| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:- |
| 2 | Short Point :- |
| 3 | Medium Point :- |
| 4 | Long Point :- |
| 5 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 6 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 7 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required. |
| 8 | 2 x 1.5 sq.mm:- |
| 9 | 2 x 2.5 sq.mm:- |
| 10 | 2 x 4 sq.mm:- |
| 11 | 4 x 6 sq.mm:- |
| 12 | 4 x 25 sq.mm:- |
| 13 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc conduit (medium gauge) complete with pvc switch board and fancy type switch with cover plate including connection etc as required |
| 14 | Short Point :- |
| 15 | Medium Point :- |
| 16 | Long Point :- |
| 17 | Wiring for Circuit/Sub-main with the following sizes PVC insulated Copper conductor cable (FR) in PVC conduit including connection etc. as required:- |
| 18 | 2 x 1.5 sq.mm:- |
| 19 | 2 x 2.5 sq.mm:- |
| 20 | 2 x 4 sq.mm:- |
| 21 | 2 x 6 sq.mm:- |
| 22 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/ surface including connection etc. as required. |
| 23 | 1 x 1.5 sq.mm:- |
| 24 | 1 x 1.5 sq.mm:- |
| 25 | 2 x 1.5 sq.mm:- |
| 26 | 2 x 2.5 sq.mm:- |
| 27 | 2 x 4 sq.mm:- |
| 28 | 2 x 6 sq.mm:- |
| 29 | 4 x 6 sq.mm:- |
| 30 | 4 x 25 sq.mm:- |
| 31 | Earthing with Copper earth plate 600 mm x 600 mm x 3 mm thick i/c accessories and providing masonry enclosure with CI cover plate Size 12\\"x 12\\" having locking arrangement, along with 20 mm dia (medium gauge) watering pipe including CC work etc as required:- |
| 32 | Extra for using salt (12 kg) and charcoal (96kg) for plate earth electrode as required. |
| 33 | Proving and fixing / Drawing 4.06 mm dia (8 SWG) Copper wire on surface or in existing G.I / PVC / Polythene pipe for loop earthing as required |
| 34 | Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of 4.06mm (8SWG) dia G.I./ Copper wire for earth connection from earth electrodes etc as required. |
| 35 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required. |
| 36 | 2 way SPN MCB DB (single door):- |
| 37 | (2+6)/8 way SPN MCB DB (double door):- |
| 38 | 4 way horizontal TPN MCB DB (Double door):- |
| 39 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required:- |
| 40 | 6 to 32 amps SP MCB:- |
| 41 | 40 amps DP MCB:- |
| 42 | 40/50/63 amps TPN MCB:- |
| 43 | Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:- |
| 44 | 40 amps DP isolator:- |
| 45 | Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):- |
| 46 | 125 amps FP MCCB, Breaking capacity 25KA (Thermal Magnetic) :- |
| 47 | Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required: |
| 48 | 100 amps 415 volts TPN main switch (rewireable):- |
| 49 | Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:- |
| 50 | 100 amps 415 volts four strip Copper busbar chamber 4 ways of size (455mmx330mmx120mm):- |
| 51 | Supplying and installation of fuse unit kitkat/HRC/HBC of the following ratings in existing main switch/panel board including necessary connection etc as required:- |
| 52 | 100 amps kitkat porcelain fuse unit with base(rewireable):- |
| 53 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 54 | Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp):- |
| 55 | Surface mounted round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 56 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 57 | 120 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 58 | 6 watt/10 watt LED Bulkhead light with high quality polycarbonate diffuser (IP 65):- |
| 59 | 40 watt LED post top light fixture with integral driver and high quality polycarbonate diffuser (IP 65):- |
| 60 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:- |
| 61 | 40 mm dia |
| 62 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:- |
| 63 | 12 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 64 | 18/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):- |
| 65 | Supplying & installation of 300 mm sweep 900 rpm metalic body exhaust fan including connection etc as required (ISI marked) :- |
| 66 | Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:- |
| 67 | Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required:- |
| 68 | Supplying & fixing of 40mmx6mm MS clamp for installation of ceiling fan/luminaries on cross bar including necessary accessories etc as required:- |
| 69 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required. |
| 70 | 5 step fan regulator (2M):- |
| 71 | Blank plate (1M):- |
| 72 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W). |
| 73 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:- |
| 74 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required |
| 75 | 3 core 4 Sq mm |
| 76 | Drawing of armoured/un-armoured cable with proper saddling etc as required:- |
| 77 | Excavation of earth for cable trench of 800mm depth & 300mm width in all kinds of soil including back filling of cable trench with the excavated soil with 20cm layer of sand, 3.5 nos bricks per metre for protection including ramming, consolidating to the original shape as per dirrection of Site Engineer :- |
| 78 | Supplying and fixing of M.S Box size (12\\"x8\\"x6\\") made of 3 mm size MS sheet with an arrangement of fittingMCB SP and Neutral link i/c rubber Gasket to the cover, water outlet duct to the below and locking arrangement. |
| 79 | Supplying and providing of 10 ft long alluminium self supporing ladder with stape folding system |
| 80 | Supplying and fixing of suspension type 26/30 watt LED well Glass luminairies with vertical/horizontal surface mounting pressure die cast aluminium housing and control gear compartment with suitable suspension chain including necessary connection etc as required. (Havells make-STUPEWGP30WLED757SSYMTOPCGRY/ Bajaj |
| 81 | Supplying and fixing of Copper terminal ends (LUGS) - long barrel of following sizes: - |
| 82 | 2.5 sq mm |
| 83 | 4 sq mm |
| 84 | 6 sq mm |
| 85 | 25 sq mm |
| 86 | Supplying and fixing of the following sizes PVC conduit(medium gauge) on surface with all accessories etc,as required. |
| 87 | 19/20 mm dia |
| 88 | 25 mm dia |
| 89 | Supplying and fixing of following i/c connection as required. |
| 90 | 1\\" flexible pipe( Present Market rate):- |
| 91 | PVC coupler 40mm/ 32mm( Present Market rate):- |
| 92 | Supplying and fixing of 'Fire Shield' brand ISI marked CO2 type Fire Extinguisher 2 KG capacity to IS: 15683: 2006 made from seamless cylinder conforming to IS: 7285 fitted with ISI marked controlled valve conforming to IS: 3224, discharge adopter and horn complete with initial gas charged with carrying handle and wall mounting Bracket suitable for operating between -30 degree centigrade to +55 degree centigrade, Fire rating class- 8B in/c necessary connection etc as required Please Enable Macros to View BoQ information |