| 1 | Supply of Equipment and Accessories |
| 2 | 33kV,1250A, Gang operated Vacuum Circuit Breaker with mounting structures and all accessories including all termianl connectors (Control Voltage: 220KV DC) |
| 3 | 33 kV, 31.5 kA for 3 sec, 1250 A motorised Isolators with Earth Switch complete with all fittings and accessories including terminal connectors |
| 4 | 33 kV, 31.5 kA for 3 sec, 1250 A motorised Isolators without Earth Switch complete with all fittings and accessories including terminal connectors |
| 5 | 33 kV, 400-200/1-1 A , 2 -core single phase CT complete with all fitting and accessories including terminal connectors, CT JB (0.2S class , live tank type) |
| 6 | 33 KV Lightning Arrester with surge monitor complete with all fittings and accessories including terminal connectors |
| 7 | 33 kv Post insulator with all fitting including terminal connectors |
| 8 | Mounting structures with all fittings, nuts & bolts including foundation bolts as per approved drawing |
| 9 | 33 kV motorized Isolator without Earth Switch suitable for supplied isolator |
| 10 | 33 Kv motorized Isolator with Earth Switch suitable for supplied isolator |
| 11 | 33 kv CT |
| 12 | 33KV LA |
| 13 | 33KV PI |
| 14 | CRP & BCU |
| 15 | Supply of 33 kV Feeder Control & Relay panels with BCU ( Simplex type) suitable for integration into the exsiting SAS (SIEMENS)(control voltage is 220V DC) |
| 16 | Managed Ethernet Switch with OF PATCH cable |
| 17 | ABT compliant Energy meter conforming SAMAST scheme as per specification including installation |
| 18 | Supply of Armoured Control cable (Copper) |
| 19 | 4C, 2.5 sq.mm |
| 20 | 7C, 1.5 sq.mm |
| 21 | 12C × 1.5 sq.mm |
| 22 | LED light for swichyard illumination including fitting and fixing |
| 23 | Supply of ACSR Zebra Conductor |
| 24 | Insulator strings, clamps & connectors |
| 25 | Double tension disc insulator (90 KN) string with hardware fitting for twin ACSR zebra and required termination clamps |
| 26 | Single suspension disc insulator (90 KN ) string with hardware fitting for twin ACSR zebra |
| 27 | Spacer suitable for ACSR twin zebra |
| 28 | T-Clamps ( Zebra to Zebra ) |
| 29 | UPG clamps ( zebra to zebra) |
| 30 | Earth mat Extension and associated earthing of equipments |
| 31 | 65 x 12 mm GI Flat for main earth mat |
| 32 | 50 x 6 mm GI Flat for eathing of Control Panels, junction box, marshalling box etc. |
| 33 | 40 mm dia 3mtr. long MS rod earth electrode (driven) with test links for each tower with peak and LA, switchyard earthing etc |
| 34 | 100 mm dia 3 mtrs long GI pipe electrode with test link |
| 35 | Switchyard Structure |
| 36 | Column type C5/C7 |
| 37 | Beam Type - B5/B6 |
| 38 | Supply of AC marshalling Kiosk including construction of foundation as required installation work i)2no 63A,4P(incomer)ii)3no 25A,4P(outgoing)iii)8no,16A,4P(outgoing)iv)8no,10A,4P(outgoing)v)5no,10A,2P(outgoing) |
| 39 | Supply of Fire Fighting Equipments |
| 40 | 22.5Kg Capacity FE CO2 type, trolley mounted |
| 41 | FE DCP 5 Kg capacity, wall mounted |
| 42 | Fire Buckets (12 Nos. with stand in one set) |
| 43 | Aluminium binding Tape |
| 44 | Manadatory Spares |
| 45 | Closing Coil for 33kV VCB ( 220 V DC) |
| 46 | Tripping Coil for 33kV VCB( 220 V DC) |
| 47 | Spring charging motor for 33kV VCB(as supplied) |
| 48 | CB operating mechanism for 33kV VCB |
| 49 | Set of all gaskets for 33kV VCB |
| 50 | Pole for 33kV VCB suitable to fit in all the phases of CB(as supplied) |
| 51 | 33 kV, 31.5 kA for 3 sec, 1250 A motorised Isolators fixed contact (Entire Assembly) |
| 52 | 33 kV, 31.5 kA for 3 sec, 1250 A motorised Isolators moving contact (Entire Assembly) |
| 53 | 33 kV CT 400-200/1-1 A (class : 0.2S) |
| 54 | 33 kV LA with surge counter and all accessories |
