| 1 | Demolition to cement concrete in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 2 | Demolition of concrete of any description and in any position not otherwise specially provided for complete all as specified and directed. |
| 3 | Demolition of reinforced concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for, removing rubbish off the premises etc complete all as directed. |
| 4 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as directed. |
| 5 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 6 | Dismantling old PGI/CGI sheeting of any gauge thickness, including Nainital. Sikkim or similar pattern roof/facia etc complete. |
| 7 | Taking down chowkhats or frame with shutters (without taking off shutters from the frame) not exceeding 1.50 Sqm each complete all as directed. |
| 8 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) each area exc 1.5 sqm nut n.exc 4Sqm all as specified and as directed. |
| 9 | Taking down cement plaster of any description on brick or stone walls/ceiling incl raking out joints hacking for key, scrubing down with water etc. |
| 10 | Hacking out of old broken glass any thickness size quality or description from metal frame including punching or drilling out old glazing pins. |
| 11 | Excavating in post holes (or similar holes) each n.exc 0.5 Cum getting out and removing surplus soil to a distance n exc 50m and making good surfaces in soft/loose soil complete all as specified and directed. |
| 12 | M&L for PCC (1:3:6), type C2 (using 40mm graded stone aggregates) as in surfaces channels and drains incl necessary formwork complete all as specified and directed. |
| 13 | M&L for pre cast cement concrete block masonry with solid blocks, exc. 10 cm in width and settting in cement mortar 1:6 type C1, (1:3:6) (using 20 mm graded stone aggregate) as per IS 383 complete all as specified and as directed. |
| 14 | M&L for RCC type B1 1:2:4 (using 20 mm graded stone aggregate) (Nominal mix) as in Slabs supported on walls, beams and columns in floors, roofs, landings, cover slab, balconies, canopies, deck slabs and in shelves and the like complete all as specified & as directed.NOTE : Re-inforcement shall be measured and paid separately. |
| 15 | Use and waste formwork to soffits of suspended slabs such as roof slab, floor slabs, landing covers, and similar works, for rough finished flat surfaces of concrete, thickness of slab not exc 200 mm, complete all as specified and directed. |
| 16 | M&L for 2nd class hard wood plain solid straight chowkats and frames wrought framed rebated on the solid rounded on chamfered put together with glue pinned and joints complete all as specified and directed. |
| 17 | S&F factory made 35 mm thick 2nd class hardwood plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed. |
| 18 | S&F 150mm long Aluminium, anodised, barrel tower bolts of extruded section complete |
| 19 | S&F Mild steel butt hinges, Medium grade, 100 mm size , complete all as specified and directed. |
| 20 | S&F 150mm long Aluminium handles, cast type, anodised complete. |
| 21 | S&F for 75mm hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws |
| 22 | S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde-E-165 complete all as specified and directed. |
| 23 | M&L mild steel bars 10 mm dia & over cut to length bent to shape required, including cracking, bending spirally to proper for columns, hooking end & binding with and inch mild steel wire not less than 0.9mm dia or securing with clips quality conforming to TMT bars complete all as specified and directed. |
| 24 | M&L for MS bars 5 mm dia and over upto and including 10 mm dia in stirrups cut to length, bent to shape required incl cranking bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire(annealed) not less than 0.9mm dia quality conforming to TMT bars complete all as specified and directed. |
| 25 | S&F rolled mild steel section sections any type as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, FE -290 Gde E-165, complete all as specified and as directed. |
| 26 | S&F in repairs gear operated type Steel rolling shutters 1mm thick, with bevel gear box and crank handle , as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated complete all as specified and directed. |
| 27 | S&F in repairs Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed. |
| 28 | S&F in repairs ball bearing for rolling shutter complete all as specified and directed. |
| 29 | S&F in repairs the unserviceable axle spring with rod including gear of any dia suitable for rolling shutters of any size as per existing all as specified and directed. |
| 30 | S&F for 0.50mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheets of any colour and any pattern as approved having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws as in roof complete all as specified and directed by the Engr-in-Charge. |
| 31 | S&F for 0.50mm thick pre-painted galvalume aluminium zinc coating GI based plain steel sheets of any colour having tensile strength of 550 Mpa as in ridges, valley, eaves, etc fixed with self tapping screws complete all as specified and directed. |
| 32 | M&L for 75mm thick PCC type C2 1:3:6 (using 40mm graded stone agg) as in plinth protection/Path/hardstanding finished the concrete surfaces even and smooth without using extra cement etc complete all as specified and directed. |
| 33 | M&L for prepolished, chequered cement concrete tiles of size 25cmx25cmx22mm thick, as in floors etc, over and including 15 mm thick screed bed or bedding layer in cement mortar (1:6) and set and jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and as directed. |
| 34 | M&L for 25 mm thick PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in sub base of floor complete all as specified and as directed. |
| 35 | M&L for Kota stone slab 18-20mm thick in floor laid over and including 20 mm thick screed bed or bedding layer of cement morter (1:6)and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing all as specified and directed. |
