Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Modular kitchen - Under counter storage cabinets:Providing and fixing factory made modular kitchen cabinets in modular type knockable cabinet boxes with openable shutters and sufficient number of drawers made of 18 mm thk. ISI Marked comm. ply , all ply to be laminated with 0.8 mm laminate.All shelves should be supported on approved quality SS pins and shall be adjustable for different heights as per requirements.Shutters and drawers fascia shall be at least 18mm thic with laminate on both sides with 18mm wide 2mm thick PVC edge banding, All Shutters finished in high gloss acrylic of approved make- Rehau,Ornare,Senosan. The cabinet boxes of floor units will be supported by 100mm height vertical adjustable legs (Hettich make) which will be covered with PVC skirting (Rehau or equivalent make ) in brushed aluminum finish attached by hardware of skirting. The unit shall be fixed to the floor/ wall/slab using metal screws of appropriate size and rawl plugs. Only front face area of cabinets and skirting from floor to top of boxes shall be considered for measurement and payment. Cabinet boxes size would be varies from 400X560X710MM to 1000X560X710MM (approx.) and join together as per site requirements etc. |
| 2 | Modular Kitchen - Overhead storage wall units:Providing and fixing factory made modular kitchen cabinets in modular type knockable cabinet boxes with openable shutters and sufficient number of drawers made of 18 mm thk. ISI Marked comm. ply . all ply to be laminated with 0.8 mm laminate.All shelves should be supported on approved quality SS pins and shall be adjustable for different heights as per requirements.Shutters and drawers fascia shall be at least 18mm thic with laminate on both sides with 18mm wide 2mm thick PVC edge banding, All Shutters finished in high gloss acrylic of approved make- Rehau,Ornare,Senosan. The unit shall be fixed to the floor/ wall/slab using metal screws of appropriate size and raw plugs. Only front face area of cabinets and skirting from floor to top of boxes shall be considered for measurement and payment. Cabinet boxes size would be varies from 400X560X710MM to 1000X560X710MM (approx.) and join together as per site requirements etc. |
| 3 | Workstation - Providing and placing HNI make `Connect` Linear Workstation 1350 L x 600 W x 1200mm Ht with pedestal unit, Frame is 50 mm thick and made of vertical Aluminium Extrusions and Horizontal Steel Members of 1.2 mm to 1.5mm thickness. The System is complete hollow system with space for wire reticulation . All the frames will be duly powder coated . All the frames are fastened together by means of M6 NUTS and BOLTS . All the frames are fitted with M10 leveling bolts.board.Raceway :-The raceway cover are sliding type and are integrally fitting inside frame and are made out of 0.8mm - 1mm thick CRCA steel and powder coated. The electrical raceway can be provided below worktop or above worktop.The tables Should have metal inserts on underside for modularity. The screw used should be blunt headed and not sharp headed for metal to metal coupling . The partition has two integrated raceway provided one at skirting level and another at the work surface level thus ensuring separation of power and networking cables. The free space available within raceway accommodates power, data and communication cables. The cable can be taken into the Frame from the floor from the bottom. Tiles: Fabric Tile: Constructed out of 5mm thick Medium Density Fiber Board (MDF) and covered with Fabric of choice. Laminate Tile: Made out of 5mm - 8mm thick Pre-laminated Medium Density Fiber Board (MDF) . Bottom Row of Steel Tile: Constructed out of 0.8mm CRCA sheet and finished in epoxy powder coating. Can be given with plain / perforations / embossed finishes.Magnetic tile: Constructed out of 0.8mm Galvanized sheet and covered with fabric of choice. Whiteboard marker tiles: Made out of 4mm MDF with 1mm glossy highly wear resistant face laminate . Total thickness is 5mm. Table tops and Gable ends are of 25mm thk Pre-laminated particleboards conforming to IS : 12823 Interior Grade.The Worktops should have metal inserts on underside for modularity. The screw used should be blunt headed and not sharp headed for metal to metal coupling . Specially designed powder coated M.S. brackets having 2mm thickness fixed to the partition frame support the tabletops. Gable ends are of 25mm thk. both side laminate (BSL) with 2mm PVC edge banding on front side. Gable Ends are fixed with 3mm thick MS brackets to Frame and with 3mm thick Brackets to Worktops. Sealed edge in table top and gable ends are with2mm thick PVC edge banding on Working side and 0.8mm thick edge banding on non working side. Each Workstation has 3Drawer Pedestal unit of size 400mm L x 450mm D x 680mm made up of 18mm thk. Prelam particle board conforming to IS : 12823 Interior Grade with 3 Drawer ( 2 Drawer plus 1 Filing ) with roller slide mechanism for 2 Drawers and Ball bearing slide for 1 Filng Unit . 10 year warranty . |