| 55 | Numerical back up relay (compatible for the already supplied CRP) |
| 56 | Bay Control Unit (compatible for the already supplied CRP) |
| 57 | Master Trip Relay (compatible for the already supplied CRP) |
| 58 | OFC Patch cord ST-LC |
| 59 | OFC Patch cord ST-ST |
| 60 | 33 kV Isolator clamp Single Zebra |
| 61 | 33kV CB clamp single ACSR Zebra |
| 62 | 33kV CT clamp for Single Zebra |
| 63 | Post Insulator clamp (Single ACSR Zebra) |
| 64 | Supply of Equipment and Accessories |
| 65 | 33kV,1250A, Gang operated Vacuum Circuit Breaker with mounting structures and all accessories including all termianl connectors (Control Voltage: 220KV DC) |
| 66 | 33 kV, 31.5 kA for 3 sec, 1250 A motorised Isolators with Earth Switch complete with all fittings and accessories including terminal connectors |
| 67 | 33 kV, 31.5 kA for 3 sec, 1250 A motorised Isolators without Earth Switch complete with all fittings and accessories including terminal connectors |
| 68 | 33 kV, 400-200/1-1 A , 2 -core single phase CT complete with all fitting and accessories including terminal connectors, CT JB (0.2S class , live tank type) |
| 69 | 33 KV Lightning Arrester with surge monitor complete with all fittings and accessories including terminal connectors |
| 70 | 33 kv Post insulator with all fitting including terminal connectors |
| 71 | Mounting structures with all fittings, nuts & bolts including foundation bolts as per approved drawing |
| 72 | 33 kV motorized Isolator without Earth Switch suitable for supplied isolator |
| 73 | 33 Kv motorized Isolator with Earth Switch suitable for supplied isolator |
| 74 | 33 kv CT |
| 75 | 33KV LA |
| 76 | 33KV PI |
| 77 | CRP & BCU |
| 78 | Supply of 33 kV Feeder Control & Relay panels with BCU ( Simplex type) suitable for integration into the exsiting SAS (SIEMENS)(control voltage is 220V DC) |
| 79 | Managed Ethernet Switch with OF PATCH cable |
| 80 | ABT compliant Energy meter conforming SAMAST scheme as per specification including installation |
| 81 | Supply of Armoured Control cable (Copper) |
| 82 | 4C, 2.5 sq.mm |
| 83 | 7C, 1.5 sq.mm |
| 84 | 12C × 1.5 sq.mm |
| 85 | LED light for swichyard illumination including fitting and fixing |
| 86 | Supply of ACSR Zebra Conductor |
| 87 | Insulator strings, clamps & connectors |
| 88 | Double tension disc insulator (90 KN) string with hardware fitting for twin ACSR zebra and required termination clamps |
| 89 | Single suspension disc insulator (90 KN ) string with hardware fitting for twin ACSR zebra |
| 90 | Spacer suitable for ACSR twin zebra |
| 91 | T-Clamps ( Zebra to Zebra ) |
| 92 | UPG clamps ( zebra to zebra) |
| 93 | Earth mat Extension and associated earthing of equipments |
| 94 | 65 x 12 mm GI Flat for main earth mat |
| 95 | 50 x 6 mm GI Flat for eathing of Control Panels, junction box, marshalling box etc. |
| 96 | 40 mm dia 3mtr. long MS rod earth electrode (driven) with test links for each tower with peak and LA, switchyard earthing etc |
| 97 | 100 mm dia 3 mtrs long GI pipe electrode with test link |
| 98 | Switchyard Structure |
| 99 | Column type C5/C7 |
| 100 | Beam Type - B5/B6 |
| 101 | Supply of AC marshalling Kiosk including construction of foundation as required installation work i)2no 63A,4P(incomer)ii)3no 25A,4P(outgoing)iii)8no,16A,4P(outgoing)iv)8no,10A,4P(outgoing)v)5no,10A,2P(outgoing) |
| 102 | Supply of Fire Fighting Equipments |
| 103 | 22.5Kg Capacity FE CO2 type, trolley mounted |
| 104 | FE DCP 5 Kg capacity, wall mounted |
| 105 | Fire Buckets (12 Nos. with stand in one set) |
| 106 | Aluminium binding Tape |
| 107 | Manadatory Spares |
| 108 | Closing Coil for 33kV VCB ( 220 V DC) |
| 109 | Tripping Coil for 33kV VCB( 220 V DC) |
