| 1 | (a) Cleaning of clearing of blocked IWCs & EWCs to sewage line upto 1st manholes by rodding or any other suitable method & taking out the muck, mud and other debris from WCs and the sewage line cleaning with fresh water & removing the debris upto a distance exceeding 1.50km (out of defence land and disposed off by own arrangement by contractor). (b)Cleaning of clearing of blocked/ chocked/ floor trap in kitchen & bathrooms including gully trap, the waste water line connection etc by rodding or by any other suitable method & taking out the debris to a distance exceeding 1.50km (out of defence land and disposed off by own arrangement by contractor) and drain out the floors taps, gully traps waste pipe and soil pipe with fresh water etc complete all as directed by Engineer-in-Charge.Note:- The contractor shall deploysufficient Number of labour and at least one supervisor to collect complaint slips each day from complaint cell. (Note : Complaint shall be cleared in daily basis unattended complaint shall a recovery of Rs 100.00 per complaint. |
| 2 | M & L for Removal of blockage of sewage lines up to 150mm dia including manholes by using necessary tools/mechanicall tools or manually such as passing rope knots bamboo kamti and disc of required size including safety measures such as test for gas etc before flushing the pipe with water after removal of blockage including disposing off the removed sludge , etc to a distance n.exc 200m, burried under ground (minimum 30cm below ground level) including necessary excavation of pits in hard dense soil and returning, filling. |
| 3 | M & L for Removal of blockage of sewage lines exc 200mm dia including manholes by using necessary tools/mechanically tools or manually such as passing rope knots bamboo kamti and disc of required size including safety measures such as test for gas etc before flushing the pipe well with water after removal of blockage and including disposing off the deposited sludge , etc inside pipes to a distance n.exc 200m, burried under ground (minimum 30cm below ground level) including necessary excavation of pits in hard dense soil and returning, filling. |
| 4 | M & L for Removal of blockage of sewage lines of dia 300mm dia including manholes by using necessary tools/mechanically tools or manually such as passing rope knots bamboo kamti and disc of required size including safety measures such as test for gas etc before flushing the pipe well with water after removal of blockage and including disposing off the deposited sludge , etc inside pipes to a distance n.exc 200m, burried under ground (minimum 30cm below ground level) including necessary excavation of pits in hard dense soil and returning, filling. |
| 5 | Note for ser item No 1 to 4:- (i) The rates quoted in the items includes cost of T&P like rods, bamboos, gum shoes and hand glouses etc complete(ii) Minimum one sweeper and one helper shall be deployed by contractor and they shall be present on all days from 0900 hrs to 1700 hrs. The complaint shall be detailed by JE concerned every morning for attending complaints on daily basis.(iii) The complaint has to be rectified within 24 Hrs as given in complaint slip failing which penalty will be imposed @ 100/- per complaint per day and for ser no (ii) also. |
| 6 | M & L for Cleaning of sewer lines by mechanically by truck mounted sewage cleaning system comprising of water sludge tank with wash down system / suck derrick arm hydraulically spring loaded rotary sliding vane compressor with V hose end section no 33 nozzle and strainer all as specified and as directed. |
| 7 | Taking out silt brick bats, debris , liquid waste sludge in solid/semi solid state from manholes including use of saftey belts, dry cells torch for lighting inside the manholes and taking necessary precautionary measures and removing the sludge dispose off ( outside of defence land and own arrangement by contractor) & leveling the manhole cleaned and flushed with water etc all as specified /directed manholes up to the depth of 1.00 mtr. |
| 8 | Taking out silt brick bats, debris , liquid waste sludge in solid/semi solid state from manholes including use of saftey belts, dry cells torch for lighting inside the manholes and taking necessary precautionary measures and removing the sludge dispose off ( outside of defence land and own arrangement by contractor) & leveling the manhole cleaned and flushed with water etc all as specified /directed manholes up to the depth of exc 1.00 mtr. but n exc 2.00mtr |
| 9 | Supply and Fixing factory made cement concrete FRP manhole cover (1200mm X 600mm X 50mm) all as specified and directed by E-in-Charge |
| 10 | Supply and Fixing factory made cement concrete FRP manhole cover (900mm X 600mm X 50mm) all as specified and directed by E-in-Charge |
| 11 | Supply and Fixing factory made cement concrete FRP manhole cover (600mm X 600mm X 50mm) all as specified and directed by E-in-Charge |
| 12 | Supply and Fixing factory made cement concrete FRP manhole cover (300mm X 300mm X 50mm) all as specified and directed by E-in-Charge |
| 13 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. nexc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense soil all as specified and as directed. |
| 14 | Returning, filling in the any type of soil including spreading, levelling. Watering and well ramming in layers not exceeding 25cm thick each layer complete all as specified and directed. |
| 15 | Removing excavated soil material exc. 1.50 km but n exc. 5 km and depositing where directed |
| 16 | Demolition of Brick/precast concrete block/Stone/boulder masonary walling built in cement mortar all as specified and directed. |