| 4 | MDF Board 4mm thk fixed with nails complete in all respect |
| 5 | credit to workDismantled Iron from GI pipe |
| 6 | Providing and Fixing of PVC Wall Panelling complete in all respect to the entire satisfaction of engineer in charge |
| 7 | credit to workDismantled Iron from old broken scraps |
| 8 | Brick bat obtained from dismantling brick wall |
| 9 | Brick obtained from dismantling brick wall |
| 10 | 50MM THICK GI FRAME (FOR THICK PARTITION) for MDF : Providing and fixing metal system up to ceiling height, which includes frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 GSM, consisting of Boral U track 52mm wide having equal flanges of 30mm and 0.55mm thick (Base metal thickness) fastened to the floor slab and ceiling soffit using rawl plugs with screw at 600mm centers, with first and last fixing point at not greater than 50 mm from either end. Boral C studs 50mm wide having one flange of 34mm, other flange 36mm, lip size 6 mm and 0.55mm thick installed perpendicularly within the flanges of floor and ceiling channels located directly opposite to each other at not more than 610mm centers. Maintain 5 to 10mm gap between C Stud and web of U Track |
| 11 | WPC WALL PANELLING : Providing and Fixing WPC Wall panelling as per approved make and pattern as approved by the client and architect. |
| 12 | S/E of LED Panel of 36W surface/ recess mounting size 2`x2` of Philips make with energy efficient white colour as per satisfaction of Engineer in charge. |
| 13 | Providing and fixing cupboard / wardrobe including shutters sunmica handles etc complete in all respect |
| 14 | Providing and applying at all floors, heights and locations exterior based texture finish of heritage / spectrum make made from natural stone based materials and Bonding agent made from pure acrylic co-polymer emulsion, Broad fungicide and Bonding agent mixed to a recommended quantity of water and applied with a trowels on to the surface, to be finished, in an average uniform coat of 2mm covering an area of about 0.5 sqm /kg ofthe mix. giving a uniform surface texture applied by a trained flakes applicators in a single coat. The finish shall be anti fading and non pigmented type with resistance to weathering. The base has to be smooth sand faced cement plaster after duly clearing off any unwanted scratches and undulations by sand papering or using a wire brush before actual application begin complete. rate excluding gst |
| 15 | Supply and Fixing of Glass partition of 12mm Toughened Glass using slim line System Frames clip in profile to a height of maximum 3000 MM or as per drawing.The Fixed glass to be fixed using BP45 Profiles at Top and Bottom and fixed frame cleat . The profile size to be 45x25MM to be fixed on to the floor/ ceiling as per the architect design. H Junction profile to be used at all Glass to Glass vertical joints, 90 Deg L Junction Profiles and T Junction profiles necessary as per design.In case of Glass overall panel MP45 and BP45 Overpanel Profile to be used. Door frame with alexa EP End Profile frame of size 45X50mm with seals suitable for Glass door Patch Fitting with Top and Bottom patch having standard L=3000mm suitable for double action glass door . The clip in profiles shall be suitable for Glass thickness of 12 mm .The Profile shall be matt natural anodized, the Profile Manufacturer to supply all the necessary clips, seals and fixing accessories for the system complete in all respect as per architectural drawings and the directions of Architect/Engineer-in-charge. All Profiles to be with 2 mm Gauge thickness Excluding 20 Micron of Anodizing. Approved Manufacturer complete in all all respect as per direction of Engineer-in-charge. |
| 16 | Extra Cost for Glass Door Accessories i.e Pull Handle TGDIH ( 25mm dia X 450mm long ) H-Type Pull handle back to back with 350mm CTC, adjustable fixing for glass ,Length =450mm, 25mm dia, -SS304 Finish: mill , . spindle and cover plate ,US 10 Std. Corner lock plus Strike plate and EPC. As per DIN EN 1154.(500,000 cyle tested ) , Finish: Satin stainless steel. Floor stop half dome with 45mm dia with fixing accessories, in satin Chrome ,Final certifications of products should be submitted be from the product manufacturer for the originality of the product and manufacturer should be have its own service team . The above work complete in all respect as per approved drawings and to the satisfaction of Architect /Engineer-in-Charge. |
| 17 | Providing and fixing of approved make translucent, cast PVC, self - adhesive vinyl, special CRYSTALeffect film to reproduce Sand - blasting effect on glass at required locations as per the direction ofEngineer-In-Charge complete.a) Plain Frosted film` |
