| 1 | Servicing & cleaning of 1.5 TR window/ Split AC units by the cleaning agent / detergent i/c dismantling from window, cleaning / brushing and refixing in the same window etc complete as reqd. |
| 2 | S/charging of refrigerant gas for in the refrigerant circuit of existing SAC / WAC unit, vacumising and leak testing etc as reqd |
| 3 | Topup of refrigerant gas for in the refrigerant circuit of existing SAC unit, i/c leak testing etc as reqd |
| 4 | Replacement of faulty /defective 1.5 TR capacity compressor with new Sealed compressor i/c brazing & making necessary addition/alteration , testing commissioning etc as reqd.(M/s Emerson/Tecumseh/SS make) |
| 5 | Replacement of faulty outdoor motor of split AC unit 230 Volt 50 Hz A.C. supply i/c connection testing etc as reqd. |
| 6 | Replacement of faulty indoor motor of split AC unit 230 Volt 50 Hz A.C. supply i/c connection testing etc as reqd. |
| 7 | Supply and replacement of fan blade of outdoor unit in the exsting split AC units including dismantling of the damaged fan blade etc complete as required |
| 8 | supply and Replacement of contactor in the outdoor unit of split AC units for 230 Volt 50 Hz i/c connections testing etc complete as reqd. |
| 9 | Rewinding of outdoor motor of split AC unit 230 Volt 50 Hz A.C. supply i/c dismantling, oiling, replacement of bush and reconnection testing etc as reqd. |
| 10 | Repairing of PCB of indoor unit of 1.5 TR split AC units 230 Volt 50 Hz A.C. supply i/c dismantling of the burnt PCB including connection testing etc as reqd. |
| 11 | Replacement of faulty PCB assembly in existing split AC units i/c testing, commissioning etc., complete as required. |
| 12 | S/F of DP sheet steel enclosure on surface/ recess alongwith 25/32 A 240 volt C curve DP MCB complete with connection, testing and commissioning etc. as reqd. |
| 13 | Dismantling of the existing split AC units i/c dismantling of outdoor units etc complete as required |
| 14 | Transportation of split AC unit with complete accessories i/c loading & unloading up to 25km in Lucknow. |
| 15 | I.T.C. of 1.5 TR split AC unit i/c fixing of copper tubes covered with foam insulation in PVC flexible pipe, bending, brazing and leakage testing, laying/fixing of exisitng copper conductor cable, drain piping laying work etc. complete as required. |
| 16 | Supply and fixing of Heavy Duty Powder coated M.S. Stand for outdoor unit of 1.5TR split |
| 17 | S/f copper pipe line both 1/4\\" for gas line and 5/8\\" for liquid line OR suitable dia along with suitable size rubber foam on surface of the wall i/c necessary flare nuts, suitably brazing etc. complete as required. |
| 18 | Supply and fixing of 3x2.5 sq mm size of pcv insulated copper conductor flexible cable. |
| 19 | Providing technician for site visit / inspection during the nominal issues like water leakage etc as required for various sites on call basis etc as required. |
| 20 | Replacement of following faulty items i/c connections, testing etc. complete as required.(a) 16 to 32 Amp DP MCB |
| 21 | b) 16/20/32 Amp. SP MCB 'C' series |
| 22 | Replacement of faulty damaged PCB Control card of 1.5 TR inverter type AC unit for I/D unit in existing window / split AC units including removal of faulty spares, supplying and fixing new one testing, commissioning etc., complete as required. |
| 23 | Replacement of faulty damaged PCB Control card of 1.5 TR inverter type AC unit for O/D unit in existing window / split AC units including removal of faulty spares, supplying and fixing new one testing, commissioning etc., complete as required. |
| 24 | Replacement of choked / faulty 20 mm dia PVC drain pipe in recess or on surface for drainage of split AC units i/c connections etc complete as reqd. |
| 25 | Replacement of faulty 50mfd running capacitor with new one for split / window type AC unit complete as required |
| 26 | Replacement of faulty damaged Blower in existing split AC units including removal of faulty spares, testing, commissioning etc., complete as required. |
| 27 | Pdg & fixing of air conditioning automatoc changeover timer switch suitable for 02 nos AC units with inbuilt micro controller etc wall mounted type auto/ manual i/c connection testing etc as reqd. Please Enable Macros to View BoQ information |