|
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. -All kinds of soil |
| 2 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level: 1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size |
| 4 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement--All work upto plinth level: 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 5 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement : In plinth and skirting courses, fillets, columns, pillars, posts and struts: 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stoneaggregate 20 mm nominal size) |
| 7 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 8 | Centering shuttering including struttings, propping etc. and removal of form work for: Lintels, beams, plinth beams, girders, bressumers andcantilevers with shuttering ply |
| 9 | Centering shuttering including struttings, propping etc. and removal of form work for: Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply |
| 10 | Centering shuttering including struttings, propping etc. and removal of form work for: Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering ply |
| 11 | First class brick work in foundation and plinth including cost of all materials as required complete:- In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 12 | Half brickmasonryworkwith first class bricks in foundationandplinthincludingcostofallmaterialsas required complete: In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 13 | 80 mm thick factory made c.c. interlocking paver block of M-35 Grade Providing and laying factory made chamfered edge CementConcrete paver blocks of required strength, thickness & size/ shape, made by table vibratory method to attain superior smooth finish using PU or equivalent moulds, laid in required grey colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks, lawns, drive ways or light traffic parking etc. all complete as per specifications & approval/ direction of the Engineer -in-Charge:(a) 80 mm thick c.c. paver block of M-35 grade with approved colour, design and pattern. |
| 14 | Providing and Installation of PVC Septic Tank as per direction of Engineer-in-Charge.3400 ltr |
| 15 | Providing and fixing aluminium work for doors,windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred andjointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawing and the direction of Engineerincharge.(Glazing and paneling and dash fasteners to be paid for separately) :- For fixed portion of approved quality:- Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). |
| 16 | Providing and fixing factory made UPVC door framemade of UPVC extruded, section having an overalldimension, as below (tolerance +/- 1mm) with wallthickness 2.0mm+/- 02mm. corners of the door frame to be jointed with galvanized brackets and stainless screws, joint mitred and plastic wilded. The hinge side vertical of the frames reinforced by galvanized MS tube of size 19 × 19 mm and 1 mm +/- 0.1 mm wall thickness and 3 nos stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-Charge.Extruded section Profile size 48x40 mm. |
| 17 | Providing and fixing to existing door frames. 24 mm thick factory made PVC door shutters made of styles and rails of a UPVC hollow section of size 59x24 mm and wall thickness 2 mm ± 0.2 mm with inbuilt edging on both sides. The styles and rails mitred and joined at the corners by means of M.S. galvanised /plastic brackets of size 75×220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserying galvanised MS tube of size 20×20 mm and 1 mm ± 0.1 mm wall thickness. The lock rail made up of \\"H\\" Section, a UPVC hollow section of size 100×24 mm and 2 mm ± 0.2 mm wall thickness fixed to the shutter styles by means of plastic /galvanised MS \\"U\\" cleats. The shutter framefilled with a UPVC multi-chambered single panel of size not less than 620 mm, having overall thickness of 20 mm and 1 mm ± 0.1 mm wall thickness. The panels filled vertically and tie bar at two places by insertinghorizontaly 6 mm galvanised MS rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-In-Charge. (for W.C. and Bathroom door shutter). |
| 18 | 12 mm cement plaster of mix Cement mortar 1:4 (1 cement : 4 fine sand) |
| 19 | 15 mm cement plaster on the rough side of single or half brick wall of mix: Cement mortar 1:4 (1 cement : 4 fine sand) |
| 20 | 6 mm cement plaster of mix : Cement mortar 1:4 (1 cement : 4 fine sand) |
| 21 | Neat cement punning. |
| 22 | Providing and fixing Precast chequered cement concrete tiles 18 mm thick, laid in footpath & courtyard, on 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with neat cement slurry including rubbing and cleaning etc. all complete as per direction of Engineer-in-charge. |
| 23 | Providing and fixing Marble stone in floors over 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with ordinary cement slurry including pointing with white cement mixed with of matching shade, including rubbing and polishing etc. all complete as per direction of Engineer-in-charge. 18 mm thick Marble stone Raj Nagar plain marble |
