| 1 | Wiring for light point/ fan/ exhaust fan point/ call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed 2 mm thick FRLS PVC conduit(HMS) with modular switch and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable including providing modular box with cover of requisite number of modules including providing cover plates as required as per technical specifications complete with making good the damages caused as required and as per direction of Engineer-in-charge.(Make: Legrand(Myrius)/ Anchor(Vision)/ Crabtree(Athena)conduit:Precision/AKG/Norpack (Wire Make:Gloster/KEI/Polycab/RR kable) |
| 2 | Group-A |
| 3 | Group-B |
| 4 | Group-C |
| 5 | Supplying and fixing two module stepped type electronic fan regulator with proper modular plate switch box including connections etc. as required.(Make: Legrand(Myrius)/ Anchor(Vision)/Havells(Morano) |
| 6 | Supplying and fixing 6 Amp plug with 6 Amp switch (Modular Type) on existing board. Legrand(Myrius)/ Anchor(Vision)/ Crabtree(Athena) |
| 7 | Supplying, fixing & wiring including testing and commissioning of 6A modular socket outlet with 6 Amp switch including providing GI modular box with faceplate etc as required. Legrand(Myrius)/ Anchor(Vision)/ Crabtree(Athena) |
| 8 | 1 nos 6 Amp 3-pin socket with 6 Amp switch. |
| 9 | Supply, installation, testing & commissioning of 6 / 16 Amp Plug Boards consisting of a 16 Amp clip-in type modular switch with indicator and a 6/16 Amp clip-in type modular socket fixed on metallic concealed box including interconnections and making good the damages caused complete as required and as per direction of Engineer-in-charge. Legrand(Myrius)/ Anchor(Vision)/ Crabtree(Athena) |
| 10 | Supplying,fixing of 2x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+2 nos 6A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 11 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 12 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 13 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 14 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 2 noS of single core 2.5 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit. (4X6+2X2.5) |
| 15 | Providing and fixing extra down rod of 20 cm length G.I. pipe 20 mm dia heavy gauge including painting etc as required . ( more than 5 cm lenght shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored. |
| 16 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 17 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 18 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 19 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.( fan Regulator compatible) |
| 20 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. |
| 21 | S/F of 4 way (4+12) TPN MCB DB double door with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 2 years |
| 22 | S/F of MCB 4 way Double Door SPN MCB DB of an approved ISI Make |
| 23 | Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 240 volts, MCB . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 years.. |
| 24 | Supplying and fixing 32 Amps rating,C series,10KA breaking capacity, 2P, 415 volts, MCB . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The MCB should be Replacement Warranty will be 1 year |
| 25 | Supplying and fixing 63Amps 4P 415 volts MCB ,C series,10KA breaking Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..Warranty on MCB is 1 years. |
| 26 | Supplying and fixing of following sizes of heavy gauge PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.Make-Precision/AKG/Norpack |
| 27 | 20 mm |
| 28 | 25 mm |
| 29 | Split AC |
| 30 | S/F of Copper 5 Star Rated 1.5 Ton Split type AC.Machine(LG-AS-Q20JWZE/ O-General-ASGG18CGWA-B/ Daikin-FTKU50XV16) make of LG/Daikin/O-General of ISI make. |
| 31 | Installation charges of 1.5 ton AC.machine.(As per Finalised Location) |
| 32 | S/F of 5KVA Voltage stabiliser having digital display ,intial time delay system i.e certified with ISO 9001:2008 with working range of (90-300)V of make V.guard/Autotake/Luminous. |
| 33 | Supply,installation of hard/soft copper refregrant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job. |
| 34 | MAIN PANEL FOR BUILDING |
| 35 | Supply ,Installation,testing & commissioning of main control panel wall mounted made out of CR sheet of 16 SWG and boarder angle frame to provide above panel with proper space,hinged door must be painted one coat of powder coating and two coat of enamel grey paint including wiring with appropriate size FRLS PVC single core multistrand copper cable,cable alley and connector with following arrangement.(Depth 15 cm to 30 cm) size (48'' x 48''x15'')=(1.2 x 1.2) sq.mtr |
| 36 | DIGITAL INSTRUMENT:- Voltmeter, Ameter,selector switch& Indicating lamp (R-Y-B) digital,CT coil up to 400 Amp - 1 Set |
| 37 | INCOMING |
| 38 | S/F of 200 Amp 4 pole MCCB, 36 KA with Spreader link with Extended Rotary Handle(L&T/Havells/Legrand) - 1 No. |
| 39 | 125 Amp TPN Changeover switch in open execution (Havells/L&T) - 1 No. |
| 40 | OUTGOING:-I |
| 41 | 63 Amp 4 pole MCB , (L&T/Legrand/Havells) - 6 nos |
| 42 | 63 Amp 2 pole MCBA(L&T/Legrand/Havells) - 6 nos |
| 43 | 32 Amp DP MCB (Havells/HPL/L&T) - 2 nos |
| 44 | CABLE AND ACCESSORIES:- |
| 45 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. |
| 46 | 3.5core x 50 sq mm |
| 47 | 4 Core x 16 sq.mm |
| 48 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 49 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size of 16 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 50 | Supplying and making end termination with double brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. A) 3.5core x 50 sq mm |
| 51 | Supplying and making end termination with double brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. B) 4 core x 16 sq. mm. |
| 52 | EARTHING INSTALLATION |
| 53 | S/IT/C of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The entire earthing system should be Replacement Warranty will be 2 years |
| 54 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 55 | S/F of Street light- 90W,120 lm/w efficacy ,IP PC Lens new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) |
| 56 | Supply & Laying of 2 core , 10 sq.mm Aluminium service Cable of an approved ISI Make ( Polycab/ KEI/ Nicco/Eq.) |
| 57 | S/F of 63 Amp 4 pole TPN Main switch (Havells/L&T) |
| 58 | S/F of 63 Amp 6 way TPN copper bus-bar (Havells/L&T) Please Enable Macros to View BoQ information |