| 1 | Identification and rectification of shunt or series fault in main or sub distribution panel in labs / building. |
| 2 | Minor fault |
| 3 | Major fault |
| 4 | Identification and rectification of shunt or series fault in 415 V, multi core cables of folowing sizes as per scope of work |
| 5 | 3.5/4 Core, size upto 25 Sqmm |
| 6 | 3.5/4 Core size above 120 Sq mm and upto up to 240 sqmm |
| 7 | 3.5/4 Core size above 240 sqmm and upto 400 sqmm |
| 8 | 3.5/4 Core size above 25 Sq mm and upto up to 120 sqmm |
| 9 | Identification and rectification of shunt or series fault in lighting or power circuit wiring in labs / building as per scope of work |
| 10 | Minor fault |
| 11 | Major fault |
| 12 | Supply and Installation of following Wiring Accessories as per the detailed specification (Refer Sec VI (MNC), Clause No.5). |
| 13 | 1 No 6A Switch on modular plate and termination of wires to the switches |
| 14 | 1 No16A Switch on modular plate and termination of wires to the switche |
| 15 | 1 No 6A 3 Pin shuttered type Socket on modular plate and termination of wires to the switches |
| 16 | 1 No 6/16A 3 Pin combined shuttered type Socket on modular plate and termination of wires to the switches |
| 17 | 2 Module Step type Fan regulator on modular plate and termination of wires to the switches |
| 18 | 1 No 20 Amp Motor starter Switch on modular plate and termination of wires to the switches |
| 19 | Supply and Installation of following general electrical items as per the detailed specification (Refer Sec VI (MNC), Clause No.5). |
| 20 | 3.0 mm thick white finish Hylam sheet covers for MS switch Boxes/ JBs of Sizes up to 400 x 400 mm as per the scope of work |
| 21 | Installation of the following items on M.S.frame work(Refer Sec VI (MNC), Clause No.6). |
| 22 | 63/100/200/315/400 Amps, 500 Volt, TPN Fuse Switch Unit. |
| 23 | 16/32/63 Amps, 500 Volt, TPN 4/8/12 Way Distribution Board |
| 24 | Installation of the following items in 415V switch boards.(Refer Sec VI (MNC), Clause No.6). |
| 25 | 63/100/125Amps,500Volt,TP/TPN SFU/Combination FSU |
| 26 | 250/315/400/ 630 Amps, 500Volt,TP/TPN SFU/Combination FSU |
| 27 | Removal of termination of armoured cables of following sizes from electrical equipment or reconnecting of removed termination |
| 28 | Sizes upto 4C X 25 sq.mm |
| 29 | Sizes above 4C X 25 sq.mm and upto 4C X 70 sq.mm |
| 30 | Clearing light jungle area, bulb weeds, grass including removal all unwanted plants, branches, twigs, wild growth etc.complete, and disposing the same 100 meters away manually or burning them without disturbing other areas etc., complete all as directed by the Engineer-in-Charge. Contractor must inform the Engineer-in-charge and prior permission shall be obtained from him for burning the wild growth. (Refer Sec VI (MNC), Clause No.7.3). |
| 31 | Supply and replacement of the following Metalclad Plug and Socket (Refer Sec VI (MNC), Clause No.12). |
| 32 | 230V, 20A, 2P+E Metalclad Plug and socket |
| 33 | 415V, 20A, 3P+E, Metalclad Plug and socket |
| 34 | Removal of various sizes of MS box / switch box from the wall / panel (Refer Sec VI (MNC), Clause No.19). |
| 35 | Removal of various sizes of surface mounted GI/ PVC Conduit from wall/column/beam and transportation to storage yard (Refer Sec VI (MNC), Clause No.19). |
| 36 | Removal of the following from 415Volts switch boards (Refer Sec VI (MNC), Clause No.19). |
| 37 | 63A/100A/125A, 500V, TP/TPN/SFU/ Combination SFU or 4/6/8/12 Way SPN DB or 4/8 WAY TPN DBs |
| 38 | 250A/315A/400 A, TP/TPN/SFU/ Combination SFU or 12 Way TPN DBs |
| 39 | Attending fuse off call in Power Points/ Power boards and minor faults in various Building / Laboratories (Refer Sec VI (MNC), Clause No.22). |
