| 1 | HYDT :Cost of drilling 200mmX165mmX250 Mtr deep bore well in all kinds of soil and rock in rural area for installation of pump bore set with Hydraulic DTH Rig machine, all complete including supplying all materials, tools, drilling rig, Air Compressor and equipments, as well as fuel, lubricants and cost of transportation of Rig machine and other vehicles up to the site. |
| 2 | (a) 0.00m Up to 50.00m depth below G.L. In Rural Areas (DWSD 119) |
| 3 | (b) Above 50.00 m depth. In Rural Areas |
| 4 | Supplying all tools, tackles & lowering of 200 mm dia MS ERW casing pipe of 6mm wall thickness including welding charges, cost of pipe etc. all complete job. (DWSD Item 120) |
| 5 | Supplying all materials, labour, tools & equipments for fitting & fixing 200mm dia MS cap over casing pipe complete job. (DWSD Item 120 B) |
| 6 | Cost of KSB or other standard approved make Submersible Pump Motor capacity of discharge 1.39 LPS water against total head of 70 M coupled with single phase 220/250 volt 50 c/s submersible motor pump including elbow, socket , nipple , union socket GM NR valve GM full way valve plastic rope as per required.suitable for 200mm x 150 mm HYDT |
| 7 | Cost of 2.5 sq mm 3 core 615 volt of flat PVC insulated copper cable of approved reputed make /FINOLEX make or equivalent . |
| 8 | Cost of control panel board consisting of main switch ,dry protector (0-50 amp ) ,Ampere Metre (0-500) ,Volt Metre,indicator lamp ,internal wiring with PVC insulated seethed copper wire etc, all complete. |
| 9 | Cost of 32 mm dia G.I. medium class 3.0 metre each length column pipe with one end socket and other threaded.(each length of column pipe should not be more than 3M) |
| 10 | Cost of lowering installation and commissioning of above set with all materials ,cutting threads if required and testing on full load including carrying up to the site . |
| 11 | Supplying tools and cutting road as well restoring the same as per specification and direction of E/I- |
| 12 | a) Pucka road (except black top only taken out materials to be used) for cutting road as per requirement |
| 13 | Earth work in excavation (as per is 3114/I965 for laying of different type and sizes of pipe so as to given one meter average cover over the socket of pipe with disposal of excavated earth within initial lead and lead as per specification and direction of Engineer in Charge |
| 14 | Earthwork in back filling thetren ches after laying different types and sizes of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in - Charge (for classification of Soil item A & B) |
| 15 | Providing and supplying High Density Polyethylene pipe (HDPE pipe) of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. PE-80 , PN- 10 |
| 16 | Providing and supplying High Density Polyethylene (HDPE ) fittings of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. PE-80 , PN- 10 |
| 17 | Lowering, Laying and Jointing H. D. P. E./M. D.P. E. pipes in proper position including all specials by compression fitting/electro fusion and butt fusion jointing procedure as per relevant IS Code complete with all materials for jointing procedure like Electro fusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II |
| 18 | Providing and fixing Gun metal full way / Gate valve / Stop cock of approved make all complete as per specification and direction of E/I. |
| 19 | 50 mm dia G.M. full way / Gate valve / Stop cock weight not less then 1.50 Kg |
| 20 | Providing and fixing Gun Metal N.R. Valves of approved quality all complete as per specification and direction of Engineer-in-Charge(50mm dia G.M. N.R. Valve weight not less than 600 gm ) |
| 21 | Earthwork in excavation in foundation trenches in ordinary soil (Vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 m. including all lifts, levelling, ramming the foundation trenches, removing roots of trees, shurbs all complete as per approved design, building specification and direction of E/I. |
| 22 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming ad watering in layers not exceeding 150 mm thick with all leads and lifts including costs of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. |
| 23 | Providing designation 75A one one brick flat soling joints filled with local sand including cost of watering taxes royalty all compete as per building specification and direction of E/I. |
| 24 | Providing P.C.C. M-100 with nominal mix of (1:3:6) in foundation with approved quality of stone metal grade - III ( 50 mm to 25 mm ), size clean coarse sand of F. M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of Engineer-in-charge. |
| 25 | Providing designation 75A brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortart joints, cost of screening materials, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction E/I. |
| 26 | Providing precast R.C.C. M-150 with nominal mix of (1:2:4) slab of desired size with approved quality of stone chips and clean coarse sand of F.M. 2.5 to 3 including curing, shuttering carrying the slab manually to site and laying in position all complete ( but excluding the cost of reinforcement ) taxes and royalty, all complete as per building specification and direction of E/I. |
| 27 | Providing tor steel reinforcement of 12mm & 16mm dia bars as per approved design and drawing exclding carriage of bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I TMT 12mm (TMT Coil Fe 500) only valid for Sail & Tata steel) |
| 28 | Providing 12 mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 29 | 18% GST |
| 30 | 1% labour Cess Please Enable Macros to View BoQ information |