| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GARRISON ENGINEER (AF) BANGALORE NAME OF WORK : REPAIR/REPLACEMENT OF FEEDER PILLAR BOX, BUSBAR, LT PANEL, EARTHING AND REPAIR/REPLACEMENT TO SECURITY LIGHTS, STREET LIGHTS, GATE LIGHTS, HIGH MAST AND CONTROLLING PANELS AT OMQ AND GOLF AREAS AT HQTC BANGALORE. CA NO: GE(AF)/B/ OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item of Work Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT (in Words) |
| 2 | COMMON ITEMS APPLICABLE FOR 'JOB A' & 'JOB B' |
| 3 | Excavation in trenches not exc. 1.5m wide and not exc. 1.5 deep and getting out in soft/loose soil complete all as specified and directed. |
| 4 | Returning, filling in,including spreading, levelling ,watering and well ramming in layers not exc 25cm thick in soft/loose soil complete all as specified and directed. |
| 5 | Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. |
| 6 | M&L for sand cushioning to under ground cable with locally available dry sand for protection of cable 8cm thick before laying of cable and 15 cm thick after laying and stretching the cable below the bricks/PCC cover ,punning of sand using suitable T&P as per site requirement complete all as specified and directed.Note- Punned thickness of sand 18 cm shall be considered for measurement purpose. |
| 7 | Supplying and laying un-reinforced precast concrets cable cover class LV, Type 1, flat, size 250x150x40 mm complete all as specified and directed. |
| 8 | Taking out unserviceable cable any type/size from trenches,pole, road,duct etc including necessary joints,U/S fittings and pipes etc complete all as specified and directed. |
| 9 | Supply and laying in trenches /laid in floor/duct/drawn through conduit XLPE insulated,screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable 1100V grade with aluminum conductor of cross sectional area 10 sqmm 2 core and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified and directed. |
| 10 | All as per Sl Item no 7.00 here-in-before but of size 10 sqmm 4 core. |
| 11 | S&F in replacement MCCB, 4 poles 415 Volts, 63 Amps, 16 kA, 50 Hz, AC, fixed thermal and fixed magnetic type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed.SL NO 18 OF JOB A + SL NO 26 OF JOB B |
| 12 | Disconnecting and taking out old rusted pipe and material and labour for 50 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including Flat Iron clamps=02 Nos of size 50x6mm, with nut bolt and washers complete all as specified & directed. |
| 13 | ITEMS APPLICABLE FOR 'JOB A' |
| 14 | M&L Plain cement concrete 1:2:4 type B1(using 20mm graded crushed stone aggregate) as in benching,coping including weathering slightly rounded or chamfered angles or as per site requirement with necessary plastering work complete all as specified and directed. |
| 15 | Supply and laying in trenches /laid in floor/duct/drawn through conduit XLPE insulated,screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable 1100V grade with aluminum conductor of cross sectional area 16 sqmm 3 core and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified and directed. |
| 16 | All as per Sl Item no 13.00 here-in-before but of size 25 sqmm 4 core. |
| 17 | All as per Sl Item no 13.00 here-in-before but of size 35 sqmm 3.5core. |
| 18 | All as per Sl Item no 13.00 here-in-before but of size 50 sqmm 3.5core. |
| 19 | All as per Sl Item no 13.00 here-in-before but of size 70 sqmm 3.5core. |
| 20 | All as perSl Item no 13.00 here-in-before but of size 95 sqmm 3.5core. |
| 21 | All as perSl Item no 13.00 here-in-before but of size 120 sqmm 3.5core. |
| 22 | Dismantling of unserviceable/damaged MCB/MCCB of any type/size and removal from site complete all as specified and directed. |
| 23 | S&F in replacement MCCB, 4 poles 415 Volts, 100 Amps, 16 kA, 50 Hz, AC, fixed thermal and fixed magnetic type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed. |
| 24 | S&F in replacement MCCB, 4 poles 415 Volts, 200 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed. |
| 25 | S&F in replacement MCCB, 4 poles 415 Volts, 250 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed. |
| 26 | S&F in replacement MCCB, 4 poles 415 Volts, 400 Amps, 50 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed. |
| 27 | S&F in replacement MCCB, 4 poles 415 Volts, 500 Amps, 50 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed. |
| 28 | S&F in replacement MCCB, 4 poles 415 Volts, 630 Amps, 50 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed. |