| 24 | Providing and fixing 1st class quality ceramic glazed wall tiles conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) of approved make in all colours, shades of any size as approved by Engineer-incharge in skirting, risers of steps and dados, laid over 12 mm thick bed of cement mortar 1 : 3 (1 cement : 3 fine sand) jointed with ordinary cement slurry includingpointing with white cement mixed with pigment ofmatching shade etc. all complete as per direction of the Engineer in-charge. 450 mm X 300 mm in all shades and design |
| 25 | 18 mm thick Granite of any colour and shadeduly approved:-Area of slab over 0.50 sqm. |
| 26 | Providing and fixing M.S. grills of required pattern inframes of windows etc. with M.S. flats, square orround bars etc. all complete. Fixed to steel windows by welding. |
| 27 | Providing structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as required. |
| 28 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 29 | Finishing walls with textured exterior paint of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : New work ( two or more coats applied @ 3.28 litre/10 sqm) over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm |
| 30 | Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade. [Payment shall be made after submission of Test Certificate issued by the Manufacturer] |
| 31 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 32 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 33 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required,proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of aluminium composite panel material of approved thickness and specification. The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bimetallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.\\" Aluminium Composite Panels of 4mm total thickness with Top coil – 0.50mm AA3003 / AA3105 / AA5005 Grade manufactured as per IS-737 1986, FR Grade Class B1 with 3mm Mineral Core with minimum 70-72% Inorganic content (Aluminium Hydroxide and MagnesiumHydroxide) 28-30% Organic content (LDPE) conforming to ASTM E-119-16,18 and EN 13501-1, class B1,and Bottom coil – 0.50mm AA3003 / AA3105 / AA5005 Grade, manufactured as per IS-737 1986 with minimum 25 microns lead free PVDF Coating conforming to AAMA2605 on top coil and Service coating on Back Coil (4 - 6 microns) having minimum panel weight of 7.5 Kg/m2. |
| 34 | Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 markedwith cover and suitable locking arrangement andmaking necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 35 | Providing and fixing white vitreous china pedestaltype water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushingcistern with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 36 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. |
| 37 | Providing and fixing ISI marked oxidised M.S. towerbolt black finish, (Barrel type) with necessary screws etc. complete : 250x10 mm |
| 38 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete 125 mm |
| 39 | Providing and fixing PTMT towel rail complete withbrackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour. 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms. |
| 40 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 41 | Providing and fixing PTMT bib cock of approvedquality and colour. 15mm nominal bore, 86 mm long, weighing not less than 88 gms. |
| 42 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32 mm dia |
| 43 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm dia |
| 44 | Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. |
| 45 | Providing and fixing Chlorinated PolyvinylChloride (CPVC) pipes, having thermal stability forhot & cold water supply including all CPVC plain &brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm nominal outer dia .Pipes. |
| 46 | Providing and fixing Chlorinated PolyvinylChloride (CPVC) pipes, having thermal stability forhot & cold water supply including all CPVC plain &brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. External work 20 mm nominal outer dia .Pipes. |
| 47 | Providing and fixing Chlorinated PolyvinylChloride (CPVC) pipes, having thermal stability forhot & cold water supply including all CPVC plain &brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal outer dia .Pipes. |
| 48 | Providing and fixing on wall face unplasticisedRigid PVC rain water pipes (working pressure 4kg/cm2) conforming to IS : 13592 Type A includingjointing with seal ring conforming to IS : 5382leaving 10 mm gap for thermal expansion etc.complete as per direction of Engineer-in-charge :Single socketed pipe - 110 mm OD |
| 49 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type-A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge :Coupler110 mm |
| 50 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required lengthincluding cutting brick work and fixing with cementmortar 1 : 4 (1cement : 4 fine sand) making good the wall etc. complete as per direction of Engineer-in-charge.110mm |