| 18 | PROVIDING AND FIXING IN POSITION HINDWARE/Kohler/Jaquar MAKE Star White Viterous Chinaware Urinal of Hindware having in compatibility with Cat no. URS-WHT13261 of Hindware(Jaquar/Parryware) with Stainless Steel flush pipe, spreads,domed waste coupler and concealed urinal Self Closing cock having in compatibility with Cat no.F310003ACP of Hindware (Jaquar/Kohlar) and PVC waste pipe etc. with all OTHER NECESSARY FITTINGS and complete in all respect as per manufacturer`s specfication and satisfaction of Engineer-in-charge including cutting and making good the walls and floor where ever required completePROVIDING AND FIXING IN POSITION HINDWARE/Kohler/Jaquar MAKE Star White Viterous Chinaware Urinal of Hindware having in compatibility with Cat no. URS-WHT13261 of Hindware(Jaquar/Parryware) with Stainless Steel flush pipe, spreads,domed waste coupler and concealed urinal Self Closing cock having in compatibility with Cat no.F310003ACP of Hindware (Jaquar/Kohlar) and PVC waste pipe etc. with all OTHER NECESSARY FITTINGS and complete in all respect as per manufacturer`s specfication and satisfaction of Engineer-in-charge including cutting and making good the walls and floor where ever required completewithout gst |
| 19 | `Providing and fixing Urinal partions of standard dimensions made of 10 mm thick toughened frosted Glass, scratch and impact resistant. The urnial partions shall be fixed on walls with right angle brackets in stainless steel of grade 304 with necesary stainless steel screws of grade SS 304 complete as per the direction of Engineer incharge. (Jaquar Cat no.JSE-CHR-810US450X or approved equivalent)a) Urinal partition of size 1200 mm x 450 mm.` |
| 20 | Providing and fixing 6mm thick extra clear bevelled edge mirror fixed on walls with stainless steel studs of appropriate size and dia at four corners of glass and 6mm thick waterproof ply/sheet backing complete as per direction of the Engineer-In-Charge. |
| 21 | Providing and fixing square-mouth PVC gully trap of size 160 x 110 mm complete with brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design complete in all respect to complete Satisfaction of Engineer-in-charge:With Fly ash lime bricks (FALG Bricks) conforming to I.S. 12894. Astral/ Supreme/Finolex or equalent make size 160 x 110 mm |
| 22 | Providing and fixing in position UPVC SWR specials for soil waste vent or anti syphonage pipes (Supreme or approved equivalent) as per IS-13592 including cutting, jointing with approve solvent,rubber ring etc. and other accessories including cement compound as per IS-14735complete as per manufacturer`s specifications and as per direction of the Engineer In-charge.For 110 mm o/d pipe line1) Bends |
| 23 | Providing and fixing in position UPVC SWR specials for soil waste vent or anti syphonage pipes (Supreme or approved equivalent) as per IS-13592 including cutting, jointing with approve solvent,rubber ring etc. and other accessories including cement compound as per IS-14735complete as per manufacturer`s specifications and as per direction of the Engineer In-charge.For 110 mm o/d pipe line2) P-Trap |
| 24 | Providing and fixing in position UPVC SWR specials for soil waste vent or anti syphonage pipes (Supreme or approved equivalent) as per IS-13592 including cutting, jointing with approve solvent,rubber ring etc. and other accessories including cement compound as per IS-14735complete as per manufacturer`s specifications and as per direction of the Engineer In-charge.For 110 mm o/d pipe line3) HRB |
| 25 | Providing and fixing in position UPVC SWR specials for soil waste vent or anti syphonage pipes (Supreme or approved equivalent) as per IS-13592 including cutting, jointing with approve solvent,rubber ring etc. and other accessories including cement compound as per IS-14735complete as per manufacturer`s specifications and as per direction of the Engineer In-charge.For 110 mm o/d pipe lineCleanouts |
| 26 | `Providing and fixing uPVC Floor Traps for soil waste vent or anti syphonage pipes (Supreme or approved equivalent) as per IS-13592 and IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition complete as per manufacturer`s specifications and as per direction ofthe Engineer In-charge.` |
| 27 | Providing, Supllying , installing, commissioning and testing Non Self priming, Multi Stage, Horizontal Centrifugal Pumping Set (monoblock booster pumps) with Electric controller level indicator and Auto cutoff, Switch etc. gate valve and non return valve with other accessories complete in all respect`Mono pump Discharge-450 LPM Head-20 mtr BHP-2 ` |
| 28 | `S/E of LED 16W LED downlighter SM200C LED16S 6500 PSU OD WH square surface/recess mounting white colour working hour minimum 35000 hours, operation on single phase AC supply complete in all respect upto he entire satisfaction of Engineer- in -charge of the work including making necessary connections etc. ` |