| 110 | Spring charging motor for 33kV VCB(as supplied) |
| 111 | CB operating mechanism for 33kV VCB |
| 112 | Set of all gaskets for 33kV VCB |
| 113 | Pole for 33kV VCB suitable to fit in all the phases of CB(as supplied) |
| 114 | 33 kV, 31.5 kA for 3 sec, 1250 A motorised Isolators fixed contact (Entire Assembly) |
| 115 | 33 kV, 31.5 kA for 3 sec, 1250 A motorised Isolators moving contact (Entire Assembly) |
| 116 | 33 kV CT 400-200/1-1 A (class : 0.2S) |
| 117 | 33 kV LA with surge counter and all accessories |
| 118 | Numerical back up relay (compatible for the already supplied CRP) |
| 119 | Bay Control Unit (compatible for the already supplied CRP) |
| 120 | Master Trip Relay (compatible for the already supplied CRP) |
| 121 | OFC Patch cord ST-LC |
| 122 | OFC Patch cord ST-ST |
| 123 | 33 kV Isolator clamp Single Zebra |
| 124 | 33kV CB clamp single ACSR Zebra |
| 125 | 33kV CT clamp for Single Zebra |
| 126 | Post Insulator clamp (Single ACSR Zebra) |
| 127 | Erection of mounting structures as required including construction of foundation and supply of all foundation materials for different terimanl equipments as required for |
| 128 | 33kV Vacuum Circuit Breaker |
| 129 | 33kV CT |
| 130 | 33kV Isolator with Earth Switch |
| 131 | 33kV Isolator without Earth Switch |
| 132 | 33kV LA |
| 133 | 33kV Post Insulator |
| 134 | Erection, testing and commissioning including laying of cables (control & power) and all associated works and equipment and structure earthing as required |
| 135 | 33kV Vacuum Circuit Breaker |
| 136 | 33kV CT |
| 137 | 33kV Isolator with Earth Switch |
| 138 | 33kV Isolator without Earth Switch |
| 139 | 33kV LA |
| 140 | 33kV Post Insulator |
| 141 | Installation, testing and commissioning of 33 kV feeder control and relay panel including integration to existing SAS (SIEMENS)( including laying of control & power cables and earthing work as required) |
| 142 | Installation of switchyard illumination lighting set including laying of power cables and necessary termination |
| 143 | Hoisting of insulator strings,stringing of conductor,all required termianation works including supply of disc insulator strings,clamps, connnectors etc as per the requirement for the whole scope of works |
| 144 | Installation of earthing system |
| 145 | Installation of main earth mat (65x12mm GI flat) and connection to riser including painting of welded joints with bitumen paint |
| 146 | Installation of 50x6mm GI flat for earthing of indoor LT & control panels, junction box, marshalling box, all structure and equipment etc. as per reuirement |
| 147 | Installation of 40mm dia 3m long MS rod earth electrode including necessary connections to risers/ earth mat etc. with preparation of covered earth pit |
| 148 | Installation of 100 mm dia 3 m long MS rod earth electrode including neceesary connection to rise/ earth mat etc |
| 149 | Construction of foundation for lattice steel column including supply of all foundation materials and labour |
| 150 | Column C5 |
| 151 | Column C7 |
| 152 | Erection of lattice steel columns & beams along with required earthing |
| 153 | Column C5 |
| 154 | Column C7 |
| 155 | Beam B5/B6 |
| 156 | Construction of covered cable trenches including supply of all foundation materials and labours as per approved drawing & specification |
| 157 | Type D |
| 158 | Providing 80 mm thick PCC base in prop 1:4:8 as per drawing & specifications including supply of all materials and labours |
| 159 | Providing 100 mm thick gravelling (prewashed or cleaned from mud)on the switchyard including leveling etc. and all associated works like site cleaning etc. as per directive of site engineer or approved drawing Please Enable Macros to View BoQ information |