| 29 | S&F in replacement MCCB, 3 poles 415 Volts, 200 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed. |
| 30 | S&F in replacement MCCB, 3 poles 415 Volts, 250 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed. |
| 31 | S&F in replacement MCB TPN 63A \\"C\\" curve, 415V,10KA 50 Hz, AC, adjustable type in the existing LT panel board/sheet metal enclosure including connecting up incoming/out going cables connection with suitable lugs and testing complete all as specified & directed. |
| 32 | Dismantling and taking out old existing unserviceable/damaged/burnt change over switch 4 pole of capacity 63 Amp to 400 Amp 50 Hz 415 Volt any make,any capacity complete all as specified & directed. |
| 33 | S&F in replacement on load Changeover switch 415 Volt in sheet steel enclosure 4 pole of capacity 63 Amp including connecting up incoming/out going cables connection with suitable lugs and testing complete all as specified & directed. |
| 34 | S&F in replacement on load Changeover switch 415 Volt in sheet steel enclosure 4 pole of capacity 100 Amp including connecting up incoming/out going cables connection with suitable lugs and testing complete all as specified & directed. |
| 35 | S&F in replacement on load Changeover switch 415 Volt in sheet steel enclosure 4 pole of capacity 200 Amp including connecting up incoming/out going cables connection with suitable lugs and testing complete all as specified & directed |
| 36 | S&F in replacement on load Changeover switch 415 Volt in sheet steel enclosure 4 pole of capacity 400 Amp including connecting up incoming/out going cables connection with suitable lugs and testing complete all as specified & directed. |
| 37 | M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4mpa working pressure complete all as specified & directed. |
| 38 | Disconnecting and taking out old rusted pipe and S&F 25 mm dia GI tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including Flat Iron clamps=02 Nos of size 25x3mm, with nut bolt and washers complete all as specified & directed. |
| 39 | M&L for Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron strip of size 32 x 6 mm as earth lead up to test point with suitable size GI nuts/bolts, washers,check nut and brazed properly up to main board,LT panel etc and adequate quantity of charcoal and salt 15 cm around the earth plate including earth pit in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregates,40mm thick precast RCC cover in 1:2:4 reinforced with 8mm dia TMT bars 3 Nos both way including CI cover 10 mm thick with hinged and frame of angle iron 25x25x6mm with 6mm dia MS bar handle made to shape, excavation and earth work in any type of soil and including medium grade GI watering pipe 20mm bore with funnel and wire mesh and medium grade GI protection pipe 40mm bore up to main board complete all as shown in electrical plate no 3 of MES schedule Part-I , connected to earthing testing point and testing on completion complete all as specified and directed. Note: (i) The unit rate includes 40 mm dia GI pipe up to 7.5m for protection of earth lead. (ii) The unit rate includesGI main earthing lead/strip of size 32x6 mm from earth electrode to test point up to 7.5 meter (iii) In case measured value of earth resistance of each earthing is recorded more than 3 ohms then the earthing shall be re done by the contractor without any extra cost to the Govt till desired result is obtained (iv) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge / JE E/M and proper record shall be maintained duly signed by all concerned. (v) Earth resistance tester shall be provided by the contractor. |
| 40 | S&F GI strip 25X4 mm with saddles and fixing screws on poreceling insulator/ spacer fixed at every 1 mtr length as lightening conductor on roof/wall of explosive building/ connect to LT panel or main DB and joining the same with existing earth test point complete all as specified & directed. |