| 29 | S/E of LED 10 watt rectangular bulk head fitting with opal diffuser and 10 watt LED i/c erection of fitting in wall/Ceiling and making necessary connection to complete the job with all labour and petty material as required(Make:- Havells / Model- Endura Rugby or equiavalent model of other approved brands). |
| 30 | Supply and Erection of surface mounting LED Batten fitting 20 watt (4 feet long) BN021C LED22S PSU CW GR , white colour, working hour minimum 50000 hours, operation on single phase AC supply complete in all respect upto the entire satisfaction of Engineer- in -charge of the work including making necessary connections etc. |
| 31 | Pannels:Incomer1 Nos. 125A 4P MCCB with built in thermal magnetic release (Ics = Icu = 25kA) with inbuilt O/L , S/C and E/F protection as per specification and each with following accessories.1Set of R,Y,B phase indication lamps with control MCB as per fault requirement for each Incomer.Busbars3Nos. SPN copper insulated bus bars link of minimum of 160AmpsOutgoings1Nos. 25A FP MCB2Nos. 40A FP MCB1Nos. 63A FP MCB1 Nos. 6-32A, DP MCB 10kA `C` Curve3Nos. Neutral and Earth link. (One for Each Phase) |
| 32 | Supplying, installing, testing and commissioning of 24 port Cat 6 patch panels available with block of four equipped with tool less IO, Rack Mountable. 19` Modular Patch Panel, loaded CAT6 U/UTP 24 port LCS2 rack mountable to be compatible in 4nos of 6 X RJ 45 Tool less connector U/UTP unit in a block complete as required. |
| 33 | Supplying, Installation, Testing and Commissioning of 24 port 10/100/1000BASE-T ports and four GbE/10GbE SFP/SFP plus uplink ports layer 3 from day1 having static and RIP , stackable upto 10 switches, should support external redundant power supply, certified EAL3 , each switch should be provided with stacking port/cable. |
| 34 | `Design, manufacture, supply, installation, testing and commissioning of 13 passenger / 1088 kgs (Gear Less,without Machine Room) Strecher Lift, with travel speed 1.00 MPS serving different floors in the lift shaft, including lift well pressurization as per detailed specification/drawing enclosed and as under.Specifications: Type-13 Person ,Gear less without Machine Room, Speed-1.00 mps , Travel -10 Mtr. (approx) G plus 3 = 4 Stops, 4 Openings (all on the same side), Host way required: 1850 mm W X 1950 mm, D- Car Size: min. 1.61sq mtr and max 1.76 sq mtr, Car Entarance-Clear Opening: 800mm W X 2000mm H, Central Opening doors in SS Honey Comb/Hair Line Finish scratch resistance/vendal proof, Pit Deptht-1600 mm below the finish floor level of first landing, Headroom - 5000mm, Simplex control sytem (V3F Microprocessor based Selective Collective Simplex Control with and without attentent ), Car-SS Honey Comb/Hair Line Finish scratch resistance/vendal proof,Automatic DC Power Operated with adjustable door opening and closing timings, `Power Supply: 415 Volts, 3- phase, 50Hz Alternating Current , Flooring -PVC Flooring Skid - Resistant as per standard, Automatic Rescue Device, Infra-Red Screen Sensor, Over Load Warning Indicator with announcement, Full Load Bypass, Braille buttons, Hand Rail: Stainless Steel round Hand rail not less than 600mm long at 900mm above floor level (Side LH,Side RH and Rear), Stainless Steel Mirror Finish False ceiling in Car, Cross flow fans for ventillation in car, Dot Matrix Led D and P Indicators in Car and Landins - Orange colour, Push Button - Orange LED Illumination, 3 way intercom - Press and Speak / Full Car operating panel placed at a height between 800mm-1meter from the floor level, Floor Annunciator with music, Sill Angle, Sill Support, Fireman’s Switch, Battery Operated Alarm Bell and Emergency Light, Minor Builders Works, Scaffolding, Pit Ladder, Lift License, Free Service Two Years after the S/I/T/C Work and All other std Govt. features. Make of Materials: As approved in the PHSC Department |
| 35 | Supply, Erection, Testing and commissioning of of 24 10/100/1000 Base-T auto-sensing ports, 100/1000/10G BASE-T RJ45 Ports, 1000/10GBASE-X SFP plus ports, 1 RPS Connector, 1 USB Storage (image, config, log files) ,CPU: 800 MHz, RAM: 512 MB, Packet buffer memory: 32 MB, Flash:128 MB, Stack height: 6 switches, Bandwidth: 128 Gbps non-blocking, Throughput : 95.2 Mpps,(MTBF): 278,559 hours, Forwarding modes: Store-and-forward, MAC Address database size: 16,000 media access control (MAC) addresses, VLAN: 256, 1024 Multicast Groups, 32 Static Routes, 15 Routed VLANs, 512 ARP Cache entries, 8K DHCP snooping bindings, 100 shared for MAC, IP and IPv6 ACLs, IEEE 802.3 Ethernet, IEEE 802.3i 10BASET, IEEE 802.3u 100BASE-T, IEEE 802.3ab 1000BASE-T, IEEE 802.1Q VLAN Tagging, IEEE 802.3x Full-Duplex Flow Control, IEEE 802.1Qav1, IEEE 802.3z Gigabit Ethernet 1000BASESX/ LX, IEEE 802.3ae 10-Gigabit Ethernet Over Fiber (10GBASE-SR, 10GBASE-LR, 10GBASE-ER, 10GBASE-LX4), IEEE 802.3an 10GBASE-T 10 Gbit/s Ethernet Over Copper Twisted Pair Cable, IEEE 802.3ad Trunking (LACP), IEEE 802.1AB LLDP with ANSI/TIA-1057 (LLDP-MED), IEEE 802.1p Class of Service, IEEE 802.1Qat1, IEEE 