| 40 | Disconnection of service connection with Energy meter board & shifting the board including connected cable. (Refer Sec VI (MNC), Clause No.27). |
| 41 | Installation of Energy meter board & providing service connection at Various locations .(Refer Sec VI (MNC), Clause No.29). |
| 42 | Installation of Energy meter board & providing service connection at Various locations. |
| 43 | Temporary laying of LT cables of following sizes in open air / in Built in trench. (Refer Sec VI (MNC), Clause No.30). |
| 44 | Sizes up to 3.5C X 70 Sq.mm Aluminium conductor (Refer Sec VI (MNC), Clause No.30). |
| 45 | Supply and installation of the following sizes of copper wires in built in trench as per the detailed specification.(Refer Sec VI, Clause No.12.8) |
| 46 | 8SWG copper wire |
| 47 | 14 SWG Copper Wire |
| 48 | Supply and Installation of MS Brackets, Supports, Frame work, Clamps, Base Channels, etc. fabricated out of angle / Channel / Rods etc. The rate quoted shall include the cost of fabrication / welding, cleaning and painting/ galvanising as follows including supply of required, fasteners, nuts, washers, etc.(Refer Sec VI, Clause No.11). |
| 49 | MS fabrication 1 coat primer & 2 coats synthetic enamel paint |
| 50 | Excavation of soil including refilling with excavated earth and disposing surplus earth at places as directed with in a lead of 10 Mtrs. and initial lift upto 1.5 Mtrs. including neat banking as per detailed specification. (Refer Sec VI, Clause No.2) |
| 51 | Supply and external installation of following sizes of Heavy Duty, Hot Dip Galvanised MS ERW Conduits for Electrical & Communication System with all the required accessories like round JBs, Solid Long Bends, Check Nuts, Nipples, Couplings, Reducers, Copper Clips, Copper Conductor, GI Wire etc. as per the detailed specification. .(Refer Sec VI, Clause No.27). |
| 52 | 20mm dia 1.6mm wall thickness Heavy Duty, Hot Dip Galvanised/ ERW Conduits with 50mm deep junction boxes. |
| 53 | 25mm dia 1.8mm wall thickness Heavy Duty, Hot Dip Galvanised/ ERW Conduits with 50mm deep junction boxes. |
| 54 | 32mm dia 1.8mm wall thickness Heavy Duty, Hot Dip Galvanised/ ERW Conduits with 50mm deep junction boxes. |
| 55 | 25mm GI Flexible Hose |
| 56 | Supply and external installation of following sizes of Heavy Duty, PVC circular rigid Conduits for Electrical & Communication System with required Solid Long Bends, Couplings, GI Wire etc, as per the detailed specification.(Refer Sec VI, Clause No.27). |
| 57 | 25mm Dia, 2mm wall thickness PVC heavy duty round rigid conduits with 50mm deep Junction boxes |
| 58 | Supply and Installation of following sizes of PVC trunking (casing & capping) on walls/Ceiling for routing of Power, Lighting and Telephone wires including all the required accessories like JBs, Coupling, External & Internal Bends, Elbows and end cap as per the detailed specification.(Refer Sec VI, Clause No.29) |
| 59 | 25 X 12 mm size of PVC Mini trunking |
| 60 | Wiring for lights / fans /sensors/ Power point with 1100V grade FRLS insulated copper conductor wires in existing concealed/ Exposed PVC / ERW / Flo-coated Metal conduits as per the detailed scope of work, including supply of Wires, termination of copper wires at either end by crimping including supply of PVC Sleeves/Ferrules, Copper Crimping Lugs and connecting the wires to various switches, sockets, etc. including testing and commissioning as per the detailed specification.(Refer Sec VI, Clause No.18) |
| 61 | Wiring with 1 Run of 1.5 Sq.mm Copper wire |
| 62 | Wiring with 1 Run of 2.5 Sq.mm Copper wire |
| 63 | Wiring with 1 Run of 4 Sq.mm Copper wire |
| 64 | Wiring with 1 Run of 6 Sq.mm Copper wire |
| 65 | Wiring with 1 Run of 10 Sq.mm Copper wire |
| 66 | Wiring with 1 Run of 16 Sq.mm Copper wire |
| 67 | Wiring with 1 Run of 25 Sq.mm Copper wire |
| 68 | Wiring with 1 Run of 35 Sq.mm Copper wire |