| 41 | M&L for Earthing complete with copper earth plate of size 600x600x3.15mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to copper strip of size 20x3 mm as earth lead up to test point with suitable size copper coating nuts/bolts, washers,check nut and brazed properly up to main board,LT panel etc and adequate quantity of charcoal and salt 15 cm around the earth plate including earth pit in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregates,40mm thick precast RCC cover in 1:2:4 reinforced with 8mm dia TMT bars 3 Nos both way including CI cover 10 mm thick with hinged and frame of angle iron 25x25x6mm with 6mm dia MS bar handle made to shape, excavation and earth work in any type of soil and including medium grade GI watering pipe 20mm bore with funnel and wire mesh and medium grade GI earth wire protection pipe 40mm bore up to main board complete all as shown in electrical plate no 3 of MES schedule Part-I , connected to earthing testing point and testing on completion complete all as specified and directed. Note: (i) The unit rate includes 40 mm dia GI pipe up to 7.5m for protection of earth lead. (ii) The unit rate includes copper main earthing lead/strip of size 20x3 mm from earth electrode to test point up to 7.5 meter (iii) In case measured value of earth resistance of each earthing is recorded more than 2 ohms then the earthing shall be re done by the contractor without any extra cost to the Govt till desired result is obtained .(iv) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge / JE E/M and proper record shall be maintained duly signed by all concerned. (v) Earth resistance tester shall be provided by the contractor. |
| 42 | S&F copper strip 20mm X 3mm with saddles and fixing screws on poreceling insulator/ spacer fixed at every 1 mtr length as lightening conductor on roof/wall of explosive building/ connect to LT panel or main DB and joining the same with existing earth test point complete all as specified & directed. |
| 43 | S&F straight through joints heat shrink type for XLPE insulated,screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable 1100V grade with aluminum conductor cables of size 6 sqmm to 16 sqmm by excavating earth, identifying the fault, making proper joint of cable,testing of cable after rectification & returning soil back to earth complete all as specified & directed. |
| 44 | S&F straight through joints heat shrink type for XLPE insulated,screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable 1100V grade with aluminum conductor cables of size 25 sqmm to 50 sqmm by excavating earth, identifying the fault, making proper joint of cable,testing of cable after rectification & returning soil back to earth complete all as specified & directed. |
| 45 | S&F straight through joints heat shrink type for XLPE insulated,screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable 1100V grade with aluminum conductor cables of size 70 sqmm to 120 sqmm by excavating earth, identifying the fault, making proper joint of cable,testing of cable after rectification & returning soil back to earth complete all as specified & directed. |
| 46 | M&L for scrapping and removing of existing paint,dust,rust by emery paper or other means and preparation of smooth surface for painting and painting with two coats of high quality synthetic enamel paint with approved colour on any size ,any type and any capacity feeder pillar box, LT panel including writting of incoming and outgoing location of all cables on LT panels and feder pillar box with high quality synthetic enamel paint red colour complete all as specified & directed. |
| 47 | M&L for servicing, cleaning, dusting both side of Indoor/Outdoor LT Panel/ feeder pillar box of any size ,any type any capacity incl carrying out necessary repair to the existing panel/ feeder pillar box , replacing the unserviceable spares parts,tightening cable connections,welding the damage doors, repair/replacement of door handles/locks,hinges,glands,nut ,bolts/lugs of cable/MCCBs of any type any size,any number replacing the old rusted frames,and removing vegitation , debries around panel upto 2 mtr radius also connecting up the all incoming/outgoing cables complete all as specified & directed. Notes :- Spares like voltmeter,ammeter,selector switches,indicator lamps, CTs etc shall be measured and paid seperately under respective item of schedule. |
| 48 | S&F in replacement Digital type ammeter of range 0-600 Amp Accuracy Class 1.0 of LT panel with all connected accessories including connecting up and testing complete all as specified & directed. |
| 49 | S&F in replacement Digital type Voltmeter of range 0-500 Volts Accuracy Class 1.0 of LT panel with all connected accessories including connecting up and testing complete all as specified & directed. |
| 50 | S&F in replacement LED indicator lamp 240 V set of three (R,Y,B) of LT panel with all connected accessories including connecting up and testing complete all as specified & directed. |
| 51 | S&F in replacement of Rotatory selector switch 3/4 way 10A of LT panel including connection and testing complete all as specified & directed. |