802.1D Spanning Tree (STP), Access Control Lists (ACLs) L2 / L3 / L4, IP-based ACLs (IPv4 and IPv6), MAC-based ACL, TCP/UDP-based ACL,MAC lockdown,MAC lockdown by the number of MACs,IEEE 802.1x Radius Port Access Authentication, L2 MAC, L3 IP and L4 port ACLs, IEEE 802.1Q VLAN tagging, IP-based VLANs, MAC-based VLANs,Auto-Voice VLAN : Based on phones OUI bytes (internal database, or user-maintained) or protocols (SIP, H323 and SCCP), Stacking Interface : 10G SFP plus or 10GBASE-T copper (both at 10G speeds only), Max. number of switches within a stack : up to 6,Stacking bandwidth : 40G bi-directional, Certifications: CE mark, commercial,FCC Part 15 Class A, VCCI Class A, Class A EN 55022 (CISPR 22) Class A, Class A C-Tick, CSA certifi ed (CSA 22.2 #950), UL listed (UL 1950)/cUL IEC 950/EN 60950. OEM Must have Local Office in Punjab/Chandigarh for Quick Support. All Switches and Networkiing Components from Same OEM. OEM should be present in Gartner Quadrant from last 5 years. Makes Juniper, Netgear, Cisco . |
| 36 | Supply, Installation, Testing and Commissioning of Wall Mount 15U x 600 W x 600 D ,Front Glass Door (tinted,Toughened) with Lock and Key, 2 pairs of 19` Mounting Rails with U-Marking,Welded Side Walls With Metal Engraved D-Link Logo, 1U Cable Manager (1), Hardware Packet (1 Pkt), 6 Socket 5 Amp. Power Distribution Unit (1 No) Roof Mounted Fan Unit / 90 CFM /230V AC (1 No). Rack should be as per DIN41494 Standards.OEM must be ISO 9001,14001 certified. Make: Rittal, APC, D-Link, Valrack, Panduit . |
| 37 | Supply, Installation, Testing and Commissioning of Patch Panel 20 cat-6 plus 4 cat-6A port should be made of cold rolled steel should be conform to TIA / EIA 568-C.2 component compliant. All information outlets for 100O, 22-24 AWG copper I/O should be supplied with cap or shutter to avoid dust.Patch panel should terminate 24 UTP CAT 6 (4 pair) Cables. Patch Panel should confirm to EIA/TIA 568A wiring pattern.Patch panel should be with an integral cable management tary for cable strain relief and tidy cable dressihg.Patch panel should be RoHS compliant. Make: Legrand, Commscope, Panduit, Beldon, Systimax. |
| 38 | Supply,laying and termination of CAT 6 Cable should be unshielded twisted pair cabling system, TIA / EIA 568-C.2 Category 6 Cabling system. Network support should be ultra high speed data networks such as Gigabit Ethernet (1000 Base-T and 1000 Base-TX) and beyond. Cable should be ETL Verified, UL Listed and UL channel verified- all three certificates are mandatory. Conductors type should be 23 AWG solid bare copper. Frequency tested should be up to 600 MHz minimum Impedance should be 100 ± 15 Ohms. Propagation delay should be 535ns/100m @250MHz Standard color should be available (Blue, Grey, Red and Yellow).cable should be RoHS compliant. Approved Make : Legrand, Commscope, Panduit, Beldon, Systimax . |
| 39 | Supply, Installation, Testing and Commissioning of Patch Cord 0.5 Mtr. Should be 4 Pairs 24 AWG copper cables.The outer jacket should be Low Smoke Zero Halogen.should be 24 AWG stranded bare copper.Patch cord should minimum comply with proposed ANSI/TIA/EIA-568-C.2.Patch cord should be verified UL/ETL.Patch cord should have cross separator. Standard length should be available 0.5mt to 10 meter. Standard color should be available (Blue,Grey,Red,Yellow,Green and white).Should be RoHS compliant. |
| 40 | Supply, Installation, Testing and Commissioning of Patch Cord 2 Mtr. Should be 4 Pairs 24 AWG copper cables. The outer jacket should be Low Smoke Zero Halogen.should be 24 AWG stranded bare copper. Patch cord should minimum comply with proposed ANSI/TIA/EIA-568-C.2. Patch cord should be verified UL/ETL. Patch cord should have cross separator. Standard length should be available 0.5mt to 10 meter. Standard color should be available (Blue,Grey,Red,Yellow,Green and white) and it should be RoHS compliant. |
| 41 | Supply, installation, testing and commissioning of analog phone with caller id and hand free facility complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Beetel, P-Tel, Binatone, Panasonic, Siemens. . |
| 42 | Supply, installation, testing and commissioning of Executive SIP desktop phone 7” (800x480 pixel) color LCD touch display, bluetooth 4.1, mobile link, mobile device integration, mobile phone charging point, cordless speech optimized handset, Enhanced full-duplex speaker phone, Programmable Personal soft touch keys for access to Lines, Speed Dials and Telephony functions, Context sensitive touch soft keys, 11 dedicated feature keys,lus dial pad, Dual 10/100/1000 Mbps Ethernet port, (LAN/PC), MobileLink, Mobile pairing via BT, Mobile Call Audio via desk phone, Mobile Contact Sync, Mobile Charging (USB,ort) Speech optimized cordless handset, Hearing aid compatible (HAC) handset, Full-duplex high quality speakerphone, Codecs (not all codecs supported by MiNet and SIP firmware): G.711, G.729, G.722, G.722.1 (MiNet only ), G.726, iLBC AMR, AMR-WB (G.722.2) (SIP only), Headset connection interfaces – USB, Accepts standards-based (IEEE 802.3af), Power over Ethernet (PoE), PoE Class 3 with automatic PoE Class, change on Expansion Module installation, Supports local powering via. 48VDC PoE injector or 48VDC wall adapter, MTBF Rate: 40 years, Canada: CS03 Part V (Hearing Aid Compatible), USA: FCC part 68 (CFR 47) (Hearing Aid,Compatible), Australia/New Zealand: PTC220, AS/CAS004, AS/ACIF 2040. Make: Cisco, Aastra, Nortel, Ericsson, Mitel, Tadiran, Awaya. . |
