical connections removing the unserviceable burnt out Power drive of Main Hoist of 10 To 20 Ton capacity crane, S&F and fix new Main Hoist Variable Frequency Drive of model Acs 380 series (15 to 20 HP, 11 to 15 KW) make ABB OR equivalent in Yasakawa, Siemens, L&T, CG, including programming by OEM Engineer and testing complete all as specified and directed. |
| 69 | Disconnecting electrical connections removing the unserviceable burnt out Power drive of Main Hoist of 25 To 30 Ton capacity crane, S&F and fix new Main Hoist Variable Frequency Drive of model Acs 380 series (25 to 30 HP, 18.5 to 22.5 KW) make ABB OR equivalent in Yasakawa, Siemens, L&T, CG, including programming by OEM Engineer and testing complete all as specified and directed. |
| 70 | Dismantling the old cable track assembley and S & F new Cable track assembly for carnes at various capacityies including suitable support chain complete all as specified and directed. |
| 71 | Dismantling the old DSL track assembley and S & F new DSL track assembly for carnes at various capacityies complete all as specified and directed. |
| 72 | S&F in repairs, SV Highbay light to LED High bay light, energy saving, enviorment friendly & robust highbay LED with PDC housing suitable for ceiling ( Surface type/Suspended type) mouting with system efficacy upto 150 Im/watt, 120watt including necessary connection complete all as specified and directed.Note: Equipment and tools required for fitting of lights is arranged by contractor.Make: Havells or equivalent in Crompton/C&S/ Philips |
| 73 | Dismantling of cross trave/long travel/hoist assembly gear boxes/mechanical parts and reapairing of girders/wheels by fabrication work at workshop also do necessary wheel diagnosis requires at site for all capacity cranes all as directed and specified. Note: Cost of Dismantling , transportation, repairing, refixing at site and replacement of any unserviceable parts included in quoted rate. |
| 74 | Dismantling the old Gear Box assembley in complete and S & F new Gear Box assembley assembly for carnes of 8 to 12 TON capacities for long Travel complete all as specified and directed. Make : Nu Teck /JS Gear/SANTRAM ENGG |
| 75 | Dismantling the old Gear Box assembley in complete and S & F new Gear Box assembley assembly for carnes of 8 to 12 TON capacities for Cross Travel complete all as specified and directed. Make : Nu Teck /JS Gear/SANTRAM ENGG |
| 76 | Dismantling the old Gear Box assembley in complete and S & F new Gear Box assembley assembly for carnes of 8 to 12 TON capacities for Hoist complete all as specified and directed. Make : Nu Teck /JS Gear/SANTRAM ENGG Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |