| 1 | Electrical Works |
| 2 | Supply and fixing of Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 3 | Supplying and laying 25 mm x 5 mm Copper earth strip ISI marked 1.15Kg/Mtr at 0.5 meter below ground level as Strip earth electrode including soldering etc. as required |
| 4 | Supply & Installation of 4 pole MCCB, 125A, 36kA Ics=100% Icu and Operational Voltage 690V including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 5 | Supply & Installation of Panel mounted Earth Leakage Relay (ELR) range 30mA-30A 220 - 415 VAC with CBCT(circular) 92mm ID including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 6 | Supplying & fixing of 40 A, rating, 4 pole RCCB, 30mA including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 7 | Supply, Installation and commissioning of Brass compression gland for 3.5C, 240 sq.mm 1.1 KV grade XLPE insulated Aluminium Armoured cable,Aluminium lugs for 240 sq. mm cable and Aluminium lugs for 120 sq. mm cable with all accessories, cost of labour, materials, T&P etc complete work as per direction of Engineer-In-Charge . |
| 8 | Supply, Installation and commissioning of Brass compression gland for 3.5C, 185 sq.mm 1.1 KV grade XLPE insulated Aluminium Armoured cable,Aluminium lugs for 185 sq. mm cable and Aluminium lugs for 95 sq. mm cable with all accessories, cost of labour, materials, T&P etc complete work as per direction of Engineer-In-Charge . |
| 9 | Supply, Installation and commissioning of Brass compression gland for 3.5C, 50 sq.mm 1.1 KV grade XLPE insulated Aluminium Armoured cable,Aluminium lugs for 50 sq. mm cable and Aluminium lugs for 25 sq. mm cable with all accessories, cost of labour, materials, T&P etc complete work as per direction of Engineer-In-Charge . |
| 10 | Supply, Installation and commissioning of Brass compression gland for 3.5C, 35 sq.mm 1.1 KV grade XLPE insulated Aluminium Armoured cable,Aluminium lugs for 35 sq. mm cable and Aluminium lugs for 25 sq. mm cable with all accessories, cost of labour, materials, T&P etc complete work as per direction of Engineer-In-Charge . |
| 11 | Supply, Installation and commissioning of Brass compression gland for 3.5C, 25 sq.mm 1.1 KV grade XLPE insulated Aluminium Armoured cable,Aluminium lugs for 25 sq. mm cable and Aluminium lugs for 25 sq. mm cable with all accessories, cost of labour, materials, T&P etc complete work as per direction of Engineer-In-Charge . |
| 12 | Supply, Installation and commissioning of Brass compression gland for 4.0 C, 16 sq.mm 1.1 KV grade XLPE insulated Aluminium Armoured cable,Aluminium lugs for 16 sq. mm cable with all accessories, cost of labour, materials, T&P etc complete work as per direction of Engineer-In-Charge . |
| 13 | Supply, Installation and commissioning of Brass compression gland for 4.0 C, 10 sq.mm 1.1 KV grade XLPE insulated Aluminium Armoured cable,Aluminium lugs for 10 sq. mm cable with all accessories, cost of labour, materials, T&P etc complete work as per direction of Engineer-In-Charge . |
| 14 | Supply, Installation and commissioning of Brass compression gland for 4.0 C, 6 sq.mm 1.1 KV grade XLPE insulated Aluminium Armoured cable,Aluminium lugs for 6 sq. mm cable with all accessories, cost of labour, materials, T&P etc complete work as per direction of Engineer-In-Charge . |
| 15 | Supply and Fixing of 400Amp, TPN Changeover switch disconnector fuse unit with Contact Kit & operating handle In Sheet Steel Enclosure including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 16 | Supply and Fixing of spike copper Lightning arrester of 9mm dia 912mm long solid including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 17 | Supply, installation, testing and commissioning of 25 metre high octagonal / polygonal high mast lighting tower made of hot dip galvanised steel, complete with base plate, anchor bolts, nuts & washers, suitable for wind load as per IS standards. The item includes supply and erection of lowering & raising mechanism with stainless steel wire ropes, winch system, electrical wiring inside mast, aviation obstruction lamp, earthing terminal, and feeder pillar. Supply and fixing of 12 nos. 350 Watt LED flood light luminaires with high efficiency LEDs, IP-66 protection, aluminium die-cast housing, toughened glass cover, suitable drivers, brackets and aiming arrangement.The work also includes civil foundation with excavation, PCC/RCC, grouting, curing, cable termination, earthing (minimum two earth pits), Feeder Pillar with appropriate switchgears, light wiring to be made in such a way that it should get a voltage level of 230V (Ph-Ph) testing and commissioning, complete in all respects as per specification and direction of Engineer-in-Charge. |
| 18 | Supply,Installation,Testingand Commissioning of Floor mounting front operated front access extensible type cubical double door outdoor type, IP- 54 rated panel totally enclosed with 2 mm CRCA Sheet including Powder Coating, bonding to earth, double compression gland and painting suitable as per below specification, as per direction of EIC: MAIN PANEL :- (i) 5 kVA, 3-Phase, 440/230V transformer-1 No.(ii) 63Amp MCCB,4pole, C-Curve (l&k BB40630C)- 1 No. (iii)Digital Timer (L&K WT2DCDS)-1 No.(iv)Contactor MNX 40 (L&K CS94190)-3 Nos.(v)Earth Leakage Relay(240-415V AC/AD) 1 C/O pre-alaram + 1 C/O Fault-1 No.(vi)CBCT(circular) 38mm ID-1 No.(vii)Shunt Release DZ1 415v AC-1 No.(viii)Auxiliary Contactor DN0, DN1 - 2 C/O- Right (L&K CM97887OOOO)-1 No.(ix)R-Y-B LED Indicating lamp 220/240V AC(L&K)-3 NO. (x) 6Amp SP MCB, 10KA, B-curve (L&K)- 1 No. (xi)Push button-2 Nos. (xii) Cost of 50kA, Type-1+2, 3P+N SPD (L&K-AUSP123PN50)-1 No. including all accessories, cost of labour, T&P,etc complete work as per direction of EIC. Please Enable Macros to View BoQ information |