| 43 | Supply, installation, testing and commissioning of Sip Extension with its license for IP telephones. Make: Cisco, Aastra, Nortel, Ericsson, Mitel, Tadiran, Awaya . |
| 44 | Supplying, Installation, Testing and Commissioning of weather proof cabinet for hose fabricated out of 1.6mm thickness M.S. sheet with front glass door having locking arrangement, suitable to accommodate all the necessary pipes, accessories, fittings etc including painting the metal portion with one coat of ready mixed primer paint and two coats of synthetic enamel paint of approved shade and quality, sign writing etc.600 mm wide x 600 mm high x 300 mm deep Size - (for RRL Reel) |
| 45 | Supply, installation, testing and commissioning ISI marked (IS:15683) Fire Extinguisher, Carbon-di-oxide type capacity 22.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 and wall suspension braket as required as per specifications |
| 46 | Supply, installation, testing and commissioning of 6kg ABC (Powder Type) Fire Extinguisher. Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC 90 powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:15683 as required as per specifications. |
| 47 | Supply and erection of 1KVA Online Line sine wave UPS/ Power Plant with in built SMF batteries having 30 Minutes backup time complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. . |
| 48 | Supply and erection of Cat 6A information outlets with face plate (Tool less) should be designed to support 10 Gigabit networks and can be easily terminated using parallel jaw pliers. The termination is accomplished by placing the conductors into the proper wire slots in the wire cap. The termination Jack Should be UL listed. The IDC is design to accommodate different diameter conductors from 22 AWG-26 AWG Solid Wire. The field terminable plug should be meets TIA-568-C.2 Category 6A component performance. Cat 5e/6 and 6A direct Attach link and channels. Termination capability should be solid wire 22-26 AWG copmlete with Faceplate and SMB Approved Make: LEGRAND, SIEMON, MOLEX, PANDUIT |
| 49 | `Supply, Installation, Testing and Commissioning of the Switching system of the EPABX for should be designed with IP at the core allowing fully distributed IP solutions across data networks in 19” Rack Mountable, 7 universal slots in single Node and should support card Analog Extension Card, Digital Extension Card, for the respective addition / expansion. Analog and Digital extensions can be increased in the steps of 8, 16 and 32 Ports. Analog Trunks, PRI, BRI Trunks, E1 and SIP Trunks . Single card /module should support 2 or more PRIs, It should support 100% IP or 100 % TDM or a hybrid of IP/TDM technologies. The EPBAX configured for 08 trunk lines, 68 analog extension card. The system should support IP Communication Devices (wired and wireless) e.g. IP Phones (Hard and Soft phones), Mobile IP Phones, multimedia PCs, SIP phones, Video phones (Hard and soft), etc. The system should also support Legacy TDM communication devices (Digital and analog 2 Wire telephone instruments with or without caller-id (Both FSK and DTMF), Fax, modems, ISDN phones etc. The proposed system should support direct SIP integration with Microsoft Lync 2013 including following. Vendor should provide proper document towards certification with Microsoft Lync 2013 integration. The system should support at least 228 analog extensions in a single node and up to 600 analog Extensions in multiples nodes at least 400 Digital Phones in a single node and 600 digital phones in multiple node,support at least 600 SIP extensions in a single node, Support 600 DECT/SIP DECT phones.support at least 224 DECT base stations and over 4000 SIP-DECT Base stations should support minimum 56 Analog Trunks ,56 ISDN BRI trunks,14 PRI Trunks.Fax over IP with T.38 Interface and should support minimum 140hannels.240 SIP access channels. The system should have in-built Auto Attendant and Voice Mail system.Make : Cisco, Aastra, Nortel, Ericsson, Mitel, Tadiran. . |
| 50 | Supply and erection 100 Pairs MDF plus 100 Pair IDF with Krone Modules and Lockable Box complete in all respect as desired by the engineer in charge at site. . |
| 51 | Supply and Erection of 30 Pair DB with Original Krone Module lock and key facility complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. . |