| 69 | Installation of MS boxes of the following types and as specified on MS frame/Wall as per the detailed specification. (Refer Sec VI, Clause No.15.10.8). |
| 70 | MS/GI box of size above 200(W) x 200(H) x 150(D) and up to 300(W) x 300(H) x 200(D)mm, 1.8mm thick |
| 71 | Loading, Transportation, Unloading at site, Laying, Testing and Commissioning of one number PVC/HRPVC/XLPE insulated and PVC sheathed Stranded Aluminium/copper conductor power cable of 1.1 KV grade of following sizes direct in ground including excavation, sand cushioning, protective covering with chamber burnt/cement bricks on sides & top, refilling the trench and providing RCC route indicator etc as required (Note: Cable will be issued free of cost by the department).(Refer Sec VI, Clause No.3) |
| 72 | 3/3.5/4 Core X upto 25 Sqmm |
| 73 | 3/3.5/4 Core X above 25 to 3/3.5/4 Core X up to 120 sqmm |
| 74 | 3/3.5/4CX Above 120 Sq.mm but not exceeding 3.5/4CX 240 sq.mm |
| 75 | 3/3.5/4 Core X Above 240 sqmm to 3/3.5/4Core X 400 sqmm |
| 76 | Loading, Transportation, Unloading at site, installation, Testing and Commissioning of 1100 Volts Grade PVC/HRPVC/XLPE insulated, Stranded Aluminium/copper conductor cables of following sizes in built-in trenches, on walls, poles and through embedded pipes including supply of GI spacer, clamps etc and as per the detailed specification (Note: Cable will be issued free of cost by the department).(Refer Sec VI, Clause No.3) |
| 77 | 3/3.5/4core X Upto 25 sqmm |
| 78 | 3/3.5/4Core X above 25 & up to 120 sqmm |
| 79 | 3/3.5/4Core X above 120 & up to 240 sqmm |
| 80 | 3/3.5/4Core X above 240 & up to 400 sqmm |
| 81 | Retrieval of the existing one number PVC/HRPVC/XLPE insulated and PVC sheathed power cable of 1.1 KV grade of following sizes laid direct in ground including Removal of end termination, excavation of trenches, retrieving of bricks and back filling as per the detailed specification.(Refer Sec VI, Clause No.5) |
| 82 | 3/3.5/4 Core Upto 25 Sqmm |
| 83 | 3/3.5/4 Core Above 25sqmm & upto120 sqmm |
| 84 | 3/3.5/4 Core Above120sqmm & upto240 sqmm |
| 85 | 3/3.5/4 Core Above 240sqmm & upto 400 sqmm |
| 86 | Retrieval of the already laid one number 1100 Volts Grade XLPE/HRPVC insulated, Stranded Aluminium conductor cables of following sizes in built-in trenches, on walls, poles and from embedded pipes including removal of end termination GI spacer, clamps etc as per the detailed specification. (Refer Sec VI, Clause No.5) |
| 87 | 3/3.5/4 Core upto 25 Sqmm |
| 88 | 3/3.5/4 Core Above 25 & Upto 120 Sqmm |
| 89 | 3/3.5/4 Core Above 120 & Upto 240 Sqmm |
| 90 | 3/3.5/4 Core Above 240 & Upto 400 Sqmm |
| 91 | Retrieval of the already laid one number PVC/HRPVC/XLPE insulated and PVC sheathed power cable of 1.1 KV grade of following sizes laid direct in ground including removal of end termination, excavation of trenches, retrieving of bricks, back filling and Re - laying the same cable direct in ground by using retrieved bricks including transportation of cables, excavation and backfilling of soil, supply of sand & shortage bricks etc as per the detailed specification. (Refer Sec VI, Clause No.7) |
| 92 | 3/3.5/4 Core Upto 25 sqmm |
| 93 | 3/3.5/4 Core Above 25sqmm & upto120 sqmm |
| 94 | 3/3.5/4 Core Above 120sqmm & upto 240 sqmm |
| 95 | 3/3.5/4 Core Above 240sqmm & upto 400 sqmm |
| 96 | Retrieval of the already laid one number 1100 Volts Grade XLPE/HRPVC insulated, Stranded Aluminium conductor cables of following sizes in built-in trenches, on walls, poles and from embedded pipes including removal of GI spacer, clamps etc and relaying the same cable in built-in trenches, on walls, poles and through embedded pipes using the retrieved spacer & clamp & supplying the shortage spacer & clamp if any as per the detailed specification. (Refer Sec VI, Clause No.7) |