| 17 | M&L pre-cast cement concrete(20mm graded crushed stone aggregate) 1:3:6 type C-1 as in block masonery exc 10cm in width with solid block masonery with solid blocks,exc.10cm in width and setting in cement mortar 1:4 all as specified and as directed. |
| 18 | Taking down cement plaster on brick or concrete surfaces including racking out joints hacking for key, scrubbing down with water etc. complete all as specified and as directed |
| 19 | M&L for 15 mm thick rendering on brick work/block masonary surface finished even and fair without using extra cement in cement mortar 1: 4 complete all as specified and as directed |
| 20 | M&L for preperation of new plastered wall surface of any description and applyng two coat of cement based paint over a coat of chalk whiting complete all as specified and as directed. |
| 21 | Demolition of concrete of any description and in any position not otherwise specifically provided for all as specified and as directed. |
| 22 | M&L for PCC 1:4:8 type, D2 (40mm graded stone agg.) as in foundation filling and mass concrete all as specified and as directed. |
| 23 | M & L for PCC 1:3:6 type C1 using 20mm graded stone aggregate as in coping, haunching and surface channel including necessary form work. |
| 24 | Demolition and breaking up of drain pipes (salt glazed ware or AC or reinforced cement concrete) set in cement mortar of 150/160mm dia complete all as specified and as directed by the Engineer-in-Charge |
| 25 | M&L for Reinforced concrete pipes, class NP2, 150mm dia laid in trenches and jointed complete with collars all as specified and directed |
| 26 | M&L for cement concrete D-2 (1:4:8) for 150mm pipe bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in complete all as specified and directed. |
| 27 | Demolition and breaking up of drain pipes (salt glazed ware or AC or reinforced cement concrete) set in cement mortar of 200/225mm dia complete all as specified and as directed by the Engineer-in-Charge |
| 28 | M&L for Reinforced concrete pipes, class NP2, 200mm dia laid in trenches and jointed complete with collars all as specified and directed |
| 29 | M&L for cement concrete D-2 (1:4:8) for 200 mm pipe bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in complete all as specified and directed. |
| 30 | Dismantling of CI/PVC drain pipes 50 to 110 mm all as specified and directed. |
| 31 | S&F 110mm bore PVC (SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 32 | S&F 110mm PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to wall incl cutting holes and make in good PCC type B-0, 1:2:4 (using 12.50mm graded agg) incl taking down existing pipes including necessary scaffolding, trestles, ladders, cradles etc upto 12M height for necessary for execution of work and protective measures all as specified and directed. |
| 33 | S&F 110mm dia PVC (SWR) pipes Stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof all as specified and directed. |
| 34 | S&F 75 mm bore PVC (SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 35 | S&F 75 mm PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to wall incl cutting holes and make in good PCC type B-0, 1:2:4 (using 12.50mm graded agg) incl necessary scaffolding, trestles, ladders, cradles etc upto 12 M height for necessary for execution of work and protective measures all as specified and directed. |
| 36 | S&F 75 mm dia PVC (SWR) pipes Stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof all as specified and directed. |
| 37 | S&F in repair 110mm bore PVC (SWR) bends any radius with acess door complete all as specified and directed. |
| 38 | S&F in repair 75 mm bore PVC (SWR) bends any radius with acess door complete all as specified and directed. |
| 39 | S&F in repair 110mm bore PVC (SWR) branch piece, single T with access door equal or unequal complete all as specified and directed. |
| 40 | S&F in repair PVC (SWR) Reducers all as specified and directed. |
| 41 | S&F in repair 75mm bore PVC (SWR) branch piece, single T with acess door equal or unequal complete all as specified and directed. |
| 42 | S&F in repair PVC (SWR) Vent cowl all as specified and directed. |
| 43 | S & F PVC (SWR) gully trap 110 mm dia fixed in cement concrete including removal of existing old damaged gully traps and providing connection upto 1st manhole with PVC pipe complete all as specified and directed. |
| 44 | S & F in repairs SS Grating doom 100mm dia including bedding and pointing in cement mortar 1:3 all as specified and directed. |
| 45 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and directed. |
| 46 | M&L 25mm thick cement concrete type B-0, 1:2:4 (12.50 mm gradedaggregate) as in sub-base of floor tiles all as specified and directed. |
| 47 | M&L for coloured Non skid ceramic tiles of size 300x300mmx7mm thick in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 15mm thick screed bed in CM (1:6) all as specified and directed. |
| 48 | Supply and fix Vitreous china Squatting pan Orissa pattern of size 580mx440mm wite with integral foot rests (excluding flushing cistern and flush pipe) complete including concrete bedding in repairs all as specified and directed. |
| 49 | S & F in repair PVC low level flushing system plastic valve with inlet ball valve float chain and ball (of capacity 10 liters) ISI Marked incl 32mm PVC flush pipe complete all as specified and directed |
| 50 | S&F in repairs PVC connection pipe suitable for connecting flushing cistern and WHB etc 450mm long complete all as specified and directed. |
| 51 | S&F vitreous China bowl urinal flat back size 465 X365 X 265mm white (minimum) withgrating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe complete including providing and fixing plugs bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement fixed in repairs complete all as specified and directed Please Enable Macros to View BoQ information |