| 1 | Providing Pumpset |
| 2 | OD524569/2025-2026:Supply, conveyance, installation, testing and commissioning of 5 HP , Open well Submersible motor pump set of pipe size 50 mm having a head range of 54 to 111mtr with a discharge of 180/65 on full load. .( Texmo Aquvatex sub-Pump 5 HP VTO 37 S R3-12 , KSB make or equivalent make etc as equired. |
| 3 | OD524564/2025-2026:Supply and provide BCH make Starter with protection against overload, single phasing, phase reversal & severely unbalanced voltages conditions, in accordance with latest IS/IEC 60947-4-1specifications suitable for 5 HP Submersibles motor pump set complete duly internally connected |
| 4 | 90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm |
| 5 | OD524567/2025-2026:Supply and providing ASHIRVAD UPVC ADAPTORSET 60MM[2"] DC CI |
| 6 | OD524568/2025-2026:Supply and Providing AQUATEX UPVC COLUMN PIPE 2" CE 20.0KG TCRUE004 with required accessories |
| 7 | OD524565/2025-2026:Supply and fitting of Pressure meter with accessories and stopper valve etc on delivery side of 50 mm GI pipeline as required |
| 8 | OD524563/2025-2026:Supply and fitting 50 mm GI Bend on pumping main with flanges welded and nut bolt etc on pumping main. |
| 9 | OD524566/2025-2026:Supply and fit FLANGE CI ROUND HEAVY 65MM with with all necessary accessories |
| 10 | OD524572/2025-2026:Supply and fixing 50 mm x 18" GI barrel nipple etc as required. |
| 11 | OD524562/2025-2026:Supply Providing KARTAR make NRV CI HEAVY ISI 50MM [2" for the pumping main |
| 12 | OD524583/2025-2026:Supply and providing GI pipe C class 50mm across the well for support to the submersible motor pump set |
| 13 | OD524584/2025-2026: Supply and Providing 50 mm GI pipe heavy Cutting threading welding and with accessaries etc |
| 14 | OD524585/2025-2026:Supply and fitting 50 mm Sluice valve on existing GI pipe with flanges etc |
| 15 | OD524627/2025-2026:Supply and fitting 2 \\" GI Coupling. |
| 16 | OD524571/2025-2026:Supply and providing NYLON ROPE MAXIMA LG14MM |
| 17 | OD524624/2025-2026:Supply and providing Cable Joint Tape etc. as required. |
| 18 | OD524625/2025-2026:Supply and providing Cotton waste etc. as required. |
| 19 | OD524626/2025-2026:Supply and providing Shellac 50 ml etc. as required. |
| 20 | 90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm |
| 21 | 1.17.32:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 6 sq. mm |
| 22 | 2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door |
| 23 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 24 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 25 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 26 | 5.1:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 27 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 28 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 29 | OD524620/2025-2026:Supply and providing 25x3mm brass nut and bolt etc. as required. |
| 30 | 90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point |
| 31 | OD524591/2025-2026:Supply, conveyance, installation, testing and commissioning of Bulk head light fittings with 7/9W LED bulb directly on wall including giving connections with required length of 16/0.20mm 3core round copper conductor flex wire conforming to relevant ISS making good the damages,colour washing etc as required. Please Enable Macros to View BoQ information |