| 52 | S&F in replacement of Curent transformer (CT) 300/5A , accuracy class 1.0 , burden 10 VA , resin cast wound type of LT panel including connecting up and testing complete all as specified & directed. |
| 53 | S&F in replacement of Curent transformer (CT) 250/5A , accuracy class 1.0 , burden 10 VA, resin cast wound type of LT panel including connecting up and testing complete all as specified & directed. |
| 54 | S&F in replacement of Curent transformer 100/5A , accuracy class 1.0 , burden 5 VA , resin cast wound type of LT panel including connecting up and testing complete all as specified & directed. |
| 55 | S&F in replacement of Danger notice plates, made out of 1.6mm thick MS sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT 20X15 cm size,complete all as specified & directed. |
| 56 | S&F in replacement 3 pole Power contactor MNX type AC, 415V, 50Hz 3 MNX 95 Contactor 2 NO+ 2 NC including taking down unserviceable and connecting up ,testing complete all as specified & directed. Make - Lauritz Knudsen CS94136 (Former L&T) or Techno-commercially equivalent in Legrand,Indo-Asian or Schneider |
| 57 | Excavation any type soil up to 60 cm depth and 45 cm width to find the fault of LT UG cable any size any place at HQTC area, taking out carefully cable cover, locate the pin point fault of cable,repairing the cable using cable jointing kits and by adding extra LT cable if required at site, testing and relaying the cable cover and returning, filling in,including spreading, levelling ,watering and well ramming including removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified & directed. Note- LT joints / LT cable(if reqd) shall be measured & paid separately under respective item of schedule. |
| 58 | ITEMS APPLICABLE FOR 'JOB B' Notes applicable for JOB B:- (i) One electrician and one helper with suitable size bamboo ladder,safety belt and T&P shall report to JE E/M/ Engr-in-Charge at 0930 hrs at AGE E/M sub Division and upto 1730 hrs on all working days including sunday and holidays w.e.f date of commencement to date of completion of contract. (ii) Day to day complaints of street light,security light,gate light,garden light,area light of any type,any capacity in OMQ and Golf area HQTC shall be given to electrician by the JE E/M/ Engr-in-charge.(iii) No extra payment shall be given to the contractor for the provision of one electrician and one helper.(iii) A penalty of rupees 600/- for electrician and 400/- for helper per day shall be deducted from contractor dues on day of absence. |
| 59 | Taking down existing defective/unservicable street light fittings/security light fittings/Flood light fittings of any capacity,any description,any wattage, any type and in any position from poles/pipes/ walls of buildings of any height complete after disconnecting the electrical connection replacement of un-serviceable/damaged/ broken spare parts/ brackets etc, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in same position, connecting to electric supply and its testing on installation complete all as specified and directed. |
| 60 | Taking down existing defective/unservicable post top lanterns/Gate lights /Garden lights fitting of any capacity,any description,any wattage, any type and in any position fixed at a height not more than 4 mtr from ground level complete after disconnecting the electrical connection replacement of un-serviceable/damaged/ broken spare parts,accessories etc, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in same position, connecting to electric supply and its testing on installation complete all as specified and directed. |
| 61 | Lowering of and lifting of carriage of high mast lights fitting with wire rope motorised or manually existing defective/unservicable high mast lights fittings of any capacity,any description,any wattage, any type,any position and any height after disconnecting the electrical connection replacement of un-serviceable/damaged/ broken spare parts/ accessories etc,including servicing of High mast of any height and description , opening the mechanical hoisting / lowering assy , steel wire bobbin , replacing the unservieable meshing gear, easying the steel rope movements, checking the locking mechanism , replacing of oil ,greasing complete and checking for smoothing operation of the mast, re-assembling the high mast lights fittings and making the high mast lights fittings serviceable, fixing the fittings in same position, connecting to electric supply and its testing on installation complete all as specified and directed. |
