| 1 | Supply of each set of Elevated Type Uni Directional Runway Guard Light Fixture Consisting of 1 pair of yellow lights together, flashing with LED lamp of series circuit 2.8 - 6.6 amps current, Yellow glass(if required), 1 x 2-pole secondary plug, including frangible collar, stand and with all standard accessories ready for site installation as required. |
| 2 | Supply of Inset type Uni directional Runway Threshold light fixture showing green & meeting ICAO requirements LED lamp of series circuit 2.8 - 6.6 amps current, control driver with suitable shallow base with side/bottom hole entry and matching body of the fitting, inner body and outer cover made of die cast aluminium complete with connected heat resistant accessories, prism assembly, optical assembly, \\"O\\" ring seal, pressure relief test plug, lense(s), two-pole secondary plug, hardware and all standard accessories and ready for site installation as required and as per the enclosed particular specifications. |
| 3 | Supply of Inset type Uni directional Runway End light fixture showing red & meeting ICAO requirements LED lamp of series circuit 2.8 - 6.6 amps current, control driver with suitable shallow base with side/bottom hole entry and matching body of the fitting, inner body and outer cover made of die cast aluminium complete with connected heat resistant accessories, prism assembly, optical assembly, \\"O\\" ring seal, pressure relief test plug, lense(s), two-pole secondary plug, hardware and all standard accessories and ready for site installation as required and as per the enclosed particular specifications. |
| 4 | Supply and Installation of Solar operated Road Holding Lights (as per ICAO/DGCA-CAR) comprising of a high intesity flashing red light having flashing frequency between 30 to 60 flashes per minute with suitable rated solar panel and SMF batteries along with water tight(outdoor type) enclosure, to provide 24 hrs flashing with and to be installed using suitable size frangible coupling pole by necessary excavation, cement concrete basement etc., as per direction of Engineer-In-Charge (Equivalent to AMA make AM-TL-S-BLK-A-300-12V) |
| 5 | Supply of C.I. Isolating Transformer housing box,water tight round type,metal container of outside size 330mm height 450mm made of 10mm thick cast iron moulding suitable to receive a light fitting base plate on the top and underground housing associated with transformer power cable and having a clear hole centre at one side surface centre 75mm above bottom surface suitable to receive one of 50mm dia \\"B\\" class GI pipe(Double Hole type) and including check nuts as required and another hole at 175mm from the bottom of the CI Box to receive one no. 15mm dia \\"B\\" class GI pipe and check nut as required.The box should have two SS earth bolts of M10 x 30mm tapped inside near the hole (4\\" away from the hole centre) and having a drain hole at the bottom suitably tapped to receive 15mm dia \\"B\\" class GI pipe and having clear opening of 220 mm at the top surface and 6 nos. M10 tapped hole at the hole centre 260 mm to receive fitting base plate and bolts as required as per the drawings. |
| 6 | Supply of C.I shallow box, water tight round type, metal container of outside size 330mm dia, 100 mm height made of 10mm thick cast iron moulding all round, except the top surface, which is 15mm thick , suitable to receive a light fitting base plate on the top and underground box having a clear hole centre at side surface, 20 mm above bottom surface suitable to receive one 32 mm dia \\"B\\" class GI Pipe and check nuts as required. The box should have two SS earth bolts of M10 x 40mm tapped inside near the hole (4\\" away from the hole centre) and having a drain hole at the bottom suitably tapped and having clear opening of 220mm at the top surface and 6 Nos. M10 tapped hole having centre to centre distance of 260mm to receive fitting base plate and bolts, complete as required. |
| 7 | Supply of LED Taxiway Edge Elevated type light fixtures up to 12 Watts & meeting ICAO requirments LED lamp of series circuit 2.8 - 6.6 amps current, complete with base plate, breakable coupling, mounting assembly, gasket, BLUE lens, one 2 pole-plug with leads etc., |
