| 1 | Taking down carefully ceiling fan, exhaust fan, wall / pedestal fan of any make and any sweep and dismentaling of blades canopy down rod etc & remove to store for repair. & Refix the same including provision of 3 core 0.5 sq mm copper flexiable cable from ceiling rose to connector.Note (i) The representative (01 Supervisor, 2 Electrician & 2 Helper) of the contrcator shall report to Engineer-in-charge/JE on daily basis to carry out repairs to fan and the defects should be rectified on the same day & if Accn is found Locked contractor shall manpower next day.If contractor fails to deploy stipulated manpower for two consecutive working days that a panel recovery of 1000Rs per day shall be recovered from contractor from first day of absent. (ii) Spares such as Bearing, Capacitor, Capacitor Clamp, Rubber insulator will be measured seperately under respective item of this schedule as fixing only.(iii) Rewinding required will be measured and Paid Seperately. |
| 2 | M&L for Opening of body cleaning of slots, Rewinding of fan by super ennameled copper insulated wire as per existing gauge, varnishing, heating assembling and testing complete, including overhauling all as directed by Engineer-in-Charge. Note - Spares such as Bearing, Capacitor, bush, Shaft, Capacitor Clamp, Rubber insulator will be measured seperately under respective item of this schedule as fixing only |
| 3 | Ceiling fan 1200 / 1400 mm Sweep. |
| 4 | Exhaust Fan,Pedestal fan,wall fan, table fan 300/400 mm Sweep. |
| 5 | Exhaust Fan, Pedastal fan,wall fan, 450/600 mm Sweep. |
| 6 | Painting only of ceiling fan,exhaust fan,wall fan,pedestal fan for any size and type, sscraping out of old paint filling of cavities with filler preparation of body and cleaning of dust etc Painting by Spray with first Quality Paint including undercoat of zinc primer, writing of Mes number with red colour complete for all as directed :- |
| 7 | Overhauling of Ceiling Fan, Exhaust Fan, Wall Fan,Table fan,Pedestal Fan any Make & any Sweep including dismantling/opening of body, cleaning of body, oiling, greasing & reassembling complete, replacing of split pin, nut , bolts etc and testing Note - Spares such as Bearing, Capacitor, bush, Shaft, Capacitor Clamp, Rubber insulator will be measured seperately under respective item of this schedule as fixing only |
| 8 | Supply only spare parts to be incorporated for repairing fans taken down vide item no 1 in respective item of this schedule |
| 9 | Capacitor up to 2.5 micro fd |
| 10 | Capacitor 3.15/ 4 micro fd |
| 11 | Capacitor Clamp with Connector As Par Sample |
| 12 | Rubber Insulator sutiable for any type of Ceiling Fan. |
| 13 | Mild steel Down Rod 600 mm Long with Clamp nut bolts & split pin as par sample |
| 14 | Mild steel Down Rod with Clamp nut bolts& split pin for 900 mm Long as par sample |
| 15 | Exhaust Fan bracket with frame Nut, Bolt, Rubbers etc mplete 300 mm sweepas par sample |
| 16 | Exhaust Fan bracket with frame Nut, Bolt, Rubbers etc complete380/ 450 mm sweepas par sample |
| 17 | Ball bearing sutiable for any type of fans |
| 18 | Gun Metal bush as per sample sutiable for any type of fans |
| 19 | Mild steel shaft as per sample for any fan |
| 20 | Ceiling Fan Blade suitable for 1200/1400 mm sweep as per sample. |
| 21 | Exhaust Fan Blade suitable for 300 mm sweep as per sample. |
| 22 | Exhaust Fan Blade suitable for 450 mm sweep as per sample. |
| 23 | Pedestal/Wall Fan Blade suitable for 450 mm sweep as per sample. |
| 24 | Pedestal / Wall Fan Blade suitable for 600 mm sweep as per sample. |
| 25 | Supply and fixing in replacement ofCapacitor up to 2.5 micro fd for ceiling/wall/pedestal fan including opening of canopy/cover in hanging position and replacing the capacitor, testing complete all as directed |
| 26 | Supply and fixing in replacement of Capacitor up to 3.5/4 micro fd for ceiling/wall/pedestal fan including opening of canopy/cover in hanging position and replacing the capacitor all as directed |
| 27 | Supply & Fix in replacement of Exhaust fan louvers ( Suitable for any size of exhaust fan upto 600 mm)with shutter made of aluminium sheet of 0.5 mm thickness, and frames made out of mild steel, making good the distrubed surfaces in CM 1:4, including scafolding if any required to carry out the work in building of height up to 12Meters complete in all respects the |