| 62 | S&F high energy efficent constant current electronic driver suitable for LED street light fitting 35 Watts, LED luminaires 240 Volt ,50Hz, AC single phase complete all as specified and directed. |
| 63 | S&F high energy efficent constant current electronic driver suitable for LED street light fitting 45 Watts, LED luminaires 240 Volt ,50Hz, AC single phase complete all as specified and directed. |
| 64 | S&F high energy efficent constant current electronic driver suitable for LED street light fitting 90 Watts, LED luminaires 240 Volt ,50Hz, AC single phase complete all as specified and directed. |
| 65 | S&F high energy efficent constant current electronic driver suitable for LED street light fitting 100 Watts, LED luminaires 240 Volt ,50Hz, AC single phase complete all as specified and directed. |
| 66 | S&F high energy efficent constant current electronic driver suitable for LED Flood light fitting 30 Watts, LED luminaires 240 Volt ,50Hz, AC single phase complete all as specified and directed. |
| 67 | S&F high energy efficent constant current electronic driver suitable for LED Flood light fitting 50 Watts, LED luminaires 240 Volt ,50Hz, AC single phase complete all as specified and directed, |
| 68 | S&F high energy efficent constant current electronic driver suitable for LED Flood light fitting 60 Watts, LED luminaires 240 Volt ,50Hz, AC single phase complete all as specified and directed. |
| 69 | S&F high energy efficent constant current electronic driver 120 watt suitable for Golf area LED Flood light fitting 2x100 Watts, LED luminaires 240 Volt ,50Hz, AC single phase complete all as specified and directed.Make : Polycab Cat Ref PCLD C5 120W-01 or Techno-commercially equivalent in Philips/Bajaj/Havells |
| 70 | S&F high energy efficent constant current electronic driver suitable for LED Flood light fitting 200Watts, LED luminaires 240 Volt ,50Hz, AC single phase complete all as specified and directed. |
| 71 | M&L for opening the LED street light/Flood light fittings of capacity 30 watts to 60 watts ,any type and in any position,taking out the LED motherbaord,checking the power LED's, replacing the unserviceable motherboard,electronic driver, power LED's and soldering or any item as per requirement and making the light fittings serviceable in any way and fixing the fittings in same position including testing, complete all as specified and directed. |
| 72 | M&L for opening the LED street light/Flood light fittings of capacity 90 watts to 200 watts ,any type and in any position,taking out the LED motherbaord,checking the power LED's, replacing the unserviceable motherboard,electronic driver, power LED's and soldering or any item as per requirement and making the light fittings serviceable in any way and fixing the fittings in same position including testing, complete all as specified and directed. |
| 73 | Dismantling the three phase motor upto 5 HP,440 Volt ,50Hz, AC of High mast lights fittings and taking out to workshop for re-winding,removing the burntout windings, re-winding the same with super enamelled copper wire of existing guage,varnishing and oven drying , and replacing any item as per requirement ,assembling the motor including testing, making the motor serviceable in any way and fixing the motor in same position complete all as specified and directed. |
| 74 | Disconnecting and taking out old rusted/ unserviceable light fitting’s bracket incl FI clamps of any description and in any position and S&F brackets made out of 50 mm dia light grade GI pipe 1.50 mtr long bent to shape and size as per site requirement for fixing of street light fitting on poles/ walls including Flat Iron clamps=02 Nos of size 30x5mm made to shape incl nuts,bolts & washers complete all as specified and directed. |
| 75 | Disconnecting and taking out old rusted pipe and M&L for 40 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including Flat Iron clamps=02 Nos of size 30x5mm, with nut bolt and washers complete all as specified & directed. |
| 76 | Disconnecting and taking out old existing unserviceable PVC cable loop box and S&F with pole/wall/pillar PVC cable loop box, size not less than 200 mm x 140 mm x 95 mm, out door type, IP 65 including 4 Nos aluminum bus bar of size 100mmx5mm mounted on porcelain insulators with one MCB SP 6 amps 230 volts connected to street light/gate fitting sub main wire and using FI clamps of size 20mm x 3 mm for fixing of PVC cable loop box with pole,including nuts,bolts & washers and connecting the cables to bus bars with using suitable size GI nut, bolts and washers and aluminum lugs etc and complete all as specified & directed. |