| 8 | Supply of LED Type Guidance Sign Board of various sizes made out of anodized 2 mm thick Aluminium frame with suitable angle support and 1.5 mm thick al. backcover, 4 mm thick polycarbonate sheet with glare free front face, the letter & symbol should be screen printed / on inside face with required colouring, suitable arrangement shall be made for water tighness & locking arrangement, including supporting frangible legs & frame etc., signboard shall be uniformly inernally illuminated with required numbers of LED lights to achieve illumination level and can operate on series circuit without flickering, complete as required and as specified in ICAO Annex. 14 Vol. I (legends as approved by Engineer-in-Charge). |
| 9 | Installation, testing and commissioning of operational guidance /mandatory signages of various sizes at various location at operational area of Airport. The signages should be installed in 1:2:4 grade cement concrete of 400X400X500mm (for legs) and a total base of 150mm thick which extends all around the board with the distance of 1500mm (front, back and both sides). The concrete base and leg foundation should be on the same level and 20-25mm above the ground level etc., complete as required as per the Annexure 14. |
| 10 | Supply of following size 5 KV grade Airfield Lighting Cable copper conductor XLPE insulated, PVC sheathed, unshielded, anti-termite and rodent treated, UG airfield lighting cable generally confirming to IS:7098 (Part-II) with up to date amendments and particular specifications of the following sizes as required:2C X 6 sqmm |
| 11 | Supply of following size 5 KV grade Airfield Lighting Cable copper conductor XLPE insulated, PVC sheathed, unshielded, anti-termite and rodent treated, UG airfield lighting cable generally confirming to IS:7098 (Part-II) with up to date amendments and particular specifications of the following sizes as required:1C X 6 sqmm |
| 12 | Supply of following size 5 KV grade Airfield Lighting Cable copper conductor XLPE insulated, PVC sheathed, unshielded, anti-termite and rodent treated, UG airfield lighting cable generally confirming to IS:7098 (Part-II) with up to date amendments and particular specifications of the following sizes as required:1C X 16 sqmm |
| 13 | Supply of following size 5 KV grade dry type Plug and Receptacle of type I, class 'B' primary connector kit with field attachment and suitable for 5 KV grade single core copper conductor, copper braided, XLPE insulated PE outer sheathed shielded cable, complete as required confirming to the technical specification. |
| 14 | 6 sqmm |
| 15 | 16 sqmm |
| 16 | Supply of following rating 5000V, 50 Hz Series Isolating Transformers encapsulated in polyester resin, finally moulded in neoprene type rubber and with primary and secondary connections suitable to be operated via ALCMS System confirming to specification as required suitable for above mentioned fittings for following applications and compatible to use on ALCMS |
| 17 | 15W, 6.6/6.6A |
| 18 | 15W, 20/6.6A |
| 19 | 100 W, 6.6/6.6A |
| 20 | Supply of 50 mm dia HDPE pipe, lSI marked along with all accessories like socket, couplers etc. conforming to IS 4984-1995, PN4 grade, PE63 etc |
| 21 | Laying of DWC/HDPE pipe up to 63 mm size complete with fitting and cutting, jointing etc.direct in ground (80 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. |
| 22 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 5 KV/1.1KV grade of upto 35 sq.mm in the existing RCC/HUME/STONE WARE/METAL/DWC/HDPE pipe as required. |
| 23 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV/5kV grade of upto 35 sq.mm size on cable tray/surface as required |
| 24 | Making field connections by crimping of 6/16 sq.mm plug & receptacle with suitable existing size single core PVC cu. Conductor cable of 5 KV grade Airfield cable including filling the gap with water sealant material applying PVC insulation tape etc. complete as required |
| 25 | Installation, Testing and Commissioning of inset type Runway threshold/Runway End/ turnpad centre line lights/ taxiway light fitting in the runway/Taxiway with core cutting, setting i/c providing sealing material and other accessories inter connections etc.,as required for commissioning. |
| 26 | Installation, testing and commisiong of Elevated type Runway edge lights/Taxiway edage lights/Runway Guard lights on transformer housing box/shallow box,installation of transformer, lens, lamps gasket,nut bolts, lens holding clamp and other accessories i/c alignment,connection, earth connection etc. as complete as required. |