| 52 | Supply and erection of 02 Pair 0.5mm PVC Dual sheathed Telephone Cable as per ITD Specification 113-B With Up to amendments complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. . |
| 53 | `Supply and erection of operator console with following features 7” (800x480 pixel) touchscreen LCD with cordless handset, DSS 4.3” 480x272 pixel color backlit LCD display with 28 programmable keys, if required then (optional) can be daisy-chained for a combined total of up to 3 modules of 28 programmable keys on each module. All attached PKM’s powered by the phone no. separate power adapter required. Tthere should not be any cordcoil for connection IP phone based with hand set 2 x Giga ethernet ports built in bluetooth 4.1 support 96 (16 x 6) programmable keys 6 softkeys Mitel Hi-Q Audio technology hearing aid compatible (HAC) handset Codecs (not all codecs supported by MiNet and SIP firmware): G.711, G.729, G.722, G.722.1 (MiNet only ), G.726, iLBC AMR, AMR-WB (G.722.2) (SIP only) powered USB 2.0 host port (500mA) sidecar expansion port PoE Class 3 with automatic PoE class context sensitive soft keys bluetooth wireless interface mobile integration, Mobile Call Audio via desk phone, Mobile Contact Sync, Sidecar expansion port, Dedicated 4-pin modular headset port convertible to DHSG/EHS capable, Support for Mitel Teleworker Solution, Automatic Call Distribution (ACD) agent and supervisor, hot desking and resiliency, Secure encrypted voice communication, Quality of Service support – IEEE 802.1 p/Q VLAN and priority tagiing, IEEE 802.1 x authentication support USB charging port. Make: Cisco, Aastra, Nortel, Ericsson , Mitel, Tadiran, Awaya . |
| 54 | Supply, Installation, Testing and Commissioning of LED Display Monitor high resolution, Diagonal size :43`, Type 60 Hz LED BLU, Resolution 1,366 x 768 (16:9), Brightness 330 nit, Contrast ratio 4,000:1, Display colors 16.7 M, Dynamic C/R 50,000:1 (AV mode), Connectivity HDMI, VGA, Power supply AC 100 - 240 V ~ ( plus /- 10%), 50/60 Hz, Operating temperature 0°C - 40°C (32°F - 104°F), Built-in speaker (10 W plus 10 W), PIP/PBP, narrow bezel, light weight, RS-232C in/out 1 D-sub and 1 HDMI, no function key, 5 Star Rating |
| 55 | Supply, Installation, Testing and Commissioning of 2 MP fixed lense IP Dome Camera Image Sensor:1/2.8` Progressive Scan CMOS, Signal System: PAL/NTSC, Min. Illumination: Color: 0.01 Lux @(F1.2: AGC ON), 0.028 Lux @(F2.0: AGC ON), Shutter time: 1/3 s to 1/100,000 s, Slow shutter: Support, Lens: 2.8 mm, horizontal FOV: 114°, vertical FOV: 62°, diagonal FOV: 135°, Lens Mount: M12, Adjustment Range: Pan: 0° to 355°, tilt: 0° to 75°, Dayand Night: IR cut filter with auto switch, Wide Dynamic Range: Digital WDR, Digital noise reduction: 3D DNR, Video Compression: H.265 plus /H.265/H.264 plus /H.264/MJPEG, Video bit rate: 32Kbps~8Mbps, Max. Image Resolution: 1920 x 1080, Image Enhancement: BLC/3D DNR, ROI: 1 fixed region for main stream and sub-stream, Day/Night Switch: Auto/Scheduled/Day/Night, Alarm Trigger: Motion detection, video tampering alarm, network disconnected, IP address conflict, illegal login, HDD full, HDD error, General Function: One-key reset, Anti-Flicker, heartbeat, mirror, password protection, privacy mask, Watermark, IP address filtering, System Compatibility: ONVIF (Profile S, Profile G),ISAPI, Audio: 1 Built-in mic, mono sound, Operating Conditions: -30 °C ~ 60 °C (-22 °F ~ 140 °F) Humidity 95% or less (non-condensing), Power Consumption: 12 VDC, 0.4 A, Max: 5W, Weather Proof: IP66, IR Range: Up to 30m, Signal System: PAL/NTSC Min. Illumination: Color: 0.01 Lux @(F1.2: AGC ON), 0.028 Lux @(F2.0: AGC ON) Shutter time: 1/3 s to 1/100,000 s, horizontal field of view: 86°, vertical FOV: 46°, diagonal FOV: 102 |
| 56 | Supply, Installation, Testing and commissioning of Hard Disk of below stated rating, including fixing accessories and cable termination with required, complete in all respect as per instruction of engineer in-charge. Recording shall be calculated at 720P, 15fps enable motion based recording for minimum 30 days. HARD DISK 6 TB |
| 57 | Supplying, installing, testing and commissioning of CAT6, Tool less Information outlet. Cat6 U/UTP built in crimping hands-free, minimum 5 times reconnection possibilities. LCS2 Toolless RJ45 Information outlet where insertion test (IN and Out) must be 2500 times (I/O) along with front side Label holded and transparent shutter for projection Arteor category white in colour, including front plate and anodised GI box in concealed manner of adequate sizes,including all fixing accessories. |
| 58 | Supplying, laying, dressing, ferruling and terminations at both ends of following length of Cat - 6 patch cord. 4 Feet : CAT6 UTP 23 AWG Patch Cord - 1 mtr - Rack End. Factory crimped LCS2 Patch cord complete as required. |
| 59 | Supply and erection of 20 Pair 0.5mm PVC Dual sheathed telephone Cable manufactured as per ITD Specification with Up to amendments complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.. |
