| 1 | Cleaning jungle including uprooting of vegetation grass, bush, wood, trees and sapling of girth up to 30cm. Measured at a height of 1.00m above ground level & removal of rubbish upto a distance of 50.00 m outside the periphery of area. |
| 2 | Excavation in foundations in ordinary soil ( Loam clay or sand ) including lift up to 1.5 m and lead up to 30.o meter and including filling, watering and ramming of excavated earth in to the trenches or into the space between the building and the sides of foundation trenches or in to the plinth and removal and disposal of surplus earth as directed by the Engineer- in charges up to a distance of 30 m from the foundation trenches |
| 3 | Providing and laying PCC with cement, C Sand and 40 mm gauge stone ballast in 1:4:8 |
| 4 | Providing and laying cement concrete in 1:6:12(1 cement :6 Fine sand :12 Brick ballast 40mm gauge) |
| 5 | RCC Work with cement, approved coarse sand and 2 cm gauge approved stone grit in proportions of 1:1.5:3 in Raft foundation and Footing |
| 6 | RCC Work with cement, approved coarse sand and 2 cm gauge approved stone grit in proportions of 1:1.5:3 in Column or Wall |
| 7 | RCC Work with cement, approved coarse sand and 2 cm gauge approved stone grit in proportions of 1:1.5:3 in Beam |
| 8 | First class B/w in 1:4 Cement C'sand mortor in Sub Structure including supply of all meterial labour t&P etc required for proper completion of work |
| 9 | First class brick work in 1:4 cement and coarse sand mortar in Super Structure & Filling one brick thick including supply of all materials, labour and T & P etc. required for proper completion of work. |
| 10 | Washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of Engineer-in-charge (payment for providing grooves shall be made separately). |
| 11 | Providing and laying cement concrete in 4:2:1 of not less than strength of M-150 stone ballast (20 mm nominal size), approved coarse sand and cement, curing complete including of cost of form work in foundation and floors-completion of the work as per direction of the E / I. |
| 12 | Supply,Laying and Consolidation of 22.40-53 mm gauge stone Ballast |
| 13 | Supply and Laying of Rubber moulded C.C Interlocking Tiles 80mm thick in road pavement having a compressive strength not lass than 300 kg / cm2 including 40 mm thick bed of fine sand of F/M 1.25 |
| 14 | Apply two coat superior synthetic enamal paint including primer coat on steel surface |
| 15 | M.S. or iron work of small sizes and section such as holding down bolts, hold fast, tie rods grating etc. wrought to required from including supply of steel bolts, nuts wastage etc. and their fixing required for proper completion of the work |
| 16 | Earth work in filling with ordanry soil including lead up to 30 mtr and lift up to 1.5 mtr, including extra cartage up to 8.00 km |
| 17 | Preparation of mounds of various size and shape by available excavated /supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. |
| 18 | Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 16 mm cum |
| 19 | Rough dressing the trenched ground including breaking clods. |
| 20 | Fine dressing of the ground. |
| 21 | Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, as per direction of officer in charge |
| 22 | Supply and fixing Garden Bench (Victoria Type Bench) Cast iron having back height of 720mm and seating height of 390 mm. M.S tube of 65mm x 25mm rectangular tube having length of 1520 mm in 10 Nos. For seating purpose with extra support 25mm x 5mm M.S flat for extra stability all sharp and rough edge of bench are to be grinded with grinder and all fill up with m seal where its requires necessary thus bench is having the provision of hole past system(for grouting). Bench in complete with a coating of 1st class red oxide and with two coats of synthetic enamel of 1st class quality paint in green colour. Finally bench is assembled with nuts and bolts. Gross weight of each bench is 70kg. |
| 23 | Supply and Fixing inoguration black granite stone padestal including grooving matter, brick work, plaster, painting etc. all complete |
| 24 | GST 18 % Please Enable Macros to View BoQ information |