| 27 | Installation of round type transformer housing box with base concrete of 1:3:6 of size 630 x 630 x 100 mm thick all around concrete of 1:2:4, 150 mm thick top slopped with 1:2:4 cement concrete including providing and fixing 10\\" long 1/2\\" dia B class GI pipe with check nuts for drainage of water including excavation and refilling, aligning the boxes in straight line etc complete as required. |
| 28 | Installation of shallow box of edge lights on hard surface(concrete)/flexible surface (Bitumenous).Installation of Shallow box of 330mm dia, upto 200 mm (as per requirement) height, marking the location of edge light fittings on taxiway,core cutting by using suitable core cutting machine, up to a depth suitable for shallow box, cleaning, keeping the provision for secondary cable entry, precision alignment of box, cleaning, fixing with epoxy sealant , finishing and copping with cement mixture, numbering with paint, cleaning the area etc complete as required. |
| 29 | Supply of 2C X 4.0 sqmm secondary lead made out of multi stranded copper conductor, EPR insulated and PCP sheathed 1.1kV grade underground cable complete as required. |
| 30 | Groove cutting, laying of secondary lead with providing & fixing of earth wire from shallow box to transformer housing box (concrete surface):Cutting of groove having depth up to 30mm and width up to 20 mm on concrete surface by using suitable cutter machine, cleaning laying of 2C X 4.0 sqmm secondary lead with providing& fixing of single core 4sqmm copper earth wire from shallow box to existing transformer housing box, filling the gap with epoxy sealer(poly suplide), providing masking tape on both side of the groove to avoid spillage, finishing, cleaning the area etc., complete as required. |
| 31 | Groove cutting, laying of secondary lead & 32 mm dia DWC pipe with providing & fixing of earth wire from shallow box to transformer housing box (flexible surface):Providing and laying of 32mm dia DWC pipe on flexible pavement including groove cutting by using suitable cutter machine, cleaning and laying of 2C X 4.0 sqmm secondary lead in pipe with provide& fixing of single core 4sqmm copper earth wire from shallow box to existing transformer housing box, filling the gap with cold bitumen/epoxy sealer/micro concrete/any other superior material , finishing, cleaning the area etc., complete as required as per direction of Engineer-In- Charge. |
| 32 | Excavation of the cable trenches in hard rock not exceeding 1.5 meter in width, and lift upto 1.5 meter, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 meter. |
| 33 | Providing and fixing 6 SWG dia G.l. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ sub main wiring/ cable as required. |
| 34 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 35 | Moulding of secondary cable of size 2C X 4 sqmm of 1.1 kV grade at site with required 2 pin plug& Receiptacle connectors complete as required |
| 36 | Supply and fixing of 10mm thick MS dummy plate of 330 mm dia having 6No X M-10 holes along the circumferential of 260mm dia suitable to install on existing transformer housing box including providing and fixing of rubber gasket and SS bolts, nuts, washers etc., as required |
| 37 | Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) for existing signboards as per direction of E-I-C. |
| 38 | SITC of Airport/Aerodrome IP65, 10-18 rpm adjustable-or 12 RPM fixed Halogen type Rotating Beacon (4 LAMP) type L-802A, FAA certified / Compliant FAA AC 150/5345-12F with upto-date amendments, beacon lights shall indicate green & white flash alternatively, must appear at any point throughtout 360 degree azimuth, Minimum effictive intensity of white flash 75000cd (Minimum Effective Intensity of Flash in Candelas) at Elevation angle in degrees 3 to 7 and suitable to operate on 230V 50 Hz AC supply etc, Lamp life 4000 hours (minimum), having remote control capability, Operational status monitoring, lamp fault monitoring facilities, IPX5, Temperature range - 55C to +55C (-67F to +131F), Wind withstand capacity -160km/h, including civil / MS foundation work, ON/OFF control panel, extension ON/OFF of beacon from control desk of ATC/Fire tower, all required switches, contactors, connection/inter-connections etc. including testing and commissioning of the beacon and confirming to tenders technical specifications, terms and conditions etc. complete as required complete. |
| 39 | Supply of spare 1000 W lamp for Rotating Aerodrome Beacon light etc as required. Please Enable Macros to View BoQ information |