| 51 | Providing and fixing on wall face unplasticised Rigid PVC soil, waste & vent pipes (working pressure 4 kg / cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:Single socketed pipe - 110 mm OD |
| 52 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC soil, waste & vent pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:Coupler110 mm |
| 53 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC soil, waste & vent pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:Bend 87.5°110 mm |
| 54 | Treatment of soil under plinth filling using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with sand filling:With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. |
| 55 | Drilling and boring pilot hole in any soil strata by manual means, collection of soil samples of different strata met with during drilling at various suitable levels, preservation of samples in polythene bags / sample boxes and disposal of excess soil or mud, including the cost for water etc. as required to maintain the pilot hole properly as per specification and direction of the Engineer - in -charge |
| 56 | Reaming of pilot hole to an enlarged bore hole in any soil strata by manual means, disposal of excess soil or mud, including the cost for water etc. as required to maintain the bore hole properly as per specification and direction of the Engineer - in - charge. A. From 100 mm dia pilot hole to 250 mm bore hole (Drain) |
| 57 | Providing and fixing of UPVC end cap / well cap suitable for UPVC 'CM' casing or 'CS' casing or 'RS' pipes as per specification and direction of the Engineer - in - charge. i) 100 mm dia |
| 58 | Providing & lowering of UPVC pipe as per IS:12818 after washing of the bore hole by manual means as per specification and direction of the Engineer - in - charge. B) 'RS' pipe, i) 100 mm |
| 59 | Providing & lowering of UPVC pipe as per IS:12818 after washing of the bore hole by manual means as per specification and direction of the Engineer - in - charge. B) 'RS' pipe, i) 100 mm A) 'CM' casing pipe i. 100 mm dia |
| 60 | Providing & lowering of UPVC pipe as per IS:12818 after washing of the bore hole by manual means as per specification and direction of the Engineer - in - charge. B) 'RS' pipe, i) 100 mm A) 'CM' casing pipe i. 150 mm dia |
| 61 | Providing and fixing of UPVC reducer suitable for UPVC 'CM' casing or 'CS' casing or 'RS' pipes as per specification and direction of the Engineer - in - charge. ii. 150 x 100 mm dia |
| 62 | Washing and development of tube well by using hand pump or by any suitable method and testing of the well as per specification and direction of the Engineer - in - charge |
| 63 | Providing and Shrouding of the deep tube well assembly with washed pea gravels ( 2.0 - 4.75 mm effective size ) as per specification ( IS : 4097) using deep drilling rig and direction of the Engineer - in – charge. A. With contractor's high power rig i. With pea gravels obtained from Durgapur, West Bengal. |
| 64 | Fabrication of column pipe including providing & fitting fixing of G.I. flange by cutting the GI pipe into 3.05 mtrs. Size and welding the same with GI flange as per specification and direction of the Engineer-in-charge ( G.I. pipe will be issued by the Department at free of cost ).i) For 50 mm dia G.I. pipe with 10 mm thick GI flange |
| 65 | Providing and fitting fixing with PVC insulated 3 core flat Copper cable conforming to relevant IS code for submerssible motor with all necessary equipments and fittings as required as per specification and direction of the i) 2.50 sqmm |
| 66 | Providing and fitting fixing steel sheet enclosed switch fuse unit (suitable for DIN fuses), triple pole with Neutral Link (TPN), 415/500 Volt, L & T / Havells / BCH make etc.complete as per specification and direction of the Engineer in-charge. i) 32 amps |
| 67 | Supplying and installation of water lubricated submersible pump having ISI marked of capacity 2000 GPH at total head up to 60 mtr. Cuple with submersible motor 2HP suitable for 240 voltas(+10% variation single phase 50 HP .AC supply DOL starting method to run at 2880 RPM along with 35 mtr 2.5 sqm. PVC insulated 3 (Three) core Flate copper cables including fitting fixing and lowering if with 40 mm dia G.I Pipe up to 100 FT.(30.00 mtr) etc. complete as per direction of the Engineer-In-Charge.(40 mm dia G.I pipe and fitting will be paid separately) |
| 68 | Supplying and fitting fixing of MS box of having size 60 cm x 60 cm x 45 cm with slope roof and font shutter with locking arrangement fitted with 4 Nos 40 mm x 40 mmx 6 mm MS angle of 1.60 m long in/c providing & fitting wooden board inside the box having size 55 cm x 55 cm x 1'' thick for fitting all the electrical features like starter,main switch and in/c cost of necessary painting & embedding the box with CC block size 30 cm x 30 cm x 60 cm with 1:2:4 (1 Cement : 2 river Sand : 4 Jhama brick aggregate 20 mm gauge) as per direction of the Engg-in-charge.(Starter,Main switch will be paid separately). Please Enable Macros to View BoQ information |