| 60 | Supply, Installation, Testing and Commissioning of Server Rack/Network Enclosure Frame-800X1000-STEEL with accessories like fan, pdu, cable manager,castors wheels etc.Adjustable Levellers set of 4,19` Reduced Channel - Loop Type with Window Moldings,Glass Door-800-42U Single,Metal Vented Rear Door Double,Side Panels-1000-42U-Vented,Mounting Hardware-(Pack of 20),FHU with 4 FAN 360CFM,Vertical Power Distribution Unit with 12 x 5/15 sockets Round Pin, 230 Volts AC, 32 Amp with Plug,Horz. Cable Manager-1U-Loop. as per DIN 41494 or equivalent standard Make: RITTAL, Mountxross, PANDUIT. |
| 61 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)Horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-`F` insulation, conforming to IS-325.M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.Suitable cement concrete foundation duly plastered and with anti vibration pads.900 lpm at 35 m Head |
| 62 | Providing laying, testing and commissioning of `C` class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation and providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.150 mm. Dia |
| 63 | Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm. Dia |
| 64 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel |
| 65 | Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetai/Stainless Steel coupling and cast iron wheel, lSI marked, conforming to IS 5290 (type A) with blank Gunmetai/Stainless Steel cap and chain as reauired:Single headed Stainless steel |
| 66 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304) |
| 67 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve and nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve and M.S. Pipe and socket.30 m |
| 68 | Supplying and fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304) |
| 69 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way - 100 mm dia M.S. Pipe |
| 70 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :100 mm dia |
| 71 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :150 mm dia |
| 72 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia |
| 73 | DSR 17.1.1 Supplying, installation, testing and commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required. |
| 74 | DSR 17.1.4 Supplying, installation, testing and commissioning of manual call box of ABS type in surface/recess with stainless steel chain and hammer assembly complete with glass and push button etc. as required. |
| 75 | DSR 17.1.5 Supplying, installation, testing and commissioning of response indicator on surface/recesss MS box having two LEDs metallic cover complete with all connections etc. as required. |
| 76 | DSR 17.1.7 Supplying, installation, testing and commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate and suitable for operation withamplifier i/c line matching transformer etc. complete as required. |
| 77 | DSR 17.1.8 Supplying, installation, testing and commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob and speaker/microphone enclosed in a M.S. (16SWG)/ ABS box with break glass in front etc. as complete required. |
| 78 | 17.1.9 Supplying, installation, testing and commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.17.1.9.1 4 Zone |
| 79 | DSR 17.1.11 Supplying, installation, testing and commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 6 zone panel for fire alarm system 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required- 2 Nos.(one to act as standby)Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set. Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set. Amplifier change over switch for inter changing amplifier- 1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No. Gooseneck microphone with stand and ON/OFF switch -1 No. Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters and ammeters terminal blocks etc. complete as required -1 set. Battery charger trickle cum boost to take complete load of fire alarm and PA system complete with all accessories including providing and fixing of 2 nos. 12 volt,30 AH each sealed maintenance free batteries -1 set. |
| 80 | DSR 17.5.1 Supplying and laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring and LSZH outer sheath complete as required. |
| 81 | DSR 17.2.9 Supplying, installation, testing and commissioning of intelligent addressable thermal detector with rate of rise cum fixed temperature thermister complete with basr as required. |
| 82 | Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked / approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and confoming to IS:910 50 Litres (trolley mounted) |
| 83 | DSR 1.14.6 Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 2 X 16 sq. mm plus 2 X 6 sq. mm earth wire |
| 84 | Item Description |
| 85 | Construction of multi storey office builidng at 66kv HVPNL Substation Hodal (CM announcement) under Circle Palwal Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail