| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. all kind of soil DSR Code No. 2.8.1 |
| 2 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. DSR Code No. 2.25(a) |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 Cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources). DSR Code No. 4.1.10 |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources). DSR Code No. 4.1.3 |
| 5 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. DSR Code No. 4.12 |
| 6 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) DSR Code No. 5.1.2 |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources):DSR Code No. 5.2.2 |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). DSR Code No. 5.3 |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for. (5.9.1) Foundations, footings, bases of columns, etc. for mass concrete DSR Code No. 5.9.1 |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for. (5.9.3) Suspended floors, roofs, landings, balconies and access platform. DSR Code No. 5.9.3 |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for. (5.9.5) Lintels, beams, plinth beams, girders, bressumers and cantilevers. DSR Code No. 5.9.5 |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for. (5.9.6) Columns, Pillars, Piers, Abutments, Posts and Struts. DSR Code No. 5.9.6 |
| 13 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.DSR Code No. 5.22.6 |
| 14 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.DSR Code No. 5.30 |
| 15 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (6.1.2) Cement mortar 1:6 (1 cement : 6 coarse sand). DSR Code No. 6.1.2 |
| 16 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (6.4.2) Cement mortar 1:6 (1 cement : 6 coarse sand) DSR Code No. 6.4.2 |
| 17 | Brick work in foundation & plinth with old dismantled bricks (supplied by department free of cost) and coarse sand mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. (NSI), Ref. CSI No. (6.18) SOR 23-24 |
| 18 | Same as in item 6.18 above but in super structure for 230 mm thick wall. (NSI), Ref. CSI No. (6.19) SOR 23-24 |
| 19 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. DSR Code No. 10.1 |
| 20 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).. DSR Code No. 10.28 |
| 21 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. DSR Code No. 10.29.2 |
| 22 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : (10.30.1) 4.0 mm thick glass panes. DSR Code No. 10.30.1 |
| 23 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors.40 mm wide and 4 mm thick DSR Code No. 11.13.1 |
| 24 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (11.3.1) 40 mm thick with 20 mm nominal size stone aggregate DSR Code No. 11.3.1 |
| 25 | Providing and laying of 16 mm thick baroda green stone in flooring or skirting,of approved shade, colour,size and pattern , laid over base cement mortar 1:4 mix including finishing the joints with white cement mixed with pigment to match the shade of granite floor including cost of all material, labour and T&P required for proper completion of the work, as per direction of Engineer incharge. . NSI Old SOR 2023-24 CSI NO 12.30 |
| 26 | 12 mm cement plaster of mix : (13.4.2) 1:6 (1 cement: 6 coarse sand) DSR Code No. 13.4.2 |
| 27 | Neat cement punning. DSR Code No. 13.18 |
| 28 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour Old work (one or more coats)DSR Code No. 13.81.1 |
| 29 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre :)DSR Code No. 13.41.1 |
| 30 | Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) : DSR Code No. 13.46.1 |
| 31 | Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (Two or more coats on existing cement paint surface applied @ 1.67 ltr/10 sqm. DSR Code No. 13.111.1 |
| 32 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old workDSR Code No. 13.99.1 |
| 33 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. completeDSR Code No. 13.88 |
| 34 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. DSR Code No. 13.80 |
| 35 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. (15.2.1) Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix). DSR Code No. 15.2.1 |
| 36 | Demolishing R.B. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge. DSR Code No. 15.4 |
| 37 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (15.7.1) In Cement mortar. DSR Code No. 15.7.4 |
| 38 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. DSR Code No. 15.56 |
| 39 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below DSR Code No. 15.12.1 |
| 40 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. DSR Code No. 16.91.2 |
| 41 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall (18.7.3) 25 mm nominal dia Pipes DSR Code No. 18.7.3 |
| 42 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (18.8.1) 15 mm nominal dia Pipes DSR Code No. 18.8.1 |
| 43 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (18.8.2) 20 mm nominal dia Pipes DSR Code No. 18.8.2 |
| 44 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. (18.50.1) 15 mm nominal bore DSR Code No. 18.50.1 |
| 45 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. (18.53.1) 15 mm nominal bore DSR Code No. 18.53.1 |
| 46 | Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havells or equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge. NSI SOR 2023-24 CSI No. 28.38 |
| 47 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Group C E&M -1.10.3 |
| 48 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10kA\\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole. E&M 2.10.1 |
| 49 | Supplying and drawing following 3 x 2.5 sq. mm sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. E&M -1.17.12 |
| 50 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet. E&M -1.24.4 |
| 51 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps E&M 2.12.2 |
| 52 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. E&M- 1.12 |
| 53 | Applying BIRLA PUTTY or equivalent putty on previousaly bila putty smoothen surface over one cost of water base cement primer of ICI or equivalent brand for smoothining and leveling of the surface as per requirement and direction of E/I including cost of all material , labour and T&P required for proper completion of work. NSI SOR 2023-24 CSI No. 13.21 |
| 54 | Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light fitting including tube on surface complete in all respect. NSI Ref. UPPWD SOR 2018 1413 (CAT-AA) |
| 55 | Providing and fixing of 110 mm dia PVC pipe 6 Kg/ Sq.cm for with special such as Tee, bend,socket, elbow etc including supply of all labour,material,T & P etc complete required for proper completion of work. NSI Old SOR 2023-24 CSI NO 26.17 |