| 77 | Disconnecting and taking out old existing unserviceable PVC cable loop box and S&F with pole PVC cable loop box, size not less than 145 mm x 145 mm x 95 mm, out door type, IP 65 including porcelain insulated connectors for incoming and outgoing 4 core cables with one MCB SP 6 amps 230 volts connected to street light fitting sub main wire and using FI clamps of size 20mm x3 mm for fixing of PVC cable loop box with pole,including nuts,bolts & washers and connecting the cables to connectors with using suitable size GI nut, bolts and washers and aluminum lugs etc and complete all as specified & directed. |
| 78 | M&L for sub main wiring from street light fitting to junction box with two single core PVC insulated cable with copper conductor multistranded 1100 volts grade 1.5 sqmm in and including heavy grade PVC conduit and its accessories with fixing arrangements on pole surface, wall, ceiling etc including 1.5 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC conduit and two runs of copper conductor shall be together taken as one length for measuring unit length. |
| 79 | S&F single core PVC insulated,unsheathed, FRLS multistranded copper conductor 1100 volts grade cable of size 2.5 sqmm , fixed in repairs, complete all as specified and directed by Engineer-in-Charge. |
| 80 | S&F MCB SP, 6-32A, 240V,50Hz ,10kA, 'B' type, for street light fittings complete all as specified and directed. |
| 81 | S&F MCB SPN 32A, 240V,50Hz ,10kA, 'B' type,suitable for existing timer control board complete all as specified and directed. |
| 82 | S&F MCB TPN, 63A , 415V,50Hz ,10kA, 'B' type,suitable for existing timer control board complete all as specified and directed. |
| 83 | S&F 3 pole Power Contactors 415 volt 50 Hz ML3 type 40 Amps AC3 rating with 2 NO +2NC Aux contacts, fixed in repairs,including taking out old existing unserviceable complete all as specified & directed.Make : Lauritz Knudsen (Former L&T) Cat No. SS 90721 or Techno-commercially equivalent in Legrand,Indo-Asian or Schneider |
| 84 | S&F 3 pole Power Contactors 415 volt 50 Hz ML 4 type 70 Amps AC3 rating with 2 NO +2NC Aux contacts, fixed in repairs,including taking out old existing unserviceable complete all as specified & directed.Make : Lauritz Knudsen (Former L&T) Cat No. SS 90910 Techno-commercially equivalent in Legrand,Indo-Asian or Schneider |
| 85 | S&F Digital Multi function time switch with programmable fuction with battery backup and current carring capacity 16 Amps with 1 changeover including takingout the unserviceable time switch, complete all as specified & directed. Make : Lauritz Knudsen (Former L&T) 67DDT0 or Techno-commercially equivalent in Legrand,Indo-Asian or Schneider |
| 86 | S&F Street light panel box 32 Amps , 3 pole, 230 volts with contactor, Digital time switch ,24 hours timer , MCB TPN etc, including takingout the unserviceable street light panel box , complete all as specified & directed. Make : Indo Asian TL032DBO or Techno-commercially equivalent in L&T or Schneider. |
| 87 | S&F LED flood light fitting 30 watts,240 Volt, single phase, AC, outdoor type,aluminium pressure die-cast housing with IP66 protection with 4 Kv in-built surge protection complete with driver,motherboard and LED including taking down unserviceable fitting, connecting and testing complete all as specified & directed. Make : Bajaj BJFL 30W LED or Techno-commercially equivalent in Havells/Philips/Wipro. |
| 88 | S&F LED flood light fitting 50 watts,240 Volt, single phase, AC, outdoor type,aluminium pressure die-cast housing with IP66 protection with 4 Kv in-built surge protection complete with driver,motherboard and LED including taking down unserviceable fitting, connecting and testing complete all as specified & directed. Make: Bajaj BJFL 50W LED or Techno-commercially equivalent in Havells/Philips/Wipro. |
| 89 | S&F LED flood light fitting 60 watts,240 Volt, single phase, AC, outdoor type,aluminium pressure die-cast housing with IP66 protection with 4 Kv in-built surge protection complete with driver,motherboard and LED including taking down unserviceable fitting, connecting and testing complete all as specified & directed.Make:Havells JETAALBAFLOODLIGHT60W or Techno-commercially equivalent in Philips/Wipro. |