| 97 | upto 3/3.5/4 C X 25 Sqmm |
| 98 | 3/3.5/4 Core Above 25 & Upto 120 Sqmm |
| 99 | 3/3.5/4 Core Above 120 & Upto 240 Sqmm |
| 100 | 3/3.5/4 Core Above 240 & Upto 400 Sqmm |
| 101 | End Termination of the following size Copper Conductor PVC/XLPE Insulated and FRLS sheathed armoured UG Cable using Single Compression, Heavy Duty, Siemens type Brass Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Copper crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. (Refer Sec VI, Clause No.10.1). |
| 102 | 4C x 2.5 Sq.mm including cable gland earthing |
| 103 | 4C x 10 Sq.mm including cable gland earthing |
| 104 | 4C x 16 Sq.mm including cable gland earthing |
| 105 | End Termination of the following sizes of Aluminium Conductor PVC Insulated and sheathed armoured UG Cable using Single Compression, Heavy Duty, Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Comet or equivalent make Aluminium crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. (Refer Sec VI, Clause No.10.1). |
| 106 | 4 Core X10sqmm |
| 107 | 4 Core X 16 Sqmm |
| 108 | 3.5/4 C x 35 sq.mm |
| 109 | 3.5/4C x 50/70 sq.mm |
| 110 | 3.5 x 95/120 sq.mm |
| 111 | 3.5 x 185 sq.mm |
| 112 | 3.5 x 240 sq.mm |
| 113 | 3.5 x 400 sq.mm |
| 114 | Supply Installation testing and commissioning of the following MCB on Distribution Boards as per the detailed specification. (Refer Sec VI, Clause No.14.2). |
| 115 | 6-32 Amps SP MCB (Type-C) |
| 116 | 6-32 Amps DP MCB (TYPE-C) |
| 117 | 6-32 Amps TP MCB (TYPE-C) |
| 118 | 6-32 Amps FP MCB (TYPE-C) |
| 119 | 40-63Amps, FP MCB (TYPE-C) |
| 120 | 125Amps FP MCB (TYPE-C) |
| 121 | Supply fixing testing and commissioning of the following RCBOs on Distribution Boards as per the detailed specification. (Refer Sec VI, Clause No.14.2). |
| 122 | RCBO FP 63A sensitivity 30mA 7Module |
| 123 | RCBO DP 40A sensitivity 30mA 4Module |
| 124 | Supply and Installation of following sizes of Surface Mounting Plastic Boxes as per the detailed specification. (Refer Sec VI, Clause No.15.6). |
| 125 | Surface Mounting Plastic Boxes 1/2 Module |
| 126 | Surface Mounting Plastic Boxes 3 Module |
| 127 | Surface Mounting Plastic Boxes 4 Module |
| 128 | Surface Mounting Plastic Boxes 6 Module |
| 129 | Surface Mounting Plastic Boxes 12 Module |
| 130 | Supply and fixing following Modular front cover plate on existing modular metal/plastic boxes etc. as required. (Refer Sec VI, Clause No.15.7). |
| 131 | One/Two module |
| 132 | 3 Module |
| 133 | 4 Module |
| 134 | 6 Module |
| 135 | 12 Module |
| 136 | 1 Modular dummy plate |
| 137 | Supply, embedment and flush mounting following sizes of Metal one way enclosures for MCBs, RCCBs, RCBOs including chipping and finishing as per the detailed specification. .(Refer Sec VI, Clause No.15.5). |
| 138 | DP Cat No:507791/ FP Cat No:507793 Metal one way enclosure (M/s Legrand/BCH or equivalent make) |
| 139 | FP RCBO Metal enclosure Cat No:507794 (M/s Legrand/BCH or equivalent make) |
| 140 | Supply, installation, testing and commissioning of the following sizes of Metal Clad Socket in sheet steel enclosure with Plugs and Socket as per the detailed specification. (MS item will be measured separately). (Refer Sec VI, Clause No.15.4). |
| 141 | 1 Phase, 20A MC socket box with 20A DP MCB |
| 142 | Supply and open installation of following Sizes of MS boxes as per the detailed specification. (Refer Sec VI, Clause No.15.10). |
| 143 | 135(W)x 135(H) x 50(D) mm , 1.6mm thick sheet MS Box |
| 144 | 160(W) x 135(H) x 50(D) mm, 1.6mm thick sheet MS Box |
| 145 | 210(W)x 135(H) x 50(D) mm, 1.6mm thick sheet MS box |
| 146 | 260(W) x 135(H) x 50(D) mm, 1.6mm thick sheet MS box |
| 147 | 260 x 210 x 50 mm, 1.6mm thick sheet MS box Please Enable Macros to View BoQ information |