| 28 | M & L for Opening switch board mounting plate at height upto 1.5m and replacing of old unserviceable piano switch 5 Amps & refixing switch plate and testing complete all as directed.Note (i) The representative of the contrcator shall report to Engineer-in-charge/JE and carry out repairs on daily basis be rectified on the same day and if accomodation found locked contractor shall visit again for rectification of complaint |
| 29 | M & L for Opening switch board mounting plate at height upto 1.5m and supply and replacing of old unserviceable fan regulator socket type & refixing switch plate and testing complete all as directed.Note (i) The representative of the contrcator shall report to Engineer-in-charge/JE and carry out repairs on daily basis be rectified on the same day and if accomodation found locked contractor shall visit again for rectification of complaint |
| 30 | M & L for taking down of existing PVC/ Bakelite of size 65 mm x 50 mm ceiling rose and replacing ISI Marked celing rose 3 terminal 230 Volts Note (i) The representative of the contrcator shall report to Engineer-in-charge/JE and carry out repairs on daily basis be rectified on the same day and if accomodation found locked contractor shall visit again for rectification of complaint |
| 31 | M & L taking down from position existing defective storage water heater 25 to 50 ltre storage Capacity for carrying out repairs work such as replacing worn out parts and fixing back in position in replacing the necessary nuts and bolts including disconnecting & reconnecting water & electric supply lines, testing, painting with two coats of white synthetic enameled paint by spray paint complete all as specified and directed |
| 32 | Supply only safety valve for geyser chromium plated brass 15 mm dia all as specified and directed |
| 33 | Supply only non return valve chromium plated brass 15 mm dia heavy-duty all as specified and directed |
| 34 | Supply only indicator lamp for geyser red/green, round/square/rectangle as per site requirement 230 V AC all as specified and directed |
| 35 | Supply only heating element 1500 watt threaded or push type as per the existing one suitable for vertical storage water heater of any size all as specified and directed |
| 36 | Supply only heating element 2000 watt threaded or push type as per the existing one suitable for vertical storage water heater all as specified and directed |
| 37 | Supply only thermostat suitable for storage water heaters 25 to 50 Ltrs capacity adjustable type i.e.. 0 degree centigrade to 80 degree centigrade all as specified and directed |
| 38 | Supply only thermostat assembly along with relay suitable for heater 25 liters 5 star rated all as specified and directed |
| 39 | Supply and fix only plug top 3 pin 15/16 Amps capacity , ISI Marked |
| 40 | Supply and fix in repairs cable flexible 3 core PVC insulated and pvc sheathed with multi stranded copper conductor size of 2.5 sqmm 1100 volts grade all as specified and directed. |
| 41 | Fabricating, supply and fixing in replacement geyser bottom cover duly painted in two halves suitable for vertical type storage water 25/50 Ltrs capacity for geysers of any make as per the existing one all as specified and directed |
| 42 | Supply & Fix in replacement flexible 15 mm dia PVC pipe for cold water of geyser with PTMT nuts on both ends of length 450mm with two washers, all as specified and directed |
| 43 | Supply & Fix in replacement flexible 15 mm dia PVC pipe for hot water of geyser with PTMT nuts on both ends of length 450mm with two washers, all as specified and directed |
| 44 | Supply and fixing in repairs Sheet Metal enclosure with 2 pin and earth plug and socket complete with one single pole MCB SP of Capacity 20 Amps 240 Volts |
| 45 | Supply and fixing in repairs Metal clad plug top with 2 pin and earth plug complete of Capacity 20 Amps 240 Volts |
| 46 | Supply and fixing in repairs Metal clad socket complete ISI Marked of rating 20 Amps 240 Volts complete as directed. |
| 47 | M&L for taking down unsv BLDC ceiling fan from original position, finding out defective part/fault and repair of any unsv part of BLDC fan complete including rewinding, AC -DC convertor etc and testing, refixing at original positioncomplete all as specified and directed. |
| 48 | S&F in replacement of U clamp suitable for any type of ceiling fan incl rubber reel complete all as specified and directed. |
| 49 | S&F in replacement of Geyser appartus assembly suitable for 25/ 50 ltr gyser of any make and type complete all specified and directed. Please Enable Macros to View BoQ information |