| 1 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature)1.0 TR with 3 Star BEE Rating |
| 2 | 1.5 TR with 3 Star BEE Rating |
| 3 | SITC of energy efficient 1.8 to 2 TR capacity Hot and Cold inverter type 3 star Rating , wall mounted split type AC Unit , suitable for operation at ambient tempreature from -2°C to 48°C with Copper condenser, nominal capacity suitable for operation on single phase, 220v, 50hz, AC supply i/c electronic remote control, comprising of both indoor and outdoor unit with swing/rotary compressor (as per OEM design) duly filled with suitable ecofrandly refrigerant, including Copper pipe work between indoor and outdoor including 9 mm nitrile insulation and 2 inch PVC pipe to cover copper pipe and suitable size/capacity copper conductor wire, PVC drain pipe of size 25mm i/c Elbow, Tee, Socket, Cement Solvent, 16 Amp Plug Top etc. complete as reqd. |
| 4 | Supply installation, testing and commissioning of wall mounted/terrace mounted bracket to withstand weight of AC outdoor unit, as approved by E-in-C, weather proof, suitable primer and painted, suitable for existing outdoor unit of Split AC mentioned in above item. |
| 5 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for Spit AC system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mmthick insulation |
| 6 | 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mmthick insulation |
| 7 | 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 8 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 9 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required3 x 6 sq. mm |
| 10 | 6 x 6 sq. mm |
| 11 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Medium Class PVC conduit as required.4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 12 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. |
| 13 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door |
| 14 | Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as requiredFor 4 way, Double door TPN MCBDB |
| 15 | Supplying and fixing following capacity, 240/415 Volts 'C' series MCB's suitable for lighting and other loads of following poles in the existing MCB DB complete with connection, testing and commissioning etc as reqd.100 A, 10kA, TPMCB (415 V) |
| 16 | Supplying and Fixing of following size/type DLP Snap on Trunking with accessories complete as required DLP trunking - Snap On - Monoblock: Body+cover 50 mm x80 mm - 1 compartment |
| 17 | Supplying and fixing 5 amps to 32 amps, 240 Volts 'C' series MCB's suitable for lighting and other loads of following poles in the existing MCB DB complete with connection, testing and commissioning etc as reqd.Single Pole |
| 18 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm Please Enable Macros to View BoQ information |