| 36 | M&L for rendering 20 mm thick on fair faces of external wall of brick work or stone surfaces in two layers (10mm thick each layer) in cement mortar in (1:4) using water proofing compound in top layer and finished even and smooth (without using extra lime or cement) complete all as specified and directed.Note: Water Proofing Compound measured and paid separately. |
| 37 | Supply only liquid Water Proofing Compound ISI marked of approved make complete all as specified and directed. |
| 38 | M&L for 15 mm thick rendering plaster on fair faces of conc faces/ brick wall faces of smooth without extra cement in CM 1:6 complete all as specified and as directed . |
| 39 | M&L for rendering 5mm thick in cement morter (1:3) on ceiling surfaces, finished even and smooth without using extra cement, complete all as specified and directed. |
| 40 | M&L for applying three coats of white wash on new plastered ceiling surface including preparation of new and previously untreated surfaces of ceiling all complete all as specified and directed . |
| 41 | M&L for applying two coats of white wash on old plastered ceiling surface incl complete removal of existing surfaces etc complete all as specified and directed. |
| 42 | M&L for applying two or more coats of 100% premium Acrylic emulsion paint having VOC less than 50 gm /litre and UV resistant as per IS 15489:2004 alkali and fungal resistant exterior paint of required shed(company depot tinted) with silicon additives1.43 lits/10 sqm over and including primer coat of exterior primer applied 0.90 litre/10 sqm over a coat of 1mm thick putty over new plastered surface to prepare the surface even and smooth complete all as specified and directed . |
| 43 | M&L for complete removal of existing treatment from walls and applying two or more coats of 100% premium Acrylic emulsion paint having VOC less than 50 gm /litre and UV resistant as per IS 15489:2004 alkali and fungal resistant exterior paint of required shed(company depot tinted) with silicon additives1.43 lits/10 sqm over and including primer coat of exterior primer applied 0.90 litre/10 sqm over a coat of 1mm thick putty over plastered surface to prepare the surface even and smooth complete all as specified and directed |
| 44 | M&L for preparation of new plastered surfaces of walls applying two coats of distemper, oil emulsion, white or tinted over new wall suface complete all as specified and directed. |
| 45 | M&L for preparation of complete removal of existing treatement on old plastered surfaces of walls applying two coats of distemper, oil emulsion, white or tinted over old wall surface complete all as specified and directed. |
| 46 | M&L for preparation of new plastered surfaces of walls applying two coats of distemper, oil emulsion, white or tinted over new wall suface on a coat wall care putty complete all as specified and directed. |
| 47 | S&F 3 mm thick sheet glass, ordinary quality and glazing with oil putty in squares n.exceeding 0.50sqm in each pane complete all as specified and directed. |
| 48 | M&L preparation of new or previously untreated wooden surfaces of any description over 10 cm width or grith and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed. |
| 49 | M&L for preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats synthetic enamal paint over one coat of red oxide primer complete all as specified and directed. |
| 50 | M&L for preparation of old steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat synthetic enamal paint complete all as specified and directed. |
| 51 | S&F 110mm bore, PVC (SWR) pipes, single socketed in any length with rubber ring joints, laid in trenches or under floors , fixed on walls with necessary clips complete all as specified and as directed. |
| 52 | S&F 110 mm bore PVC (SWR) bend of any radius for PVC (SWR) pipes, fixed to walls or fixed to steel gutter complete all as directed. |
| 53 | M&L for water proofing treatment on RCC roof etc. comprising with the following operation & as specified herein below:- (a)Taking down existing old tarfelt, bituminous compound including cleaning & removing debris to a distance exc 100 m n.exc.250m. (b) M&L 25 thick cement concrete type B0 1:2:4 (12.5 mm graded aggregate) finished even and smooth. (c) Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight). (d) M&L for 20 mm thick screed bed in cement mortar 1:4 finished even and smooth.(e) Preparing & cleaning of fully dried cement plastered surface. (f) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 liters per sqm conforming IS-3384. (g) A layer of APP based polymeric membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/sqm) shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. (h) One coat of aluminium paint over APP membrane @0.11Kg/Sqm.Note:- Prior to execution of the APP Membrane works, leak proof test shall be done by ponding water on roof slab to minimum depth of 25 mm. The entire roof slab shall be flooded with water for 48 hours. The necessary barrier shall be made to make feasible to stagnate water for 48 hours on roof slab. |
| 54 | S&F polished Stainless steel lead lined hospital doors with frame of standrad pettern in any colour including all necessary fittings complete all as specified and as directed. |
| 55 | E/M PORTIONExcavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying/repairs to pipe line and getting out in any soft soil complete all as specified and directed. |
| 56 | Removing surplus excavated soil not exceeding 50m and depositing where directed at level not exceeding 1.5m above starting point complete all as specified and directed. |
| 57 | Returning filling in with approved excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 58 | M&L for PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregates) as in foundation, filling and mass concrete complete all as specifed and directed. Please Enable Macros to View BoQ information |
| 59 | M&L for PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregates) as in foundation, filling and mass concrete complete all as specifed and directed. Please Enable Macros to View BoQ information |