| 90 | S&F LED flood light fitting 100 watts,240 Volt, single phase, AC, outdoor type, with pressure die-cast housing, toughened glass with IP66 protection with 4 Kv in-built and 10 Kv external surge protection complete with driver,motherboard and LED including taking down unserviceable fitting,connecting and testing complete all as specified & directed. Make: Bajaj PRAZE F 120L WH NB-A5 TG SD or Techno-commercially equivalent in Havells/Philips/Wipro. |
| 91 | S&F LED flood light fitting 200 watts,240 Volt, single phase, AC, outdoor type, with superior polycarbonate optics pressure die-cast housing, with IP66 protection with 4 Kv in-built and 10 Kv external surge protection complete with driver,motherboard and LED including taking down unserviceable fitting,connecting and testing complete all as specified & directed.Make: Bajaj GLEAM F 220L WH SY PC SD V2 or Techno-commercially equivalent in Havells/Philips/Wipro. |
| 92 | S&F LED street light fitting 35 watts,240 Volt, single phase, AC, outdoor type with pressure die-cast housing with IP66 protection,high performance polycarbonate optics, 4 Kv in-built surge protection with top opening driver cover complete with driver,motherboard and LED including taking down unserviceable fitting,connecting and testing complete all as specified & directed.Make:- Bajaj ENXT P 42L WH PO PC SD MT or Techno-commercially equivalent in Havells/Philips/Wipro. |
| 93 | S&F LED street light fitting 45 watts,240 Volt, single phase, AC, outdoor type with pressure die-cast housing with IP66 protection,high performance polycarbonate optics, 4 Kv in-built surge protection with top opening driver cover complete with driver,motherboard and LED including taking down unserviceable fitting,connecting and testing complete all as specified & directed.Make Bajaj ENXT P 54L WH PO PC SD MT or Techno-commercially equivalent equivalent in Havells/Philips/Wipro. |
| 94 | S&F LED street light fitting 90 watts,240 Volt, single phase, AC, outdoor type with pressure die-cast housing, toughened glass with IP66 protection with 4 Kv in-built and 10 Kv external surge protection complete with driver,motherboard and LED including taking down unserviceable fitting,connecting and testing complete all as specified & directed. Make: Bajaj ZELA P 108 L WH PO TG SD or Techno-commercially equivalent in Havells/Philips/Wipro. |
| 95 | S&F LED street light fitting 100 watts,240 Volt, single phase, AC, outdoor type with pressure die-cast housing, toughened glass with IP66 protection with 4 Kv in-built and 10 Kv external surge protection complete with driver,motherboard and LED including taking down unserviceable fitting,connecting and testing complete all as specified & directed.Make : Bajaj ZELA P 120 L WH PO TG SD or Techno-commercially equivalent in Havells/Philips/Wipro/CG. |
| 96 | S&F LED post-top light fitting 25 watts made in die-cast aluminium bottom housing and spun aluminium top reflector with decorative clear acrylic diffuser and IP 65 protection with 25 watt LED bulb including taking down unserviceable fitting, complete all as specified & directed. Make : Bajaj BGCTN 25 W LED WH or Techno-commercially equivalent make of Havells/Philips/Wipro/CG. |
| 97 | S&F LED post-top light fitting 25 watts made in spherical shape polycarbonate opal and clear diffuser with IP 65/66 protection with 25 watt LED bulb including taking down unserviceable fitting, complete all as specified & directed.Make: Bajaj BLPTSP 25 W WW LED or Techno-commercially equivalent make of Havells/Philips/Wipro/CG. |
| 98 | S&F LED Bulbs 23 Watts, BEE star rated energy efficient Retrofit bulb, including taking down unserviceable lamp, complete all as specified & directed. |
| 99 | S&F LED Bulbs 10 Watts, BEE star rated energy efficient Retrofit bulb, including taking down unserviceable lamp, complete all as specified & directed. |
| 100 | M&L Plain cement concrete 1:4:8 type D-2( using 40mm graded crushed stone aggregate) as in foundation,filling and mass concrete in foundation of poles and stay assembly for bed concrete or as per site requirement complete all as specified and directed. |
| 101 | Supply and laying in trenches /laid in floor/duct/drawn through conduit XLPE insulated,screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable 1100V grade with aluminum conductor of cross sectional area 16 sqmm 4 core complete all as specified and directed. |
| 102 | S&F in repair copper flexible cable two core 2.5 sqmm PVC FRLS insulated and sheathed 1100 volts grade complete all as specified & directed. |
| 103 | S&F in repair of copper flexible cable three core 2.5 sqmm PVC FRLS insulated and sheathed 1100 volts grade complete all as specified & directed. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |